| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.6 LAccepted-AOC | L1 | Accepted-AOC Performance security Rs. 1,18,500.00 shall be submitted before 28 days from the acceptance of the contract as per Condition 19 of IAFW2249 otherwise necessary action will be taken against your firm | |
| 2 | L2₹33.7 L+₹7.9 L (30.4%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹41.3 L+₹15.4 L (59.7%)Rejected-Finance 0 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹48.7 L+₹22.9 L (88.5%)Rejected-Finance F 402 AMBIKA APARTMENT PLOT A 9 SECTOR 20 NERUL W NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹49.3 L+₹23.4 L (90.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | jkconstruction L11 | Advait Enterprises L4 | A S ENTERPRISES L3 | M/S MOHINI ENTERPRISES L8 | SHREE BHAGWATI ENTERPRISES L5 | M/S VIJAY SINGH L6 | Ambrish Builders L1 | TARKESHWAR DASS CONSTRUCTION COMPANY L9 | Madhu Electricals and Engineering Works L2 | Nitish Nandkumar Bothale L7 | ANNAPURNA ENTERPRISES L10 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out in solft loose soil incl old U/s cable cover of ant type, taking out/laying/cleaning/repairing of CI/GI pipe line, cable etc., complete all as specified and directed. | 281 | Cum | 420 ₹1,18,020 | 360 ₹1,01,160 | 110 ₹30,910 | 450 ₹1,26,450 | 390 ₹1,09,590 | 387 ₹1,08,747 | 100 ₹28,100 | 500 ₹1,40,500 | 77 ₹21,637 Lowest | 389 ₹1,09,309 | 180 ₹50,580 |
| 2.00 | Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil, complete all as specified and directed. | 190.48 | Cum | 242 ₹46,096.16 | 200 ₹38,096 | 55 ₹10,476.4 | 400 ₹76,192 | 200 ₹38,096 | 193 ₹36,762.64 | 40 ₹7,619.2 | 410 ₹78,096.8 | 21 ₹4,000.08 Lowest | 220 ₹41,905.6 | 21 ₹4,000.08 Lowest |
| 3.00 | Removal of surplus spoil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level, complete all as specified and directed. | 30.52 | Cum | 180 ₹5,493.6 | 150 ₹4,578 | 55 ₹1,678.6 | 450 ₹13,734 | 140 ₹4,272.8 | 147 ₹4,486.44 | 60 ₹1,831.2 | 500 ₹15,260 | 26 ₹793.52 | 165 ₹5,035.8 | 21 ₹640.92 Lowest |
| 4.00 | Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2 (using 40mm graded crushed stone aggregate), complete all as specified and directed. | 20 | Cum | 2,600 ₹52,000 | 2,200 ₹44,000 | 1,100 ₹22,000 | 2,200 ₹44,000 | 2,250 ₹45,000 | 2,210 ₹44,200 | 2,000 ₹40,000 | 2,150 ₹43,000 | 707 ₹14,140 | 2,420 ₹48,400 | 221 ₹4,420 Lowest |
| 5.00Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends and removal from site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes :- (Earth work shall be measured and paid separately). | ||||||||||||||
| 5.01 | (a) 200 mm bore dia | 12 | RM | 110 ₹1,320 | 90 ₹1,080 | 30 ₹360 Lowest | 100 ₹1,200 | 90 ₹1,080 | 100 ₹1,200 | 50 ₹600 | 110 ₹1,320 | 45 ₹540 | 99 ₹1,188 | 55 ₹660 |
| 5.02 | (b) 150 mm bore dia | 155 | RM | 115 ₹17,825 | 95 ₹14,725 | 30 ₹4,650 Lowest | 100 ₹15,500 | 90 ₹13,950 | 100 ₹15,500 | 40 ₹6,200 | 105 ₹16,275 | 35 ₹5,425 | 103 ₹15,965 | 51 ₹7,905 |
| 5.03 | (c) 100 mm bore dia | 185 | RM | 140 ₹25,900 | 120 ₹22,200 | 25 ₹4,625 Lowest | 120 ₹22,200 | 120 ₹22,200 | 130 ₹24,050 | 30 ₹5,550 | 120 ₹22,200 | 29 ₹5,365 | 130 ₹24,050 | 45 ₹8,325 |
| 5.04 | (d) 80 mm bore dia | 6 | RM | 100 ₹600 | 85 ₹510 | 20 ₹120 Lowest | 105 ₹630 | 85 ₹510 | 110 ₹660 | 25 ₹150 | 110 ₹660 | 24 ₹144 | 94 ₹564 | 34 ₹204 |
| 6.00Laying only in trenches DI/CI pipe with spigot and socketed ends complete after cleaning properly thoroughly & removal of all blokage removing all site and deposited organics inside using bamboo or rod with brush complete all as specified and directed for the following sizes/bore of pipes :- | ||||||||||||||
Tender Value
₹48.4 L
EMD Value
₹97,000
Closing Date
22 Jan 2026, 6:00 pmClosed
GE (AF) Bamrauli
GE (AF) Bamrauli
SPECIAL REPAIR REPLACEMENT TO WATER SUPPLY VALVE SLUICE VALVE AND ALLIED WORK AND SPECIAL REPAIR REPLACEMENT OF CFL CONVENTIONAL LIGHT TO LED LIGHT AT AF STN BAMRAULI UNDER GE AF BAMRAULI
2026_MES_747146_1
9001/E8
Open Tender
Civil Works - Others
Works
180 days
GE (AF) Bamrauli
Please refer tender documents
7 documents required · 7 mandatory
₹500
GE (AF) Bamrauli
₹97,000
Yes
16 Apr 2026
3 Jan 2026
24 Jan 2026
3 Jan 2026
22 Jan 2026
17 Jan 2026
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out in solft loose soil incl old U/s cable cover of ant type, taking out/laying/cleaning/repairing of CI/GI pipe line, cable etc., complete all as specified and directed.
Returning, filling in & including spreading, levelling & well ramming in layers not exceeding 25 cm thick as in soft/loose soil, complete all as specified and directed.
Removal of surplus spoil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground level, complete all as specified and directed.
Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2 (using 40mm graded crushed stone aggregate), complete all as specified and directed.
Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends and removal from site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes :- (Earth work shall be measured and paid separately).
(a) 200 mm bore dia
(b) 150 mm bore dia
(c) 100 mm bore dia
(d) 80 mm bore dia
Laying only in trenches DI/CI pipe with spigot and socketed ends complete after cleaning properly thoroughly & removal of all blokage removing all site and deposited organics inside using bamboo or rod with brush complete all as specified and directed for the following sizes/bore of pipes :-
(a) 200 mm bore dia
(b) 150 mm bore dia
(c) 100 mm bore dia
(d) 80 mm bore dia
Supply & laying in trenches ductile iron (DI) pipe with spigot and socketed ends centrifugally cast iron class 'K-7' in any length laid in trenches, complete all as specified and directed for the following sizes/bore of pipes (DI fittings and jointing materials shall be measured and paid separately) :-
(a) 200 mm bore dia
(b) 150 mm bore dia
(c) 100 mm bore dia
Supply and laying DI pipe with flanged ends centrifugally cast iron class 'K-7' laid in trenches/wall/over head tank of any length of the following sizes, complete all as specified and directed (DI fittings and jointing materials shall be measured and paid separately) :-
(a) 150 mm bore dia
M&L for cutting of the CI/DI pipe in position for insert of new tee, branches such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc.with suitable size of clamp of size 40 x 6 mm with nuts, bolts and washer of the following sizes, complete all as specified and directed :-
(a) 200 mm bore dia
(b) 150 mm bore dia
(c) 100 mm bore dia
(d) 80 mm bore
M&L for rubber gasket joint suitable for DI pipe and fittings with size of nuts, washer & bolts etc., complete all as specified and directed for the following sizes :-
(a) 200 mm bore dia
(b) 150 mm bore dia
(c) 100 mm bore dia
(d) 80 mm bore
M&L for upto 150 mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, flanged spigot, caps and plugs, complete all as specified and directed.
M&L for upto 200 mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, flanged spigot, caps and plugs, complete all as specified and directed.
Taking up or down steel water tubing and connections including clearing the pipes free from scaling for reusing the same, complete all as directed for the following sizes :- Note :-Excavation will be measured and paid separately.
(a) 80 mm dia bore
(b) 50mm dia bore
(c) 40 mm dia bore
(d) 25 mm dia bore
(e) 20 mm dia bore
(f) 15 mm dia bore
Relaying/ refixing of old steel tubing and connection in new or old position including necessary cuttings, threading, and new fittings such as bends, elbows, socket nipples, tapers, and reducers etc., complete all as specified and directed.
(a) 80 mm dia bore
(b) 50mm dia bore
(c) 40 mm dia bore
(d) 25 mm dia bore
(e) 20 mm dia bore
(f) 15 mm dia bore
Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc., complete for the following sizes:- Make: Jindal/Prakash/Swastik. Note :- Excavation and earth work will be measured and paid separately.
(a) 80 mm dia bore
(b) 50mm dia bore
(c) 40 mm dia bore
(d) 25 mm dia bore
(e) 20 mm dia bore
(f) 15 mm dia bore
S&F for Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves. Make : Zoloto/Seico/Jindal/Upadhaya/Venus.
(a) 50 mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
(e) 15 mm bore
S&F for PVC bib tap 15 mm dia including taking out unserviceable tapes of 15 mm dia, complete all as specified and directed.
Supply, fixing, jointing and testing in repair of cast iron sluice valve class I (ISI MARKED) PN-1.6 type latest IS 14846-2000 flanged ends, drilled having stainless steel spindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve, complete all as specified and directed. (Make : Zoloto/Leader/Kirloskar) for following bore of CI pipe line :-
(a) 200 mm dia bore
(b) 150 mm dia bore
(a) 100 mm dia bore
(b) 80 mm dia bore
Dismantling old broken / damaged valve pit chamber and construct valve pit chamber of size 1050mm x 1050 mm x 1050 mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
All as per item No 19.00 above but size of valve chamber is 900 x 900 x 900 mm (internal) and all as specified and directed.
Supply, fixing, jointing and testing of cast iron non return valve double flanged ends as per IS-5312 (ISI Marked) complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable non return valve, complete all as specified and directed. (Make : Zoloto/Leader/Kirloskar) for following bore of CI pipe line :-
(a) 150 mm dia bore
(b) 100 mm dia bore
(a) 80 mm dia bore
Taking up or down PVC pipe and connection laid in trenches or floors or fixed to walls complete with all fittings etc., complete all as specified and directed of following sizes of pipe :- (Note -Earthwork shall be measured and paid separately under respective item of schedule 'A').
(a) 160 mm outer dia
(b) 90 mm outer dia
(c) 75 mm outer dia
Supply and laying in replacement unplasticised PVC heavy duty pipes with working pessure 6 Kg/SqCm and certified with ISI standards with all fitting such as elbow, tee, socket, reducer, MTA complete of suitable size laid in trenches complete with solvent of the following size with all fitting, complete all as specified and directed :- Make:- Supreme/Premier/Finolex.
(a) 160 mm outer dia
(b) 90 mm outer dia
(c) 75 mm outer dia
S&F 32 mm dia hydrant opener made out of GI pipe 32 mm dia medium grade including welding handle rod of 10 mm dia and 450 mm long including taking down old unserviceable opener complete all as specified and directed.
S&F in replacement of sprinkler with single discharge nozzle 9 mm bore and all fitting including taking down unserviceable sprinkler, complete all as directed by Engineer-in-Charge. Make : Premier / ZM-22 or equivalent.
Supply and fixing in replacement hydraunt (quick coupling valve) made out of aluminium alloy with plastic powder coating and having positive action, self closing spring loaded brass valve arrangement the out let having hinged rubber lid, inlet size 40mm with 32mm out let including taking down unserviceable hydraunt with complete fitting, complete all as specified and directed. Make : Drip N Drip/Premier or equivalent.
Taking down carefully aluminium batten point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fittings and fixture as directed and deposit in MES store yard. (ii) Quoted rate also deem to be included cost of cutting chases for taking out concealed conduit and nitch for terminal box. (iii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through new PVC concealed conduit mediem grade, ISI marked and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular inner and outer plate for housing switches , socket outlet and fan regulators etc, complete all as specified and as directed for the followings:-
(a) One light/fan/bellpoint controlled by one switch single pole one way, complete all as specified and directed.
(b) All as per item No 28.01 here-in-before but one 3 pin 6 amp switch socket out let independent, complete all as specified and directed.
(c) All as per item No 28.01 here inbefore but one 3 pin 6 amps socket outlet on the same board with other switch, complete all as specified and directed.
All as per item No 28.02 here-in-before but using 02 Nos 4.0 sq mm size for main cable and 01 No 4 sq mm size as earth conductor for one 16 Amp switch socket outlet on independent board, complete all as specified and directed.
Supply and fixing of switch modular flush 6A single pole one way ISI marked, complete all as specified and directed.
Supply and fixing of modular sockets 6 Amp 2 in 1 2/3 pin combined, complete all as specified and directed.
Supply and fixing ofswitch modular flush type 15/16 Amp single pole one way 240 volt one module ISI marked, complete all as specified and directed.
Supply and fixing of modular sockets 16 Amp 2 in 1 3/5 pin combined, complete all as specified and directed.
Supply and fixing of ceiling rose surface bakelite 60x25mm three terminal, complete all as specified and directed.
Supply and fixing of electronic step type fan regulator 240 volt 50 Htz 120 watt (switch/sockets type in shape) modular type, complete all as specified and directed.
S&F of LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, system lumen efficiency >90 lumen/watt, 6500k and including connecting from ceiling rose to fitting incl taking down old unsv light. complete all as specified and directed.
S&F of LED batten luminaire surface mounted,2 feet system wattage of 10 Watts, system lumen efficiency >90 lumen/watt, 3200k and including connecting from ceiling rose to fitting incl taking down old unsv light, complete all as specified and directed.
Supply and fixing in replcement flood light 45 watt 240 volt 50 Htz 4500/6500K 120 lumen/watt IP-65, complete all as specified and directed.
Supply and fixing of MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link, complete all as specified and directed by Engineer -in- Charge.
Supply and fixing of MCB SPN 40 to 63 Amp Amps 240 volts 10 KA 50 HZ 'C' curve, complete all as specified and directed by Engineer in Charge.
Supply and fixing of MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve, complete all as specified and directed by Engineer in Charge.
Supply and fixing of MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in Charge.
S&F of ceiling mounted, round LED down light fitting 15 watts with die cast aluminium housing including connecting up with PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed, complete all as specified and directed.
Supply and fixing of LED 2 X 2 ft recess mounted fitting 36 Watts not less than 3200lm of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangements fixed, complete all as specified and directed.
Supply & fixing of 45W LED building security light fitting including provision of 25/32mm bore GI light grade pipe1.2 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole/ wall, complete all as specified and directed.
S&F of 10 watts bulkhead fitting , IP65 Protection, System , including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed, complete all as specified and directed.
Supply & fixing of 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz, complete all as specified and directed.
Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material.
stage.html
html • 0.08 MB
technical_836663.pdf
techsummary_836663.pdf
finance_836663.pdf
BOQ Comparative Chart
xlsx
finsummary_836663.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_836663.xls
BOQ • 3.90 MB
Tender.pdf
Tender Documents • 1.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .