Signalling works in connection with "Hebsur: Provision of 02 additional loop lines."
03UBL2026-27
03UBL2026-27
Open
15 Months
Dharwad, Karnataka
₹0
₹18.6 L
2 Jul 2026
2 Jul 2026
20 Jul 2026
Item Breakup - A-Chapter -3
8.00 159901.00 type 220 mm throw with Lock and detector Slides, Cable termination box and clamp lock arrangement with Ground connection, Insulation's etc. for thick web switch ,confirming to RDSO Specification no IRS:S24-2025 Revision 3.0 or latest.
200.00 Connection, Made of Nylon for 220mm throw Point Machine as per latest specification No. IRS.S.40/84 Amdt No.01 or latest. One Set consisting of :- a) Insulating Washer Drg. No.-S-8640 = 12 Nos. b) Insulating Washer Drg. No.- S- 8640/1=04 Nos. c) Insulating Washer Drg. No.-S-8640/2=02 Nos. d) Insulating Bush Drg. No.-S- 23199=06 Nos. e) Insulating Bush D7Drg. No.-S-3463=01 No. f) Insulating Bush Drg. No.- S22179=02 Nos. g) Insulating Bush Drg. No.-S-8912=02 Nos. h) Insulating Plate Drg. No.-S- 3404=02 Nos. i) Insulating Bush Drg. No.-S-8813 = 04 Nos.
10.00 type 143 mm throw with Lock and detector Slides, Cable termination box with suitable ground connections, Insulation's etc. confirming to RDSO Specification no IRS:S24-2025 Revision 3.0 or latest HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
200.00 switch extension bracket to suit to universal point machine as per RDSO Drawing supplied by the Railways. (One set consists of 'D' clamp insulation - 2 No. Nylon insulation bushes 4 No., Nylon insulation washers - 8 No.)
10.00 143 mm and connecting all ground connections including wiring and termination in point machine and inter connections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration. (Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways. [All types of insulations connected to point work, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor].
8.00 termination box, wiring, testing and commissioning of IRS High Thrust point Machine 220mm.This includes fixing of point machine on MS plate fixed on sleepers complete with fixing of anti- theft covers, MS termination boxes, ground connections, required insulation, crank handle ward (wherever required) etc. This also include necessary adjustment and smithy work, drilling of holes on tongue rails, supply of all miscellaneous material such as flat, angle, bolt, nuts, pins etc.
8.00 Point machines (all types) including ground connections and other accessories available complete without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
18.00 termination boxes on rails/L-angle and concreting as per RDSO Drawing , drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mmlong at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable entry and one GI pipe 150mm long 32mm dia for drawal of jumper wires for Point machines etc., fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of CT boxes is not covered in this item. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.) [Cement, iver sand, stone jelly of size20/25mm, paint, varnish, GI Pipes 32mm dia - 300mm long - 2Nos and 150mm long - 1 No., clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor]. Total 3140796.00
Item Breakup - A-Chapter -15
10.00 RDSO Drawing No.SG/SWR/057 and Earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, ASM room for block and control, and earthing of all equipment's in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS of flat 35mm X 6mm or 19c cable (MS flat for closer by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. (Supply of 19C cable is not covered in the scope of this schedule). [MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Installation, Commissioning of Copper Plate Earthing System complete as per Drg.No.SG/SWR/058 with provision of (i) Copper plate 300 mm X 300mm X 3 mm, (ii) Earth Pit 6 ft depth filled up with charcoal 10 kg & salt 25 kg in alternate layers up to 2 ft from bottom, (iii) Water funnel on Perforated GI pipe of length 4.5 ft., (iv) Cast Iron top plate 12 x 12 (v) Drawing of copper - earth from earth to location with 25 mm x 3 mm copper strip for termination (All miscellaneous materials to be supplied by the contractor).
2.00 Unit maintenance free earth as per RDSO spec. No. RDSO/SPN/197 Ver.1.0 or latest. consisting of a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked--1 no. b) Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-03 No. c) Copper strip of 150X25x6mm to terminate earth rod-1 No. d) Copper strip of 300X25x6mm (MEEB)-1 No. e) Copper strip of 150X25x6mm (SEEB)-1 nos
2.00 Earth Pit as per RDSO specification No.RDSO/SPN/197 Ver.1.0 or latest and as per Technical Specification
1000.00 Core PVC insulated Copper Cable as per IS: 694 for connecting Main Earth Electrode to MEEB in equipment room. Color: Green.
80.00 3mm for down conductor with all supporting accessories.
80.00 conductor strip 25X3 mm from top of the building to ground level duly securing the same to the building.
for Metre interconnecting earth electrodes.
for Metre interconnecting earth electrodes.
2.00 of class B and C suitable for single phase supply in TT network as per RDSO spec.no. RDSO/Spn/165/2023 ver 4.0 amd.1 or latest. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
2.00 B and C arresters as supplied. These din rail mountable devices along with 63 amps HRC input fuse and fuse base shall be fixed in a wall mountable cabinet of size 450 x 250x150 mm made as MS steel of 20 gauge or better with IP31 protection and power coating. All the internal power wiring shall be made by using 10sq.mm cu cable. the PF contract of the class C arrestor shall also be wired using cable thickness of 2,5 sq.mm and terminated on a suitable terminal block.
1.00 156808.00 channel (4 Channels110V AC, 2 Channels- 110V DC, 6 Channels- 24V DC) as per RDSO Spec./256/2002 or latest with 6-digit counter.
1.00 Earth Leakage Detector 8/12/16 channel. Total 2591368.00
Item Breakup - A-Chapter -19
8.00 Brand: RISHABH 18S or similar.
2.00 Current measurement upto 200A AC/DC True RMS measurement for AC voltage & current. (Large jaw of size of 18mm) Model: FLUKE 362/Rishabh or higher as per specification.
2.00 selection of 500V, 100V. Make RISHABH or similar.
4.00 metal carrying box and auxiliary earthing net Make Wago or better.
1.00 479874.00 specification. Make: Stanley or similar
1.00 321076.00 per specification- Make Stanley or better.
2.00 with suitable horizontal stand with attachments to drill holes of various sizes up to 7mm to 13mm Make Ralliwolf Model WD 34 C or similar. Total 1087994.00
Item Breakup - A-Chapter -12
Installation, commissioning of SMPS based Integrated Power Supply (IPS) up to 4 Lines in RE area confirming to RDSO Specification No. RDSO/SPN/ 165/2023 (Ver. 4.0) or latest along with B & C Class SPDs,63 Amps fuse, status monitoring panel. IPS should be supplied with (55+5@61<41@ Nos. of uncharged LMLA Secondary Cells 2V- 200AH/2V-300AH(For RE section 2V/200AH for non RE section 2V/300AH) as one set for one IPS confirming to QA IRS:S-88/2004 Low Maintenance Lead Acid Stationary Secondary Cells For S&T Installations along with 16/25 Sqmm cable for each IPS set is (50 Mtrs Red + 50 Mtrs Black + 50 Mtrs Green) = 150 Mtrs. SPECIAL CONDITIONS:1.Including supply of all the accessories required for installation. The supplier shall take up installation, wiring, testing and commissioning with minimum one-month prior notice period from Railways. 2.All the required cables/ Miscellaneous items like wooden plank, ladder etc. for installation and commissioning shall be supplied as part of the work. 3.Supply, installation, testing and commissioning of SPDs (class B&C) are covered in scope of this work. 4. Contractor should make the power supply arrangements if any required for charging the supplied cells at site. contractor should arrange the industrial grade diluted H2SO4 for the charging of cells. The cells should be charged as per latest specification.
1.00 Distribution Panel for IPS using Hylam sheet 10 mm as per site requirement and erecting it using MS angle clamp 65mm X 65mm X 8mm, HRC fuse block, Mains control switch, ammeter by-pass switch, voltmeter, ammeter, PBT terminals 60mm and wiring the same using wire PVC 7/1.40mm as per approved power diagram. This also includes termination of power cables using teakwood clamp of size 25mm X 60mm X 150mm on a base plank of 25mm thick 150mm width. (MS angles 65mm X 65mm X 8mm, Hylam sheet of 10 mm Thickness, as per site requirement, bolt and nuts required for manufacture of power panel, HRC fuses, box and carriers, teak wood clamp, wire 7/1.40mm, PVC casing and capping and all other miscellaneous materials will be supplied by the contractor, Supply of PBT terminals 60mm is not included in the item). HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 IPS to power distribution panel. This includes transportation of IPS batteries from stores to the site, Erection of IPS panels on teakwood planks, interconnection between panels and wiring the IPS to power distribution panel using 10 sqmm multi-strand copper cable. The wiring should be done neatly using Aluminium ladder with phenolic sheet (Aluminium ladder, phenolic sheet of thickness 6 mm, teak wood plank of width 150 mm and thickness 25mm, 10 sqmm multi-strand copper cable and all other miscellaneous materials to be supplied by the contractor).
1.00 Change over arrangement at SM room. CLS panel of size 800x500x275mm powder coated of MS sheet thickness 1.6mm as per RDSO specification: TI/SPC/PSI/CLS/0025 or latest
150.00 secondary cells 2V-80AH capacity as per IRS: S 88/2004 Version 1.0 or latest.
150.00 of 2V-40/80AH capacity in apparatus cases, connecting them with strips, wiring with wire PVC 3/0.75mm copper and termination. This work also includes charging of cells through reputed agencies. The details of the batteries shall be written on the inside of the doors of the apparatus cases. (Supply of secondary cells is not included in this item). [Wire PVC 3/0.75mm copper, connecting strips, paint and all other miscellaneous materials required for the work shall be supplied by the Contractor].
1.00 input voltage 160V AC - 280 V AC, output voltage 230V AC, Operating Freq 47-63 Hz with back up time 30 minutes (APC, Emerson or similar make).
100.00 holders 20 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
100.00 links 16 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
100.00 links 10 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
100.00 links 6 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
200.00 links 2 Amps for Railway signalling, voltage 240 AC/DC to Specn. No. IRS S.78/2006.
1.00 plant (Aqua-Ion Model No. ACAMB 4 Bed Type). HUBLI DIVISION-S AND T/SOUTH WESTERN RLY Total 2500873.00
Item Breakup - A-Chapter -16
installation commissioning of Heat and smoke multi sensor as per RDSO/SPN/217/2025 ver- 3.1 or latest. along with its base, back- box and all accessories incompliance with IS:2175 and IS:11360 standard sand Under writers Laboratory (UL) listed.
installation, commissioning Fault isolator as per RDSO/SPN/217/2025 ver-3.1 or latest with backbox and all other accessories
installation, commissioning of Networkable single loop addressable Fire alarm Control panel expandable upto 4 loops with GSM interface as per RDSO/SPN/217/2025 ver-3.1 or latest. This work involves supply, fixing, installation and testing of control panel. The control panel shall be networkable to Zonal /Divisional headquarters preferably over TCP/lP and shall have clock synchronization facility. This includes Networking module (TCP/IP) for control panel along with power supply unit and battery set of required capacity for 24 hours backup as per RDSO specification. The panel should support degrade mode operation in compliance with IS: 2189, EN54 standards and Underwriters Laboratory (UL) listed.
installation, testing and Numbers commissioning of GSM module for Control panel with backbox and all other accessories as per RDSO/SPN/217/2025ver-3.1 or latest. with auto dialer function to SMS during failure or fire situation.
installation, commissioning of Manual call point (resettable) with backbox and all other accessories as per RDSO/SPN/217/2025ver-3.1 or latest
installation, testing commissioning of Relay module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest
installation, commissioning of Hooter and Visual strobe alarm units with backbox and all other accessories as per RDSO/SPN/217/2025 ver-.3.1 or latest along with its power supply unit.
installation, commissioning of Control module with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
installation, commissioning of EOL as per RDSO/SPN/217/2025 ver-3.1 or latest as directed by the site engineers
installation, testing and Numbers commissioning of Monitor module for 3rd party with backbox and all other accessories as per RDSO/SPN/217/2025 ver-3.1 or latest
200.00 cables on PVC pipe / capping casing, or cable trays, ladder, shelter etc. as instructed by Railway engineer at site. (Indoor cables to be drawn through pipe, outdoor cables if required to be clamped on wall /floor etc.
600.00 sq.mm armoured as per RDSO/SPN/217/2025 ver-3.1 or latest.
of detector. Highly sensitive smoke aspiration system for monitoring of rooms and equipment for earliest possible fire detection For Relay rooms as per RDSO spec No.RDSO/SPN/217/2025 ver3.1or latest.
2.00 257648.00 CPVC Pipes with all required accessories for the Aspiration System. (Per Unit = Per Relay Room)
2.00 Testing and Commissioning of Aspiration Smoke detection Supplied. Total 2557663.00
Item Breakup - A-Chapter -5
1.00 (master telephone) for LC gate telephone system with Voice Logger facility as per RDSO Spec No.RDSO/SPN/TC/51/2021 (Rev 1.0) or latest
2.00 (slave telephone) for LC Gate telephone System as per RDSO Spec No.RDSO/SPN/TC/51/2021 (Rev 1.0) or latest.
1.00 system 24V DC power pack with 7AH MF battery for electronic LC gate Telephone as per RDSO specification No.RDSO/SPN/TC/51/2021 (Rev 1.0) or latest. Total 67686.00
Item Breakup - A-Chapter -9
1.00 420185.00 Maintenance Free Earth as per RDSO Spec No. RDSO/ SPN/197/2016 ver 1.0 or latest and as per technical specification. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 212768.00 Pit for Ring Earth as per RDSO specification No.RDSO/ SPN/197/ 2016 ver 1.0 or latest as per details given in technical specification.
1.00 465458.00 of Class-A protection with lighting event counter as per RDSO spec No. RDSO/SPN/197/2016 Ver1.0 and as per details given in technical specification. This shall include all the misc. material required for installation of the class A lightening arrestor which shall be installed at a height more than height of VHF antenna. Total 1098411.00
Item Breakup - A-Chapter -11
1.00 651840.00 commissioning of Datalogger as per RDSO IRS/99/2006 or latest with Power supply arrangement for data logger consists of 12V,42AH VRLA batteries-4 Nos and 10A charger 1 No, EI interface card (Digital interface cards)/ protocol converter, for 512 digital inputs and 32 analog inputs. This includes supply of all miscellaneous items and software for commissioning of datalogger with E1 networking. (including PC/laptop, printer, mounting table and revolving chair of reputed make).
Validation modification at site (Station)
Validation modification at central place. (Test Room). Total 706278.00
Item Breakup - A-Chapter -1
25.00 Lighting Unit Red with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
50.00 Lighting Unit Yellow with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
15.00 Lighting Unit Green with current regulator, as per RDSO specification No. RDSO/SPN/199/2010 revision 1.1 or latest.
70.00 Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
22.00 Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
70.00 Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
7.00 140mm dia, 4.6m tall as per latest specification IRS:S 6-81 Rev.3 or latest.
8.00 140mm dia, 3.6m tall as per latest specification IRS:S 6-81 Rev.3 or latest
7.00 Shoes to suit CLS pole 4.6m, as per latest specification.
8.00 Shoes to suit CLS pole 3.6m, as per latest specification.
15.00 Signal Pole 140mm dia as per latest specification.
2.00 of cast iron with necessary inspection as per latest specification.
10.00 of cast iron with necessary inspection as per latest specification.
8.00 assembly as per RDSO Spec. No. RDSO/SPN/194/2006 Rev .2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 08 Nos)
7.00 assembly as per RDSO Spec. No. RDSO/SPN/ 194/2006 Rev.2.0 or latest (Terminal box, mounting socket, hood, side flange and fixing bolt & nut, eye bolt, M12 bolt-3 Nos. and Fixing bolt 12 Nos)
15.00 foundation as per Drg.No.SG/SWR/052 using metallic templates, for erection of colour light signals up to 4 aspects. [Foundation bolts, cement, river sand, stone jelly of size 20/25mm dia and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
15.00 mounting of colour light signal up to 4 aspects complete on Signal pole/ Off-set bracket, (for LED/ filament bulbs) with lenses, triple pole lamp holder, filament switching units, CLS transformer, current regulators (whichever is applicable), fixing of ladder with platform complete and concreting of ladder shoe, fixing of number plates, marker board, lens guard, fixing of speed limit board wherever necessary,termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks, and painting of one coat of red oxide and two coats of aluminium/ enamel paints. When the aspect is fixed on Offset bracket using 'U' bolts and nuts, a through bolt shall be provided by drilling a hole in the signal pole to prevent the offset bracket from sliding down. ['U' bolts and nuts, through bolts and nuts, cement, stone jelly 20/25mm dia, river sand, Signal Collar-rings, wire PVC 3/0.75mm copper, lens-guard, all fixing bolts and nuts, lead wool, paints PVC/Nylon sleeves, enameled number plates. enameled marker boards, EWS locks, and all other miscellaneous materials for the work shall be supplied by the Contractor].
12.00 as per latest specification.
11.00 and nuts, erection of Calling On Signals/ 'A' marker lights, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock, number plates/ marker boards and painting. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Offset bracket from slipping down. (Supply of Calling On Signal/ 'A' marker light, LED aspects/holders & bulbs and Off set brackets is not covered in this item). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
10.00 complete with hood etc., as per latest specification. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
10.00 and nuts, erection of Post type shunt Signal, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting of one coat of red oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Post type Shunt Signals, LED aspects and Off set brackets is not covered in this item). ['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
4.00 complete with surface base, signal pole, hood etc., as per latest specification.
3.00 foundation as per Drg, No.SG/SWR/053 using metallic templates, for erection of Ground type colour light Shunt Signal. [Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor].
4.00 complete including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint. (Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this item). [Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor].
2.00 5 unit arm - 4 way with mounting sockets, as per latest specification.
2.00 - 4 way complete/ fixing of additional limb to the existing route indicators, termination of tail cables, wiring as per approved circuits diagram using wire PVC3/0.75mm copper, provision of required No of EWS locks, wire mesh, and painting. (Supply of junction type Route Indicators - complete and additional limb is not covered in this item). [3/0.75mm wire PVC, fixing bolts and nuts, EWS locks, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
5.00 arrangement for Signals in RE area as per standard practice. The work comprises of providing MS angle frame and wire mesh in order to avoid close proximity of OHE wires. The work also includes provision of earthing wire using 4 SWG GI wires from the screening arrangement up to surface base as per the instructions of Railway representative at site. [All materials required for this work shall be supplied by the Contractor].
5.00 existing signals very carefully without causing damage to the working cables and shifting the Signals along with the concrete foundations for approximately 1m to a nearby position so as to clear the infringement from the nearest track centre as instructed by Railway representative at site. The existing cable coils shall be released carefully so as to give access for shifting. Necessary masonry work and earth work shall be carried out in and around the signals after shifting as instructed by Railway representative at site. [All materials required for the work shall be supplied by the Contractor].
2.00 type Goods Warning Board as per practice & SEM (Angle/Rail is to be supplied by Railway).
4.00 type Calling- On/STOP/BSLB/Legend boards as per practice & SEM (Angle/Rail is to be supplied by Railway).
1.00 required lengths for Various Boards like Goods warning/Calling on/Axle counter & etc (1 PER UNIT= 1 PER TON)
30.00 fixing of markers of G/P/C/A/IB Module Markers/Number plates as per IRSEM DRG.No 19-D10 on MS sheet of thickness 3mm. Miscellaneous materials required for fixing is to be supplied by contractor.
20.00 Colour light Signals complete (upto 4 aspects) with or without Route Indicators, calling on signals, shunt signals etc., carefully without any damage to the gadgets, accounting and stacking them neatly at a place as instructed by Railway representative at site. The work includes breaking the concrete foundation, closing the resultant pit and resurfacing it by ramming and levelling. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
2.00 as per standard practice. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel paint on the Signals -complete as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. Total 3986206.00
Item Breakup - A-Chapter -21
3.00 Disconnecting terminals of Wago/Pheonix/Elmex make or similar.
3.00 disconnecting terminals of Wago/Phoenix//Elmex make or similar
5.00 conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 or latest for quad cable.
5.00 Shrinkable type complete for 6 quad cables. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specification No.IRS-TC 77/2012 Rev 3.0 covered in the supply portion has to be used for this purpose.] The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing
4.00 joint chambers with dry sand mixed with ant termite chemical as required in specification up to 400mm height and the cover is refixed in position.
& Section/Derivation OFC Joint enclosure including Splicing (24 Fibre) inside already prepared jointing pit. This does not include provision of Joint chamber, top plate & back filling. The joint Enclosure shall be as recommended in the technical specification
15.00 470:1120 ohms or 470:600 ohms or 470:470 ohms as per RDSO spec No. IRS-TC-76-2021 or latest.
1.00 167032.00 230V AC 50Hz input and 48V DC/25 Amps output in (2+1 configuration) suitable for VRLA battery as per RDSO specs: RDSO/SPN/TL/23/99 ver.4 or latest. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 152118.00 VRLA battery bank as per latest specification No.IRS-S93/96A [One set battery bank contains 24 nos of 2v/200AH cells].
4.00 testing of Rack/Wall mountable FDMS and termination IN and OUT 48 fiber OFC cables (with all connecting materials) routing/dressing fiber asper direction of engineer/In charge. This work includes termination/splicing of fibers and testing of fibers in the section/block and report of fiber to be submitted in hard and softcopy.
2.00 telephone (4Wire/2Wire) as per RDSO specification IRS: TC-78/2020 Ver. 1.1 or latest.
1.00 based way station equipment completes as per RDSO specification No.IRS.TC@45<47@93 and 4 wire control telephone with audio visual indication and reset button fitted on telephone conforming to specification No.IRS-TC@45&47@97 or latest. This work also includes supply and wiring of power supply arrangements for way station equipment conforming to specification IRS.TC.72/97. or latest [All the materials required for the work shall be supplied by the Contractor].
5.00 or simlar.
3.00 FRP type, conforming to specification RDSO/SPN/TC/44/2002 Ver. 3.0 or latest.
3.00 Spec. No. IRS/TC/42/20 Ver. 1.0 with latest
3.00 along the railway track. Fabrication of emergency post as per RDSO Drawing No. UBL/SG/CON/6/2004 and fixing of emergency socket post and burying the post to a depth of 1m after entry of cable. The post to be painted with red oxide before installation. This includes termination of derivation cables on termination strip inside the emergency socket, painting of emergency socket post with alternate black and white strips of 6'' width. The paint used should be of standard quality and two coats of paints should be applied. The EMC post should be painted with red oxide base before painting. (rails will be supplied by railways for the fabrication of emergency post)
1.00 Watts synthesized configuration VM-04 of bandwidth 136-174 MHz with DTMF microphone, of Motorola make model GM338/XiRM- 3688 or kenwood TK7360 as per latest specification HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 of 25 Watt VHF set with GP antenna and antenna cable of length 30 M, power supply and battery of 12V 65AH. This includes supply and fixing of GI pipe of suitable dia to the required height as per the guidance of the field engineer, wiring of antenna cable through PVC conduit. All the materials required for installation to be supplied by the contractor. VHF equipment, SMPS power supply, Antenna &antenna cable will be supplied by the Railways.
1.00 25-Watt VHF set
1.00 217U with silver tipped connectors on both ends, 30 meters length
1.00 mode Power supply unit of 12V/15Amps. for HF/VHF/UHF Transceiver.
1.00 Battery 12v/100ah Similar to Amar Raja make or better.
2.00 clock with GPS synchronization (stand- alone mode) as per RDSOSpec.No. RDSO/SPN/TC@47>47@2008 Rev 4.1 or latest with RED LED with complete installation including all necessary accessories as directed by Railway Site Engineer.
2.00 Clock with GPS synchronization as per RDSO Specification No RDSO/SPN/TC / 62 /2008 Rev 4.1 or latest. Including all the accessories required for the installations.
30.00 Mtrs length as per site requirements. (LS-SC, SC-SC, LC-LC, FC-FC patch cards as per site requirement) Total 915871.00
Item Breakup - A-Chapter -22
5000.00 by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation up to 100 Kms.
8000.00 by road as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. Transportation more than 100 Kms.
10.00 plank with thickness of 18mm, teakwood beading with three draws of size 4' X 2' with heavy duty S type chair with hand rest. The above is of Godrej or similar make
20.00 better with 2 keys. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 tool box of size 1000X750X100mm made of 25mm thick teakwood per splex sheet fronted 6mm (Colourless) fixed on the wall at a convenient location as instructed by Railway representative at site. The board should have provision of pad lock and locking arrangements and shall be equipped with the following tools[reputed make]: Digital Multimeter similar to Model No.Rish Multi 15S with suitable carrying case and test probes. Multimeter similar to Model No.HM 102 BZ Hungchung with test probes with suitable carrying case.- 1 No. Centre zero ammeter 30-0- 30 Amps - 1 No. Screw drivers of different types and sizes with common handle - 1 set Spanner double ended 33mm - 1 No. Spanners double ended 3/8x1/2" - 1 No. Spanners double ended 5/8x3/4" - 1 No. Spanners double ended 7/8x1" - 1 No. Hammer 1 1/2 lbs ball pane - 1 No. Hacksaw frame - 1 No. Adjustable screw spanner 12" - 1 No. Insulated cutting pliers- 1 No. Insulated nose plier- 1 No. Electric soldering iron 230V 60W Soldron/Philips make - 1 No. o. Electric soldering iron 110V 35W Soldron/ Philips make - 1 No. p. Megger 500V/ 500Mohms. with Probe - 1 No. The above tools shall be purchased from Reputed manufacturers only in consultation with the Railway representative at site. [Teak wood tool box made of 25mm teakwood plank, per spex sheet, all the tools mentioned above, padlock and other miscellaneous items shall be supplied by the Contractor]. Total 455542.00
Item Breakup - A-Chapter -18
Set HUBLI DIVISION-S AND T/SOUTH WESTERN RLY Design of SWRD in Auto Cad. Initially, contractor shall submit 3 copies for approval of Railways. One set will be returned duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by Railways. After carrying out changes, three Hard copies to be submitted for Railway Approval. After approval, Auto Cad copies to be submitted in USB pen drive along with approved copy in Tracing film and six copies of final approved drawing (Ammonia Print or print as approved by Railway) in properly bound booklet along with its scanned copy.
100.00 on the approved Signalling Plan as per RDSO Sig DATE Format. AutoCAD in A3 size. Initially, Contractor shall submit 2 set of documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or for re-submission for approval after incorporating the changes as required by railways. The TOC & Preliminary Check and Certification to be done by the IRSE or IRSTE (license holder). After carrying out necessary changes, two set of 'Hardcopies' are submitted for administrative approval. The final corrected drawings shall be supplied to Railways on 80/90 GSM Tracing film and 2 copies of blue print properly bonded booklets and the soft copy in USB Pen drive.
1.00 approval of Interface Circuits by IRSE/IRSTELO License holders for stations having up-to 25 routes.
1.00 134748.00 approval of Logic Circuits of stations of up-to 25 routes by IRSE/ IRSTELO License holders.
payment verifying and approval of Interface Circuits / Logic circuits having more than 25 routes by IRSE/ IRSTELO License holders. (Per Unit = Per Route Per Station ) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
1.00 117003.00 Core Plan, Cable Termination Rack Particulars, Location Box Particulars, Power Supply Diagram, Track Circuit Bonding Diagram and/or any other drawing on Auto- CAD in A2/A3/ A4, etc. size (as per instructions of Engineer in- charge). Initially Contractor shall submit 2 sets of 'AS PLANNED' documents complete for approval of Railways. One set is returned either duly approved for making a fair copy or fore-submission for approval after incorporating the changes as required by railways. After preliminary approval, execution of work shall be carried out at site. After Completion of work, 2 sets of AS MADE Check Prints are submitted for administrative approval. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respect along with its soft copies in USB Pen Drive and 6 sets of final completion drawings in properly bound booklets. [For Centralized Electronic Interlocking Stations/Small Stations]
100.00 AUTOCAD 2000 or latest (including contact numbers on the circuit) and submission of negatives in 80/90 gsm tracing paper in 'A3' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied to Railways on 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs. (Approved Signalling plan will be supplied by Railways for preparing table of control. Approved table of control will be supplied by Railways for preparing circuits diagrams). HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
of 'Asmades' of circuit diagrams, contact analysis charts, termination particulars of apparatus cases and cable termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall be submitted before Testing the circuits. The final negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back-to-back in one plastic cover) and handed over to Railways. Also, the contractor has to supply one set of As made in 'Reproduction Film'. The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incorporate the details of all the new wirings and alterations in the CD/ RP film and submit them to Railways. On approval 8 copies shall be made for As- made circuit diagrams also as mentioned above.
200.00 following Registers with latest proforma given by in-charge officer each register of 100 pages. Station Asset Register/Deficiencies Book/Officer Inspection book/ Work site orientation classes note book /Station Message book/Infringement measure book fog signal gears/Route cancellation register/Relay room Key register/Cable testing summary/Signal maintenance record register/Power Systems Battery maintenance Register/Mechanical Signalling Register/Axle Counter Maintenance Register/Block instrument Maintenance Register/Track circuit maintenance Register/Lifting barriers maintenance Register/Electrically operated point maintenance Register/Electronic interlocking Maintenance Register/Location box maintenance Register/Earth Testing record Register/Relay room register/Joint Inspection of Points and Crossings register/Block Proving Axle Counter Register/Diesel generator /SoIar panel Register (Per Unit = Per Register) Total 1401729.00
Item Breakup - A-Chapter -20
120.00 oriented Technical manpower to Days carryout works like drawing, computation, write up etc., using computer, using software like AUTOCAD, MS Office etc., between 08.00 Hrs and 20.00 Hrs of the day with all expenses of transportation, accommodation, food, consumables etc., with all ascents, descents, taxes, octroi, cess, fees, duties with contractors cost etc., as per special conditional/specifications/ regulations and as directed by Engineer-in-charge. Note: The person engaged for providing the services shall be convergent with computer working knowledge in above software's."
120.00 power to carry out Days miscellaneous/sundry works in the office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accommodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fess, duties, with contractors tools and plants, materials, consumables, labour, crew, machineries with all lead and lift etc., complete as per special conditions, specification, regulation and as directed by Railway Engineer-in-charge.
120.00 for loading/ unloading/stacking of Days departmental materials. Total 279720.00
Item Breakup - A-Chapter -4
10.00 110V AC as per latest specification No. IRS :S-89-2013 ver 1.0 or latest. Charger shall be of 10Amp output capacity suitable for charging 80AH battery and No. of Lead acid cells, 2/3/4.
50.00 RDSO specification No.IRS:S 65:83 version 1.0 or latest specification.
100.00 resistance disk type 0 to 30 ohms as per Drg.No.SA.20161/06/M or latest.
1000.00 groove 7mm dia. single groove as per specification IRS: S 17-75 Rev.3 or latest.
50.00 type with 4 terminals and stumps with necessary inspection as per latest specification/drawing.
100.00 complies to UL Thermistor standard 1434 with rating -2 Amps. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
14.00 circuiting Point zone to suit RE/Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLJB boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 Nos for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, B type choke and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLJB boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this item) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, B type choke, track relays, uncharged secondary cells (2V - 80AH), TLJB boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this item). [track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLJB boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
10.00 circuit in Other than Point zone to suit RE/Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLJB boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 Nos for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, B type choke and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. with Feed end/ Relay end details on the TLJB boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this item.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, B type choke, track relays, uncharged secondary cells (2V - 80AH), TLJB boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this item). [track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLJB boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
8.00 Feed end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor].
8.00 Relay end to suit RE/Non-RE standard as per approved signalling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re-wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sqmm cable, provision of TLJB boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLJB boxes, 2c x 2.5 sq.mm cable and TLJB boxes with stumps is not covered in the item. Existing Track relays, Track Feed Resistance, Track feed battery chargers, B type Chokes and Charged secondary Cells shall use for this work). [Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLJB boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. Total 720198.00
Item Breakup - A-Chapter -8
3.00 880mm x 2 Meters made out of 50mmx50mmx6mm thick MS angle with stainless steel nuts and bolts for fixing of the rack with POWDER COATED and drilling suitable holes to suit hylam sheet and relay frames complete as per standard practice with tripod bases and reel insulators (for K rack, P rack and power rack) and with cable ladder of width 400mm and length of 2 Mtr. The thickness of angle to be 5mm. two angles of 40mmX40mmX5mm to be supplied at both ends and supporting flats of 25mm X5mm.
3.00 suitably concreting tri-pod bases and reel insulators with "J" bolts and nuts. Tripod and other supporting are to be painted in 2 coats with enamel.
100.00 not less than 6mm thick and with an Foot insulation to with stand 650V AC, on the floor of relay room etc at places as indicated by railway representative at site.
2.00 glass fronted box of size 300mm x 600mm x 75mm with hooks to keep various keys with description engraved on the tags. [TW Glass fronted box of size 300mmx600mmx 75mm with built in lock, hooks, engraved tags and all other miscellaneous materials required for the work shall be supplied by the Contractor].
4000.00 power cables and internal wiring on terminal/ fuse blocks in cable termination Rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Hylam sheet 10 mm thick for terminal board, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves. After terminations are over, cable entry at the bottom shall be closed with, cement plastered, the inter-space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. Cable armour to be soldered to earth. (Supply of cable termination racks is not included in this item). [All bolts and nuts with washers, Hylam Sheet 10 mm Thick, cement, sand, stone jelly, Teak wood base, paints and all other miscellaneous materials required for the work shall be supplied by Contractor HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
120.00 boards of various sizes of various Foot drawings of Power diagram, Relay index chart, Station Rule Diagram, FTOT Particulars, yard layout diagram board etc, with different colours as per instructions of Site In-Charge/Railway Representative.
20.00 thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS cable tray including cover should be powder coated with Siemens gray color. -MS cable Tray - 400 * 300.
20.00 of thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS Cable Tray including Cover should be powder coated with Siemens Gray Color. -MS Cable Tray - 400 * 150.
20.00 of thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS Cable Tray including Cover should be powder coated with Siemens Gray Color. - MS Cable Tray - 250 * 100.
20.00 of thickness 1.5 mm, including top cover for closing, with all required miscellaneous materials for installation. Installation to be carried out as per the instructions of site engineer. MS Cable Tray including Cover should be powder coated with Siemens Gray Color. - MS Cable Tray - 100 * 100.
1.00 Crank Handle Cum Key Lock Relay Box (of MS Sheet) along with LEDs, with approved type push buttons, Wago or similar Disconnecting type Terminal Blocks including DIN rail etc., as per approved drawing. Installation, fixing and wiring of boxes for Key Lock Relays to be carried by Contractor's wiring and fixing material. The work shall be carried as per the instructions of site engineer.
100.00 disconnecting terminal block for 2.5 sqmm wire termination make: wago/elmex or similar with accessories & taxes. Total 1301571.00
Item Breakup - A-Chapter -6
3000.00 of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. (Laying of cables is not included in this item).
2000.00 of soil except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.5 Mtrs. (Laying of cables is not included in this item).
4000.00 Capping (RCC Duct) of size 700mm Length X 500mm Width X 260mm height & Suitable cover plate of 40mm thickness as per Drg.No.SDO/Cable laying/ 007 (Annexure-10) as detailed in document No. RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on signalling cable laying'.
5.00 colour Orange, width of 250mm (10") by printing with black letters 'Indian Railway Signal/Telecom/OF Cable' on both sides
3000.00 0.3m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
2000.00 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling
2000.00 Pipes (HDPE) of 110 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per latest specification No. IS 4984: 2016 with latest amendments and Material Grade: PE 80.
2000.00 10mm thickness along with collars in trenches at places of platform cutting etc and wherever required as per the instruction of site engineer.
200.00 not less than 30CMs in rocky terrain, concreting the trench with 150mm thick concrete with 1 cement, 2 sand, 4 grade stone 20mm nominal size. (All the materials are to be supplied by the contractor).
400.00 GI pipe/DWC/HDPE pipe in which cable is already laid to a size of 300x300mm with 1:3:6 mortar. (All the materials required for the work should be supplied by the contractor).
of Metre Signaling/Power/Telecommunication cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc. (Supply of cables is not included in this item). HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
200.00 capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/ Reservation office / Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor)
60.00 thick as per latest specification.
600.00 thick as per latest specification.
1500.00 120/103 mm dia, 2 meter long in already dug cable trenches. The unit of RMT means two split pipes of 1 Mtr each Material shall be supplied as per latest specification RDSO/SPN/204/2011 Ver.1.1 or latest.
360.00 dia) for cable laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry abutments work so that no cable is exposed, the work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this item). [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
3.00 Density Polyethylene Duct (PLB-HDPE), 40/33 mm Dia, along with End Cap, End Plug, Cable Sealing Plug and Couplers, as per RDSO/SPN/TC/45/2013 Rev.2 with Amd 3.0 or latest
3.00 Dia, in the trenches and in the protective works already provided including in HDD portion and supply pulling of Nylone rope through it at different places as per direction of engineer incharge or site engineer HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
direction without damage of surface road/track using Auger Machine (HDD machine). The bore shall be upto 200 mm dia& shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different dia DWC-HDPE pipe/GI pipes coupling etc. as per direction of Engineer Incharge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
200.00 Mtr. for track crossing of cables, laying of DWC/HDPE/RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench, it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item).
200.00 Mtr. for road crossing of cables, laying of DWC/HDPE/RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this item. (Supply of DWC/HDPE/RCC pipes with couplers/ collars is not included in this item).
200.00 parallel at a separation of 8 cms each to a depth of 150 mm and width will be as per site requirement in the platform surfaced/tiled floor for laying cable
300.00 DRG.No.SG/SWR/067 or latest guidelines. The lettering on the Cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.
300.00 size 300mmX300mm, casting of Concrete foundation of size 300mmX500mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road crossing. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
105.00 1.5mx1.5m and depth as instructed by Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and levelling. [Country bricks of size 220mmx100mmx60mm (approximately) shall be supplied by the Contractor].
300.00 slabs on the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. (Laying of cables is not included in this item). [Cement, sand and all other miscellaneous materials required for the work shall be supplied by the Contractor].
5.00 minimum 720P and above HD camera and submit one copy in New removable hard disks (With capacity as per requirement); Two copies in DVD-R.
500.00 as instructed by incharge SSE/JE at site. (Per Unit=Per cable)
448.00 pipe - 103.5mm inner dia& 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as specified in the Tender document.
200.00 rocky area/ hard soil including clearing of roots of tree, rocks, bushes etc. to a depth 0.6 m and to a width of 0.5 m and refilling of cable trench of 0.6 m depth by 0.5m width throughout, with earth after laying of cables, and consolidating the trench by ramming and levelling. Laying of cable is not included in this item. Total 14809992.00
Item Breakup - A-Chapter -10
200.00 Plug-In-Type, style QN1, 8F/8B Contacts, DC Neutral line Relay, working voltage 24V DC, metal to carbon, with plug board, retaining clip and connectors as per RDSO Specification No BRS:930, IRS: S: 34 & IRS: S: 23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABCDF HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
100.00 In-Type style QNA1, 8F/8B Contact, DC Neutral line Relay, working voltage 24V DC, metal to carbon with plug board, retaining clip and connectors as per RDSO Specification No BRS:931A, IRS: S@58<44@ IRS:S:34 & IRS:S:23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABDGH
20.00 Style QTA2 - 9 Ohm, 2F-1B Contacts, metal to carbon with plug boards, connectors and retaining clips as per RDSO specification No. BRS:939A & 966(Appx F2) & IRS:S 23-88 Amdt.1, S34 & 60, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be FGHKX.
20.00 in-type, style QBAT -9 Ohms, DC based track Relay, 2F/2B - contacts, Metal to carbon complete with plug board, retaining clip & connectors as per RDSO Specification No. RDSO/SPN/84-88, IRS:S:34 & IRS:S:23. The interlocking code for this unit shall be ABEJX.
30.00 type style "QSPA1" 8F/4B contacts, DC Neutral line Relay, slow to pick up, working voltage 24V DC, metal to carbon, complete with plug board, retaining clip and connectors as per RDSO Specification No. BRS:933A, IRS:S@58"44@ IRS:S:23; IRS S 60-78, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be ABDEJ.
20.00 type style QBCA-1, 2HF/4B contacts, DC Biased contractor Relay, Tractive armature, working voltage 24V DC with Heavy duty front contact, Metal to carbon complete with plug board, retaining clips and connectors as per RDSO specification No. BRS 943, IRS. S@46"44@ IRS.S.23
40.00 in type, Style QECX, 4F-4B Contacts, working voltage 110 V AC, metal to carbon for LED aspects with plug boards, connectors and retaining clips as per RDSO specification No: BRS:941A, STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amdt1, IRS S-23 & 34, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be ABDHK.
12.00 (KLCR) working on24V DC, AC Immunized with different ward combinations and contact configuration 4F/4Bwith 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 with amendment or latest, confirming to IRS S-23, S-34 & S@45<44@ IRS S:46. Total 2452056.00
Item Breakup - A-Chapter -17
50.00 (MSDAC): Supply, Design, Installation, Detection Testing and Commissioning of Multi Point Section Digital Axle Counter (MSDAC) (DP) complete system as per RDSO Specification No. RDSO/SPN/176/2013 version.3 with latest amendments STR No. SIQ 0001 Ver.2.0 or latest. MSDAC Reset procedure shall be as per SWR MSDAC Reset policy. Tenderer shall design the scheme for provision of required number of evaluators, reset equipment's, trackside junction boxes, detection points and track clearance relays etc and shall be submitted along with the offer. Remote Diagnostic System shall be provided at station. Length of the cable required for each DP and Rail Type will be specified at the time of issuing call Letter. [This also includes supply of 10% all types of spare cards, LV Boxes, Wheel sensors and other essential modules as specified in RDSO Spec, it shall be rounded to nearest integer subjected minimum of one item. One set of Specialized Tool and Measuring equipment's as per RDSO specifications shall be supplied. (Per Detection Point = DP) Total 19378050.00
Item Breakup - A-Chapter -7
6.00 strand copper conductor 10 Sq.mm (size of 140/0.3) Each coil length of 100 mts as per RDSO specification IRS.S 76/89 or latest.
200.00 conductor 16/02mm to ATC IS:694 to RDSO specification no.IRS.S76/89 Amendment.3 or latest. Each coil of 100 mts length. (Per Unit=Coil)
20.00 conductor 28/03 mm Each coil length of 100 mts as per RDSO spec No.IRS.S 76/89.
915.00 specification. Total 362366.00
Item Breakup - A-Chapter -14
2.00 height, 19" rack mountable, 4*E1 uplink, with 4 slots and supporting 8*EM (2W/4W), FXO/FXS and Ethernet card and one slot free for future expansion. Management supporting Telnet as well as NMS. Potential Free contact support. Uplink E1 supporting 4 direction paths as well as 1+1 protection. Unit supports DC (18-72VDC) as well as AC power. Make: MROTEK /CISCO/ MAPLE or similar.
2.00 channels Suitable to be accommodated in Integrated Multiplexer 1U height of MROTEK make or similar.
2.00 channels Suitable to be accommodated in Integrated Multiplexer 1U height of MROTEK make or similar.
card accommodated in Integrated Multiplexer 1U height of MROTEK make or similar.
2.00 Suitable to be accommodated in Integrated Multiplexer 1U height of MROTEK make or similar. Total 580418.00
Item Breakup - A-Chapter -2
30.00 per latest specification/drawing.
10.00 per latest specification/ drawing.
500.00 mm Centre, made up of PBT as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest.
50.00 as per RDSO Specification No. IRS.S.75/2006 (Rev.2) or latest.
40.00 wards as per requirement with key per E type lock to Drg. No. SA.3376IM/Latest and RDSO Specn. No. IRS. S.30/64. Rev.0. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
30.00 foundation and erection of Apparatus Case Full size as per Drg. No. SG/SWR/055 and fixing of 2 nos of "E" type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red oxide and two coats of aluminium paints, along with painting of termination and equipment particulars on the doors of apparatus cases as per instructions of railway representative at site. (Supply of apparatus case is not included in this item). [ Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the contractor].
10.00 foundation and erection of Apparatus Case Half size as per Drg, No.SG/SWR/056, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this item). [Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor]
2.00 existing Full location boxes very carefully without damaging the working cables and Shifting and turning the Full location boxes (Apparatus Cases) to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location boxes. Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected. [All materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
5000.00 power cables on25/60mm PBT terminals on phenolic sheet and internal wiring on terminal in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). { cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 - 1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, river sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
400.00 power cables on PBT fuse block on phenolic sheet and internal wiring on fuse blocks in new apparatus cases, cable termination boxes and in gate lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of phenolic synthetic industrial fiber base fine waves cotton fiber board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan painting of particulars on sleeves and also on the inner side of the doors of apparatus case. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter space filled with sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and fuse blocks is not covered in this item). ( cement, teakwood cable clamp 50mmX 50mm, base planks 100mm x 25mm, phenolic synthetic industrial fiber base fine weave cotton fiber sheet - 6mm thick to IS specification 2036 - 1995 - type F5, PVC / Nylon sleeves , varnish, paints, bolts, nuts, and washers, non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm X 100mm X 60mm, copper bus bars, brass screw, sand, wire PVC 3/0.75mm copper and other miscellaneous materials shall be supplied by the contractor) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
10.00 Frames of suitable size to Hold up to 4 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor].
15.00 Frames of suitable size to Hold up to 8 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036-1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item ). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
10.00 Frames of suitable size to Hold up to 12 relays /plug in type HMU as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars. (Supply of all types of relays, plug boards, connectors, retaining clips and plug in type HMU is not covered in this item). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, phenolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor].
10.00 Full size without disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor].
40.00 Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
5.00 (Full/ Half/ Quartersize) without damage after releasing the shelf planks, Terminal blocks, Fuse Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipment's, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site.
10.00 HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
10.00 foundation (a pit of size 400mm x 400mm x 1000mm is to be dig and cement concrete foundation in the pit in the ratio 1:3:6 to be casted) and fixing the frames/doors and E- type lock to the fencing with supplied material. The rail post/angular is to be erected up right in the foundation. All materials are to be arranged and used by the contractor (Rail post / angular /frames /Fencing/ E type locks will be supplied by railway). Cutting of rail post / angular / fencing to the required length, transportation to the site is to be done by the contractor.
earth boxes/signal foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Railway premises as instructed by Railway representative at site.
100.00 for every ten locks. Total 4202762.00
Item Breakup - B-SIGNAL (Non-SOR items)
Supply of Single mode RS485-OFC BI- Numbers DIR converter (M485OFBS-01) (Inspection: RDSO)
Supply of IOCOM CPU Card (M633OIC- Numbers 01) (Inspection: RDSO)
Supply of IOCOM Voltage and health Numbers monitoring card (M633OIC-01) (Inspection: RDSO)
Supply Input WFM CPU card (M633OCI- Numbers 01) (Inspection: RDSO)
Supply of OUTPUT WFM CPU Card Numbers (M633OCO-01) (Inspection: RDSO)
Supply of WFM Relay Driver card Numbers (M633ORD-01) (Inspection: RDSO)
Supply OCM (M633OVO-01) (Inspection: RDSO)
Supply of Power supply card Type -B Numbers (M633PSB-01) (Inspection: RDSO)
Supply of Power Supply Card Type-C Numbers (M633PSC-01) (Inspection: RDSO)
Supply of Single mode RS-485 OFC BI- Numbers DIR Converter (M483OFBS-01) (Inspection: RDSO)
Supply of 24V EMI Filter (M633EMI-01) Numbers (Inspection: RDSO)
Supply of OC Cardfiles, Enclosure with Numbers mounting arrangement, consisting of OC TOP & Bottom back planes (Two object controllers are accommodated in single enclosure) (Inspection: RDSO)
Supply of Relay racks, installation accessories (Inspection: RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of DC-DC converters for EI Numbers System incl spares (railway to provide stable 110V DC for EI) (Inspection: RDSO)
"Modification, Installation of additional Job EI hardware, Relay Rack, wiring, programming, testing and commissioning of EI system of Medha at Saunshi station for SWR as per RDSO Spec. No. RDSO/SPN/192/2019, in conneciton with loop line , provision of Calling on below in starter signals, NDKR1/RDKR1 modifiction & provision of MSDAC in paralle with DC track circuit. "
Excavation by Manual means in rock cum and very hard rock with hammer / chisel / pavement breaker etc. where blasting is not permitted due to special circumstances and if specifically ordered in writing including drilling and all incidental work in all conditions as directed by Engineerin-charge. (Without deduction of Equivalent Quantity of Normal Soil)"
Excavation by Manual means in rock cum and very hard rock with hammer / chisel / pavement breaker etc. where blasting is not permitted due to special circumstances and if specifically ordered in writing including drilling and all incidental work in all conditions as directed by Engineerin-charge. (With deduction of Equivalent Quantity of Normal Soil)
Alteration in existing Station Kavach/ Lumpsum TCAS (Inspection by RDSO)
Supply programming, verification and commissioning of RFID tags with enclosures and fixures at stations and block section (Absolute/ Automatic Block section). This should comply to RDSO/SPN/196/2020 Version 4.0 or latest. Inspection by RDSO
FAT/SAT Testing, dynamictrails, Pre- Job commissioning activities as per PCCL and Testing, commissioning of TCAS for the entire system.(1 Job = 250 KM) (13500000/250Km = 54000 per Km cost)
Preparation of application for Safety Kilometre Case by RDSO empanelled independent safety Assessor.
Supply mountable 48 Fibre management system (FMS) conforming to RDSO/SPN/TC3712000(rev-3) amdt-1 or latest similar to COMSCOPE make or better, suitable forsplicing and front patching 48F cable with all accessoriesand terminating the optical fibre cable with splicing and front patching in FMS in the equipment room. (OFC Pigtail patch chords of suitable length and all other materials required for splicing are to be supplied by contractor) (Inspection: RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply,Installation and Commissioning Set of Single Section Digital Axle Counter (SSDAC) Phase Reversal type as per RDSO Specification No.RDSO/SPN/ 177/2012 (Version-3) and latest if any along with Installation accessories as given in Annexure A enclosed. [SSDAC + Installation & Commissioning=8 Set WITHOUT TOOL KIT] (Inspection: RDSO)
Switch Plate lubricant - Cenolube 100 or Kg better NLGI 00 GRADE Black colored which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants & organo molybdenum disulphide to fill & lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal- tometal contact. It shall be designed to be hand applied providing a tough adherent Lubricant film with Tacky semi-dry finish reducing contaminant adhesion. The grease Should Not form a difficult to remove thick DRY film which requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates Four Ball Weld LOAD (ASTM- D2596) >600 Kg, Copper corrosion 24 hrs @ 100c (ASTM D 4048) 1a -2e packing Size 20 kg /25kg Drum.'(Inspection Agency- Consignee) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Installation of cenolube 100 Grease. Man- After cleaning of old oil and greece and Days re-lubrication of switch chair plate at point machine at interval of 15 days per point machine. Tightening of nuts check nuts and bolts lock nuts holding the detector slides lock slides with lugs. Workers are required to check for the tightness of the switch plates and points and clean the rust and dust apply Cenolube 100 grease on slide chaires & assembly up to 3 sleepers from the toe of switch. Rate per person for 3 persons to be deployed for 5 days time, so number of mandays is 3*5=15 days. (Inspection Agency- Consignee)
Supply Photo copier machine, model: Numbers Canon IR C3120 with DADF printing, scanning and duplexing features, palten / flat beded size A3, RAM-2048 (colour) (Inspection: Consignee)
Supply of Graphite base grounding Numbers minerals compound as per the specification (Inspection: RDSO)
Supply of fanless industrial grade Numbers embedded PC with Intel Core TM i3- 6100TE processor (Skylake / Kabylake), 4M cache, 2.70 GHz, Q170 Chipset, 2 x DP ports, 1 DVI ports, 8GB DDR4 RAM, 256GB SSD, 2x2Gbe LAN RJ 45, 2xM12 Bge Lan, 6 x USB 3.0 Ports, Audio line IN/Line out ports, Graphics controller: Intel HD P530/p630, supports Window 7, Window-10 IOT enterprises 2019, LTSC, Windows 11 and Linux operating sysystem, 9 to 48V DC input power, - 25 Deg C to 70 Deg operation, compliance or better as per RDSO compliance of Technical advisory note No. STS/E/TAN/3007, Ver 1.0 Dt 02.11.2012 (Inspection: Consignee)
Supply of 24/7, 4K signage VDU (QM Numbers 65C) Samsung or better (Inspection: Consignee)
Supply of Data Analyser as per the Numbers technical specification (Inspection Consigne)
Supply of multi torn Sounder cum Numbers strobe of more than 80dbA and more than 75cd provided with suitable fitting and accessories. Make" Siemens /Bosch/ Honeywell or better (Inspection: Consignee)
Supply of 2 pin socket - 5A with switch, Numbers fixing the same on the hardwood plank available and extending the 110VAC using wire PVC 3/0.75mm copper, in all the apparatus cases, as per the instructions of Railway representative at site. [2 pin socket - 5A with switch, wire PVC 3/0.75mm copper and all other miscellaneous materials required for the work shall be supplied by the Contractor]. HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of steel plain Almirah with 4 Numbers adjustable slaves size 1980mm height, 915 mm width,, and 485mmm depth make godraj storewel plain large or similar of reputed brand. (Inspection: Consignee)
Supply of chair RK Empire (RK-CMMST) Numbers (Inspection: Consignee)
Supply of Godrej Navtal Locks with Numbers diameter of 50mm with 3 keys. (Inspection: Consignee)
Supply of double wire signalling rope Kg (Galvanized) 6 x 19 as per Spen. No. IRS: S. 11/62 with latest amendements. The gavanized wires to be useful for making ropes with jute core. The tensile bgreaking strength 140/160 Kgs / m2 and the nominal dia of the wire shall be 6mm. (Inspection: Consignee)
Provision of Lookout person round the Per Unit clock in 12 hours shift beat from Up Home Signal to Down Home Signal to avoid theft of signalling assets.(PER UNIT = PER 12HOURS SHIFT)
Supply of Data Analyser (HP Intel Core Numbers i5 all in one PC with 21.5 inch display windows 11 professional) or latest as per the technical specification (Inspection: Consignee)
Supply of Ggroz Lever type with spring Numbers loaded follower Grease Gun (Inspection: Consignee)
Adding additional 35nos of inputs to the Numbers data loggers available at site and wiring
Alteration simulations in Data Loggers and all connected places (like HQ, FEP, STATION etc.,)
Recharging cost - Labour cost recharging the existing earth pit
Supply, commissioning of linear heat sensing cable as per RDSO/SPN /217/2018 ver-2 or latest (Inspection: RDSO)
Supply, commissioning of linear heat sensing interface module, (Monitor module) for LHS cable with backbox and all other accessories as per RDSO/SPN/ 217/2018 ver-2 or latest in complaince with IS standards and Underwriters Laboratory (UL) listed. (Inspection: RDSO) Total 24283304.39
Item Breakup - C-Telecom (Non-SOR items)
Supply of 32 channel 4K NVR with 4 Numbers HDD support Specification as per . RDSO/SPN/TC/65/2019 Revision 5.0 or latest Make-CP Plus /Securus / Bosch /Panasonic. (Inspection: RDSO)
Supply of HDMI Cable 5 metre Brand: Numbers CADYCE or similar or better (Inspection: Consignee) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of Power Supply Unit for Way Numbers Station Equipment with MF Battery 12 Volt / 7 AH as per RDSO Specification No IRS-TC-72/97 with Amdt. 1 or latest. Make Epsilon or similar or latest (Inspection: RDSO)
Supply of 8 Port FXS Gateway (AC Numbers based) including mounting kit and all the accessories. (Inspection: Consignee)
Supply of 12V/7AH SMF battery.Makes : Numbers EXIDE , Amaron or similar or better (Inspection: Consignee)
Supply of Webfil or similar make 2Mb Numbers programmable primary digital dropInsert Multiplexer as per RDSO SpecNo.IRS-TC- 68/2012 with latest with conference facility as per technical specifications and other tipulations of tender documents fully wired for 30 channels complete with power supply unit, remote control unit, supervision facility and all other common card accessories,installation materials,manuals etc. including the following combination of interface cards (1)2w/4w E&M/VF interface card (Min. 4circuits per card) X 4 Nos (Total 16circuits. (2) Exchange loop interface card (Min 4 circuits per card) x 1 No(total 4 circuits) (3)subscriber hot line interface card(Min 4 circuits per card)1 No (Total 4 circuits) (4) 64 Kbps G703 data interface card ( min 4circuits per card) x 1 No (Total 4circuits) (Inspection: RDSO)
Supply of cross connect Card (XA14OT5 Numbers ) for TJ1400 without any SFPs or accessories. (Inspection: RDSO)
Supply of STM-1 SFP Module with 15 KM Numbers range with all accessories for above routers (Inspection: RDSO)
SUPPLY OF 24U RACK specification Numbers given below.1.Depth of the Rack (mm)- Up to 1000.2.Mount Type - free standing.3.Secure Locks- Available.4.Support cable entry from top or bottom-Yes5.Numbers of Rack trays - 16.Number of Fan For Heat dissipation (nos)- 4.7.PDU Power Strips- Available.8..Type of glass used in front doorTransparent Toughened Glass. etc make:- Valrack/ ComRACK or similar. with minimum one year warranty (Inspection: Consignee)
Supply of 230V AC/48V DC operated Numbers Single channel Fiber to Ethernet media converter Built-in a 2-port switch that supports m odifi e d cut-through frame forwarding packet forwarding system. Supports bandwidth contro l supports IEEE802.3u 100Base-TX, 100Base-FX (Fast Ethernet, 100Mbps) Built in 128KB RAM data buffer Supports auto MDI- M D I X function Supports f a r e n d fault function LED display for link/activity. Make: DLink similar or better (Inspection: Consignee) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply of 20 Pair Krone Termination Box Numbers complete with mounting arrangements. 02 Nos of Krone Terminal modules of 10 ports each with back mount frame.Suitable to connect 0.6mm wire.Box made of MS Sheet of thicknes 0 . 8 m m ,powdered coated,with cable entry holes and washers.Lock and Key system (Inspection: Consignee)
Supply of Standard 19" Rack Mountable Numbers LER(Label Edge Router) , IP- MPLS Router with Redundant DC power feed - 48V DC nominal,equipped with interfaces: 2 x 10G (optical) SFP+ Ports along with 2 Nosof 40 Kms 10G SFP+ LC Modules, 4 x 1GbE (Optical) interface along with 4 Nos of 1GbE Single Mode Bi directional SFP (10KMs) Modules and 4 x 1GbE (Copper) interfaces & Modules and slot for 16 x E1 (G.703), {supply of 16 E1 card is not included in this item and is catered in item number A2 (4)}, Mounting kit with all necessary accessories & Software, Perpetual Licenses. As Per RDSO Document No. STT/TAN/IPMPLS/2020 Version 01 or latest. (Inspection: RDSO)
Supply of Standard 19" Rack Mountable Numbers Modular Chassis LSR (Label Switch Router) IP- MPLS Router with Redundant DC power feed -48V DC nominal Redundant Controller Card, equipped with interfaces: 8 x 10G (optical) SFP+ Ports along with 8 Nos of 40 Kms 10 G SFP+ Modules, Mounting Kit with allnecessary accessories & Software,Perpetual Licenses. As Per RDSO Document No. STT/TAN/IP- MPLS/2020 Version 01 or latest. Inspection RDSO.
Supply of 2 x 10G Adapter Interface Numbers without 10G SFP+ Modules for LER Routers. (Inspection: RDSO)
Installation o f 100/50/20 P a i r Krone Numbers Terminal Box as supplied vide NS items o n hard wood plank o f size 8"x13"x1" plank and wiring. Hard Wood plank and other materials like screws, bolts etc to be supplied by the contractor at his own cost.
Supply of 8 x 1G Adapter Interface (any Numbers combination: one nos of 8 x 1G or two nos of 4 x 1G) without SFP for LER Routers. (Inspection: RDSO)
Supply of 10G SFP+ Module with 40 Km Numbers range for above Routers. (Inspection: RDSO)
Supply of 1G SFP Module with 10 Km Numbers range for above Routers. (Inspection: RDSO)
Supply o f L 2 8 p o r t Gigabit Managed Numbers Network POE Switch with 2 S F P ports, Uplink, including SM-SFP Module with distance minimum 20 KM, Wave length: TX-1310nm, RX1550nm, 1.25Gbps speed.Should be certified b y Telecom trusted portal Make:DLINK or Netgear or similar or better. (Inspection: RDSO) HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply, Commissioning of Full HD Fixed Bullett type IP Colour Camera along with 128GB or Higher SD Card, housing and mount and all accessories required for installation purposes per RDSO Spec No RDSO/SPN/TC/65/2021 Version 6.0 with Amendment No. 3 or latest. (Detailed Specification in technical document) Inspection:RDSO
Supply and installation of 8 TB Hard Numbers Disk drive internal for CCTV for DVR/NVR of make: seagate or similar or better (Inspection: Consignee)
Supply and installation of 22 inch or Numbers higher Monitor with Power cable and adpter similar to Samsung LS24D304GAWXXL or better (Inspection: Consignee)
Supply a n d Installation o f Control IP Numbers Te l e p h o n e s with Hands Free and Gooseneck Operation for Way Side Station as Per Clause 11 of RDSO/SPN/TC/99/2012 Rev.2 or latest Supply a n d installation o f S I P Based B a s i c I P P h o n e with 128x64 Pixel Graphical LCD as per Specification (Inspection: RDSO)
Supply a n d installation of SIP Based Numbers B a s i c IP Phone with 128x64 PixelGraphical LCD as per Specification. (Inspection: RDSO)
Supply and installation of 2 KVA online Numbers UPS with Back UP :120 Minutes, Battery Capacity:6400VAH. Warranty for UPS (Years):- 3 Years or Higher. Make: Luminous similar or better (Inspection: Consignee)
Supply, Installation , Testing and Numbers commissioning of Managed Expandable Rack Type STM-1 ADM upgradable to STM-4 as per Technical specification no. TEC GR No.GR/SDH-04/04 JAN -11 or latest equipped with STM-1 L1.1 aggregate interface , 63E1's and minimum 4 no's of 10/100 Base-T Ethernet port , order wire,power supply unit, sub rack ,installation material and accessories manual etc . The equipment should be fully wired for its ultimate capacity and provide redundency for power supply. Model TJ1400 or better. (All the required cables and accessories are to be supplied by the contractor (Inspection: RDSO)
S u p p l y a n d installation o f 6 U wall Numbers mounting r a c k of reputed make with standard accessories as one tray, spike buster, fan tray etc (Inspection: Consignee)
Installation, Commissioning & Testing Numbers ofLER & LSR IP MPLS Routers including s u p p l y & In s ta lla t io n o f a l l the accessories like Power cable, Earthing Cable, Optical Patch Cords of 3 mtr- 4 Nos for LER & 8 Nos for LSR s, Cat 6 Patch Cords of 1 mtr -4 Nos ,one 6A MCB for each LSR and LSR ,wiring etc. as required for Routers HUBLI DIVISION-S AND T/SOUTH WESTERN RLY
Supply a n d Installation o f Standard 19 Numbers inch Rack Mountable Layer 3, 24 Port Managed Switch with 24 Nos of 10/100/1000 Ethernet Ports with POE + S u p p o r t and Redundant AC Power Supply, Dedicated Stacking Module 4 x 10 GE SFP+ Ports for uplink including 4 Nos of 10 GE BX SM SFP+ Modules, as p e r p a r a n u m b e r 4 . 0 o f RDSO S P E C I F I C A T I O N NO. RDSO/SPN/TC/83/2020 Re v 2 or latest. M o u n t i n g K i t w i t h a l l necessary accessories t o be supplied. [Detailed Specification in Technical Document] (Inspection: RDSO)
Supply and installation of 16 port E1 Numbers Card along with Patch panel/Krone Module and wiring for Routers with all accessories etc. (Inspection: RDSO)
Supply, Installation and Commissioning Numbers for 4 Port Gateway to support 4 Port Concurrent Emergency Communication at HQ/W a y station t o support 4 wire ports/ 4 Port Gatewaywith b u i l t i n 2 w i r e s t o 4 w i r e H y b r i d convertor to support 4 wire output a s Per Clause 13 of RDSO/SPN/TC/99/2012 Rev.2 or latest. (Inspection: RDSO)
P l a c i n g o f D W C HPDE/RCC/GI Pipes Metre along with collars in trenches a t places near track and road, crossing, platform cutting
Supply of MX LED cable network tester Numbers of make MX similar or better (Inspection Consignee)
Supply of PON power meter (ATTL) of Numbers make PON similar or better (Inspection Consignee) Total 4339193.24
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
6-Tenderbook_Hebsurver2.pdf
ATTACHMENT
1-IRGCC-2022with_ASC1TO11_compressed_1.pdf
ATTACHMENT
JPO CABLE CUT
ATTACHMENT
3-AnnexureVGCCcorrespondence_1.pdf
ATTACHMENT
4-TechnicalGuidelinesPCSTE.pdf
ATTACHMENT
5-ConservancyCharges.pdf
ATTACHMENT
7-TechSpecificationSignal.pdf
ATTACHMENT
8-TechSpecificationTele.pdf
ATTACHMENT
9-TenderSchwithInspectionclauseVER2.pdf
ATTACHMENT
2-JPO_CABLECUT_PCSTE_27122023_RLYBD_12062023.pdf
ATTACHMENT
Download all tender documents and submit your bid