Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | ₹36.0 L | L1 | Accepted-AOC l1 |
| 2 | L2₹36.3 LRejected-AOC | ₹36.3 L | L2 | Rejected-AOC l2 |
Tender Value
₹36.0 L
EMD Value
₹36,000
Closing Date
23 Jan 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer, P.W.D., Building C and M Division-3, Chepauk, Chennai-05
Special repairs to proposed Historical Research Council Director Room,Conference Hall and other connected Civil Works in Second Floor of Gazetter unit Sections in Tamilnadu Archives Campus at Egmore,Chennai-08
2026_PWD_644475_1
PWD/BCMD3/18/01/2025
Open Tender
Civil Works
90 days
Egmore, Chennai-8
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹36,000
Yes
14 Mar 2026
19 Jan 2026
23 Jan 2026
19 Jan 2026
23 Jan 2026
19 Jan 2026
Dismantling the damaged floor finish and dadooing walls in cement mortar with mosaic tiles / Glazed tiles/cuddapah slab and clearing away with carefully stacking the material useful for reuse for any thickness etc., complete complying with standard specification and as directed by the Departmental officers.
Dismantling the damaged Brick / Stone Masonry in cement mortar walls under 3m high and clearing away with carefully stacking the material useful for reuse for any thickness etc., complete complying with standard specification and as directed by the Departmental officers.
Dismantling the damagedDoors and Windows including removal of frames, hinges and fastenings clearing away with carefully stacking the material etc., complete complying with standard specification and as directed by the Departmental officers.
Dismantling the damaged Plain cement concrete and clearing away with carefully stacking the material useful for reuse for any thickness etc., complete complying with standard specification and as directed by the Departmental officers.
Dismantling the One Course of Pressed Tile Roof fnish in cement mortar with carefully stacking the material useful for reuse for any thickness etc., complete complying with standard specification and as directed by the Departmental officers.
Providing Post constructional Anti termite treatment by drilling 1/2" dia holes at uniform intervels of 12" at the junction of the building and the Chemical ALDRIN (0.50%) will be walls and floors to a depth of 4" to 5" inside or as directed by the departmental officers. The building and the chemical ALDRIN (0.50%) will be quirilled inside these hole leg using hand pressure pumps from itrs fills to it refusal. The wooden frame will be spread by the same termicide solution center pheriphery of the building will be treated by the making a small chamel around the building and the holes are to be made by ysing crow bar around termicide (ALDRIN) to be squrilled inside these holes after completion of treatment all holes drilling in the walls and floor closed by cement etc complete complying with std spn, and as directed by the departmental officer. The chemical is to be used on the work should be got approved by the executive engineer's before use on the work.
Finishing the top of roof with one course of machine pressed tiles of following size of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Using Pressed Tiles of 230mm x 230mm x 16 mm to 18mm
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
Second Floor
Old Terrace Screed Repair with UV Resistant Waterproof coating below 500 Sq.m - Providing and Applying high perfomance solar reflective & Acrylate silicon based Waterproofng coating which is single component, cold applied, water based acrylic and UV resistant water proofng treatment to the Existing Roof screed surface applied @ 1.5 l/m2 in 3 coats to achieve 1mm DFT, having tensile strength 2N/ mm2 confrming to ASTM D 412; Elongation at break ≥ 200%, Abrasion resistance 21mg confrming to ASTM D 4060 and Crack bridging ability up to 2 mm, including surface preparation, priming the surface with 1 coat diluted with water in the ratio 2:1 spreading @ 0.125 L/m2 as self-priming coat in the SSD condition and spreading 45 gsm glass fbre mesh of 2.5 mm x 2.5 mm sandwiched between the frst and second coat completely as per specifcation. The fnished cost to include surface preparation, making coving at Junction, treatment of cracks completely as per specifcation.
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Providing and laying in position, standardised concrete Mix M-20 Grade by insitu machine mix concrete adopting weighing batch method in accordance with IS 456 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m) 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials).
For Second floor
Flooring with Self Designed Colour Ceramic Tiles of size 305 x 305 x 6mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Dadooing walls with printed design colour glazed tiles of size 300 x 450 x 8mm conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9" x 4 3/8" x 2 3/4" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge.
In Second floor
Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
Paving the floor with best quality Double charged Vitrified Tiles 1200x600x8mm and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of Size : 1200 x 600 of 18 / 20mm thick and Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., complete complying with standard speicification and as directed by the departmental officers.(The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work)
Supplying and Fixing the Fasle Ceiling using Hilux Board Plain Sheets (10mm thick) of approved quality and design suspended from the ceiling using "U" shaped Galvanised iron channels at 1.20 M centre to centre on both longitudinal and cross direction for vertical support and fixing "U" shaped G.I channels at 0.90 m centre to centre on longitudinal direction respectively for horizontal support by using T.W reapers at corners and at intermediately and fixing of plaster of paries on the panel provided as per design / patttern given by the site officer and finishing the ceiling surface with some plaster of paries materials etc. Necessary openings should be made for providing spotlights, florescent tubes in the ceiling by using plywood 12 mm thick and opening should be covered with Acrylic panel complying with standard specification and as directed by the departmental officers etc. complete. All the materials should be got approved before use on work by the Executive Engineer.The rate is including two coats of plastic emulsion painting over the wall coat primer etc., complete.
Supplying and fixing in position of Fully Calcium silicate HILUX Board Partition using alu box section and aluminium anodised powder coated frame at an interval of 0.75m at the aluminium frame of size 63.50mm x38.10mmx 1.28mm, 1.41mm @ 0.818kg/m with necessary 'L' Angles, screws, nails and fixed in the wall using drilling machine with neat straight alignments etc., after finishing the frame work and fixed with both side 10mm thick HILUX BOARD approved quality and ISI make with necessary screws nails, fevicol and necessary grooves as per instruction of the departmental officers and also cutting the partition for Electrical Switch box and AC Plug Box and telephone Box requirements and finally cleaning the wooden partition for both side with neat position etc. The partition both side should be finished with best wall putty and painting two coats of plastice emulsion paint over one coat of primer including preparation of surface etc. The rate is inclusive of cost of materials, labour charges aluminium frame work and partition work, transporting charges etc., complete as directed by the departmental officers. (The materials quality and colours are approved by the departmental Engineer before use of works)
Supplying and fixing solid core flush shutter of following type with thickness with necessary T.W. internal lipping alround conforming to IS 2202-1(1999) including cost of wind appliances and furniture fittings such as 3 Nos of SS 304 Grade Parliament Hinges of Size (125mm x 150mm), 2 Nos 300x12mm aluminium tower bolt 1 No. 200x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 2 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete complying with standard specification and as directed by the departmental officers - Single leaf. Door Shutter Type : Thickness: 35mm thick
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Supplying and fixing with new of Premium Quality vertical blinds including loading , unloading charges and fixing in position etc,, complete and as directed by the Departmental officers ( Colour and design approved by the executive officers )
Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specifcation. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fxing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fxing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fxed over the plywood using adhesive and fnishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Ofcers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.
Supplying and Fixing of WPC Door With frame : Wood Plastic Composite Solid Door with Density of 900 kg / cum and it is waterproof and termite proof. It is Premium WPC Door with complete aesthetic Door of natural look with Polished surface finish. The rate inclusive Labour, Fixing Charges and Material charges and transporting charges complete complying with standard specification and as directed by the departmental officers.
Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed by the departmental officers.
UPVC Ventilator Specifcation: Supplying and fxing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profle the size of outer frame 60mm x 58mm and shutter profle size of 60 x 78mm both profles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profle are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fxed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Supplying, fabricating and fixing in position Aluminium Anodised natural colour mat finish Two track sliding window in all floors with Aluminium sections of outer Frame bottom 62x37mmx1.50mm at 1.218 kg/m,the Side & Top 62x31.50x1.50mm at 0.778 kg/m,Shutter Top 40x18x1.5 at 0.38 kg/m,Bottom 40x18x1.5 at 0.38kg/m, Side Vertical 40x18x1.50mm at 0.493 kg/m, Vertical locking section 40x29x1.5mm at 0.632 kg/m, with necessary accessories such as rubber beadings, special hinges, lock, handle including supplying and fixing 4mm thick plain glass including cost of all materials , labours, power consumption required for fabrication , drilling holes in RCC colunm, slab, masonry walls wherever necessary with power drills to the required extent and make good to the original condition after fixing etc... complete complying with standard specification and as directed by the deparmental officers.The aluminium sections are to be anodised with matt finish under electrically controlled in accordance with IS 1868 / 1962 for an average anodic film thickness 15 microns etc., complete.
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
110mm dia PVC soil waste pipe
75mm dia Pvc pipe
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re- doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
110mm dia Door tee
110mm dia Door elbow
110mm dia Plain elbow
110 mm dia x 75 dia Reducer
75mm dia Door tee
75mm dia Door elbow
75mm dia Plain elbow
Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/ sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting, and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3(2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply - above ground level.
25mm dia Upvc pipe line
20mm dia Upvc pipe line
Supplying UPVC Specials in water supply arrangements (both in internal and external water supply arrangements.
25mm dia Upvc Tee
25mm dia Upvc elbow
25mm dia Upvc coupling
25mm dia Upvc x 20mm reducer
20 mm dia Upvc Tee
20mm dia Upvc elbow
20mm dia Upvc coupling
20x15mm dia Reducer
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing position Nahini Trap with stainless steel grating with best stainless steel gratings of size 100 x 75mm with stainless steel gratingsof approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works).
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works).
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., includ- ing dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Painting Old Plastered Wall Surface with Two finishing coats of ready mixed Interior (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work).
Distempering the Two Coats of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the departmental officers.
Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with One coat of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Best Varnishing Woodwork One Coat of approved quality in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality of paint should be got approved by the Executive Engineer before use on works.)
Painting Old Plastered Wall Surface with one finishing coats of ready mixed Exterior (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Collecting the scattered debris from the campus and coveying away the same to outside by lorry to a lead of not less than 10km within city limit including loading and unloading charges and dumping in low place and levelling etc., complete complying with standard specification and as directed by the departmental officers.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_772338.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Condition1.pdf
Tender Documents • 0.75 MB
BOQ_772338.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid