Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹14.1 L+₹78,308.22 (5.86%)Rejected-Finance 111 GB MARG YADAV ELECTRIC MARKET LUCKNOW UP 226018 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226018 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹14.2 L+₹83,754.97 (6.27%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹15.7 L+₹2.3 L (17.4%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹19 L
EMD Value
₹38,000
Closing Date
20 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BKT
GE (AF) BKT, LUCKNOW
REPAIR/ MAINT OF LT CABLE, LT DISTRIBUTION SYSTEM AND OTHER CONNECTED WORKS IN DOMESTIC AREA AT AF STN BKT
2023_MES_605193_1
8726/BKT/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BKT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) BKT
₹38,000
Yes
28 Mar 2024
23 Jun 2023
22 Jul 2023
23 Jun 2023
20 Jul 2023
6 Jul 2023
Amount
Servicing and repair / maintenance of LT panel Board including checking of MCCB,s, Bus bar , cable lugs, voltmeter, ammeter and CTcoil etc for healthy operation and repairs / replacement of MCCB, BUS bar, Voltmeter, Ammeter ,Current Transformers (CTs) and replacing of defective control wiring if any replacement of defective cable lugs and complete for Indoor type / Outdoor type LT Panel of various capacity including necessary addition/ alternation of panel including cutting/welding/hinges of front and back side of panel board /feeder to match the existing panel board/feeder Note:- Major spares like MCCB, Volt meter, Ammeter, Busbar and CT's, Epoxy insulator will be measured and paid seperately.
S&F in repair of MCCBs thermal magnetic including necessery fixing arrangement complete all as specified and directed, of capacity 100 Amps, 4 Pole, breaking capacity 25KA .
All as per item No 29 above but 160 Amps, 4 Pole, breaking capacity 36 KA .
All as per item No 29 above but 200 Amps 4 Pole breaking capasity 36 KA .
All as per item No 29 above but 250 Amps, 4 Pole, breaking capacity 36 KA .
All as per item No 29 above but 63 Amps, 4 Pole, breaking capacity 50 KA .
PCC 1:3:6 (nominal mix) type C-2 using 40mm graded crushed stone aggregates as in foundation filling land mass concerte for poles and stay/installation paths complete all as specified and directed.
M&L for Spray painting to existing LT panel board/Feeder pillar with two coats of synthetic enamel high glow paint Ist grade including preparation/cleaning of steel surfaces all as specified and directed.
Taking out old serviceable /unserviceable under ground cable from trenches/poles /pipe/floor of size 16 Sqmm 3.5/4 core to 25 Sqmm 3.5/4 core complete all as directed.
Ditto- to item No 6 above but of size 50 Sqmm to 120 sqmm 3.5 core
Supplying , laying , passing through pipe , connecting and testing UG cable XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 volts grade (Note:- Excavation , Earth Work pipe etc will be measured and paid sepretaly) XLPE Cable of size 16 Sqmm, 4 Core complete all as directed.
Ditto- to item No 9 above but XLPE Cable of size 25 Sqmm, 3½ Core .
Ditto- to item No 9 above but XLPE Cable of size 50 Sqmm, 3½ Core .
Ditto- to item No 9 above but XLPE Cable of size 70 Sqmm, 3½ Core .
Ditto- to item No 9 above but XLPE Cable of size 120 Sqmm, 3½ Core .
Reuse and laying only old cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm to 50 Sqmm 3.5/4 Core all as specified and directed.
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc complete all as sepecified and directed.
Returning filling in, soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing surplus excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation complete all as specified and directed. (Note:- punned thickness shall be measured only)
Supply and laying well burnt sub class ‘B’ bricks, locally best available laid in trenches for protection of underground cable complete all as specified and directed.
M&L for heat shrinkable jointing kit of 1.1 KV grade 25 Sqmm to 50 Sqmm x3.5 core XLPE cable including suitable size of connector complete all as per directed by Engr-in-charge. including necessary excavation and earth work , labour, Jointing kit complete, fixing charges & T&P including removing of grass/shrubs nearby the fault location all as specified and directed. MAKE:- M-seal, Raychem, CAB Seal, Denson.
All as per item No 19 above but for XLPE Cable of size 70 sqmm to 120 Sqmm x 3.5/4 core
All as per item No 19 above but for XLPE Cable of size 180 sqmm to 240 Sqmm x 3.5/4 core
Supply and fixing aluminium thimble , cable gland and lux after disconnecting from panel and taking down burnt cable from panel of different location and cutting out the burnt portion of cable and extended the cable from cable loop, preparation of cable including necessary connection and testing complete for 25 Sqmm 3.5 core to 50 sqmm 1100 volt grade sizes :-(Note : (i) 01 Job consisting of 04 Nos Lugs/thimble at one end of cable (ii) Rate of necessary Earthh work for opening of loop if requried at site are deemed to be included in the quoted rate )
Ditto complete all as per item No 21 herein above but size of cable 70 sqmm to 120 Sqmm 3.5 core 1100 volt grade.
Supply and fixing of OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and directed.
Supply and fixing of OFF LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 200 Amps complete all as specified and directed.
Taking down existing old LT panel board/ LT feeder pillar box comprising of MCCB & switch fuse unit of any capacity and size including bus bar ,ammeters, voltmeters etc after disconnecting all cable connection and removing from site complete all as specified and directed.
Supply, installing, commissioning and testing of Street light panel, 03 Phase, Max load 12 KW, provided with protection degree IP-54, in built short circuit protection, floor mounted, power coated weather proof mounted on angle iron stand of size 50x50x6 mm having minimum height 1.5 feet duly grouted or welded on floor, to accommodate (a) Time switch digital 24 hour -01 Nos (b) contactor 65 A TP -01 Nos (c) MCB rating 63 Amp TPN-01 Nos Make Havells Cat Part No- IHXTS09120 or equivalent (K) Termination of all cables with suitable size thimble and gland-1job all as specified and directed.
M&L for Earthing complete with copper earth plate electrode 600x600x3.15mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below ground level connected to copper earth lead strip 20 x 3mm size by mean of nut/bolt and washer of copper as shown in electrical plate no 5 of SSR part I including necessary excavation and earth work GI pipe 20mm dia light grade for watering etc, PCC pit chamber with PCC cover in cement concrete 1:2:6 Type C2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt etc including testing complete.
Supply and fixing in repair copper strip 20mmX3 mm complete with saddles and fixing screws for fitting the strip for earth continuity conductor complete all as specified and directed.
S&F steel tubular swaged poles complete with MS base plate of size 300 mm x300mm x 6 mm thick ,finial taper plug,bolts,nuts and screws as specified type 410 SP-31 (09 meters long) Including all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type (C-2) (using 40 mm graded stone aggregate ) in foundations of size 1.20 m X 0.60 m X 1.65 m below ground level PCC 1:2:4 type B- 1 (using 20 mm graded stone aggregate) in coping of pole of size 600 X 600 X 300 mm above ground level , removing surplus soil to a distance n. exc. 50 m & depositing where directed, including necessary form work and and providing 3 Nos of 30cm wide circular bands with Aluminium & blue paint starting from plinth level at a gap of 30cm in between 2 bands and numbering of poles, and numbering of the poles shall be done with synthetic enameled painted letter of shape & size alongwith two coat of alumininum paint over a coat of primer including pereparation complete all as specifed & directed.
Material & Labour for steel cross arms,angles,bracing supports,clamps and back plates fabricated from structual steel sections including nut bolts washers welding bending cold or hot drilling hole for bolts in any shapes or size as indicated or directed and inclusive of one primer coat and one finishing coat of silver paint.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC tape and overall PVC sheathed in service connection of size 10 Sqmm 2 core complete all as specified & directed.
Labour only for removing all vegetation for LT Panel/Feeder Pillar near of 2 Mtr all around and all as specified and directed. (Location- Airforce station Domestic)
Detection of pin point fault in LT cable (burried in ground/under road/path up to depth of 1.5 m) by cable fault locating machine comprising impulse generator,acoustic fault locator and reflectometer (laptop based) complete all as specified and as directed by Engr-in-Charge. Notes-(1) Cable fault locating machine to be arranged at site with in 12 hrs after intimation (2) Earth work will be measured seperatly.(3) Cost of transpotation in unit rate is deemed to be included. Location:-AF stn BKT.
Industrial Traders
MTR GROUP & COMPANY
Unnati Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .