| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1M/L LED light fitting 24 watts, 230 volts recess mounting type 300mm x 300mm size with extruded aluminum housing complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size. Halonix cat No. HLFPU11-02-24-CW or equivalent. (MAKE of: of WIPRO, SYS KA, HAVELLS) | |||||
| 2M/L LED light fitting 36 watts, 230 volts recess mounting type, 600mm x 600mm size with extruded aluminium housing complete with all accessories prewired and including connecting up with twin core twisted flexible copper conducted cable of suitable size. Halonix cat No HLFPU22-02036-CW or equivalent (MAKE of: WIPRO, SYSKA, HAVELLS) | |||||
| 3M/L LED tube light fitting single tube 1x20 watts, 230 volts and 1200 mm long epoxy powder coated, bipin holder, complete with all accessories, prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. (MAKE of: WIPRO, SYSKA, HAVELLS, HALONIX) | |||||
| 4M/L Highly energy efficient multi LED flood lignt 150 watts with pressure die cast aluminum housing reflector enclosed with toughened glass, IP-65, with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Halonix cat. No. HLFLD-ML01-150-CWL or equivalent (MAKE of:WIPRO, SYSKA, HAVELLS, PHILIPS, BAJAJ) | |||||
| 5A. SITC OF FIRE DETECTION & ALARM SYSTEM | |||||
| 5.01 | Supply, Installation, Testing & Commissioning of Wall recess mounted microprocessor based 4 Loop, Peer-to-Peer networkable analogue addressable Fire Alarm Control Panel with loop capacity up to 250 devices per loop, any combination of detectors & devices. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. On board 4 programmable input and output contract. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. facility of control module delay timer programmable. Minimum 1100 characters, 4.3" TFT display to indicate Fire/Fault Signal with address and analog output, inbuilt printer to print the log of all fire or fault events complete in all respects, four access level password protected, 7000 events historical logging with date and time, flash E-PROM. The panel shall have a built in power supply. battery charger and 24 volt sealed lead acid battery suitable operating the system for 30 min. in emergency condition. The panel has provision for integration with PA System for hooter complete as per specification. The Panel has provision for integration with building management system through Modbus complete as per specification. | - | Nos | - | - |
| 6REPEATER PANEL Supply, Installation, Testing & Commissioning of wall recess/surface mounting microprocessor based networkable analogue Repeater Panel which provide the same displays as the main display on the fire alarm control panels with minimum 1100 character, graphical back-lit 4.3" TFT display. Capability to connect to any node to annunciate the full network system or selected network nodes. The panel shall have LEDs for Alarm, Supervisory, Trouble and Monitor to sort events and shall also have common control switches and LEDs for Signal Silence, System Reset, Lamp Test, General Alarm and Acknowledge. The Repeater Panel should not reduce the maximum capability of the number of Main Fire Panels in the network. The Repeater Panel shall include the cost of all mounting accessories, connectors etc. and shall be as per specifications and the list of makes and complete as required. | |||||
| 7ADDRESSABLE SMOKE DETECTOR Supply, Installation, Testing & Commissioning of Plug in type analogue addressable Multi Detector with soft electronically addressing feature, visual alarm indicator (LED's) "Blink - red" in stand by and "Steady red" in alarm with twin LED for 360° view including detector base complete as per specification. | |||||
| 8ADDRESSABLE HEAT DETECTOR Supply, Installation, Testing & Commissioning of Plug in type analogue addressable Heat Detector with soft electronically addressing feature, visual alarm indicator (LED's) "Blink - red" in stand by and "Steady - red" in alarm with twin LED for 360° view including detector base complete as per specification. | |||||
| 9ADDRESSABLE MANUAL CALL POINT Supply, Installation, Testing & Commissioning of Analogue addressable Manual Call Point re-settable (Unbreakable glass) type with LED indication, visual alarm indicator (LED's) "Blink Red" in stand by and "Steady red" in alarm, soft electronically addressing feature and back box complete as per specification. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.58 MB
BOQ_879396.xls
BOQ • 0.38 MB
42.pdf
Tender Documents • 2.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].