GARRISON ENGINEER (CENTRAL) KOLKATA T37 NAPIER ROAD HASTING KOLKATA 700022
REPAIR TO INTERNAL ELECTRIC WIRING INCLUDING FITTING FIXTURES CEILING FANS EXHAUST FANS AT SAHAPORE MIL CAMP UNDER GE (CENTRAL) KOLKATA
2023_MES_620668_1
8641/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (C) KOLKATA
₹42,000
Yes
8 Dec 2023
26 Sept 2023
24 Oct 2023
26 Sept 2023
23 Oct 2023
11 Oct 2023
26 Sept 2023 - 10 Oct 2023
Amount
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.complete all as specified and as directed by Engineer-in-Charge.
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
All as per item No. 2.00 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. 2.00 here-in-before but one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
S&F Socket outlet 3/5 pin, 6 Amps, 240 volt flush type complete all as specified and as directed.
S&F Switch socket combination multipurpose 2 in 1, 3 pin 6 Amps 230/240 volt flush type complete all as specified and as directed.
S&F Switch socket combination multi - purpose 3 pin, 15 amp and , 5 amp controlled by one switch flush type complete all as specified and as directed.
S&F Switch piano, flush type, Single pole one way, 5/6 Amps 230/240 Volts, white/ivory finish complete all as specified and directed.
S&F Ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed.
S&F Ceiling fan regulator electronic Step type, solid state, , 240 volts, complete all as specified and as directed.
S&F Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed.
S&F Call bell, ding dong AC 230 volts, single pole complete all as specified and as directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F Energy efficient LED fittings of capacity 20W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat no CIS-305-40-57SL / Havells Cat No-ENDURALINEARNEOBS20WLED865SPCWH/ Bajaj cat no-BCLAB20 or eqivalent
S&F Energy efficient LED fittings of capacity 10 W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat no CIS.103-10.3-SL / Havells Cat No-ENDURALINEARNEOBS10WLED830SPCWH/ Bajaj cat no-BCLSB 10 WH or equivalent .
S&F LED fittings with lamps of 30 watts for bldg security light IP 66 powder Coated pressure die cast aluminium compact high power LED street light with compact size & rough design 32 mm GI Bend including taking down old unserviceable one complete all as specified and as directed. Make :- Crompton Cat No LSTS-30-CDL-M /Bajaj cat no-ENXTP30LWHPO/Havells Cat No-ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC.
S&F Recessed mounted 2X2 LED luminaries 36 watt White powder coated luminaries with screw less design and bottom opening to give high aesthetic and ease of servicing including cutting the existing any type of ceiling and making the ceiling as per the existing ceiling after fixing the light fittings including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat no- LCTLSNE-36-FO-CDL/Bajaj cat no- BZRSQL 36W or equivalent
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
S&F MCB SPN DB made up with sheet metal single door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed.
S&F Sheet metal double door enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar complete including connection complete all as specified and as directed.
S&F Sheet metal double door enclosure for DB's when MCBs to be used 12 way single pole and neutral double door with 200 amps rated bus bar complete including connection complete all as specified and as directed.
S&F MCB TPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar,415 volts complete all as specified and as directed.
S&F MCB TPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 8 way TPN with 200 amps rated bus bar, 415 volts complete all as specified and as directed.
S&F MCB 6 to 32 Amps, SP, 240 Volts ,B- Curve breaking capacity 10 KA complete all as specified and as directed.
S&F MCB 6 to 32 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA complete all as specified and as directed.
S&F FP 63 Amps, 415 Volts ,C- Curve breaking capacity 10 KA complete all as specified and as directed.
Taking down and opening out the ceiling fan/wall mounted upto1400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots complete including materials like split pin,rubber reel etc reassembling and refixing of fan in same position or any other situation complete all as specified and as directed. Note : Spare parts shall be measured & paid separately under relevant item.
Rewinding of fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified and directed.
Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan of any make complete all as specified and directed.
Supply only capacitor of 2.5 mfd for Ceiling Fan complete all as specified and directed.
Supply only gun metal bush of suitable size for ceiling fan of sweep 1200mm/1400mm as per existing one complete all as specified and directed.
Supply only nuts, bolts, for Ceiling fan complete all as specified and directed.
Supply only shafts for ceiling fan suitable for 1200mm sweep complete all as specified and directed.
Supply only PVC connector for Ceiling Fan complete all as specified and directed.
Supply only rubber reel insulator for Ceiling fan complete all as specified and directed.
Supply only S hook as standered shape and size for fixing Ceiling fan complete all as specified and directed.
Supply only mild steel down rod 16mm dia ,1.5m long for fixing Ceiling fan complete all as specified and directed.
M&L Painting of ceiling fan/wall mounted fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified and directed.
Taking down and opening out the exhaust fan upto 400 mm sweep for inspection, removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, shaft, removing burnt out coils from the slots, cleaning and repairing of slots rubber reel etc. reassembling and refixing of fan complete all as specified and as directed. Note : Spare parts shall be measured & paid separately under relevant item.
Supply only bush suitable for exhaust fan complete all as specified and directed.
Supply only ball bearing suitable for exhaust fan.complete all as specified and directed.
Supply only capacitor 2.5 mfd for exhaust fan complete all as specified and directed.
Supply only shafts for Exhaust fan suitable for upto 450mm sweep complete all as specified and directed.
Supply only louver for Exhaust fan complete all as specified and directed.
Rewinding of exhaust fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified and directed.
Taking down carefully unserviceable geyser of any type and make from site after disconnections of water & electrical connections & carrying out to MES store yard for inspection and thereafter to workshop for repair & replacement of components such as heating element, thermostate, cable, neon lamp, plugtop, outer casing, plates & repair work to apparatus plate etc and carrying back to MES storeyard for testing and refixing at site and making water & electrical connection on completion and complete all as specified and as directed. NOTE: Spares shall be measured and paid separately under relevant item.
M&L Painting of geysers 25 ltrs capacity at site/at workshop with one coat of synthetic enamel paint (white) best quality including preparation of surfaces with brush, cleaning agents etc complete all as specified and directed.
Supply only following spares for geysers:- (a) Heating element 1.5KW including rubber gasket ISI marked suitable for existing geysers complete all as specified and directed.
(b) Heating element 2.0 KW including rubber gasket ISI marked suitable for existing geysers complete all as specified and directed.
(c) Heating element 1KW porcelain suitable for existing geyser 25/50 lit capacity complete all as specified and directed.
(d) Thermostate for suitable existing geyser of 25/50 litrs capacity complete all as specified and directed.
(e) Chromium plated copper pipe of length not less than 60cm including washers for incoming & outgoing water connections complete all as specified and directed.
(f) Apparatus plate assembly complete for geyser of capacity 25/50 litrs capacity complete all as specified and directed.
(g) Outer casing made out of 22 SWG MS sheet suitable for geyser of capacity 25 litrs complete all as specified and directed.
(h) Split plate bottom cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser complete all as specified and directed.
(j) Split plate Top cover made out of 22 SWG MS sheet suitable for 25 litrs capacity geyser complete all as specified and directed.
(k) Insulating material glass wool complete all as specified and directed.
(l) Element holding brass stud complete all as specified and directed.
(m) Element holding clamp complete all as specified and directed.
(n) Fusible metal plug complete all as specified and directed.
(o) Neon lamp round/square with connection lead complete all as specified and directed.
(p Non return valve 1/2" for geyser inlet complete all as specified and directed.
(q) Storage tank capacity 25 ltr complete all as specified and directed.
Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipe including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Earthing complete with GI pipe electrode, 40mm bore, medium grade, 2.5m length burried directly in ground vertically with top edge not less than 1.25 m below ground level connected to galvanised iron earth strip 32x6 mm by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 4 of MES Schedule Part I and testing complete inclduing taking down old one complete all as specified and as directed.
S&F Power supply unit consisting of starter with 11-18 Amp over load protection, MCB of 25 Amp with socket complete for AC 240 Volt single phase including taking down old unseviceable one complete all as specified and as directed.. Make: North west cat no- PU3M-FT /Havells cat no-AHOO323204 or equivalent in Siemens/ ABB/ Schneider.
S&F Existing energy efficient bulk head fitting decorative hexagon back lit LED luminaire comprising of high brightness LEDs and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed. Make:- Havells cat no- HEXAFT10WLED857SSYMBOPC /Bajaj Cat No-BIBWP10W/Magik etc.or equivalent
UNIVERSAL TRADING CENTRE
CONSTRUCTION AND MAINTENANCE ENGINEERING CORPORATION
SUDHA ENTERPRISES
INDIA ELECTRICAL EQUIPMENTS
SANTOSH INTERNATIONAL
R. D. Industrial
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .