Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.7 L+₹4.3 L (24.8%)Rejected-Finance 601 6TH FLOOR MANGOOR VALLEY NEAR GURUDWARA MANGOOR HILLL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹22.0 L+₹4.6 L (26.4%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹26.9 L+₹9.5 L (54.5%)Rejected-Finance | L4 | Rejected-Finance Higher bidder |
Tender Value
₹27.3 L
EMD Value
₹54,600
Closing Date
25 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
PETTY REPAIR WORKS OF INTERNAL AND EXTERNAL ELETRICAL DAY TO DAY COMPLAINTS AT INS HANSA UNDER AGE E M I OF GE NW VASCO
2021_MES_497933_1
85551/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (NW)VASCO
₹54,600
Yes
22 Mar 2022
29 Dec 2021
27 Jan 2022
29 Dec 2021
25 Jan 2022
11 Jan 2022
60 days
Amount
Petty repairs of day to day complaints of internal Electric supply for Tech Bldg at INS Hansa areas comprising the following items including testing and commissioning complete all as specified and all as directed:-
Supply and fix in repairs switch socket combinations 2 in 1 , 5 A ,3 Pin and 5 A, 2 Pin combined flush type complete all as specified and all as directed
Supply and fix in repair switch socket combination 2 in one, 3 pin, 5 A and 3 pin ,15 A combined flush type complete all as specified and all as directed
Supply and fix in repair switch Piano , flush type single pole one way 5 Amp complete all as specified and all as directed
Supply and fix in repair bell push piano flush type complete all as specified and all as directed
Supply and fix in repair buzzer , ding dong AC 230 V , Single pole complete all as specified and all as directed
Supply and fix in repair ceiling fan regulator stepped type 120 Watt single phase 230 V complete all as specified and all as directed
Supply and fix in repair MCB 6 to 32 A , Single pole 10 KA , 240 V/ 415 V, C Series complete all as specified and all as directed
Supply and fix in repair MCB , 4 Pole ,6- 32 A , 10 KA , 415 V , C-Series complete all as specified and all as directed
Supply and fix in repir MCB 4 Pole 63 Amps 415 V , C Series complete all as specified and all as directed
Supply and fix in repair single pole and neutral enclosure with two pin and earth plug and socket complex complete with one single pole MCB 20 Amps 10 KA complete all as specified and all as directed
Supply and fix in repair MCCB 4 Pole 100 Amps , 16 KA complete all as specified and all as directed
Supply and fix in repair RCCB , double pole 300 MA , 40 Amps complete all as specified and all as directed
S&F in repair ceiling rose, 3 phase/ PVC / polycarbonate, isolated body complete all as specified and as directed.
Supply and fix in repair lamp holder PVC / Polycarbonate type with pack plate suitable for battern fittings including fixing on suitable PVC Ractangular blocks complete all as specified and all as directed
Supply and fix in repair sheet metal enclosure suitable for mounting of MCCB 4 Pole 100 Amps, including fastner, nut bolts, conection wire and all other connected accessories complete all as specified and all as directed
Supply and fix in repair ceiling fan capacitor 2.5 MFD Single phase 415 V complete all as specified and all as directed
M&L for removing the ceiling fan , opening the fan motor servicing including replacement of worn out nut , bolts , washers , split pins , ball bearing etc greasing , assembling back and fixing its original position , testing and commssioning all as directed. Note: Ball bearing and sleeve bearing shall be measured and paid separately
Supply and fix in repair ball bearing suitable for any size of Ceiling Fans complete all as specified and all as directed
Supply and fix in repair plastic conopy top and bottom with tighten screw suitable for ceiling fan of any sweep/type complete all as specified and all as directed
Fixing only in repair highbay lights any type and capacity inside the hangar including necessary nut bolts complete all as specified and all as directed Note : Item will be issued by department at free of cost under Sch 'B'
Fixing only street lights of any type and capacity including necessary nut boltscomplete all as specified and all as directed Note : Item will be issued by department at free of cost under Sch 'B'
Fixing only LED tube rod , retrofit type including making necessary changes in wiring complete all as specified and all as directed Note : Item will be issued by department at free of cost under Sch 'B'
Fixing Only LED tube light fitting and tube light 1 x 18 Watts 4 feet long complete all as specified and all as directed Note : Item will be issued by department at free of cost under Sch 'B'
Fixing Only LED bolared/garden light 6 to 12 Watts complete all as specified and all as directed Note :Item will be issued by department at free of cost under Sch 'B'
Fixing Only LED Post top lantern 36 Watt complete all as specified and all as directed Note : Item will be issued by department at free of cost under Sch 'B'
Fixing Only astro timmer for street light and connected to all circuit complete all as specified and all as directed Note : Item will be issued by department at free of cost under Sch 'B'
Supply and fix in repairs LED tube light fitting and tube light 1 x 18 Watts 4 feet long , 230V indoor decorative aluminum extruded LED integrated batten, complete with all accessories internally pre- wired and including connecting up with twin core twisted flexible copper conductor cable with suitable sizes complete all as specified and all as directed
M & L opening the body cover of ceiling fan, exhaust fan, air circulator, pedestal fan any type , any make and cutting the existing winding without damaging the starter removing the coil insulation and putting new wire of suitable gauge with correct number of turns of auxiliary and main winding , varnishing and baking complete and soldering new lead of copper wire three core cables of size 23/0.0076 testing complete including transportation from area of AGE E/M I to workshop all as directed :-
(i) Ceiling Fan 1200/1400mm sweep
(ii) Exhaust fan up to 300 mm sweep
(iii) Exhaust fan up to 450 mm sweep
(iv) Flame proof exhaust fan up to 300 mm sweep
(v) Wall mounting fan up to 700 mm sweep
Attending complaints for day to day repair/maint work for Hangar light/ outer/inner perimeter/ security/ street/dispersal/ high mast/search lights /any description at INSHansa area by taking down carefully the existing non operational/ unserviceable lights from and description, repair/replacement of unserviceable spares and re-fixing the same in the existing location after completion of repair work complete all as specified and directed by Engr-in-charge. Notes :- (a) All new spares for the above lights will measured and paid separately under relevant item of this schedule. (b) The contractor/contractor's supervisor shall be report to AGE E/M- I/INSHansamaint office in all working days at 0900 AM and collect the complaint slip for defect/unserviceable lights list at Hansa premises and carrying out and complete the repair work in the same day before 1800 hrs. If the contractor fails to complete the repair work within the 03 working days after receipt of complaint slip necessary recovery @ Rs 100.00 per fittings per day shall be recovered from the actual workdone. For that the register shall be maintained and signed by both the Engineer in Charge and contractor.
(c) Rate for all Tools and plants, safety equipments, transport including necessary minor spares such as insulation tape, connectors, fixing screws, connecting 2 core wires up to 2 mtr length shall be included in the quoted rates. Note: New Spares will be measured & paid under relevant items as supply only
Supply only LED driver with transformer suitable for 25 to 45 watts LED street/ceiling panel light fitting of complete all as specified and directed by Engr-in-charge.
All as per item No. 30 here in before but of capacity 60 to 120 watts LED fittings complete all as specified and directed by Engr-in-charge.
All as per item No. 30 here in before but of capacity 150 to 300 watts LED fittings complete all as specified and directed by Engr-in-charge.
M & L for point wiring for one light point or one fan point controlled by one switch with 1.5 Sqmm PVC insulated 1100 V grade multistranded copper conductor in PVC Casing and Capping including provision of 1.5 Sqmm PVC insulated copper conductor as earth continuity conductor complete all as specified and as directed.
All as per item No.33 here in before but for one 5A socket out let on independent board complete all as specified and all as directed
All as per item No.33 here in before but for one 5A Socket out let on same board with other switches complete all as specified and all as directed
All as per item No.33 above but for one 15 A Socket out let with 2.5 Sqmm Copper conductor including provision of 2.5 Sqmm PVC Insulated copper conductor as earth continuity conductorcomplete all as specified and all as directed
Taking down unserviceable point wiring copper or Aluminium (light , fan , or Sockets) completely including making good disturbed surfaces complete all as specified and all as directed
M & L for painting of ceiling fans complete in site with synthetic enamel paint by spraying including filling cavities with filler , one coat after cleaning all dust etc complete all as specified and all as directed
Checking of ceiling fan complete in situ for proper fitment including. Checking of rubber reel , split pin , nut bolts , fan rod , fan clamp etc and replacement of defective / worn out split pin , nut bolts rubber red etc complete all as specified and all as directed
Periodical Inspection of Water Geyser 25 Ltrs / 50 Ltrs Capacity including checking of Built Safety valve , Neon Indiaction Lamp , Fussible metal plug Temperature Controlknob , Thermostate , thermal Cut out Heating Control etc for proper function and reset if required or replace if unserviceable all as directed. For replacement , item shall be measured and paid as supply only under relevant items:-
Supply only heating element suitable for existing Water Geyser of Capacity 25 Ltrs / 50 Ltrs of any make complete all as specified and all as directed
Supply only safety valve suitable for existing 25 Ltrs /50 Ltrs capacity water Geyser of any make complete all as specified and all as directed
Supply only thermostat suitable for 50 Ltrs /25 Ltrs Capacity water Geysers of any make complete all as specified and all as directed
Supply only thermal Cut out bimetallic type suitable for 25 Ltrs /50 Ltrs capacity water Geyser complete all as specified and all as directed
Supply only Neon Indication Lamp suitable for water Geyser on /off indication complete all as specified and all as directed
M & L for aluminium conductor , steel reinforced of any size as per site requirement including fixing on LT Pole Insulators , Jumpers etc including dismantling old U/S Conductor complete all as specified and all as directed
Attending electrical complaints like short circuit, No supply, wire burnt in switch boards etc. in residential accommodation /offices including fault findings, rectification and testing complete all as specified all as directed by Engr-In-charge. Note : Material like wire for replacement if required shall be measured and paid separately under supply only.
Supply only PVC insulatedmultistranded Copper Conductor Cable 1100 V grade 1.5 Sqmm size for day to day repair work complete all as specified and all as directed
All as per item No.48 above but of size 2.5 Sqmm complete all as specified and all as directed
All as per Item No.48 above but of size 4 Sqmm complete all as specified and all as directed
Supply and fix in repair LT Cable jointing kit outdoor type straight through joint of size 70 Sqmm to 120 Sqmm including necessary excavation upto 2.5 Cum and making good the excavated area complete all as specified and all as directed.
All as per item No.51 above for cable size 185 Sqmm to 240 Sqmm complete all as specified and all as directed
Attending Electrical Complaints such as , LT UG Cable end Connection burnt at substation , cutting and reconnection of LT UG Cable at substation , replacement of burnt LT UG Cable lugs etc.Complete all as specified and all as directed. Note: Cable lugs shall be measured and paid separately under supply only items.
Supply only LT UG Cable lugs Aluminium of size upto 50 Sqmm complete all as specified and all as directed
All as per item No.54 above but of size70 sqmm to 95 Sqmm complete all as specified and all as directed
All as per item No.54 above but of size 240mm complete all as specified and all as directed
All as per item No.54 above but size 185 Sqmm complete all as specified and all as directed
Servicing of 4 pole structures LT/HT including checking all joints , jumpers etc for any loose connection , replacement of burnt jumper with new one , replacement of rusted nut bolts and apply petroleum jelly for all moving contacts complete all as specified and directed by Engr-In-Charge. Note:- All the spares required for the work is included in the quoted rate.
Material and labour for servicing of earth pit structure by disconnecting earth strip by opening nuts and bolts 4 pole structures LT/HT including checking all joints ,jumpersetc for any loose connection , replacement of burnt jumper with new one , replacement of rusted nut bolts and apply petroleum jelly for all moving contacts all as specified and as directed by Engineer In-Charge. Note:- All the spares required for the work is included in the quoted rate.
Labour only for removing all vegetation and cutting of tree branches from electric poles of any size and length complete all as specified and all as directed
SHIVANI ENTERPRISES
Susheel Enterprises
Prabha Electricals and Communications
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .