| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹22.8 L+₹1.6 L (7.55%)Rejected-Finance 88 197 B CHAMAN GANJ KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹22.9 L+₹1.7 L (8.00%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹23.0 L+₹1.9 L (8.77%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹23.9 L+₹2.8 L (13.0%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
9 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) UDHAMPUR
GE AF STN UDHAMPUR
PROVISION OF CERTAIN MINOR AND REVENUE WORKS AT AIR FORCE STATION UDHAMPUR (GE/AFU-50/2023-24)
2023_MES_621688_1
GE/AFU-50/2023-24
Open Tender
Civil Works
Works
120 days
GE AF STN UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) UDHAMPUR
₹52,000
Yes
15 Jan 2024
5 Oct 2023
11 Nov 2023
5 Oct 2023
9 Nov 2023
26 Oct 2023
5 Oct 2023 - 12 Oct 2023
Amount
B/R Portion
Dismantling boarding, any description, fixed in any position with screws complete all as specified and directed.
Providing & fixing false ceiling with semi perforated 12mm thick micro tegular edged at all heights with GRG (glass fibre reinforced gypsum) false ceiling tiles of size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRCO 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part-4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dipped galvanized iron section of .33mm thick(galvanizied @ 120 grams per sqm including both sides) comprising of maint runners of size 15 x 32mm of length 3000mm, cross-T of size 15 x 32 mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling suspended from the roof truss using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm legth and L- shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x.40mm of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs at 450 mm center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engr-in-charge complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth w/o using extra cement complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth w/o using extra cement complete all as specified and directed
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed.
M&L for Preparation of newly plastered wall surfaces and applying two coats of white wash on wall complete, all as specified and as directed by Engr-in-Charge.
M&L for preparation of newely plaster surface of wall and applying two coats of cement base paint over a coat of primer in camauflage pattern complete all as specified and as directed.
M&L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified. complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete, all as specified and as directed by Engr-in-Charge.
Demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for cement concrete type B-1, 1:2:4 25 mm thick (20mm graded aggregate) complete, all as specified and as directed by Engr-in-Charge.
M&L for Cement concrete work in pavement/ hard-standing of flexural strength 40 kg /per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete, all as specified and as directed by Engr-in-Charge.
M&L for cement concrete type C-2, 1:3:6 (40mm graded aggregate) complete, all as specified and as directed by Engr-in-Charge.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over a screed bed 15mm thk in CM 1:6 complete all as specified and directed.
M&L for Powder Coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
M&L for Powder Coated door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified. complete all as specified and directed.
M&L for Powder Coated window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
S&L for aluminium square deco grill for window and door of 4 mm round rod, opening gap size should be 3 x 3 inches and finish of grill should be powder coated complete all as specified and as directed.
S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
M&L for Sheet glass, ordinary quality and glazing with oil putty in square any size secured with powder coated aluminium snap beading in each pane complete all as specified and directed.
M&L for Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified. complete all as specified.
M&L for reinforced cement concrete 1:2:4 (12.5 mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified
S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
M&L for new or previously untreated surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified. complete all as specified and directed.
Removing excavated material (soils) n.exc. 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
S&F Flexible bendable ceiling curtain track, curved ceiling track for curtains, including necessary hooks for hanging curtains minimum 08 Nos / RM and room divider ceiling track system including installation from ceiling complete all as specified and directed.
S&F rolled mild steel (Fe 410 -W (Gde- E- 250) quality-A) in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated
M&L excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.
M&L for cement concrete (1:3:6) in foundation, filling and mass concrete type C-1 using 20mm graded stone aggregate complete all as specified and directed.
M&L for cutting holes (exc 250 square cm but N exc. 500 square cm) into or through cement concrete slabs, chajjas,(upto 20 cm depth) etc. reinforced or otherwise complete all as specified and directed. (MW-04)
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills, sunshades, shelves, lintels, etc.;and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth all as specified and all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
M&L 150 mm thick type C2 for Concrete bed 1:3:6 drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed.
Cutting into existing manholes for connecting new drains 150 mm bore, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed.
Cutting holes in brick work built in cement mortar exc half brick but n exc one brick for inserting pipes/ holdfast etc. and m,aking good dismantling prtion in cement mortar 1:3 or cenet concrete 1:2:4 type B1 all as specified and all as directed.
M&L Providing cement concrete 1:2:4 type B2 40mm Graded stone aggregate as in foundation filling complete all as specified and as directed.
S & F stop cock 15 mm bore cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwdd both ends for iron pipe or for unions and fixed complete all as specified and directed.
M & L for PVC (SWR) 110 mm bore (dia) soil, waste and ventilating pipe, Singe Socketed, in any length with Rubber Ring Joints fixed to Walls,complete all as specified and directed.
M&L for GI Tubes, ' medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors (15 mm dia )complete all as specified and directed.
M&L 20 mm thick granite of any colour work (table rubbed and polished) in steps,jambs ,pillars,window-cills,cooking plateforms and like in cement mortar(1:4) including pointing in white cement(1:2) using marble dust with admixture of pigment to match withshade of graniten including screed bed bedding layer of 15 mm thick in CM 1:6 complete all as spfd. and polishing complete all as directed.
M&L Glazed ceramic colour tiles as in vertical surfaces 350x250x7mm / 450x350x7mm thick jointed in neat cement slurry and pointed in white or coloured cement to match the surface incl. 10 mm thick plaster in CM 1:3 complete all as specified colour and design approved by Engr-in-Charge
M&L for RCC (nominal mix) Type B1 1:2:4 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs landings, balconies, canopies and in shelves etc complete all as specified and as directed by Engr-in-Charge.
M&L for form work to soffits of flat, fair finished surfaces of concrete of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) complete all as specifed and directed.
S&F Bib tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed in 15 mm bore pipe complete all as specifed and directed.
S&F Sinks made of stainless steel 1mm thick overall size `495x420mm bowl size 410x330x160mm for kitchen or laboratory with plugs, washers and wastes, inlcuding bedding in cement mortar connecting union to pipe, PVC flexible pipe of 40mm dia with threaded adopter confirming to class III from sink to nahni trap of approved brand including cost of materials, adhesive solution, inlcuding coupling complete all as specified and as directed.
S & F of PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4. complete all as specified and directed.
Taking down Chowkhats or frames (without taking off shutter from frame) exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and as directed.
Demolition of brick work, stone/boulder masonry built in cement mortarcomplete all as specified and as directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided (concrete is reinforced and cut as to facilitate reinforcement for demolition) for complete all as specified and as directed.
M&L for brick work with sub class B bricks straight or curved on plan exc 6m radius in CM 1:6 complete all as specified and as directed.
M&L for preparation of newly plastered wall surface and applying two coat of distemper oil emulsion over a coat of primer complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, aliuminium rail all as directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L for Sheet glass of thickness 4.80mm, ordinary quality and glazing and fixing in aluminium shutter complete all as specified and directed.
M&L for Sheet glass of thickness 4.80mm, ordinary quality, glazing sheet glass is ground or obscured or frosted, on one side and fixing in aluminium shutter complete all as specified and directed.
S&F for Neoprene/ EPDM rubber gasket complete all as specified and directed.
E/M PORTION M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point / Bell switch controlled by one switch
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
M&L for point wiring complete with PVC insulated and unsheathed cable 4.0 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 4.0 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
S&F switch piano, flush type, 5 amps single pole, one way
S&F Socket outlet, flush type, 5 amps single pole, one way
S&F switch socket combination , flush type, 16 amps single pole, one way
Supply and fixing of Lamp Holder ,PVC /Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
S&Fceiling rose 3 phase /PVC/polycarbonate,isolated body complete all as specified and as directed..
M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid SurfacePVC conduit ISI Marked , heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 6.00 sqmm cable and one RM of6.00sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Supply and fixing of LED lights fitting Four feet 1 x 20 Watt LED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.Make :Bajaj/wipro/Havells /Orient/philips
Supply and fix Electric Water heater storage type steel body wiith steel inner tank and heating element up to 2 KW pressure 8 bars ,capacity 25 Ltitre, BEE 5 Star rated complete with all accessories such as safety valve thermostate NRV ,Connection piece etc complete all as specified and as directed.
Supply and laying GI water tubing of 20mm bore, medium grade galvanized with all fittings (such as tee, elbow, socket, union, short pieces) and application of bituminous paint on concelaed portion of tubing , fixed to wall or ceiling or laid in floor, complete all as specified and directed. Note : Rate quoted includes road cutting / wall cutting / floor cutting and making good damaged portion matching with existing surface with all existing finishess
Supply and fixing of bib tabs 15mm cast copper alloy with crutch on butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed
Supply and fixing gun metal gate valve, brass ball valve gunmetal non-returning valve in (cost of male socket included) of 20mm dia complete all as specified and as directed
Suppply and fixing ceiling fan complete with blade,dow rods electronic regulator ,with remote controller and accessories ,230V '1200 mm sweep. Min air delivery 210CFM with service value 6.00 BEE . five star rated with brushless direct current motor (BLDC) complete all as specified and as directd .
Supply and fixing PVC Exhaust Fan 200 mm with lovour complete all as specified and as directed.
M&L Sheet metal enclosures for DBs SPN 8 way with 200Amps rated busbar including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / indoasian
M&L of VTPN Vertical three phase distribution board, VTPN, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision for fixing of MCCBs as incomer up to 125 Amps and MCBs as outgoing complete all as specified and as directed .(Make: Indoasian or its equivalent/legrand /CG )
Supply and fix of MCCB 4P 63 Amps /415Volts ,having breaking capacity with complete accessories as per existing suitable size complete all as specified and as directed
M&L MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. Make of Legrand or equavalent to HAVELLS / SIEMENS/indoasian
M&L MCB SP 6-32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. Make: Legrand or equavalent to HAVELLS / SIEMENS/indoasian
All as per ser item No 2.00 but for one light point controlled by two way switch.
M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
S&F Bell switch AC, 230 Volt single pole
S&F switch piano, flush type, 16 amps single pole, one way
S&F socket, flush type, 5 pin, 16 amp multi purpose.
S&F switch piano Two way flush type, 05 amps single pole, one way
Supply and fixing of steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. As per existing make requied complete all as specified and as directed.
M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 10.00 sqmm main cable and one RM of 10.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Supply and fix of LED lights fitting 1x10W, 220V,AC decorative a decorative LED fixture with curved diffuser and extunded polycarbonate channel,environment friendly,energy efficent ,ready to use pack complete all as specified and as directed .
S&F Recess mounting type LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 35 watt to 36 watt (cool white), minimum system lumen efficacy not less than 100 lumper watt, CRI not less than80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver IP protection IP 20, powder coated housing with ashthetic bottom frame, suitable for any type of ceiling system including connection with PVC insulated copper conductor complete all as specified. (Make Havells/Bajaj/CG or its Equivalent.)
S&F LED light fitting 1X10W bulk head luminaires aluminium die casted including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.(Make Havells/philips/Wipro)
Supply and fixing of LED street light fitting 35 Watt 6500K pf >.90 efficency 100lm/W 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp fixing of wall,pole,building with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and as directed.
Supply and fixing of street light bracket made out of 30/32 mm dia GI light grade tubing not less than .75 Mtr long bend to shape including pole clamps/fastners clips nails made out flat iron and nuts, bolts and washers etc complete all as specified and directed.
M&L of single pole and earth encloser with three pin and earth plug plus neutral with socket 32/40 Amps 240Volts complete indrustial type with Tripple pole MCB complete all as specified and directed IP-30 protation
M&L of sheet metal enclosures double door for DBs SPN 12 way 240 Volt with 200 Amps rated Busbar including accessories therein and disposing off complete all as specified and directed.(Make: Indoasian or its equivalent/legrand /CG )
M&L MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. .(Make: Indoasian or its equivalent/legrand /CG )
M&Lof MCB TPN 40-63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.(Make: Indoasian or its equivalent/legrand /CG )
Supply and fixing of MCCB 4P 100 Amps /415Volts ,having breaking capacity with ,omplte accessories as per existing suitable size complete all as specified and as directed
Supply and fixing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 95 sqmm 3.5 core laind in trenches or passing through pips/ ducts complete all as specified and directed by Engineer in charge
M & L for Sand cushioning for 8 cm before laying the cable and then after laying the cable 15 cm width of trenches for protection of cables including punning down complete all as specified. Note :- Thickness of sand cushioning shall be the thickness after punning down.
M&L Earthing complete with copper earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth electrode burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth strip 20 x 3 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including brazing etc of earth electrode and earth wire by means of welding, all as directed including providing watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion. .
M& L Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm x 3.15 mm thick as earth burried directly in ground (earth pit not less than 2.25 Meter deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level using copper earth lead wire 4.0 mm dia as earth continuity conductor connected to earth plate by means of copper thimbles, nuts, bolts, washers including jointing of earth electrode and earth wire by means of welding, all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and pit cover made of MS sheet 2 mm thick duly fixed to angle iron frame with hinges of appropriate size by welding and having locking arrangement, adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil , removing surplus excavated material all as required at site and as specified in EP No 3 of MES SSR Part-I (2009) directed by Engineer-in-charge including testing on completion.
Supply and fixing Digital Grounding Device Mobile Transporatble Earthing Pit Advance Chemical Sealed Electrode Box Type light weight (Generation-5) Advance Chemical Sealed Electrode Box Type light weight GI horizontal electrode designed for use in any type of soil condition. Each electrode to be designed in box shape using GI,2mm thick plates of 600x450mmx100mm as outers of the box. two 50mm sockets are to be placed on top with removable caps and two handles to faciltate hanging. The inner space between plates is to filled with about 28 KG of Specialized ASEM-GB an extremely low resistvity (0.05ohm/m & below) (High Conductivity) hygroscopic, non- soluble stable material. The material is filled in the electrode in very slury form made with water. After filling the high conductive salt in the box both the sockets are crapped and closed. A cu terminal 200x40x6mm is to be fixed along the centre protruding on the socket centre the necessary connection/bonding. A 1.5 mtr length of PVC insulated 50 sq mm Copper Flexible cable is to be provided with each electrode for necessary connection to Distribution Bvox or bonding between two electrodes. One galvanized iron sheet junction/Distribution Box is to be provided with every two electrodes. The electrode Duplicacy/copy of the Equipment is subject to legal content
Earth continuity conductor 20 x 3.00 mm copper strip or main earthing lead fixed to walls on batten or recess or chassis or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed by Engr-in-Charge
Supply and fixing of Earth continuity conductor or main 4 mm Galvanised iron wire fixed to wall on batten or recess or chases including or drawn in conduit/pipe or fixed to poles or any other indicatedsituation for loop earthing etc. Complete all as specified and as directed
M&Lof GI tube light grade of bore 40 mm with all fittings and fixed complete to walls and ceiling or laid in floor for cable crossing including cutting of bitumen roads/PCC and making good after laying of cable up to building height complete all as specified and directed
M&Lof Mild steel powder coated corrugated black sheets of size 30 cm width as cable duct trays and similar work cut to size holes punched including round headed screws clout nails or rixet rivets and fixed to wood or steel framing with plain 40mm lap joints with revetted seams including bending or truning up mitered angle etc. as required of 3.15mm thick sheet complete as as specified and as directed
Supply and fixing of DWC HDPE tubing 40 mm including all fitting/fixtures such as Tee/Elbow/Socket/ Nipple etc.Conforming to IS 16205 bore for laying cable, cut to size and making the tubing for cable protection along with drawn in cable into the HDPE tubing on the surface/on the wall /along drainage etc cutting of road etc cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. Note :- (a) The using of GI Clamp in the wall/drainage,etc rate are deemed to be included in the quoted rate and nothing shall extra paid to contractor.
M&L of Test Point Terminal Block made of Gun Metal or Phosphorus Bronze size 75x75x25mm, drilled and screwed including 3 No. 8mm dia, 25mm long hexagonal Head Screw, complete all as per specified and as directed.
M&L for supply and pouring of RoHS tested Earth Enhancement Compound after mixing with water tested by NABL accredited lab in compliance to IEC 62561-7 with a resistivity < 0.12 ohm-m. It shall be free from bentonite and other hazardous substances. It shall be a permanent, non-corrosive material and will not leach any chemicals into the ground. It shall retain moisture even in high soil resistivity areas. complete all as specified and as directed. Make: JMV or Equivalent as approved by GE. Note: Measurement of Chemical will be done in Powder form.
Supply and install Wall Mounted hot and cold inverter Split Ac 1.5 Ton including indoor/outdoor unit complete with cordless remote control unit and with cooling and heating function of capacity of 1..5 ton BEE 5 Star Compressor Type rotary BLDC copper condenser coil Better cooling and requires low maintaince special features Dust filter ,Air Purifier and connecting copper pipe & connecting cable complete of Engineer-in-Charge, all as directed.
Supply and fixing of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB(20 AMP) complete allas specified and as directed
Supply and Fixing Sheet metal enclosures for DBs SPN 2 way (when MCBs to be used) flush mounted including necessary fitting to the SPN complete all as specified and directed by Engr-in-Charge.
Supply and fixing of MCB SPN 32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' charactersticks and current carrying apacity in the MCB complete with testing and commissioning as specified and as directed. Make:CAT PART NO:408617 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
S&F Split AC stand wall mounting Bracket stand with 2 mm thick hifh grade steel and load carrying capacity upto 160 Kgs complete all as specified and directed by engr-in-charge
S&F Drain outlet pipe OF 3 mtr long for indoor unit complete all as specified and directed by engr-in-charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA
Supply and fix deep freezer of capacity 350 ltrs double door single phase 230 volts 50 Hz complete all as specified and directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90V to 300 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA
M&L perforated angle of size 40x40x4mm powder coated for holding of cable trays with complete nuts and bolts and washer to match with colour with cable tray complete all as specifed and as directed by Engr-in-Charge
Common burnt sub class 'B' brick laid in trenches over and across the length of cable with length of brick perpendicular to the direction of cable complete all as specified and as directed by Engr-in-Charge
M/S VERINDER KUMAR GUPTA
KARAN TRADERS
VISHWA MITTAR PACHYALA
PARAS RAM ASGOTRA AND SONS
ANIKET TRADERS
Bidder Name
ANIKET TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .