| 1 | L1₹27.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.1 L+₹2.6 L (9.37%)Rejected-Finance | L2 | Rejected-Finance NOT REASONABLE | |
| 3 | L3₹31.3 L+₹3.7 L (13.6%)Rejected-Finance | L3 | Rejected-Finance NOT REASONABLE | |
| 4 | L4₹32.1 L+₹4.6 L (16.6%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance NOT REASONABLE |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Jul 2024, 6:00 pmClosed
Saurabh Gupta, EE
GE (W) Colaba, Mumbai
REPAIR/ REPLACEMENT OF LT CONTROL PANELS, STARTER PANEL, CABLE CONTROL VALVE, PRIMMING TANKS AND CHLORINATION SYSTEM OF PUMP HOUSE INCL CONNECTED ITEMS UNDER GE(W) COLABA.
2024_MES_661257_1
8899/E8
Open Tender
Civil Works
Item Rate
180 days
GE (W) Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹90,000
Yes
2 Sept 2024
21 Jun 2024
20 Jul 2024
21 Jun 2024
18 Jul 2024
4 Jul 2024
Amount
Supplying, laying, testing in repairs FR multistranded single core copper three run conductor of size 6 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible pvc pipe in concealed wiring with brass thimbles/lugs, nuts, bolts, washers all as specified & directed.
Supplying, laying, testing in repairs FR multistranded single core copper three run conductor of size 10 Sqmm PVC sheathed un-armoured,1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible pvc pipe in concealed wiring with brass thimbles/lugs, nuts, bolts, washers all as specified & directed.
Supplying, laying, testing in repairs FR multistranded single core copper three run conductor of size 16 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible pvc pipe in concealed wiring with brass thimbles/lugs, nuts, bolts, washers all as specified & directed.
S&F in repairs 2000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top triple layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size all as specified and directed.
S&F in repairs 1000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top triple layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size all as specified and directed.
S&F in repairs 500 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size all as specified and directed.
Taking up/down Old unserviceable GI pipe 15 mm bore with all fittings from trenches / ducts / walls / floors / ceilings all as specified and directed.
S&F GI pipes medium grade 15mm bore with all fittings / GI bends laid in trenches all as specified and directed
S&F in repairs sluice valve confirming to IS 14846 : 2000 CI body SS Spindle PN 1.6 ISI marked flanged ends for 80 mm bore pipe fixed with GI nuts, bolts, washers, rubber gaskets all as specified and directed.
All as per item No 9 above but 100 mm dia bore
All as per item No 9 above but 150 mm dia bore
S&Fin repairs butterfly valve confirming to IS 13095:1991, CI body, PN 1.6 ISI marked, flanged end for 80 mm bore pipe fixed with GI nut, bolts, washers, rubber gasket all as specified and directed.
S&F in repairs non return valve, confirming to IS 5312:2004, CI body, for 150 mm dia bore pipe, ISI marked, flanged both ends, PN 1.6 rating, fixed with GI nuts, bolts, wahsers, rubber gasket all as specified and directed.
All as per item No 13 above but 100 mm dia bore
All as per item No 13 above but 80 mm dia bore
All as per item No 13 above but 50 mm dia bore
Supplying, laying, testing & commissioning of LT under ground XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade 3.5 core X 35 sqmm laid in ducts fixed with saddle & clamps or passing through pipes complete with brass compression gland & proper lugs, nuts, bolts, washers all as specified & directed.
S&F in repairs Fully automatic star delta starter with single phase preventor for up to 20 HP pump all as specified and directed.
S&F in repairs dol starter with single phase preventer for mono block pump set upto 5 HP capacity all as specified and directed.
S&F in repairs digital soft starter 70 HP capacity complete any make suitable for exsting panel /makeall as specified and directed.
M&L Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level and connected to GI earth lead strip 32 x 6 mm by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No 3 of MES Schedule part-I, earth lead strip connected to indicated position including concrete pit in PCC (1:3:6, type C1), Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe "medium grade" for watering with GI funnel and wire mesh including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil all as specified and as directed and testing on completion.
M&L in repairs for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6mm dia galvanised iron or steel wire complete including taking down old cable all as specified and directed
M&L in repairs test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed.
S&F mild steel Joist, channel, angle or tee sections, fixed independently, without connecting plates etc, (cut to ordinary length of Fe 410-W-(Gde-E-250) quality-A, for making ladder of OHT tanks including dismantling/taking out old item/material all as specified and directed.
S&F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment including preparation of surfaces and applying one coat of primer and two coats of synthetic enamel paint all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for all as specified and directed
M&L PCC (1:2:4), type B2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete as in motor foundation all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortar or cement lime mortar including all quoins all as specified and directed
M&L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 at various locations in repair works all as specified and directed.
M&L rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces all as specified and directed.
S&F in repairs Battery 12 V 180 AH model No XP 1800 including taking down old of exide or equivalent all as specified and directed
S&F in repairs pad lock 50 mm dia with minimum double key, seven lever, made out of hardened brass and rust resistant internal components all as specified and directed
S&F in repairs Battery 12 V 130 AH model No XP 1300 of Exide including taking down all as specified and directed
S&F in repairs pressure gauge 150 mm dia range 0-10 kg/Sqcm all as specified and directed. Note : Rate quoted shall be deemed to be included for providing adopter/Ferrule/check nut etc required for fixing of pressure gauge.
S&F in repairs MCCB's 3 Phase (TP) 200A 50Hz, 36 KA fixed in existing panel board all as specified and directed.
S&F in repairs MCCB's 3 Phase (TP) 100A to 160 A 50Hz, 30 KA fixed in existing panel board all as specified and directed
S&F in repair MCCB's 3 Phase (TP) 63A 50Hz, 30 KA fixed in existing panel board all as specified and directed
S&F in repairs MCCB's 3 Phase (FP) 200A 50Hz, 36 KA including suitable size sheet metal enclosure all as specified and directed
M&L in repairs testing Compact Motor Protection MM 10 relay for Medium & Large Size Motors Relay a microprocessor based Motor Protection Relay with 4 digits LED Display, Protections for Thermal Overload with Warning, Short Circuit, Under Current, Unbalance, Phase Loss, Phase Sequence Reversal, Earth Fault, Prolong Starting, Locked Rotor and Features of 4 Digit LED display, Measurement of RYB, Zero Sequence current and Thermal capacity, Separate LED’s for indication of Motor operational, Trip & Thermal OL/ pre-alarm, 2 nos ,1 no. Programmable Binary input for remote operation. of C/O output contacts. status, Programmable thermal OL time constant right from 1 sec to 40 sec, configured for operations of Trip Reset, Instant Tripping, Relay testing facility, Trip data recording Fault current or cause of last trip is displayed including suitable size current transformer for functioning motor pump , complete including taking down old all as specified and directed by Engineer in charge.
S&F in repairs LED indicator suitable motor panel (RYB) type all as specified and directed.
S&F in repairs digital Amp meter 0 to 100 Amps suitable motor panel (RYB) type all as specified and directed
S&F in repairs Thermal over load relay ML type 14-32 A all as specified and directed
S&F in repairs Thermal over load relay MN type 30-50 A all as specified and directed
S&F in repairs Voltmeter/ Amp meter digital type of showing reading 0 to 500 Amps/volts suitable motor panel (RYB) type all as specified and directed
S&F in repairs Copper busbar of capacity 150/240 amp for each phase & neutral suitable size insulator, nut , bolts motor panel (RYB) type all as specified and directed
M&L for cleaning of fire chamber / Valve Chamber in area and remove all debris / plastic etc from chamber and thrown away outside of army area and painting of chamber plate red / Black colour including transport carrying debris all as specified and directed
S&F in repairs main contactor ML 4, 3 Pole all as specified and directed
All as per items No. 52 above but ML 3, 3 Pole all as specified and directed
All as per items No. 52 above but MNX 70, 3 Pole all as specified and directed
Supply, fixing and testing altoch dozing system model No ADS-PRO including branch connection with all connecting material, suitable size pipes, electric connection including taking down old all as specified and directed
Supply only chlorine refill casul Stequa 411 AE Refil including taking down old all as specified and directed
Supplying, laying, testing & commissioning of LT under ground XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade 3.5 core X 120 sqmm laid in ducts fixed with saddle & clamps or passing through pipes complete with brass compression gland & proper lugs, nuts, bolts, washers completed including taking down old all as specified & directed.
All as per item no 59 but 3.5 core X 95 sqmm
All as per item no 59 but 3.5 core X 70 sqmm
All as per item no 59 but 3.5 core X 50 sqmm
S&F in repairs of LED security light driver suitable for 50 watt to 100 watt of 100 lumen per watt IP 65 of 6000k/3000k as per requirment on site including necessary fixing arrangement all as specified and directed.
S&F in repairs of LED security light driver suitable for 100 watt to 200 watt of 100 lumen per watt IP 65 of 6000k/3000k as per requirment on site including necessary fixing arrangement all as specified and directed.
N.S.ENTERPRISES
Panther Facilities
shree arihant constrution
Bidder Name
NOEL ENGINEERS
shree arihant constrution
Panther Facilities
N.S.ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .