| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹39.7 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹41.1 L+₹87,604.60 (2.18%)Rejected-AOC | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹42.5 L+₹2.2 L (5.60%)Rejected-AOC 16 20 GALI NO 7 8 SWAROOP NAGAR EXTENSION DELHI 110042 | DELHI | NORTH DELHI | DELHI | 110042 | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹48.3 L+₹8.1 L (20.2%)Rejected-AOC | L-4 | Rejected-AOC L-4 |
| Sl No | Description | Qty | Unit | Sree Ram Enterprises L4 | KKP Enterprises L3 | SARRAJ ENGINEERS AND CONTRACTORS L2 | SRK CONSTRUCTION L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling water tanks and removing to store capacity exc 500ltr n.exc 1000ltr complete all as directed and specified. | 20 | Each | 100 ₹2,000 Lowest | 155 ₹3,100 | 150 ₹3,000 | 950 ₹19,000 |
| 2.00 | Dismantling water tanks and removing to store capacity exc 1000ltr n.exc 2000ltr complete all as directed and specified. | 4 | Each | 300 ₹1,200 Lowest | 370 ₹1,480 | 350 ₹1,400 | 1,100 ₹4,400 |
| 3.00 | S&F Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity 1000Ltr complete all as directed and specified. | 20 | Each | 7,000 ₹1,40,000 | 7,520 ₹1,50,400 | 7,500 ₹1,50,000 | 6,000 ₹1,20,000 Lowest |
| 4.00 | S&F Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity 2000Ltr complete all as directed and specified. | 4 | Each | 18,000 ₹72,000 | 9,580 ₹38,320 | 9,500 ₹38,000 Lowest | 12,000 ₹48,000 |
| 5.00 | Supplying and laying in repairs of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified | 50 | RM | 200 ₹10,000 | 170 ₹8,500 Lowest | 200 ₹10,000 | 200 ₹10,000 |
| 6.00 | Supplying and laying in repairs of 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified | 40 | RM | 250 ₹10,000 Lowest | 280 ₹11,200 | 250 ₹10,000 Lowest | 300 ₹12,000 |
| 7.00 | Supplying and laying in repairs of 40mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified | 30 | RM | 350 ₹10,500 Lowest | 400 ₹12,000 | 400 ₹12,000 | 580 ₹17,400 |
| 8.00 | CPVC 25mm Male Brass Threaded Adaptor (MTA/ MBTA) complete all as directed and specified. | 20 | Each | 150 ₹3,000 | 200 ₹4,000 | 200 ₹4,000 | 40 ₹800 Lowest |
| 9.00 | CPVC 25mm Female Brass Threaded Adaptor (FTA/ FBTA) complete all as directed and specified. | 20 | Each | 150 ₹3,000 | 250 ₹5,000 | 200 ₹4,000 | 55 ₹1,100 Lowest |
| 10.00 | CPVC 25mm Tank Adaptor complete all as directed and specified. | 24 | Each | 150 ₹3,600 | 200 ₹4,800 | 200 ₹4,800 | 128 ₹3,072 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Apr 2026, 6:00 pmClosed
GE I RnD Delhi
MILITARY ENGINEER SERVICES GARRISON ENGINEER I RND LUCKNOW ROAD TIMARPUR DELHI 110054
CERTAIN MISC REPAIR INCLUDING WATER PROOFING STRUCTURAL REPAIR JOINERY ETC TO BLDG NO P4 P-6 P-10 ZONE A AND B OF KWC RESIDENTIAL AREA UNDER GE I RnD DELHI
2026_MES_756418_1
GE/RND/T-121/DLI/2025-2026
Open Tender
Civil Works
Item Rate
120 days
Delhi
Class-D, Cat a (i)
2 documents required · 2 mandatory
₹500
GE I RnD Delhi
₹80,000
24 Jun 2026
16 Mar 2026
15 Apr 2026
16 Mar 2026
8 Apr 2026
30 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling water tanks and removing to store capacity exc 500ltr n.exc 1000ltr complete all as directed and specified. | 20 | Each | - | - |
| 2 | Dismantling water tanks and removing to store capacity exc 1000ltr n.exc 2000ltr complete all as directed and specified. | 4 | Each | - | - |
| 3 | S&F Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity 1000Ltr complete all as directed and specified. | 20 | Each | - | - |
| 4 | S&F Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity 2000Ltr complete all as directed and specified. | 4 | Each | - | - |
| 5 | Supplying and laying in repairs of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified | 50 | RM | - | - |
| 6 | Supplying and laying in repairs of 25mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified | 40 | RM | - | - |
| 7 | Supplying and laying in repairs of 40mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified | 30 | RM | - | - |
| 8 | CPVC 25mm Male Brass Threaded Adaptor (MTA/ MBTA) complete all as directed and specified. | 20 | Each | - | - |
| 9 | CPVC 25mm Female Brass Threaded Adaptor (FTA/ FBTA) complete all as directed and specified. | 20 | Each | - | - |
| 10 | CPVC 25mm Tank Adaptor complete all as directed and specified. | 24 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
TDR.pdf
Tender Documents • 1.42 MB
BOQ_847295.xls
BOQ • 0.89 MB
corri.pdf
PDF • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .