Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 CrAccepted-AOC | ₹17.8 Cr Quoted ₹17.9 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹18.3 CrRejected-AOC 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹18.3 Cr | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹18.4 CrRejected-AOC | ₹18.4 Cr | L3 | Rejected-AOC NOT BEING LOWEST |
| 4 | L4₹18.8 CrRejected-AOC | ₹18.8 Cr | L4 | Rejected-AOC NOT BEING LOWEST |
| 5 | L5₹19.3 CrRejected-AOC | ₹19.3 Cr | L5 | Rejected-AOC NOT BEING LOWEST |
Tender Value
₹16.9 Cr
EMD Value
₹11.7 L
Closing Date
24 Sept 2022, 6:00 pmClosed
CHIEF ENGINEER CHENNAI ZONE
CHIEF ENGINEER CHENNAI ZONE ISLAND GROUNDS CHENNAI 600009
PROVN OF OTM ACCN FOR 400 RECTS ALONG WITH COOK HOUSE AND TOILETS AT ARTY CENTRE, GOLGONDA
2022_MES_543411_1
89057
Open Tender
Construction Works
547 days
GOLCONDA HYDERABAD
As per Tender documents
8 documents required · 8 mandatory
₹3,000
GARRISON ENGINEER GOLCONDA
₹11.7 L
Yes
21 Nov 2022
17 Aug 2022
26 Sept 2022
17 Aug 2022
24 Sept 2022
19 Sept 2022
17 Aug 2022 - 5 Sept 2022
Amount
Lump sum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lump sum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III
Lump sum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-IV
Lump sum price worked out by the tenderer for ROAD / PATH /CULVERT as listed in Schedule ‘A’ Part-V
Lump sum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI
Lump sum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII
Lump sum price worked out by the tenderer for COMPOUND WALL, FENCING AND GATE as listed in Schedule ‘A’ Part-VIII
Lump sum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-IX
Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-X
Lump sum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-XI
Lump sum price worked out by the tenderer for COOLING APPLIANCES as listed in Schedule ‘A’ Part-XII
Lump sum price worked out by the tenderer for SOLAR WATER HEATER as listed in Schedule ‘A’ Part-XIII
Lump sum price worked out by the tenderer for LIGHTNING PROTECTION as listed in Schedule ‘A’ Part-XIV
Lump sum price worked out by the tenderer for FIRE FIGHTING as listed in Schedule ‘A’ Part-XV
Lump sum price worked out by the tenderer for LIFT as listed in Schedule ‘A’ Part-XVI
SCHEDULE 'A' PART XVII (DIESEL GENERATOR SET 25 KVA) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only.
Supply, installation, testing and commissioning of 25 KVA/ 20 KW, (The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of 25 KVA Generator, developing 42 BHP @ 1500 RPM, Liquid Cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, sound proof canopy, integral fuel tank with battery and leads and accessories complete in all respect with CPCB approved acoustic enclosure suitable for ambient condition at Golconda, Hyderabad including required civil works (except Base for Generator) set as per manufacturers instruction and confrrming to conditions under IS 10004722/1460 BS 5514/2613/ 5000 ISO 8526/3046 complete all as per Item No 1 of SCHEDULE 'A' Part XVII (DG Set).
SCHEDULE 'A' PART XVIII (ROOF TOP SOLAR POWER PLANT ) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only.
Design, procure, erect, install, testing and commission of Roof top solar hybrid Photovoltaic inverter cum charger controller plant (Off-grid type with inverter and battery backup) of 10 KWp capacity including solar photovoltaic Module, DC cabling, Module Mounting Structures, Array Combining Boxes, Lightning Protection of SPV modules, Battery bank and other accessories, Central inverter as power conditioning unit all as per detailed specifications, latest MNRE/IREDA guidline and directions, meeting the Domestic Control Requirement (DCR) and consisting of all requisite accessories (BOS-Balance of System) and includig the following main equipments as described in Item No 1 of SCHEDULE 'A' Part XVIII (Roof Top Solar Power Plant).
SCHEDULE 'A' PART XIX (MECHANICAL LAUNDRY) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only.
Supply install test and commissioning complete mechanical laundry system, 30 Kg (Minimum), 3 phase 415 V, 50 Hz consisting of the following equipments with standard accessories and providing all necessary electrical and water connections as per latest Engineering practices required to make system functional complete all as specified and directed:-
Srl Item 19.00 Contd.... (a) Washing machine (Minimum 30 Kg Capacity):- Front loading and unloading type; Automatic Time, Temperature & Level digital control; Outer body, inner cylinder, loading door, outer drum & chemical dispenser all of stainless steel with non clog full clear port motorized drain valve; Minimum 318 Ltrs basket volume, High speed extraction with 0.75 KW (Min) wash motor, door opening dia minimum 450 mm, 9-18 KW electric heater as per OEM - 02Nos.
(b) Hydro Extractor (Minimum 30 Kg capacity):- Stainless steel construction (Cylinder & outer drum), Automatic DC injection brake digitally controlled, Direct drive & self balancing cylinder, Minimum 115 Ltrs cylinder volume, 950-1000 RPM cylinder speed as per OEM, 2.25 -3.75 KW Drive motor as per OEM- 02 Nos.
(c) Drying Tumbler (Minimum 30 Kg capacity):- Stainless steel Cylinder, Micro procecessor controlled with digital temperature control, reversible rotation, Minimum 600 Ltrs basket volume, Minimum 0.75 KW Drive motor and 0.75 KW Blower motor, door opening dia minimum 650 mm, 18-24 KW electric heater as per OEM - 02 Nos.
SCHEDULE 'A' PART XX(ELECTRICAL CHIMNEY) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only.
Design, Fabricate, Supply, install, testing and commissioning of complete Electical Chimney/Electrical Hood with filters comprising of following items:-
Supply, install, testing and commisioning of kitchen hood made of SS 304 matt finish 1 mm thick wall mounted type with removable grease stop and fixing brackets, oil drain channel of exhaust hood size 3ft x 20inch (900mm x 500mm) of required length including drain collector & connecting with exhaust ducting etc., complete all as specified and as directed.
Supply and install removable grease stop filters size 600mm x 500mm x 50mm complete all as specified and as directed.
Supply and install exhaust ducting of size 650mm x 650mm made of GI sheet 22 SWG including connecting with ceiling mounted exhaust hood up to terrace with MS angle frame 25x25x3mm thick, fixing of brackets with nut bolts, gaskets supporting thread rod, channels etc., including painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
Supply, install, testing and commissioning exhaust blower of capacity 7.5 HP, 440V, three phase 1440 RPM including starter, connecting with exhaust ducting and suitable electric copper cable connecting with starter ETC., complete all as specified and as directed.
Supply and installation collar damper of size 400x200x150 mm for connecting between duct and exhaust hood made out of GI 20 SWG with air control lever ETC., complete all as specified and as directed.
Supply and fix anti vibration bush with MS fabricated stand frame angle of size 50x50x5mm thick for resting blower complete all as specified and as directed.
SCHEDULE 'A' PART XXI (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only.
INTERNAL WATER SUPPLY
Supply and fix two way bib cock double handle 15mm bore, cast copper alloy, chromium plated with wall flange, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY
Supply and Fix 20W, decorative, wall mounted, ultra slim, polycarbonate, LED lighting fixture (605x66x76)mm, 6500K with high lumen output, environmental friendly, energy efficient with electronic driver complete all as per Cat No. STOUTPLUS600 BS20WLED840SPCWH of Havells or techno-commercially equivalent of other specified makes with all fixing arrangement etc., complete all as specified and as directed.
Supply and Fix 40W, decorative, wall mounted, ultra slim, polycarbonate, LED lighting fixture, (1205 x 66 x 76)mm, 6500K, with high lumen output, environmental friendly, energy efficient with electronic driver complete all as per Cat No. STOUT PLUS600BS40WLLED840SPCWH of Havells or techno-commercially equivalent of other specified makes with all fixing arrangement etc., complete all as specified and as directed.
Supply and Fix 10W Basic all purpose surface and wall mounted LED batten, 600x24x35mm with polycarbonate housing and integrated electronic driver complete all as per Cat No. LUMILINEBS10WLED865 SPCWH of Havells or techno-commercially equivalent of other specified makes with all fixing arrangement etc., complete all as specified and as directed.
Supply and Fix 3 Watts LED Bed side reading lamp, Aluminium body, , 230 volts with control switch adjustable, duly fixed on wall complete all as per Cat No.48042 of Philips or techno-commercially equivalent of other specified makes with all fixing arrangement etc., complete all as specified and as directed.
Supply and Fix CMRI Certified LED Flameproof/weather proof 1x20Watts LED tube light fixture all as per Cat No.EXTN1LT8-20 of Crompton or techno-commercially equivalent of other specified makes with all necessary fixing arrangements from ceiling rose to light fitting with 3 core flexible copper conductor cable complete all as specified and as directed.
Supply, fix, connecting and testing factory made, prewired Vertical type distribution board, (MCCB DB) TPN, 12 way, having degree of protection IP 43 with metal double door, 415 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 250 Amps rated copper bus bar all as per Cat No.DHDMTVOSRW12 of Havells or 5077 48 of Legrand or 811896 of Indoasian or techno-commercially equivalent of other specified makes with common neutral link earth bar, din bar for mounting MCBs, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCCBs, MCB TPN and MCB SP will be measured and paid separately.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) TPN, 4 way, having degree of protection IP 43 with metal double door, 415 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDNTHCDPW04 of Havells or 5076 70 of Legrand or 811840 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB TPN as incomer and 4P MCBs as outgoing and total number of modules equal to 4 + 12, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) SPN, 8 way, having degree of protection IP 43 with metal double door, 240 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDPSHODPW08 of Havells or 5076 11 of Legrand or 811807 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 2 + 6, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply, fix, connecting and testing factory made, distribution board, (MCB DB) SPN, 4 way, having degree of protection IP 43 with metal double door, 240 Volts, flush type made out of CRCA sheet metal, duly powder coated and conforming to IS 8623 with 200 Amps rated copper bus bar with neutral link all as per Cat No.DHDPSHODPW04 of Havells or 5076 10 of Legrand or 811805 of INDOASIAN or techno-commercially equivalent of other specified makes with provision for MCB SPN as incomer and SP MCBs as outgoing and total number of modules equal to 2 + 2, complete concealed and fixed flush to wall and making good the disturbed surfaces etc., complete all as specified and as directed. Note: MCBs will be measured and paid separately.
Supply, fix, connecting and testing MCCB, Four Pole, 200 Amps, 415Volts with breaking capacity 16kA, (lcs=100%lcu) with Adjustablle Thermal setting, conforms to IEC 60947 - II, suitable for isolation, fixed short circuit setting, adjustable overload setting lr=(0.8 to 1.0)xln all as per Cat No.830286 of INDOASIAN or techno-commercially equivalent of other specified makes etc., complete all as specified and as directed.
ROAD/PATH/CULVERT
Material and labour for preparing bituminous surfaces of road and marking centre lines, stop lines, dashes, arrows etc. and the like on roads pavements with hot applied thermo plastic compound 2.5mm thick of white, golden, yellow or black colour as required and confirming to BS 3262-1989 including reflectorising glass bead @ 0.25 Kg/Sqm as per IRC:35(1997) and as per Clause 803 of MORTH specification with special applicator machine fitted with profile shoe, glass beads dispenser propane tank heater and profile shoe heater with heating arrangement up to 160°C, driven by experienced operator all as per manufacturers' instruction etc., complete all as specified and as directed.
Supply and Fix road studs (cat eye) two way reflective type of size 100mm x 100mm x 26mm, made out of ABS Engineering plastic, dynamically designed having high impact strength all as per Model No. ECO 32 of Dark Eye or equivalent of other specified makes and fitted with 2 Nos. highly reflective reflectors on both sides, fixed with epoxy on bituminous /concrete surfaces as per manufacturer’s instructions complete all as specified and as directed.
SEWAGE DISPOSAL
Supply and laying 135/136mm internal dia (nominal size) DWC HDPE SN-8 pipes confirming to IS 14930 part-2 / IS 16025 Part-24 including all necessary specials, cutting and jointing as specified and directed.
EXTERNAL WATER SUPPLY
Material and Labour for Construction of valve chamber of internal size 900 x 900 x 900mm including necessary earth work excavation, 100mm thick PCC 1:4:8, type D2 using 40mm graded stone aggregate in foundation with 100mm offset, 200mm thick PCC solid block masonry walls built in CM 1:6, PCC 1:2:4 type B1 for coping, 15mm thick rendering in CM 1:4 for internal surfaces and external plaster up to a depth of 15cm below GL, including provision of 3.0mm thick MS sheet cover, double door, welded to 50 mm x 50 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1, 20mm x 6mm flat iron hinges with locking arrangement including lock sixty five mm, brassd and keys(Godrej/Shell), MS handles and applying two coats of synthetic eanmel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any kind of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 metre complete all as specified and as directed.
Supply, Fix, testing and commissioning of Centrifugal Monoblock pump set 5 HP/3.7kW single stage of 33-42 M Head, volute type delivery with CI Impeller, 2900 RPM, Stainless steel shaft, Gland packed, chrome steel shaft sleeve etc, electric driven 3 phase 430 volts AC 50 Hz with suction size 65 mm , delivery size 50mm dia all as per Kirloskar Model No. KDS-538+ or techno commercially equivalent of other specified makes including 3 phase, 10 Sqmm copper cable from Starter panel to Pump terminal box and suction pipe of suitable length from Foot valve to Centrifugal Pump etc., complete all as specified and as directed.
Material and labour for Construction of Pump base of size 1.20x0.60 Mtr (above GL 0.30 Mtr & 0.30 Mtr below GL) including excavation in trenches in any type of soil, PCC 1:4:8 type D2 bed concrete, PCC 1:3:6 type C1 for mass concrete for foundation/base, plastering in CM 1:4, 20mm thick and three coats white wash including PCC coping, and RFR , removal of surplus soil etc.,complete all as specified
Supply, lay and testing of Ductile Iron pipes of size 100mm bore with spigot & socket ends, cast special, class K9 conforming to IS 8329 with inside surface of centrifugally cast cement mortar lined suitable for tyton joint (Push-on joint) in any length laid to level or to falls in trenches/ on grounds / on supports including DI specials as required at site and jointing with flexible push-on type gasket of electrometric (EPDM) joining materials conforming to IS:5382 and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for the route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 400 mm dia for inserting branch connections etc complete all as specified and as directed. Note: (i) Excavation and earthwork, Returning, filling in and removal of soil shall be measured and paid separately under relevant items. (ii) Contractor is responsible for repair/replacement of any damages to the existing structures etc., during the course of execution.
Supply and fix Cast Iron foot valve of size 65mm swing type operation with rubber seat conforming to IS:4038 complete all as specified and as directed.
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board, 3 Phase, 4 wire system, plinth mounted outdoor type, double door front and back opening type, sloped canopy (Hood) on top extended 100mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade
colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Anle iron frame of 50x50x6mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded in PCC 1:2:4, type B1 45 CM below ground level and 15 Cm above ground level and consisting the following:- and testing and commissioning complete all as specified and directed and consisting the following :- (For pump house) (a) INCOMING : MCCB 4 Pole, 415 volts adjustable thermal & Magnetic type, 40 Amps with breaking capacity 16KA -01 No.
EXTERNAL ELECTRIC SUPPLY
Material and labour for Design Fabricating supply and errecting, connecting and testing totally enclosed LT cubicle panel board, 3 Phase, 4 wire system, plinth mounted outdoor type, double door front and back opening type, sloped canopy (Hood) on top extended 100mm all around, separate compartment for each control gear, cable alley, provision of knock out type plates for various sizes of cable in and out, incoming and out going feeders duly marked on revited plates etc complete CPRI approved factory made fabricated out of 3.15mm thick CRCA sheet duly treated through 7 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade
colour, built in industrial type locking arrangement on front and back, and pre wired with PVC insulated multi stranded copper conductor for controls and monitors, PVC sleeved aluminium strip for connecting MCCBs, Panel mounted on Anle iron frame of 50x50x6mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded in PCC 1:2:4, type B1 45 CM below ground level and 15 Cm above ground level and consisting the following:- and testing and commissioning complete all as specified and directed and consisting the following :-
Supply and fix cable junction box thermoplastic body IP 66, size 225mm x 295mm x 122mm suitable for halogen free and weather proof for out door installation with metric knockout for cable entry suitable for cable size 16-35 sqmm all as per Cat No.DK 3535 G of Hensel or techno-commercially equivalent of other specified makes including 01 No SP MCB single pole of capacity 5 to 30 Amps 240 Volts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron with bolts all specified and as directed.
Construction of Transformer foundation of size 1.80m x1.50m x1.50m (above GL) and 2.20m x1.90m x1.0m (below GL) including excavation in trenches in any kind of soil soil, PCC 1:4:8 type D2 bed concrete , Random Rubble stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick including PCC coping and RFR, removal of surplus soil and applying three coats white wash etc., complete all as specified
Construction of Generator base of size 3.0m x 1.5m, 0.75m height (above GL 0.45 Mtr & 0.30 Mtr below GL) including excavation in trenches in any kind of soil, PCC 1:4:8 type D2 bed concrete , Random Rubble stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick including PCC coping and RFR, removal of surplus soil and three coats white wash etc complete all as specified
COOLING APPLIANCES
Supply, install, testing and commissioning of Refrigerator of capacity 310/311 litres, electric driven, single phase, 230 volt AC, 50 Hz, Frost free, Energy Efficient BEE 5 Star rated all as per Model No.GL-D322JPZZ of LG or techno-commercially equivalent of other specified makes complete all as specified and as directed.
Supply, install, testing and commissioning of Refrigerator of capacity 190/195 litres, electric driven, single phase, 230 volt AC, 50 Hz, Frost free, Double door, Energy Efficient BEE 5 Star rated all as per Model No.GL-D201ABPZ of LG or techno-commercially equivalent of other specified makes complete all as specified and as directed.
Supply, install, testing and commissioning of Glass top Deep Freezer, single phase, 240 volt, 50 Hz electric driven, of capacity 320 litres etc., complete all as specified and as directed.
Supply and fix voltage stabilizers for automatic operation single phase naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with out put voltage stabilizer at 230 volts with accuracy of ± 2.5% and of capacity 1.0 KVA complete all as specified and as directed.
Supply, install, testing and commissioning of Desert cooler, Steel body, electric driven (single phase), 230 Volt, AC, 50 Hz, having nominal air flow capacity of 1250 CFM, tank capacity not less than 70 litre, collapsible louvers to prevent dust and insects, ice chamber, 3 speed control fan of suitable size with motor 1350 RPM, Auto fill system, water level indicator and thermal overload protector etc., complete all as specified and as directed.
FIRE FIGHTING SYSTEM
Supply and fix 63 mm dia RRL Hose 30 metre long rubber lined or rubberised fabric, confirming to IS:636 complete with male and female gun metal jointing coupling confirming to IS:903 duly binded with GI wire, rivets as required etc., complete all as specified as directed.
Supply and fix Fire Hose cabinet box of size 750mm x 600mm x 450mm, made out of 16 gauge MS Sheet with Full front glass door with 4 mm thick glasses and door frame made out of 16 gauge MS sheet and painted with powder coating fire red tint on out side and brilliant white on inside and mounted on masonry platform etc., complete all as specified and as directed.
Supply and fix Cast Iron Air Valves with single air outlets, conforming to IS 14845 of size 25 mm dia bore, class PN-1.6 with screwed ends, ISI marked having rubber floats etc., complete alll as specified and as directed.
Supply, installation, testing and commissioning of 9 Litre water stored pressure type wall mounted Fire Extinguisher with Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve complete in all respects including wall suspension bracket complete all as specified and as directed.
Supply, installation, testing and commissioning of ISI Marked CO2 type Fire Extinguisher 3 Kg capacity conforming to IS:15683:2006 squeeze grip operated light weight fitted with ISI Marked Controlled Valve, discharge adaptor and horn complete with initial gas charged with carrying handle wall mounting bracket, suitable for operating between - 30 degree C to + 55 degree C, Fire Rating Class - 13B complete all as specified and as directed.
Supply, install, testing and commissioning of Dry chemical powder, wall mounted Fire Extinguisher, ABC (Powder Type) of capacity 9.0kg with Mild Steel Cylinders ISI marked, conforming to IS:15683 fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC 90 powder (Mono Ammonium Phosphate) pressured by Nitrogen including wall suspension bracket as required etc., complete all as specified and as directed.
Supply, lay and testing LT cable PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor 1100 volts grade confirming to IS-7098 (Part-I) 1988 of size 2 core x 1.50 Sqmm complete all as specified and as directed.
EARTHING
Material and labour for Earthing complete with galvanized steel earth plate electrode of size 600mm x 600mm, 6.0mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5m below normal ground level, surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt, filling in alternate layer and earth plate connected to galvanized iron earth lead strip of size 32 x 6mm as earthing conductor by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical
plate No.3 of MES Schedule (Part I) (2009) connected to earth test point/ main switch/ DB all as specified including testing on completion with and including 40mm bore medium grade GI protection pipe upto 7.5 meter long for GI earth strip including PCC (1:3:6), type C-1 pit with 40mm thick precast RCC (1:2:4), type B -1 cover reinforced with 12mm dia MS bars @ 150 mm c/c both ways with lifting hooks made out of 12mm dia MS bars, wire mesh funnel with watering pipe 20mm dia medium grade, as specified including necessary excavation and earth work in any type of soil etc., complete all as specified and as directed.
For Fire fighting system : 04 For Lightening protection : 12 For External water supply : 02 For External Electric supply : 16 Panel boards, Transformer & DG set
SCHEDULE 'A' PART XXII (MANNING AND OPERATION OF LIFTS DURING DEFECTS LIABILITY PERIOD) Note: This schedule is not pre-priced by MES and the pre-priced rate left "BLANK" under column 5 signifies this fact only..
Notes for Items No.59.01 to 59.03 below:- (i) The outsourcing of operation of lifts by lift operator shall commence immediately after completion of entire work. (ii) Lift operator must have at least three years practical experience in lift erection and maintenance work or worked for five years as lift operator elsewhere in private sector. During emergencies, such as power failure, when lifts are trapped in between floors along with passengers, the operator must know how to release the passenger safely out from the lift at nearest floor landing. (iii) The lift operator must be available at lift site of 400 ORs Accn Arty centre during his eight hours duty time as specified. (iv) No payment will be made if lift operator absent and effective recovery @ Rs.1200/- shall be made for per shift per operator . (v) No escalations applicable to this schedule (Schedule 'A' Part XXII) and nothing extra shall be payable. (vi) Proper attendance register shall be maintained. (vii) Log Sheet in prescribed format as directed/suggested by Engineer- in- Charge/ GE will have to be arranged and maintained by contractor/firm for which no extra payment paid on this account. (viii) Lift operator must wear proper uniform with name of operator and firm name embroided. It shall be the responsibility of the contractor to provide uniform to operator with out any extra cost. Dress code shall be as approved by GE. (ix) The staff engaged by contractor shall be well behaved and polite. Any misbehaviour by any worker shall be taken up seriously. The concerned labour shall have to be removed immediately by the contractor and alternative arrangement for the same shall be made without any break. (x) Department shall not be responsible for any accident or injury to any labour while on work. It shall be the responsibility of the contractor to watch the welfare of the labour deployed by him. He shall keep a First Aid Box at site with all necessary medicines. (xi) The Contractor shall provide a Mobile phone (Kept at Lift Operator) with incoming & outgoing facility to contact in emergency during any breakdowns etc. (xii) Careful control on the plant and maintain clean and hygenic condition. (xiii) Any tradesman/employees shall not be allowed to continue their employment for more than 11 month.
Outsourcung for operation of Lift installed in 400 Rects OTM Accn to serve Four floors (Ground floor and Three upper floors) including operation all E/M inventory pertains to lifts in three shifts per day each consisting of eight hours shift including Sundays & Holidays by employing the man power of qualified Lift operator - 01 person per shift as per the following shift timings including reliver for weekly off for entire system comprising including maintenance of necessary records like log book etc complete for First year during defects liability period after physical completion, testing and taking over of Lifts by MES all as specified and as directed.
(a) Man power to be employed per day:- (i) Lift Operator - 02 Persons (One Lift Operator per shift of 8 hours each for 2 shifts) (b) Shift Timings :- (i) First Shift - 0600 hours to 1400 hours (ii) Second Shift - 1400 hours to 2200 hours
Outsourcung for operation of Lift installed in 400 Rects OTM Accn to serve Four floors (Ground floor and Three upper floors) including operation all E/M inventory pertains to lifts in three shifts per day each consisting of eight hours shift including Sundays & Holidays by employing the man power of qualified Lift operator - 01 person per shift as per the following shift timings including reliver for weekly off for entire system comprising including maintenance of necessary records like log book etc complete for the remaining period of First year and second year during defects liability period after completion of 11 months of handing over of plant by MES all as specified and as directed.
(a) Man power to be employed per day:- (i) Lift Operator - 02 Persons (One Lift Operator per shift of 8 hours each for 2 shifts) (b) Shift Timings :- (i) First Shift - 0600 hours to 1400 hours (ii) Second Shift - 1400 hours to 2200 hours
Outsourcung for operation of Lift installed in 400 Rects OTM Accn to serve Four floors (Ground floor and Three upper floors) including operation all E/M inventory pertains to lifts in three shifts per day each consisting of eight hours shift including Sundays & Holidays by employing the man power of qualified Lift operator - 01 person per shift as per the following shift timings including reliver for weekly off for entire system comprising including maintenance of necessary records like log book etc complete for the remaining period of second year during defects liability period after completion of 22 months of handing over of plant by MES all as specified and as directed.
(a) Man power to be employed per day:- (i) Lift Operator - 02 Persons (One Lift Operator per shift of 8 hours each for 2 shifts) (b) Shift Timings :- (i) First Shift - 0600 hours to 1400 hours (ii) Second Shift - 1400 hours to 2200 hours
VERMA BROTHERS
Teja Constructions
Sri Raghava Constructions Ltd
R. Wadhumal and Sons
N R Constructions
varsha construction
Dwarka Pershad Radhey Ramanlal
Indus Projects Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid