| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-AOC 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.1 L+₹88,567 (7.92%)Rejected-Finance | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹12.4 L+₹1.2 L (10.7%)Rejected-Finance | L3 | Rejected-Finance Higher Bidder | |
| 4 | L4₹12.8 L+₹1.6 L (14.6%)Rejected-Finance | L4 | Rejected-Finance Higher Bidder | |
| 5 | L5₹15.6 L+₹4.4 L (39.2%)Rejected-Finance | L5 | Rejected-Finance Higher Bidder |
Tender Value
₹18.5 L
EMD Value
₹37,000
Closing Date
26 Jan 2022, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR MAINTENANCE OF INTERNAL WIRING INCLUDING FITTING AND FIXTURES CEILING EXHAUST FANS MCB DBs EARTHINGS AVIATION FLOOD LIGHTS AND CONNECTED WORKS FOR BLDGS OF HANSA VIHAR INCLUDING CAVALIOSIM NDB CORTALIM AREA AND NTS AREA UNDER AGE EM I OF GE
2021_MES_498021_1
85553/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (NW)VASCO
₹37,000
Yes
17 Feb 2022
29 Dec 2021
28 Jan 2022
29 Dec 2021
26 Jan 2022
12 Jan 2022
Amount
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches, ceiling roses, pendants, regulators, bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed.
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC Casing & Caping double lock type of as required width (not less than 20 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 2mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers and including provision of modular metal flush box, modular cover plate with frame top cover for mounting switches, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
All as per item No. 2 here in before, but for one fan/exhaust fan point controlled by one bell push 5 Amp complete all as specified and as directed.
All as per item No. 2 here in before, but for one bell/buzzer point controlled by one bell push 5 Amp complete all as specified and as directed.
All as per item No. 2 here in before, but for one light point controlled by two 2-way switches complete all as specified and as directed.
All as per item No 2 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
M&L for point FRLSH/LS wiring with 1.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in and including steel conduit on surface with all fittings and fixing materials and PVC insulated multistranded copper earth continuity conductor of size 1.5 Sq mm connecting etc for one light/Exhaust fan point complete all as specified and directed by Engr-in-charge.
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC Casing & Caping (double interlock type) of as required width (not less than 20 mm in width) ISI marked medium duty, white colour with all accessories of same grade, fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 2mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers and including provision of modular metal flush box, modular cover plate with frame top cover for mounting switches socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed
S & F in repairs switch piano flush button single pole one way 5 A , 240 V complete all as specified and as directed
S & F in repairs switch piano flush button single pole two way 5 A , 240 V complete all as specified and as directed
S & F in repairs modular switch single pole one way 6 A, 240 V complete all as specified and as directed
S & F in repairs modular switch single pole one way 16 A, 240 V complete all as specified and as directed
S & F in repairs modular bell push single pole, one way, 240 V, 6 A complete all as specified and as directed
S & F in repairs switch socket combination 2 in 1, 5 Amp flush type, 240 V, complete all as specified and as directed
S & F in repairs modular socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed
S & F in repairs switch socket combination 5A/16A, 5 in 1, 3 pin, 240 volts complete all as specified and as directed
S & F in repairs modular socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 volts complete all as specified and as directed
S&F in repair ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
S & F in repairs call bell ding dong AC,230 volts, single pole complete all as specified and as directed.
S & F in repairs stepped type electronic fan regulator flush type as per existing model on the existing board complete all as specified and as directed.
S & F in repairs stepped Modular electronic fan regulator flush type on the existing board complete all as specified and as directed.
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed. Note: Three runs of 2.5 sqmm cable and one run of PVC casing and capping shall be measured as one run.
M & L for sub main wiring with two runs of single core 4 Sqm, FRLSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed. Note: Three runs of 4 sqmm cable and one run of PVC casing and capping shall be measured as one run.
M & L for sub main wiring with two runs of single core 6 Sqm, FRLSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed. Note: Three runs of 6 sqmm cable and one run of PVC casing and capping shall be measured as one run.
M & L for sub main wiring with four runs of single core 6 Sqm, FRLSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with two runs of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed. Note: Six runs of 6 sqmm cable and one run of PVC casing and capping shall be measured as one run.
M & L for sub main wiring with four runs of single core 10 Sqm, FRLSH Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing capping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with two runs of 10 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as specified and as directed. Note: Six runs of 10 sqmm cable and one run of PVC casing and capping shall be measured as one run.
Taking down unserviceable any type of main switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and as directed.
S & F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed.
All as per item No 30 here in before but MCB DB SPN 4 way DB 230 V with 200 A rated bus barcomplete all as specified and as directed.
All as per item No 30 here in before but MCB DB SPN 12 way DB 230 V with 200 A rated bus bar complete all as specified and as directed.
S & F in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connections complete all as specified and as directed.
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB TPN 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
M & L for exhaust fan AC single phase 230V of size 300 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan complete all as specified and as directed.
S & F in repairs energy efficient surface mounted LED luminaire 20 watts 4' long, with acrylic cover complete with all accessories incl. necessary two core copper wire for connection from ceiling rose to connector of approx. length 0.75 mtr complete all as specified and as directed.
S & F in repairs energy efficient surface mounted LED luminaire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx. length 0.5 mtr complete all as specified and as directed.
Supply & fix surface/recess mounting high lumen LED flat panel 1'X1' 18 Watt, white powder coated CRCA housing with high-power LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed.
Supply & fix recess / surface mounting high lumen LED flat panel 2'X2' 36 Watt, white powder coated CRCA housing with highpower LEDs , aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V,complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and as directed.
Taking down old unserviceable CFL bulb and Supply and fix retrofit LED bulb 12/15W 240volts,50Hz, including removing old unserviceable item complete all as specified and as directed.
S & F in repairs LED aviation light comprising of aluminium housing with polycarbonate enclosure, 302 Nos. LED are provided with necessary fixing arrangements & electrical connections complete all as specified and as directed.
S & F in repairs 1 x 60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights complete all as specified and as directed.
S & F in repairs 1 x 90 watts LED building security light made up of pressure die cast housing with toughed glass and individual LEDs with secondary optics and IP66 protection for building security lights complete all as specified and as directed.
M & L for street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc complete all as specified and directed.
Taking down of existing UNSV flood light fitting of any type, supply and fix LED Flood light fittings 200 Watts incl fixing arrangement and ncluding connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded, necessary connections complete all as specified and directed by Engr-in-charge.
Taking down of existing UNSV flood light fitting of any type, supply and fix LED Flood light fittings 180 Watts incl fixing arrangement and ncluding connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded, necessary connections complete all as specified and directed by Engr-in-charge.
M & L for earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts,check nuts and washers of brass as shown in electrical plate No. 3 of SSR part I including necessary excavation and earth work, GI Pipe 20 mm bore light grade for watering with Funnel,wire mesh, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt etc including testing and taking out old unserviceable any type complete all as specified and as directed. Note: GI earth wire 4 mm upto 7.5 RM is included in the unit rate quoted
Taking down ceiling fan 1200/1400 mm sweep of any make from its existing position after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts and washers etc and replacement of spare parts/accessories such as ball bearings, gun metal bushes, capacitor, canopy top and bottom, shackle clip assembly, rewinding of fan motor, painting and including hanging/ fixing back in existing location and making cable connections and testing for its satisfactory performance complete all as specified and as directed. Note: - Spate parts will be measured and paid separately
All as per item No 53 here in before but of exhaust fan of size upto 300/380 mm sweep complete all as specified and as directed.
Supply only fan capacitor 2.5 / 3.15 mfd, 240 volts, 50Hz complete all as specified and as directed.
Supply and fix in repairs only ball bearing suitable for ceiling fan/exhaust fan/air circulator/pedestal fan any type. complete all as specified and as directed.
Supply only shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan of any sweep complete all as specified and as directed.
Supply only PVC canopy top and bottom with tighten screw suitable for ceiling fan of any sweep complete all as specified and as directed.
Supply only split pin as per sample suitable for ceiling fan complete all as specified and as directed.
Supply only MS nut bolt with split pin as per sample and complete all as specified and as directed.
Supply and fix down rod made of MS pipe medium grade 15mm dia of 300/450/600 mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rod with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
Supply and fix copper conductor cable 3 core; 0.75 sqmm, PVC insulated, sheathed, flexible, multistranded,1100 volts grade for making connection to ceiling fan from ceiling rose complete all as specified and as directed.
Supply and fix galvanized louver shutter suitable for exhaust fan 300/380 mm sweep and fixing arrangement at outside of wall surface at any height complete all as specified and directed.
Material and labour for painting to ceiling fan of any sweep complete body, blades and down rod with two coat of synthetic enamel paint similar to match with existing colour after preparation of surfaces by using electric spray machine including marking of MES Number with black paint complete all as specified and as directed.
Material and labour for painting to exhaust fan complete body, blade assembly, frame of 300 mm sweep to 450 mm sweep with two coat of synthetic enamel paint by using electric spray machine similar to match with existing colour after preparation of surfaces including marking of MES Number with black paint complete all as specified and as directed.
Supply and Fix in repair ceiling fan motor with body complete suitable 1200 mm Sweep matching to blade of existing ceiling fan complete all as specified and as directed.
Supply and Fix in repair fan blade set of three suitable of any make and sweep up to 1200 mm sweep matching to existing ceiling fan complete all as specified and as directed.
Material and labour for rewinding of exhaust fan motor of 300/380 mm sweep with new supper enameled copper winding wire of existing gauge and number of turns and and applying insulated varnish assembling including removing burnt out copper winding wire complete all as specified and as directed.
Material and labour for rewinding of Flame proof exhaust fan motor of 300/380 mm sweep with new supper enameled copper winding wire of existing gauge and number of turns and and applying insulated varnish assembling including removing burnt out copper winding wire complete all as specified and as directed.
Removing old unserviceable blade assembly from exhaust fan and supply and fix new blade assembly suitable for exhaust fan 300/380 mm sweep and including locking nuts and testing complete all as specified and as directed.
S & F in repairs MCCB 125 Amps 16-18 KA ,415 V,50 Hz with suitable steel sheet enclosure indoor type complete all as specified and as directed.
Supply and fixing in repairs LED light fitting 1x40 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and as directed.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
DOGRA ELECTRICALS
S and G Constructions
Susheel Enterprises
Prabha Electricals and Communications
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .