Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 8 99 GROUND FLOOR GEETA COLONY NEW DELHI DELHI 110031 | SHAHDARA | DELHI | 110031 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹13,553
Closing Date
4 Aug 2020, 3:00 pmClosed
Executive Engineer
Executive Engineer (Electrical), Works Department, IIT Delhi, Hauz Khas, New Delhi - 110016
Name of Work- SITC of VRF / VRV System in Research Lab at Block 5/421 in IIT Delhi
2020_IIT_572824_1
IITD/WORKS(SP-3076)/2020
Open Tender
Electrical Works
Works
45 days
IIT Delhi, Hauz Khas, New Delhi
As per tender document
11 documents required · 11 mandatory
₹0
₹13,553
25 Aug 2020
22 Jul 2020
5 Aug 2020
22 Jul 2020
4 Aug 2020
22 Jul 2020
Amount
SUB HEAD 1 (SITC)
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50 Degree C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 (Make: Daikin / Blue Star / LG / Carrier)
Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V +/- 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 Degree C WB temperature. (Make: Same as that of VRF / VRV unit)
Supply, Installation, testing and commissioning including vaccumisation and nitrogen testing of following nominal sizes of soft / hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, Y-type joints wherever required, with adjustable with ring type hanger supports, jointing / brazing including accessories, insulated with XLPE class - O tubular insulation / woth Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines, all accessories as per specifications etc. as required:
NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The makes of tube fittings shall be same as that of tubes (4) The thickness of fittings used shall be same as that of the pipe
a) 19.0 mm OD with tube thickness 1.2 mm with 19 mm thick insulation
b)15.86 mm OD with tube thickness 1.2 mm with 19 mm thick insulation
c) 12.7 mm OD with tube thickness 1.2 mm with 19 mm thick insulation
d) 9.5 mm OD with tube thickness 1.2 mm with 19 mm thick insulation
e) 6.4 mm OD with tube thickness 1.2 mm with 19 mm thick insulation
Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with GI suspenders including GI bolts and nuts, etc. as required.
225 mm width x 50 mm depth x 1.6 mm thickness
Supplying and laying of ISI marked CPVC pipe of 1 inch dia for draining of sweated water from AC evaporator unit including providing tee, joints, elbows wherever necessary etc. complete as required. (Make: Finolex / Astral / Georg Fischer)
Fabricating, Providing and fixing M.S. iron frame fabricated with M.S. angle of size 50mm x 50mm x 6mm for resting the condenser unit on the outside wall / roof of the building duly supported from the bottom with same angle iron and finally making good the damages including painting the framework, minor civil masonry work, etc. complete as required.
Supplying and laying of ISI marked FR pvc insulated flexible copper cable of size 3 core x 1.5 sqmm of 1.1 kv grade including making connection etc. for communication between indoor and outdoor unit and other units, etc. through conduit complete as required. (Make: Havells / Skytone / Gloster / NICCO / Polycab / RR Kabel / KEI)
Supplying and laying of following size pvc insulated pvc sheathed armoured copper conductor cable including making connections etc. as required. (Make: Havells / Skytone / Gloster / NICCO / Polycab / RR Kabel / KEI)
a) 3 core x 4 sqmm
b) 4 core x 10 sqmm
Supplying and making end termination with brass compression gland and tinned copper lugs for following size of pvc insulated and pvc sheathed / XLPE copper conductor cable of 1.1 kV grade as required.
a) 3 core x 4 sqmm
b) 4 core x 10 sqmm
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
Supplying and fixing of 4 Pole DU100H type MCCB (Cat CM97933OOE2) with thermal release range 25-32 A, breaking capacity 30 kA with spreader terminals, rotary handle, in sheet steel enclosure size 1 for DU100H (cat no. CM90996OOOO) with mounting holes, DIN rail, louvres, duly factory painted for incoming supply to VRF/VRV unit etc. complete as required. (Make: L&T)
SUB HEAD - 2 (AMC) (Supplementary agreement shall be formed) under ARMO Fund
Routine, Preventive and Breakdown maintenance of 8 HP VRF/VRV AC unit including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units during the defect liability period of 1 year after date of commissioning as per maintenance schedule. (Completely free of cost): 1st Year
Routine, Preventive and Breakdown maintenance of 8 HP VRF / VRV AC unit including its all accessories, condensers, evaporator units, time to time checking of refrigerant leakage, electrical circuits, etc. for smooth operation of the entire AC units after defect liability period of 1 year from the date of commissioning as per maintenance schedule. Any breakdown shall be attended within 4 hours of reporting. Spare parts required during breakdown maintenance shall be arranged by the Institute. (N.B.: 01 Job means during a period of one year)
2nd year
3rd year
4th year
5th year
6th year
AM Cool Engineers and Consultants Pvt. Ltd.
TRANSCEND CONTRACTS PVT. LTD.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .