Superintending Engineer
Electricity Substation Design Circle-II, UPPTCL 13th Floor Shakti Bhawan Extn., 14-Ashok Marg, Lucknow
Construction of SAS based 2x40 MVA, 132/33KV Substation Jiyanpur, Azamgaeh on double Main and Transfer Scheme
2026_PTRCL_1212428_1
ESD-694
Open Tender
Construction Works
Turn-key
365 days
superintending Engineer ESDC-II
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,950
ICICI Bank A/C No 628105038318
₹21.1 L
25 Nov 2026
25 Nov 2026
18 Dec 2026
26 Nov 2026
17 Dec 2026
26 Nov 2026
180 days
Tender Specification no. ESD-694
Name of Bidder:
SCHEDULE OF QUANTITIES & PRICES FOR SUPPLY OF EQUIPMENTS/MATERIALS AND LIGHT LUMINAIRES FOR 2X40MVA, 132/33kV S/s JIYANPUR, AZAMGARH (SAS based on Double Main and Transfer Bus Scheme)
S. N. Item/ Equipments along with all accessories as per specifications Unit Tendered Qty. Unit FOR (Ex-Works, Packaging, Forwarding, Freight & Insurance Charges) Rate without GST (Rs.) Applicable GST Amount @ 18% (Rs.) Unit FOR (Ex-Works, Packaging, Forwarding, Freight & Insurance Charges) Rate with GST (Rs.) (5+6) Total FOR Destination Price with GST (4x7) (Rs.)
1.1 POWER TRANSFORMER,40MVA,145/36KV Nos 2 To be provided by UPPTCL
1.2 STATION TRANSFORMER,250KVA,36/0.420KV No 2
2 Circuit Breaker
2.1 SF6 CB,145KV,3150A,40KA Nos 6
2.2 VCB,36KV,2000A,31.5KA Nos 11
3 Current Transformer (CT)
3.3 CONNECTOR,CT,145KV,TWIN PANTHER Nos 36
3.4 JUNCTION BOX,CT,145KV Nos 6
3.5 CT,POLY,36KV,800-400-200/1A,3C,0.2S (with Terminal Connector) Nos 6
3.6 CT,36KV,400-200/1A,2C,0.2S (with Terminal Connector) Nos 30
3.7 JUNCTION BOX,CT,36KV Nos 12
4 Potential Transformer (PT)
4.1 PT,145KV,50VA Nos 12
4.2 CONNECTOR,CVT/PT,145KV,PANTHER Nos 12
4.3 JUNCTION BOX,CVT/PT,145KV Nos 4
4.4 PT,36KV,50VA (with Terminal Connector) Nos 6
4.5 JUNCTION BOX,CVT/PT,36KV Nos 2
5.1 ISOLATOR,145KV,CBR,1250A,MOTOR,W/1ES (LINE ISOLATOR) Nos 2
5.2 ISOLATOR,145KV,CBR,1250A,MOTOR,W/O ES (BUS ISOLATOR) Nos 10
5.3 ISOLATOR,TANDEM,145KV,HCB,1250A,MOTOR (TANDEM ISOLATOR) Nos 9
5.4 ISOLATOR,36KV,1250A,W E/S (LINE ISOLATOR WITH POST INSULATOR) Nos 8
5.5 ISOLATOR,36KV,1250A,W/O E/S (BUS ISOLATOR WITH POST INSULATOR) Nos 22
5.6 FUSE,DROP OUT (WITH POST INSULATOR) No 2
6 Post Insulator
6.1 BUS POST INSULATOR,145KV Nos 150
6.2 POST INSULATOR,36KV Nos 20
7 Surge Arrester
7.1 SURGE ARRESTOR,POLYMER TYPE,120KV Nos 12
7.2 SURGE ARRESTOR,POLYMER TYPE,30KV Nos 12
8 CRP & SAS (as per Technical Specification of SAS)
8.1 RELAY PANEL,UNDER FREQUENCY,145KV No. 1
8.2 C&R PANEL,TRANSFORMER,145KV Nos 2
8.3 C&R PANEL,SIMPLEX FEEDER,145KV Nos 2
8.4 C&R PANEL,BUS COUPLER,SAS,145KV No 1
8.5 PANEL,TRANSFER BUS COUPLER,145KV No 1
8.6 C&R PANEL,TRIPLE FEEDER,36KV Nos 3
8.7 SAS (Complete Set) LS 1
8.8 OPTICAL FIBER CABLE Lot 1
9 Battery & Battery Charger
9.1 BATTERY SET,LEAD ACID,110V,200AH Set 2
9.2 BATTERY CHARGER,110V,200AH No 2
10.1 DISTRIBUTION BOARD,110V,DC No 2
10.2 DISTRIBUTION BOARD,415V,AC,SWITCH YARD No 1
10.3 DISTRIBUTION BOARD,415V,AC,LIGHTING No 2
10.4 BAY MARSHALLING KIOSK,SWITCH YARD Nos 4
11 Capacitor Bank with all Accessories
11.1 2x5 MVAR, 33kV Capacitor Bank Unit Set 1
Simplex Type Control & Relay Panel for 33kV Capacitor Bank
VCB,36KV,2000A,31.5KA
3-Phase Reactor
CT,36KV,400-200/1A,2C,0.2S (with Terminal Connector)
JUNCTION BOX,CT,36KV
ISOLATOR,36KV,1250A,W E/S (LINE ISOLATOR WITH POST INSULATOR)
ISOLATOR,36KV,1250A,W/O E/S (BUS ISOLATOR WITH POST INSULATOR)
36kV NCT Ratio 5/1A
Terminal Connector for 36kV NCT
Junction Box for 36kV NCT
PT,3 PHASE,36KV
Terminal Connector for 3-Phase PT
12.1 1.1 KV PVC FRLS Unarmoured Copper Control Cable
12.1.1 CBL,CTRL,UNARM,PVC INS,CU,2CX2.5SQMM KM 15
12.1.2 CBL,CTRL,UNARM,PVC INS,CU,4CX2.5SQMM KM 20
12.1.3 CBL,CTRL,UNARM,PVC INS,CU,6CX2.5SQMM KM 15
12.1.4 CBL,CTRL,UNARM,PVC INS,CU,10CX2.5SQMM KM 12
12.2 1.1 KV PVC FRLS Unarmoured Alluminium Power Cable
12.2.1 CBL,POWER,UNARM,3.5CX400SQMM,1.1KV,AL KM 0.4
12.2.2 CBL,POWER,UNARM,3.5CX95SQMM,1.1KV,AL KM 1
13 Structure & Earthing Material
13.1 STRUCTURE,LATTICE TYPE (Galvanised Main & Auxiliary Structures with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc. and any other required materials) MT 200
13.2 ROUND,MS,40MM RM 5000
13.3 ELECTRODE,MS,40MM,3M Nos 300
13.4 FLAT,MS,75X10MM RM 2000
13.5 FLAT,MS,50X6MM RM 4500
13.6 FLAT,MS,25X6MM RM 3000
14 Energy Meter
14.1 ENERGY METER,3-PHASE,4-WIRE,ABT,0.2S Nos 24
14.2 METERING CUBICLE No 5
14.3 400/5A, 0.5s class for 250KVA, 33/0.415 kV station Transformer Nos 2
14.4 DATA CONCENTRATOR,DCU/COMM GATEWAY Nos. 2
14.5 CABLE,LAN Km 0.5
14.6 CONDUIT PIPE,PVC,FLXBLE,50MM Km 0.5
14.7 CABLE,FO,ARMRD,6CORE,W/HDPE PIPE,32MM Km 0.7
14.8 LIU,6 PORT,W/ACCS Nos. 6
14.9 SWITCH,NETWORK,8 PORT,6CU+2FO Nos. 2
14.1 CABLE,FO,ARMRD,6CORE,W/HDPE PIPE,32MM Km 0.5
15.1 CONDUCTOR,ACSR MOOSE KM 3
15.2 CONDUCTOR,ACSR PANTHER KM 3
16 INSULATOR,PORCELAIN,ANTIFOG,70KN Nos 2000
17 Hardware Fittings
17.1 Single Tension Fittings Suitable for
17.1.1 FITT,BLTD,SINGLE TENSION,MOOSE Nos 72
17.1.2 FITT,BLTD,SINGLE TENSION,PANTHER Nos 75
17.2 Single Suspension Fittings Suitable for
17.2.1 FITT,BLTD,SINGLE SUSPENSION,MOOSE Nos 36
17.2.2 FITT,BLTD,SINGLE SUSPENSION,PANTHER Nos 36
17.3 PG clamps suitable for -
17.3.1 PG CLAMP,MOOSE/MOOSE Nos 80
17.3.2 PG CLAMP,MOOSE/PANTHER Nos 150
17.3.3 PG CLAMP,PANTHER/PANTHER Nos 150
17.4 Bus Post Clamps suitable for-
17.4.1 CONNECTOR,BPI,PANTHER Nos 60
18 Fire Fighting equipments
18.1 FIRE EXT,MECH FOAM,50LTR Nos 5
FIRE EXT,DRY CHEM,IS 2171/1985,4.5KGS Nos 5
18.2 Fire Extinguisher carbon dioxide (CO2) as per latest IS
18.2.1 FIRE EXT,CO2,IS 2878/1986,22.5KGS No 5
18.2.2 FIRE EXT,CO2,IS 2878/1986,9KGS Nos 5
18.2.3 FIRE EXT,CO2,IS 2878/1986,4.5KGS Nos 5
18.3 SAND BUCKET Nos 30
18.4 STAND FOR SAND BUCKET Nos 3
18.5 ALARM,FIRE PROTECTION & DETECTION SYSTEM (SMOKE & HEAT DETECTION) LS 1
19 DG SET, 100 KVA,SILENT conforming to latest MoEFCC/CPCB guidelines Nos 1
20 GI perforated trays of various sizes for all cable trenches in switchyard, control room
20.1 CBL TRAY,PERFORATED,225MM Mtr 180
20.2 CBL TRAY,PERFORATED,75MM Mtr 300
21 Lighting and Luminaires
21.1 Supply of Complete fitting of Street Light Luminairs with LED Lamp 110 to 130 Watt, with all accessories (make Philips/CGL/Bajaj) Confirming to IP:65 Nos. 42
21.2 Supply of Complete fitting of Post Top Lantern with all accessories with LED Lamp 40 to 45 Watt (make Philips/CGL/Bajaj) Confirming to IP:65 Nos. 10
21.3 Supply of 15W LED Lamp (make Philips/CGL/Bajaj) Nos. 15
21.4 Supply of Complete fittings of 18/20 Watt LED Tube Light (make Philips/CGL/Bajaj) Nos. 50
22 TESTING EQUIPMENTS (UPPTCL approved-make)
22.1 Earth resistance tester (4 terminal digital type with data storage and retrieval) No. 1
22.2 Automatic testing kit for BDV measurement of T/F Oil No. 1
22.3 Earthfault Detection Meter No. 1
22.4 Thermal Imager Camera (640x480 px) No. 1
22.5 Digital Insulation Tester No. 1
22.6 Digital Multimeter (4 ½ Digit ) No. 1
22.7 Digital Volt Meter No. 1
22.8 Digital Clip-on Meter (0-300-600 A) No. 1
22.9 Self Supported Aluminium Ladder No. 1
22.1 Cartwheel Mounted Aluminium Ladder No. 1
23 Fiber Optic Terminal Equipment (FOTE) SDH (STM-16)
23.1 Base equipment suitable for 04 directions in subrack fully equipped with all necessary common cards, power supply cards, other hardware & accessories including 10 Nos. optical patch cords of lengths as per site requirements, DDF etc. with redundant CPU. No 1
23.2 Short Haul, STM-16, 1310nm SFP Transceiver - S16.1 Nos 2
23.3 Long Haul, STM-16, 1310nm SFP Transceiver- L-16.1 Nos 4
23.4 Long Haul, STM-16, 1550nm SFP Transceiver- L-16.2 Nos 2
23.5 E1 Interfaces (120 Ohm) ( 32 Interfaces with 2 Cards) No 1
23.6 L2 Ethernet Interfaces 10/100 Base T (16 Interfaces with minimum 2 cards) No 1
23.7 Equipment cabinet for SDH and DTPC 2200mm (h) including 100mm base, w x d should be suitable for 19" or 23" Rack (Alongwith 110V to 48V DC-DC Converter) No 1
23.8 MDF (200 Pairs), mounted in cabinet No 1
23.9 04 command standalone Digital Tele-Protection Cuupler (DTPC) fully equipped with necessary common cards power Supply Cards other Hardware accessories Connectors Cables Subtrack with E I path cords set of 04 etc. No 4
24.1 SECURITY SYSTEM,CCTV LS 1
25.1 AC,SPLIT,2TON,W/ACC&STABLIZER Set 14
Total (INR excluding GST)
Seal of Company
Full Signature ………………………………
Designation ………………………………
Tender Specification no. ESD-694
Name of Bidder:
HANDLING, ERECTION, TESTING & COMMISSIONING CHARGES FOR 2X40MVA, 132/33kV S/s JIYANPUR, AZAMGARH (SAS based on Double Main and Transfer Bus Scheme)
Sl. No. Item/ Equipments along with all accessories as per specifications Unit Tendered Qty Unit handling, erection, testing & commissioning charges without GST (Rs.) Applicable GST Amount @ 18% (Rs.) Unit handling, erection, testing & commissioning charges with GST (Rs.) (5+6) Total handling, erection, testing & commissioning charges with GST (4x7) (Rs.)
1.1 EREC 40 MVA,132/33KV TRF Nos 2
1.2 EREC 250KVA,33/0.4KV TRF No 2
2 Circuit Breaker
2.1 EREC OF 145KV CB Nos 6
2.2 EREC OF 36KV VCB Nos 11
3 Current Transformer (CT)
3.1 EREC OF 145KV CT Nos 18
3.2 EREC OF JB FOR 145KV CT Nos 6
3.3 EREC OF 36KV CT Nos 36
3.4 EREC OF JB FOR 36KV CT Nos 12
4 Potential Transformer (PT)
4.1 EREC OF 145KV PT Nos 12
4.2 EREC OF JB FOR 145KV PT Nos 4
4.3 EREC OF 36KV PT Nos 6
4.5 EREC OF JB FOR 36KV PT Nos 2
5.1 EREC OF 145KV LINE ISO W/1ES Nos 2
5.2 EREC OF 145KV BUS ISO Nos 10
5.3 EREC OF 145KV TANDEM ISO W/1ES Nos 9
5.4 EREC OF 36KV LINE ISO Nos 8
5.5 EREC OF 36KV BUS ISO Nos 22
5.6 EREC OF 36KV DROP OUT FUSE SET No 2
6 Post Insulator
6.1 EREC OF 145KV POST INSULATOR Nos 150
6.2 EREC OF 36KV POST INSULATOR Nos 20
7 Surge Arrester
7.1 EREC OF 120KV LIGHTNING ARRESTER / SURGE ARRESTOR Nos 12
7.2 EREC OF 30KV LIGHTNING ARRESTER / SURGE ARRESTOR Nos 12
8 CRP & SAS (as per Technical Specification of SAS)
8.1 EREC OF UNDER FREQUENCY RELAY PANEL Nos 1
8.2 EREC OF RELAY/CONTROL PANEL PWR TRF Nos 2
8.3 EREC OF RELAY/CONTROL PANEL FOR FDR Nos 2
8.4 EREC OF RELAY/CONTROL PANEL BUS COUPLER No 1
8.5 EREC OF RELAY/CONTROL PANEL TBC No 1
8.6 EREC OF 33KV TRIPLE FDR CRP Nos 3
8.7 EREC OF SAS PANEL LS 1
8.8 EREC OF OPTICAL FIBRE FOR SAS Lot 1
9 Battery & Battery Charger
9.1 EREC OF 110V BATTERY SET Set 2
9.2 EREC OF 110V BATTERY CHARGER No 2
10.1 EREC OF 110V DCDB No 2
10.2 EREC OF 440/415V ACDB No 1
10.3 EREC OF LIGHTING DIST BOARD No 2
10.4 EREC OF BAY MARSHALLING KIOSK Nos 4
11 Capacitor Bank & its Accessories
11.1 Erection of 2x5 MVAR, 33kV Capacitor Bank alongwith Vacuum Circuit Breaker, 3-phase reactor, CT, NCT, PT, Isolators, Control & Relay panel and all other required items (COMPLETE IN ALL RESPECT) Set 1
12.1 1.1 KV PVC FRLS Unarmoured Copper Control Cable
12.1.1 LAYING 2CX2.5SQMM UNARM CTRL CABLE including Terminations of cables (COMPLETE IN ALL RESPECT) KM 15
12.1.2 LAYING 4CX2.5SQMM UNARM CTRL CABLE including Terminations of cables (COMPLETE IN ALL RESPECT) KM 20
12.1.3 LAYING 6CX2.5SQMM UNARM CTRL CABLE including Terminations of cables (COMPLETE IN ALL RESPECT) KM 15
12.1.4 LAYING 10CX2.5SQMM UNARM CTRL CABLE including Terminations of cables (COMPLETE IN ALL RESPECT) KM 12
12.2 1.1 KV PVC FRLS Unarmoured Alluminium Power Cable
12.2.1 LAYING 3.5 core * 400 sq. mm including Terminations of cables (COMPLETE IN ALL RESPECT) KM 0.5
12.2.2 LAYING 3.5 core * 95 sq. mm including Terminations of cables (COMPLETE IN ALL RESPECT) KM 1
13 Structure & Earthing Material
13.1 EREC,STRUCTURES, MAIN/AUX, INCL ACCS: with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc. and any other required material MT 200
13.2 LAYG MS BAR 700MM-40MM DIA 40mm for Main Earthmat RM 5000
13.3 LAY,ELECTRODE,MS ROUND,40MMX3M,BLW GND 40mm Dia MS Electrode (3 M Long) Nos 300
13.4 FRESH EARTHG,W/FLAT,75X10MM RM 2000
13.5 FRESH EARTHG,W/FLAT,50X6MM RM 4500
13.6 FRESH EARTHG,W/FLAT,25X6MM RM 3000
14 Energy Meter
14.1 EREC OF ABT ENERGY METER Nos 24
14.2 EREC OF ABT ENERGY METERING PANEL with one main & one check rack No 5
14.3 INSTALLATION,DCU/GATEWAY/ETC including installation of Network Switch-16 Port, (14Cu+2 FO with FO Communication module (industrial frade), LIU (Light Interfacing Unit) with patchcord & accessories, Network Switch-08 Port, Data Concentrator (DCU)/ Communication Gateway (IG), laying of Lan Cable, PVC Conduit Pipe-3/4, OFC Cable Armoured (6P), HDPE Conduit Pipe 32mm Lot 1
15 Stringing of Conductors
15.1 Stringing of Bus bars comprising of Conductors Tension & Suspension stings complete with anti fog type disc insulators, tension & suspension clamps, PG clamps, Bus post clamps, connectors, earth wires and all other required material for KM 2.5
15.2 132 KV Main Bus I & II Lot 1
15.3 132 KV Transfer Bus Lot 1
15.4 132 KV Jack Bus for-
15.5 Feeder Lot 1
15.6 Power Transformer Lot 1
15.7 Bus Coupler Lot 1
15.8 33 KV Main Bus Lot 1
15.9 33 KV Auxilliary Bus Lot 1
15.1 JUMPERING TRF & ASSOC. EQUIP. Baywise interconnection of equipments with specified conductors ( jumpering ) for complete substation including but not limited to: 1. 40/63 MVA Transformer bay including 132 KV &33KV side bays 2. 132 KV Feeder Bay 3. 132 KV Bus Coupler Bay 4. 132 KV Transfer Bus Coupler Bay 5. 33 KV Feeder Bay 6. 33 KV Bus Coupler Bay 7. 33 KV Bay for station Transformer (COMPLETE IN ALL RESPECT) LS 1
16 Fire Fighting equipments
16.1 EREC OF FIRE FIGHTING SYSTEM (COMPLETE IN ALL RESPECT) JOB 1
17.1 EREC OF DG SET conforming to latest MoEFCC/CPCB guidelines No 1
18.1 INSTALL,TRAY,CABLE,INCL FABRICATION/ETC LS 1
19 FOTE Equipments
19.1 ERECTION/LAYING/T&C,STM-16,FOTE Erection of Fiber Optic Terminal Equipment (FOTE) SDH (STM-16) including but not limited to installation /erection of : 1. Base equipment suitable for 04 directions in subrack fully equipped with all necessary common cards, power supply cards, other hardware & accessories including 10 Nos. optical patch cords of lengths as per site requirements, DDF etc. with redundant CPU. 2. Short Haul & Long Haul 3. E1 Interfaces & L2 Etherner Interfaces 4. Equipment cabinet for SDH and DTPC 2200mm (Alongwith 110V to 48V DC-DC Converter) 5. MDF (200 Pairs), mounted in cabinet 6. 04 command standalone Digital Tele-Protection Coupler (DTPC) fully equipped with necessary common cards power Supply Cards other Hardware accessories Connectors Cables Subtrack with E I path cords set of 04 etc. (COMPLETE IN ALL RESPECT) LS 1
20.1 EREC OF CCTV Camera System (COMPLETE IN ALL RESPECT) JOB 1
20.2 EREC OF AC System (COMPLETE IN ALL RESPECT) Set 14
21 LIGHT LUMINAIRES
21.1 OUTDOOR LIGHTING
21.1.1 PERIFERY AND ROAD LIGHTING
a Supply and fixing of steel round pole 9.0 mt long in 1:4:8 cement concrete with 40mm brick ballast in size of 450x450x1900 and plastering of 300mm length of concrete above ground level No. 10
b Supply of junction box of size 280x225x150mm made of 16 SWG sheet with grey painting suitable for 2x4x6 C sq mm incoming cable & 2x4x6 C sq mm out going cable fitted with 3 Nos. HRC Fuse link of 5A, Cable glands, neutral link, terminal block etc. and Fixing of junction box on M.S. round pole with the help of M.S. Clamp No. 10
c Fixing of complete fitting of light luminaries with LED Lamp 110 to 130 Watt at designated height on light pole including taking out cable from junction box to light fixtures from inside pole. cable terminations and it’s testing and commissioning and earthing with 12 No. SW GI Wire No. 10
d Supply & fixing of GI pipe bend of 35mm dia 'B' class 2.5 meter long and bended at one end by quarter circle in 0.5 meter for cable entry to junction box fitted on steel round pole No. 10
e Painting of M.S. Round pole with first quality Asian /Nerolec/Burger paint, one coat of Red Oxide primer and two coats of Aluminium paint. No. 10
f Making 3 Nos. of strips of 450mm height from plinth with Post Office red colour in bottom & top and white colour in middle on each light pole of 150mm dia on M.S. Round pole and writing No. of pole. No. 10
21.1.2 SWITCHYARD LIGHTING
a Supply of junction box of size 280x225x150mm made of 16 SWG sheet with grey painting suitable for 2x4x6 C Sqmm incoming cable & 2x4x6 C sqmm out going cable fitted with 3 Nos. HRC Fuse link of 5A, Cable glands, neutral link, terminal block and Fixing of junction box on Columns with the help of 50x6mm G.I. Clamp No. 30
b Supply and fixing of GI pipe bend of 35mm dia 'B' class 2.0 meter long and bended at one end by quarter circle in 0.5 meter for cable entry to junction box fitted on column No. 30
c Supply and fixing of Light bend of 50mm dia GI 'B' class pipe 1.5 meter long bended at 1 meter at an angle of 300 for 250W HPSV light in Switchyard. No. 30
d Fixing of complete fitting of LED 110 to 130 Watt light luminaries at designated height on Column with the help of GI clamps & Light Bend cable terminations and it’s testing and commissioning and earthing with 12 No. SW GI Wire. No. 30
21.1.3 LAWN LIGHTING
a Supply & fixing of 'B'type light pole 2.5M long and fixing of cable bend pipe & its concreting in the ratio of 1:2:4 with 20mm stone granite and cement concrete in the size of 500x300x300mm including excavation, back filling, curing etc. to complete the job No. 5
b Supply of Junction Box of size 180x150x100mm made of 16 SWG steel with grey painted suitable for 2x2x6 C Sqmm cable fitted 2 Nos. HRC Fuse link of 5A & 1 No. Neutral link terminal block, cable glands etc and fixing of junction box on light pole with the help of M.S. clamps and then making plinth of size 225x300x300 in the ratio of 1:2:4 cement & coarse sand with 20mm granite with JB embedded in the plinth and the top surface of plinth being tapered from all four sides of plinth with 30mm height in the centre including all associated works of finishing, plastering etc. No. 5
c Supply & fixing of 50mm dia GI pipe light pole of 'B' class quality No. 5
d Supply & fixing of 'J' bend of 25mm dia GI pipe of 'B' class for cable entry No. 5
e Assembling and fixing of complete fitting of post top lantern with LED Lamp 40 to 45 Watt over the light poles, cable terminations, testing & commissioning etc. No. 5
f Making 3 Nos. of strips of 150mm height from plinth with Post Office red colour in bottom & top and white colour in middle on each light pole of 50mm dia No. 5
21.1.4 GATE LIGHTING
a Supply & fixing of junction box of size 180x150x 100mm as specified above at si.no. C_2 No. 4
b Assembling and fixing of Complete fitting of post top lantern with LED Lamp 40 to 45 Watt with cable terminations, testing and ,commissioning No. 4
21.1.5 CABLE LAYING AND TERMINATIONS
a Laying of 4cx2.5 sq mm copper control cable from control room to various point and for lawn lighting in excavated trench M 100
b Laying of 2cx2.5 sq mm Copper control cable for lighting in switchyard periphery, road etc. in excavated trench M 500
c Taking out above cable from junction box to light fittings fixed over the column by fixing GI clamps of 40x5mm flat with each crossed bracing on structures proper dressing etc M 500
d Excavation of trench of size 300 x 600 mm for laying of cable, putting ganga sand & Ist class bricks over the cable and then earth filling etc. 500
f Supply & fixing of Cable marker made of cast iron No. 60
21.2 INDOOR LIGHTING FOR CONTROL ROOM AND STORE
a Wiring for light point/fan point/ Exhaust Fan point/Call bell point with 3/22, 1.5mm2 PVC insulated copper conductor in PVC conduit concealed in wall with 2.24mm dia bare copper earth continuity wire & piano type switches etc. complete in all respect. Nos. 70
b Wiring for 3 Pin 5A light plug point socked outlet on existing switch board with 3/22, 1.5mm2 PVC insulated copper conductor in PVC conduit concealed in wall with 2.24mm dia bare copper earth wire continuity along with piano type switch complete in all respect. Nos. 12
c Supply and fixing of metal box of size 180x100x80mm deep in recess with suitable size of white laminated sheet cover in front including providing & fixing 3 pin 15 A socket & switch connection piano type with 7/22, 4.0mm2 PVC insulated copper conductor concealed in wall with 2.24mm dia bare copper earth wire continuity complete in all respect. Nos. 8
d Supply & wiring of sub main with PVC insulated copper wire of size & no. as detailed below along with 2.24mm dia bare copper earth wire continuity in PVC conduit concealed in wall complete in all respect.
e 2x4mm2 with 1 No. earth wire M 40
f 4x4mm2 with 2 No. earth wire M 30
g 2x1.5mm2 with 1 No. earth wire M 40
h 4x1.5mm2 with 2 No. earth wire M 50
i Supply & fixing of angle/button holder suitable for LED Lamps complete in all respect Nos. 8
j Supply & fixing of Factory Wired in-door decorative luminairs with LED Lamp for ceiling mounting with mirror optic suitable for 2x20/2x18W LED complete in all respect of category 'A' (make Philips/CGL/Bajaj) Nos. 8
k Supply & fixing of factory wired in-door decorative luminairs for surface mounting with oval polystyrene diffuser suitable for 1x20/1x18 W LED Lamp complete in all respect of category 'A' make.(make Philips/CGL/Bajaj) Nos. 10
l Supply & Fixing of complete set of street light luminair with LED Lamp 110 to 130 Watt complete in all respect with integral control gear of category 'A' make.(make Philips/CGL/Bajaj) Nos. 3
m Supply & fixing of factory wired LED light fitting suitable for 1x20W LED complete in all respect of category 'A' make.(make Philips/CGL/Bajaj) Nos. 10
n Supply & Fixing of Fancy wall bracket 1x15W LED fittings Nos. 12
o Supply & Fixing of decorative ceiling luminairs for 1x10W LED Lamp complete with round twin PVC insulated flexible cord, approved holder complete in all respect with bulb for DC lighting Nos. 7
p Supply & Fixing of 1200mm ceiling Fan complete with electronic regulator with double ball bearing and approved colour of category 'A' make as approved by Engineer. Nos. 10
q Supply & fixing of 18" Exhaust fan of category 'A' make as approved by the Engineer. Nos. 4
r Supply & Fixing of 12" Fresh Air Fan of category 'A' make as approved by the Engineer Nos. 4
s Supply & fixing of 6000 capacity Desert cooler of size made of 20 SWG galvanized sheet duly wired fitted with 18" Exhaust fan of cat 'A' make and vertical pump along with stand & other thing required to complete the jobs satisfactorily. Nos. 2
t Supply and fixing of Four Pole Isolator of 60/63 A. No. 1
u Supply and fixing of surface/flush mounting 8 ways SPN Distribution board with MCB complete in all respect. No. 1
v Supply & fixing of Call bell of approved make on white laminated sheet board including making connection etc. complete in all respect. Nos. 1
w Supply & Fixing of 600x800x8mm GI plate vertically for earthing with its top at least 3M below the ground level complete with 20mm dia GI pipe & funnel for watering and one earthing lead of one No. 8 to 10 SWG GI wire within 15mm dia GI pipe up to switch board 30cm square CI frame with hinged cover masonry housing alternate layer of charcoal/coke and salt at least 150mm thick alround etc as per direction of Engineer complete in all respect Nos. 1
x Supply & Fixing of Distribution box 6 bay TPNDB with 100 Amp. Isolator and 18 No. SP MCB of different capacity Havells make. Nos. 2
Total (INR excluding GST)
Full Signature ………………………………
Seal of Company
Designation ………………………………
Tender Specification no. ESD-694
Name of Bidder:
Bill Of Quantity Construction of Main Gantry, Aux. Foundation, Cable Trenches,Transformer Foundation, Fire wall, Capacitor Bank, C.C. Road, Culvert, Control Room Building, Gate, Sump House, Chain link Fencing, Drain, Tube Well Boring, Water supply works, Park & Plantation and Miscellaneous Work at 132/33 kV Sub Station Jiyanpur, Azamgarh. (Cost Data 05/24)
Sl. No. Item Description Unit Tendered Qty. Unit Rate without GST (Rs) Applicable GST Amount @ 18% (Rs.) Unit Rate with GST (Rs) (5+6) Amount with GST (Rs) (4X7)
1 Earth work in excavation all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 SqM on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.( 2.6.1) CuM 3500
2 Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : exceeding 80 mm dia but not exceeding 300 mm dia (2.10.1.2) RM 550
3 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.(2.25) CuM 1000
4 Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.( 2.25(a)) CuM 14560
5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(2.27 ) CuM 400
6 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.(2.31) SqM 1500
7 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 30 cm girth upto and including 60 cm girth (2.33.1) Each 15
8 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 60 cm girth upto and including 120 cm girth (2.33.2) Each 5
9 Providing and laying in position cement concrete of 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.( 4.1.2) CuM 80
10 Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.(4.1.8 ) CuM 750
11 Providing and laying cement concrete in 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:.( 4.2.2) CuM 45
12 Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns ( 4.3.1) SqM 570
13 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification.( 4.12) Per bag of 50Kg cement used 1000
14 Providing and laying 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level :(5.1.2 ) CuM 1350
15 Reinforced cement concrete work 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :( 5.2.2) CuM 130
16 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).( 5.3) CuM 200
17 Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C) -(5.9 ) a.Foundations, footings, bases of columns, etc. for mass concrete, Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like( 5.9.1) SqM 3200
18 Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(5.9.2) SqM 500
19 Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C)Suspended floors, roofs, landings, balconies, Shelves (Cast in situ) and access platform(5.9.3 ) SqM 850
20 Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C)Lintels, beams, plinth beams, girders, bressumers and cantilevers( 5.9.5) SqM 250
21 Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C)Columns, Pillars, Piers, Abutments, Posts and Struts( 5.9.6) SqM 300
22 Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C)Weather shade, Chajjas, corbels etc., including edges( 5.9.19) SqM 50
23 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 Meter or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)( 5.11.1) SqM 300
24 Encasing rolled steel section in grillages with cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) including centering and shuttering but, excluding cost of expanded metal and hangers. (5.20) CuM 10
25 Steel reinforcement for R.C.C. work Thermo-Mechanically Treated bars of grade Fe-500D or more including straightening, cutting, bending, placing in position and binding all complete plinth/above level.( 5.22.6) Kg 82000
26 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. (5.30 ) Metre 102
27 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand)( 6.1.1) CuM 450
28 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand)(6.1.2 ) CuM 50
29 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand)( 6.4.1) CuM 27
30 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)(6.4.2) CuM 45
31 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in cement mortar 1:4 (1 cement : 4 coarse sand)( 6.12.2) SqM 20
32 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)( 6.13.2) SqM 100
33 Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in :Cement mortar 1:4 (1 cement : 4 coarse sand) (6.34.1) CuM 25
34 Brick work with modular extruded brunt fly ash clay sewer bricks (Conforming to IS: 4885 ) in cement mortar 1:4 (1 cement : 4 coarse sand) in foundation and plinth :Cement Mortar 1:4 ( 1 cement : 4 coarse sand) (6.36.1) CuM 15
35 Providing edge moulding to 18 mm thick Granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.( 8.3.2) Metre 125
36 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick :Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II, IS:12823 marked (9.7.5.4) SqM 15
37 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : Float glass panes 4 mm thick glass pane (weight not less than 10Kg/SqM). (9.7.7.1) SqM 3
38 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 Kg per SqM) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.Kiln seasoned selected planks of sheesham wood 30 mm thick (9.9.3.2) SqM 5
39 Providing and fixing ISI marked flush door shutters 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.( 9.20.2) SqM 5
40 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 Kg and door width upto 700 mm), with necessary accessories and screws etc. complete.( 9.83) Each 8
41 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm(9.97.2 ) Each 30
42 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150x10 mm( 9.97.4) Each 50
43 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm( 9.100.1) Each 25
44 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm( 9.100.2) Each 25
45 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper(9.101.2 ) Each 15
46 Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge. (9.119) Metre 70
47 Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing.30 mm thick plain PVC door shutters (9.120.1) SqM 30
48 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(CSI No. 10.1) Kg 7000
49 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.( 10.2) Kg 10000
50 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece ( 10.5.2) SqM 5
51 Supplying and fixing rolling shutters 80x1.25 mm M.S. laths with 1.25 mm thick top cover of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.(10.6.1 ) SqM 7
52 Providing and fixing ball bearing for rolling shutters. ( 10.7) Each 2
53 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.( 10.18) Each 14
54 Providing & fixing Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (10.29.1 ) SqM 12
55 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks:1:4 (1 cement : 4 coarse sand) (11.1.1) SqM 250
56 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (11.2 ) SqM 200
57 Providing and fixing glass strips 40 mm wide and 4 mm thick in joints of terrazo/ cement concrete floors. (11.13.1 ) Metre 110
58 Providing and fixing 10 mm thick acid and/or alkali resistant tiles in flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (11.21.1.1 ) SqM 60
59 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile (11.21.2.1 ) SqM 40
60 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 Kg/SqM including pointing the joints with white cement and matching pigment etc., complete. (11.37 ) SqM 25
61 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3Kg per SqM including pointing in white cement mixed with pigment of matching shade complete. (11.37A ) SqM 40
62 Providing and laying Vitrified tiles in floor Double charge vitrified tile polished finish of size 600 x 600 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 Kg/SqM including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (11.41A.1.1 ) SqM 175
63 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent (11.56.1 ) SqM 50
64 Providing reinforced by organic fibres and/or inorganic synthetic fibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required.(12.8) SqM 50
65 Providing and fixing ridges and hips in fibre cement reinforced by organic fibres and/or inorganic synthetic fibres roofing with suitable fixing accessories or self drilling fastener and EPDM washer etc. complete.:(12.12.1) Rmt 12
66 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75 mm deep chase (12.21.1) Metre 150
67 Providing and fixing 110 mm diameter on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. ( 12.41.2) Metre 100
68 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (12.45.1) SqM 100
69 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. (12.52.3) SqM 150
70 12 mm cement plaster (IN COARSE SAND) of mix 1:4 (1 cement: 4 coarse sand) ( 13.4.1) SqM 2500
71 12 mm cement plaster (IN COARSE SAND) of mix 1:6 (1 cement: 6 coarse sand) (13.4.2 ) SqM 500
72 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand) ( 13.5.1) SqM 100
73 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) (13.5.2 ) SqM 50
74 12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. ( 13.9.1) SqM 400
75 Neat cement punning. (13.18 ) SqM 2000
76 White washing with lime to give an even shade : New work (three or more coats) ( 13.37.1) SqM 200
77 Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) (13.44.1) SqM 1400
78 Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 SqM over and including priming coat of exterior primer applied @ 0.90 litre/10 SqM)(13.46.1 ) SqM 300
79 Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with black anticorrosive bitumastic paint of approved brand and manufacture, over and including a priming of ready mixed zinc chromate yellow primer on new work:100 mm diameter pipes (13.55.1) Metre 75
80 Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work.100 mm diameter pipes (13.56.1) Metre 50
81 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture(13.62.1 ) SqM 1200
82 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (13.80 ) SqM 1250
83 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound )(Two coat) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (13.83.2 ) SqM 600
84 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete(13.88 ) SqM 750
85 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (15.3) CuM 20
86 Demolishing brick work manually/ by mechanical means in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (15.7.4) CuM 50
87 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 Meters lead :Of area 3 sq. Meters and below(15.12.1) Each 12
88 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 Meters lead.( 15.25) SqM 20
89 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 15.56 ) SqM 180
90 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. (16.1) SqM 1800
91 Supply of welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (16.15.2 ) Kg 1750
92 Welded steel wire fabric fencing with posts of specified material and of standard design placed and embedded in cement concrete blocks 45x45x 60 cm of mix 1:5:10 (1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size), every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and struts embedded in cement concrete blocks 70x45x50 cm of the same mix, provided with welded steel wire fabric fixed between the posts fitted and fixed with G.I. staples on wooden plugs or tied to 6 mm bar nibs with G.I. binding wire (cost of posts, welded steel wire fabric, painting, earth work in excavation and concrete to be paid for separately). ( 16.20) SqM 225
93 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (16.45 ) Per cm depth per cm width per Meter length 7000
94 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (16.53) Meter 550
95 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).(16.69) CuM 5
96 Providing and fixing G.I. wire of dia 4 mm chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (16.70.1 ) SqM 950
97 Providing and laying C.C. pavement of mix M-20 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 Kg/CuM. Excess/less cement used as per design mix is payable/ recoverable separately). (CSI16.75-16.76) CuM 250
98 Construction of granular sub-base by providing with material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (16.78.2 ) CuM 550
99 Providing and laying 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (16.91.2 ) SqM 150
100 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests( 17.1.1) Each 3
101 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid ( 17.3.1) Each 2
102 Providing and fixing White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: ( 17.7.3) Each 3
103 Providing and fixing 610x460 mm bowl depth 200 mm Stainless Steel Kitchen sink without drain board ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : ( 17.10.2.2) Each 1
104 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. ( 17.23) Each 1
105 Providing and fixing 32 mm dia Flexible pipe P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. ( 17.28.2.1) Each 3
106 Providing and fixing 100 mm sand cast Iron grating for gully trap. ( 17.29 ) Each 8
107 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (17.31 ) Each 5
108 Providing and fixing PTMT 600 mm long with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour ( 17.73.2) Each 2
109 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 (17.60.1.3) Each 7
110 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes (18.8.1) metre 35
111 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes (18.8.2) metre 20
112 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore ( 18.10.2 ) Metre 20
113 Providing and fixing 20 mm dia nominal bore G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : ( 18.11.2 ) Metre 50
114 Providing and fixing 25 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work ( 18.12.3) Metre 20
115 Providing and fixing 32 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work ( 18.12.4 ) Metre 50
116 Providing and fixing 40 mm dia nominal bore G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work ( 18.12.5) Metre 25
117 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore ( 18.13.1) Each 10
118 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (18.15.1) Each 5
119 Providing and fixing 15 mm dia brass stop cock of approved quality (18.16.1) Each 5
120 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore (18.17.1) Each 10
121 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm nominal bore ( 18.17.1A) Each 5
122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. ( 18.17.2) Each 3
123 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore (18.17.3 ) Each 2
124 Providing and fixing ball valve (brass) of Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore (18.18.1) Each 3
125 Providing and fixing 150 mm diameter C.P. brass shower rose with 15 or 20 mm inlet : ( 18.22.2) Each 2
126 Boring with 100 mm diameter casing pipe for hand pump / tubewell, in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested :Up to 6 Meters depth (18.42.1) Metre 12
127 Beyond 6 m and up to 12 m depth (18.42.2) Metre 12
128 Beyond 12 m and up to 18 m depth (18.42.3) Metre 12
129 Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality. (18.43) Metre 10
130 Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well. (18.44) Metre 26
131 Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories. (18.45) Each 2
132 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (18.48 ) Per litre 8000
133 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS:8931 : ( 18.49.1) Each 10
134 Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (18.50.1 ) Each 3
135 Providing and fixing15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. (18.51.1 ) Each 5
136 Providing and fixing 15 mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (18.52.1 ) Each 4
137 Providing and fixing 15mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ( 18.53.1) Each 6
138 Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. ( 18.53A) Each 10
139 Providing and fixing 15 mm nominal bore with 30cm length unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. (18.74.1 ) Each 5
140 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (19.27.1) No 20
141 Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (19.29.1) Each 10
142 Making soak pit 2.5 m diameter 3.0 Meter deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (19.32.1 ) Each 3
143 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 450 mm dia RCC pipes. (19.35.1) Metre 12
144 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete. 600 mm dia RCC pipes. (19.35.2) Metre 12
145 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles( 20.3.1) Metre 50
146 400 mm dia piles( 20.3.2) Metre 50
147 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid)( 20.4)a. 300 mm dia piles( 20.4.1) Each 80
148 400 mm dia piles(20.4.2 ) Each 80
149 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.(20.6 )a.Single pile upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)(20.6.1.1 ) Per test 1
150 Single pile upto 50 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity)( 20.6.1.2) Per test 1
151 Group of two or more piles upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)( 20.6.3.1) Per test 1
152 Group of two or more piles upto 50 tonne Safe capacity Routine test (Test Load 1.5 times the Safe capacity)(20.6.3.2 ) Per test 1
153 Cyclic vertical load testing of pile in accordance with IS Code of practice IS:2911 (part IV) by Kentledge method including preparation of pile head etc for.(20.7 )a.Single pile Upto 50 tonne Safe capacity pile(20.7.1.1 ) Per test 1
154 Group of two or more piles Upto 400 tonne Safe capacity of group(20.7.2.1) Per test 1
155 Lateral load testing of single pile in accordance with IS Code of practice IS : 2911 (Part IV) for determining safe allowable lateral load on pile :(20.8 )a.Upto 50 tonne capacity pile(20.8.1 ) Per test 1
156 Above 50 tonne and upto 100 tonne capacity pile( 20.8.2) Per test 1
157 Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge.(20.9) per test 2
158 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)( 21.1.1.2) Kg 510
159 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever requiredincluding cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of all fittings, EPDM rubber / neoprene gasket required Powder coated aluminium (minimum thickness of powder coating 50 micron).( 21.1.2.2) Kg 200
160 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side (21.2.1 ) SqM 25
161 Providing and fixing float glass panes of 5 mm thickness (weight not less than 12.50 Kg/SqM) glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):( 21.3.2) SqM 80
162 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. With stainless steel cover plate minimum 1.25 mm thickness complete as per the direction of Engineer-in-charge.(21.4.1 ) Each 10
163 Providing and Placing in position Serrated with central bulb (225 mm wide, 8-11 mm thick) suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : (22.4.1) Metre 20
164 Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge.(22.22A) SqM 175
165 Providing and applying of swellable type water stop tape, 19mm x 25mm thick in linear meter (expansive nature) for construction joints treatment of RCC structure such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc.. After cleaning the surface, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint @3.78 litre per 240 running meter. Over the primed surface swellable type water stop tape shall be placed. The work shall be carried out all complete as per specification and the direction of the Engineer-In-Charge. The product performance shall carry guarantee for 10 years against any leakage.(22.26) Metre 10
166 Boring/drilling bore well in all types of soil of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 Meter depth below ground level.300 mm dia (23.1.1.1 ) Metre 90
167 Boring/drilling bore well in all types of soil of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 Meter & upto 150 Meter depth below ground level. (23.2.1 )a.300 mm dia (23.2.1.1 ) Metre 30
168 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of 100 mm nominal size dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (23.3.1) Metre 30
169 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.150 mm nominal size dia(23.3.2) Metre 90
170 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well 100 mm nominal size dia screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (23.4.1) Metre 15
171 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (150 mm nominal size dia) (23.4.2) meter 30
172 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.( 23.5) CuM 3
173 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.( 23.6) CuM 3
174 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.( 23.7 ) CuM 2
175 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (23.8 ) CuM 20
176 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. ( 23.12 ) Hour 35
177 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp (23.14.2) Each 1
178 Providing and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime, cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1mm thick of required sizes as recommended by manufacturer's and fixed to floor and RCC soffit in plumb to each other with steel screw/fasteners. The panel shall be fixed vertically with tongue & groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer based jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge. Non load bearing panels 75 mm thick of required size (minimum 5mm thick fibre cement board Type A, Category III as per IS: 14862:2000 on both faces) (Cost of all the material is included except "tracks/C channel" which will be paid separately). (26.50.2A) SqM 90
179 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C (DSR E&M 2022 1.10.3)( 27.01) Point 125
180 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4)(27.02 ) Each 25
181 Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including junction box, cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 2022 1.21.1)( 27.03) Metre 300
182 Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including junction box,cutting the wall and making good the same in case of recessed conduit as required.(DSR E&M 2022 1.21.2)( 27.04) Metre 260
183 Wiring for circuit/ submain wiring with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR E&M 2022 1.14.2)( 27.05) Metre 250
184 Wiring for circuit/ submain wiring with 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR E&M 2022 1.14.3)( 27.06) Metre 140
185 Wiring for circuit/ submain wiring with2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 2022 1.14.4)( 27.07) Metre 90
186 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6)(27.08 ) Set 2
187 Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.(DSR E&M 2022 5.12)( 27.09) Metre 70
188 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1)( 27.10 ) Each 30
189 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2)( 27.11) Each 5
190 Supplying and fixing 40 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.12.1)( 27.12) Each 10
191 Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR E&M 2022 2.4.1)( 27.13) Each 6
192 Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1) ( 27.14) Each 4
193 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12)( 27.15) Metre 24
194 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1)( 27.16) Each 10
195 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)(DSR E&M 2022 1.27.2)( 27.17) Each 10
196 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3)( 27.18) Each 5
197 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4)( 27.19) Each 5
198 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5)( 27.20) Each 5
199 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6)( 27.21) Each 5
200 Supplying and drawing following 3 x 2.5 sq. mm sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(DSR E&M 2022 1.17.12) (27.22 ) Metre 150
201 Providing and displaying of Areca Palm having ht. 90 cm to 1.20 m with 4 to 5 suckers, well developed, fresh and healthy with lush green foliage in 25 cm size of Earthen pot/Plastic pot & as per direction of the officer-in-charge.(DSR Horticulture 2020 3.18) (28.14 ) Each 10
202 Providing Circular Cement Concrete pots of specified size, cast with cement concrete of nominal mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size), reinforced with 7 Nos ( 3 nos horizontal & 4 nos vertical “ U “ shape) M.S. wires of 3.5 mm dia as per design, including required form work, finishing with cement punning on exposed surface, curing for specified period and stacking in required rows & height, all complete as per direction of Officer-in-charge. Top inside dia 30 cm, outer bottom dia 20 cm, total height 30 cm & with wall thickness of 25.4 mm (DSR Horticulture 2020 2.30.1) (28.18 ) Each 50
203 Providing & laying Selection no. 1 doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same maintenance for 30 days or more till the grass establish properly,as per direction of officer in charge. (DSR Horticulture 2020 2.34) ( 28.20) Per SqM 100
204 Providing and Displaying Standard Rose (H.T. variety) 3 to 4 healthy branch 90 cm and above ht. well developed with one and above flowers in 25 cm Earthen Pot, as per direction of the officer-in-charge.(DSR Horticulture 2020 4.93) ( 28.52) Each 15
205 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.(DSR Horticulture 2020 7.77) ( 28.61) Each 20
206 Providing and stacking of Bougainvillea (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Variegated, Glabra Formosa, Peruviana Odissi, Paratha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. (DSR Horticulture 2020 9.4) ( 28.65) Each 10
207 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (29.01) Cum 40
208 Arranging and spreading 75 mm thick broken grit 20 mm (Granite stone) uniform for turfing over 100mm thick base course of C.C. In 1:4:8 (1cement:4coarse sand: 8, 40mm stone ballast) top finish by brooming of cement mortar 1:4(1cement: 4 Coarse sand) including supply of all materials, labour and tools and plants etc. required for proper completion. (29.02) Sqm 6000
209 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (29.03) Cum 90
210 Supply and filling brick bat in soak pit including all labour,material and T&P etc complete. (for 01 soak pit)(29.05 ) CuM 25
211 Supplying & fixing 24 gauge annodized aluminium sheet of approved quality including cutting, wastage and fixing the same over the wooden door shutters with nails with all material, labour and T&P.( 29.06) SqM 4
212 Supply of 28 mm. dia M.S. Anchor bolts (conforming to IS 266) 900 mm. long with base plate (75x75x6mm) welded with anchor bolts including its threading upto a length of 10cm. and also supply of a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & T&P for proper completion of work. ( 29.13) No 1300
213 Fixing and grouting 28 mm and above dia bolts in proper alignment level and setout with help of a template complete including supply of all labour & T&P etc. required for proper completion of the work.(labour rates only) . ( 29.14) No 1300
214 Supply of 25 mm dia.M.S. Anchor bolts (conforming to IS-226) 500 mm long with base plate(50x50x6 mm)welded with anchor bolts,including its threading upto a length of 10cm. and galvanizing upto 15cm from top, also supply of a pair of galvanized standard nuts with threading including supply of 5mm thick washer and cost of labour material and T&P etc. required for proper completion of the work. (29.15 ) No 1500
215 Fixing and grouting 25 mm and below dia M.S. Anchor bolt in proper alignment level and setout with the help of a template including supply of all labour T&P etc. reqd. for proper completion of the work. (labour rates only) . (29.16 ) No 1500
216 S/F in position 90 lbs M.S. Rail for transformer plinth including cost of all labour, material and T&P etc. required for proper completion of the work. (29.19 ) Rmt 20
217 Grouting of vertical or inclined post of pale/chain/security fencing in true level, alignment and in plumb or inclination as required, including cost of all labour, materials and T&P required for proper completion of work. ( Post and concrete for grouting shall be measured separately) ( 29.21) No 175
218 Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only). ( 29.22) Rmt 1400
219 Fixing of template in position level and alignment for grouting of Anchor bolt in main gantry (labour rate only). (29.23 ) No 70
220 Fixing of template in position level and alignment for grouting of Anchor bolt in auxiliary structure. (labour rate only). (29.24 ) No 260
221 Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only). ( 29.25) No 1000
222 Providing (12x15) mm section groove in plaster including all material, labour and T&P etc. required for proper completion of the work. (29.33 ) Rmt 1160
223 Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. ( 29.34) Rmt 6600
224 2.5 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC ( 29.35) SqM 60
225 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC (29.36 ) SqM 600
226 Painting letters & number over cable trench cover or other places with the help of stencils including painting of base of 150 mm. dia of one coat of primer and two coats of superior quality synthetic enamel paint size of letter to be 60 mm. x 10 mm. including cost of all materials labour and T&P etc. required for proper completion of the work including placing of Trench covers in required position. (CSI No. 29.37) No. 1640
227 Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls & floors, around the external periMeter of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/SqM, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / SqM, (iii) Top surface of Plinth filling @ 5 Ltrs / SqM, ( iv) Junction of walls & floors @ 7.5 Ltrs / SqM, (v) Soil along external periMeter of building @ 7.5 Ltrs / SqM (vi) under apron of the building @ 5 Ltrs. /SqM. The rates includes cost of all materials, labour, equipments, T&P complete. ( 29.41) SqM 200
228 Providing and fixing MS reducer 150x100mm for making tubewell assembly , including cost of all labour, materials and T&P required for assembly making and proper completion of work. ( 29.42a) No. 1
229 Supply and fixing of 110 mm dia PVC. bail plug of heavy quality including all labour material & T&P. (29.46a) Each 1
230 Supply and fixing support clamps for 40 mm column pipes made out of MS flats, pairs of bolt-nuts etc complete with all material, labour, T&P. (29.48b ) No. 2
231 Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. ( 29.51) Job 1
232 Supply and installation of 5H.P. Kirloskar or equivalent make single stage, horizontal, self priming,three phase dewatering pumpset of specification Head 14/16 M, Discharge 13.6/10 LPS, solid handle size 15.5 mm, suction 80 mm, delivery 80 mm, RPM 1500 including cost of 80 mm dia G.I. pipe for suction (3M) and delivery (4.5 M). ( 29.52) No 2
233 Supply & installation of electrical control panel of L&T / Havells or equivalent make for 1.5/2.00 H.P single phase submersible pumpset / pumpset containing contractor relay condenser. ( 29.54b ) No 1
234 Supply & installation of electrical control panel of L&T / Havells or equivalent make for or 5 H.P pump set three phase submersible pump / pumpset containing contractor relay condenser. ( 29.54d) No 1
235 Supply & Installation of submersible pump 2 HP outlet 40mm dia. or more, Head 89/45, Discharge 2000/6000 LPH of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (29.55c ) No 1
236 Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (29.56 ) RM 90
237 Providing and fixing of 200 mm dia PVC pipe of 6 Kg/sqcm with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. ( 29.90) RM 10
238 Providing and fixing of 150 mm dia PVC pipe of 6 Kg/sqcm with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. ( 29.91) RM 70
239 Providing and fixing soap dish chromium plated with brackets fixed to wooden cleats with brass screws including supply of all materials,labour and T&P etc.required for proper completion of the work. ( 29.108 ) No 2
240 Providing and laying 110 mm SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. ( 29.109c) RM 40
241 Providing and fixing 110 mm SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. ( 29.110c) No. 15
242 Providing and fixing 110 mm SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etc required for proper completion of the work. ( 29.112c) No. 15
243 S/F full way 63/65 mm dia Fire hydrant Gun Metal Gate Valve heavy quality including supply of all labour , material andT & P for proper completion of work. ( 29.117) No. 2
244 P/F Male & Female coupling 63/65 mm dia. Gun metal BSI marked confirming to IS:903 heavy quality including supply of all labour , material and T & P for proper completion of work. ( 29.118) No. 2
245 P/F Short Branch pipe Gun Metal BSI marked heavy quality including supply of all labour , material and T & P for proper completion of work. ( 29.119) No. 2
246 P/F 63 mm dia RLL Hose Pipe heavy quality having length 15.0 m including supply of all labour , material andT & P for proper completion of work. ( 29.120) RM 30
247 P/F MS Hose Box Single Door with stand for 15 mt RRL Hose heavy quality including supply of all labour , material andT & P for proper completion of work. ( 29.121) No. 2
248 Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C. ( 29.123 ) SqM 20000
249 Marking of building and foundation in new sub-station (132/220 KV) in UPPCL land as per approved layout drawing with help of Theodolite/ total station instrument and closing of Travers for main Gantry etc including cost of all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.(29.124 ) Job 1
250 Making borehole in all type of soil by any method required as per site conditions in accordance with IS specification No 1982-1979 and 1498-1970 and conducting standard penetration test in accordance with IS specification No 2131 – 1981 at every 1.5 M approx . or as per strata during making borehole and also collecting undisturbed and disturbed soil samples at a depth of approx. 1.5 M depth or change of strata of soil as per site requirements in each borehole in accordance with IS specification 1892-1978. (Depth of water table as detemine from borehole or from nearest waterwell ) Each Boreholes to be bored upto 15.00 depth.( 29.125) RM 40
251 Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2920 (Part 1)-1983 (29.126 )
i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2920 (Part ix) ISS 2920-(Part xii) ISS 2920-(Part xiii) on silty/sandy soil .
Consolidation Test as per ISS-2920( Part xv )on clay soil
ii) Sieve analysis test as per ISS 2920 (Part iv)
iii) Atterberg’s limit tests as per ISS –2920 (Part v)
iv) Particle size analysis test as per ISS 2920 (Part iv)
v) Natural moisture content test as per ISS 2920 (Part vi)
vi) Wet density test and dry density test as per ISS 2920 (Part vi)
vii) Specific gravity test as per ISS 2920 (Part iii) section 2
Disturbed soil samples will be prepared in accordance with ISS 2920 (Part I) 1983 and tested as follows
i) Sieve analysis test as per ISS – 2920 (part iv)
ii) Atterberg’s limit tests as per ISS- 2920(Part v) Job 1
252 Conducting plate load test near CONTROL ROOM BUILDING site at specifed depth as per IS 1980-1982 including supply of all material, labour and T&P equipment and recording of test result as per Codal requirement and submission of report.( 29.127) Job 1
253 Supply and Fixing of 3 blade wall fan of Havells platina 400 mm or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.(29.132 ) Each 5
254 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(29.133 ) Each 5
255 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.( 29.134) Each 25
256 Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect.( 29.135) Each 22
257 Hydraulic Excavator of 1 CuM bucket+(10% Contractor preofit) (Material item no 51 Ch. 1) Hour 40
258 Hire and running charges of crane 20 tonne capacity (Basic Rate with Item-0028) Day 3
259 Hire and running charges of hydraulic piling rig with power unit etc. including complete accessories and shifting at site (Basic Rate Item-0024) Day 1
260 Dewatering for all types of excavations including foundation trenches, pits,sumps, drain, etc. by pumping, bailing or any other approved method, keeping the excavation dry during construction, including cost of pumps, fuel, power, labour, maintenance, shifting of pumps, disposal of water and all incidental charges, complete as per direction of Engineering-in-charge (PWD.AZM-SOR/2025) (NSI) Hour/HP 1000
261 Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia PVC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing face. Complete as per drawing and Technical Specifications (NSI) Rmt 300
262 Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and Technical Specification.(NSI) Cum 12
263 Supply and installation of U shaped 600 mm X 600mm Precast RCC Trench (M30 Grade, Fe 500 Reinforcement) of approved thickness (Thickness 90 mm) with MS racks of 40x40xmm, 3 nos. i.e. One Full length and Two half-length @ 500mm c/c spacing as per specification, including its transportation to the site including lifting, placing and fixing etc. as per the direction or Engineer in Charge. The cost includes all labour, machinery, material for loading, unloading, fixing and T&P that may be required for proper completion of the work. (NSI) RM 150
264 Supply and installation of Precast Trench cover (M30 Grade, Fe 500 Reinforcement) (for U shaped 600mm X 600 mm precast trench) of thickness 145 mm including its transportation to the site including lifting, placing and fixing etc, as per the direction or Engineer in Charge. The cost includes all labour, machinery, material for loading, unloading, fixing and T&P that may be required for proper completion of the work. (NSI) RM 150
265 Supply and installation of U shaped 750 mm X 750mm Precast RCC Trench (M30 Grade, Fe 500 Reinforcement) of approved thickness (Thickness 100 mm) with MS racks of 40x40xmm, 3 nos. i.e. One Full length and Two half-length @ 500mm c/c spacing as per specification, including its transportation to the site including lifting, placing and fixing etc. as per the direction or Engineer in Charge. The cost includes all labour, machinery, material for loading, unloading, fixing and T&P that may be required for proper completion of the work. (NSI) RM 100
266 Supply and installation of Precast Trench cover (M30 Grade, Fe 500 Reinforcement) (for U shaped 750mm X 750 mm precast trench) of thickness 150 mm including its transportation to the site including lifting, placing and fixing etc, as per the direction or Engineer in Charge. The cost includes all labour, machinery, material for loading, unloading, fixing and T&P that may be required for proper completion of the work. (NSI) RM 100
267 Supply, fabrication, delivery, and on-site installation of a 20×10×8.5 ft (200 sq. ft.) premium heat-resistant 1-person accommodation porta cabin on a complete turnkey basis, featuring a heavy-duty ISMC steel under-grid base layout spaced at 1.5×1.5 ft intervals; 50mm wall and 60–80mm roof PUF panels (40 kg/m³ density) with a 1:10 drainage slope, finished externally with high-SRI weather-resistant heat-reflective paint; a completely waterproof and termite-proof 18mm Fiber Cement Board floor sub-base finished with a 2.0mm commercial PVC vinyl sheet; one (1) heavy-duty insulated PUF/metal main entry door with mortise lockset, hydraulic door closer, and weather seals, alongside two (2) double-glazed thermal windows (DGU) fitted with powder-coated/enamel-painted MS safety grills and mosquito mesh; an integrated 6×4 ft partitioned washroom with a waterproof WPC/FRP door, anti-skid flooring, and full sanitary ware; concealed fire-retardant (FRLS) copper wiring with a dedicated 1.5-ton split AC power point and multi-point LED lighting; and a built-in 4-ft wide water-resistant WPC/PVC wardrobe cabinet—including crane unloading, leveling on pre-prepared plinths, exterior plumbing/electrical hook-up, and final site commissioning as a single comprehensive job unit.(NSI) Job 2
268 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories. 120mm dia (DSR Electriacal item 15.15.3) (NSI) Rm 500
269 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories. 200mm dia (DSR Electriacal item 15.15.5) (NSI) Rm 400
Total (INR excluding GST)
Seal of Company
Full Signature ………………………………
Designation ………………………………
Tender Specification no. ESD-694
Name of Bidder:
Sl.No. DESCRIPTION Schedule Amount including GST (in Rs.)
1 Total Price for Supply of Equipments/Materials and Light Luminaires S-1
2 Total Price for Handling, Erection, Testing & Commissioning S-2
3 Net Price for Electrical works (1+2)
4 Net Price for Civil Works S-3
5 Total Bid Price (3+4)
Seal of Company Full Signature …………………………
Designation ……………
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TSESD694.pdf
Tender Documents • 5.85 MB
BOQESD694.xls
Additional Documents • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .