AGM PLANNING
AGM PLANNING O/o GMT BSNL J.L.PURAM MYSORE
Providing Chemical Earthing, GI plate Earthing and Lightning conductor works for Phase IX.2 4G Project in Madikeri OA of Mysore BA
2024_BSNL_187021_1
NIT No. 461937 /KTK MY-17/18(14)/3/2024-HR ADMIN
Open Tender
Electrical Works
Works
365 days
AGM PLANNING GMT OFFICE MYSORE
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
AO CASH BSNL MYSORE
₹20,179
Yes
22 Mar 2024
17 Feb 2024
29 Feb 2024
17 Feb 2024
28 Feb 2024
17 Feb 2024
17 Feb 2024 - 20 Feb 2024
Amount
CHEMICAL EARTHING
Supply, Installation, testing & commissioning of Maintenance free Chemical Earthing with following components complete with excavation, civil works, including Labour Charges etc. as required. (Note:- The work has to be caried out as per RDSO specification NO. RDSO/SPN/197/2014 ) i) Earthing electrode shall be made of high tensile low carbon steel circular rod (UL listed), minimum 17.0mm diameter and minimum 3.0mtrs. long, molecularly bonded with copper on outer surface (minimum bonding thickness is 250 Microns). A hole of 100mm to 125mm dia shall be augered /dug to a depth of about 2.8 meters to place the Earth electrode. ii) Earth enhancement material (Non-bentonite) - 30-35 Kgs. After providing the Earth enhancement material around the electrode, remaining portion of the hole/pit shall be filled with the Back fill soil which is taken out during auguring / digging. iii) Copper strip of 300x25x6 mm, to terminate earth rod - 1 no (To be exothermally welded to earth electrode) iv) Construction of earth pit cover with heavy duty FRP Material/ Poly plastic of suitable size.
Supplying and laying of 35 sqmm multistrand single core PVC insulated copper cable on surface/recess/ in the existing pipe, from Main earth electrode to DC earth busbar i/c terminations with copper lugs etc.,as required (20mtrs / site)
Supplying and laying of 40 mm dia rigid PVC pipe on surface of wall / tray for mechanical protection of 35 sq mm cable, i/c providing clamps, cable ties, bends etc. as required (20mtrs / site)
Supply & Installation of Copper tape (25mmx2mm) OR solid copper round conductor (8mm dia) for interconnecting the main earth electrode and the other earth electrode of the Chemical Earthing System including earth enhancement material around the conductor, back fill soil etc as required. (This item shall be executed only if more than one chemical earth electrode is provided in a site) ( 1.5 mtr / site )
Providing and fixing of the 300mm x 50mm x 3 mm thick Copper bus bar as main earth bus bar on wall surface on suitable insulators having suitable no.of holes for connections complete etc., as required
GI PLATE EARTHING
Providing Earthing with G.I. earth plate of 600 mm X 600 mm X 6 mm thick including accessories at a depth of 3.75m as per Specifications, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required ( 3 mtrs / site)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required ( 20 mtrs / site)
Supplying and laying of 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) (For interconnection of existing earthings) ( 3 mtrs / site)
EARTH RECONDITIONING
EARTH STRIP CONTINUITY CHECK
Improving of earth continuity from existing earth electrode upto to the earth bus/ earth terminations by making good of loose connections/joints including providing missing bolts/nuts,spring washers etc.,as required.
MINOR MODIFICATIONS
Providing minor repair works for existing earth pit by making good of loose connections, cleaning GI strip surface of the terminals with sand paper and providing nuts,bolts,spring washers,water funnel and adding salt water to improve earth resitance value to one Ohm and providing earth manhole cover made of heavy duty FRP material and sign writing etc.,as required.
Providing and fixing of the 300mm x 50mm x 6 mm thick GI bus bar as main earth bus bar on wall surface on suitable insulators having suitable no.of holes for connections complete etc., as required
LIGHTNING CONDUCTOR
Providing and fixing of lightning conductor finial made of 25mm dia 1000 mm long GI pipe ( B-class) having single prong at top of the tower with suitable size GI base plate including holes etc.complete as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required (For horizontal run) (20 mtrs / site)
Providing and fixing 25 mm X 3 mm G.I. strip along the tower/Wall with suitable insulators /clamps fixed at suitable interval etc.,as required (For Vertical Run) (25 mtrs / site)
HRJ REFRIGERATION PVT LTD
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .