| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAccepted-AOC | L1 | Accepted-AOC aoc | |
| 2 | L2₹52.1 L+₹2.0 L (4.03%)Rejected-Finance BOMDILA WEST KAMENG ARUNACHAL PRADESH PIN 790 001 | BOMDILA | WEST KAMENG | ARUNACHAL PRADESH | 790001 | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹52.2 L+₹2.1 L (4.21%)Rejected-Finance | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹53.3 L+₹3.2 L (6.40%)Rejected-Finance | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹54.0 L+₹3.9 L (7.83%)Rejected-Finance | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
28 Aug 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL BIRENDRA SINGH
GE 859 EWS PIN- 913859 C/O 99 APO
PROVISION OF CERTAIN B/R AND E/M WORKS AND SPECIAL REPAIRS OF DIFFERENT POCKETS AREA AT BAISAKHI OF AGE B/R P AND AGE E/M UNDER GE 859 EWS
2023_MES_610746_1
8450/E8
Open Tender
Civil Works
Item Rate
270 days
BAISAKHI
PL REF TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 859 EWS
₹99,000
Yes
29 Nov 2023
26 Jul 2023
29 Aug 2023
26 Jul 2023
28 Aug 2023
9 Aug 2023
Amount
Surface dressing n exc 15 cm deep in hard/dense soil with complete all as specified and directed
Surface excavation n.exc 30 cm deep & averaging 15 cm deep and getting out hard /dense soil with complete all as specified and directed
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m deep for foundation and getting out in soft/loose soil with complete all as specified and directed
Excavation in trenches not exc.1.5 m wide and not exc.1.5 m in depth for foundation or for shafts, walls, manholes etc not exc.10 Sqm on plan and getting out in hard /dense soil with complete all as specified and directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick, in hard/dense soil complete.
Removing excavated materials n exc 50m and depositing where directed at a level n exc 1.5m above the starting point.
M&L for Hard core, broken to gauge n exc 63 mm using broken stone or boulders complete all as specified and directed.
M&L for 75mm thick PCC type C-2, 1:3:6 (40mm graded aggregate) as in sub-base, floors and pavings etc complete all as secified and directed.
M&L for 75mm thick plain cement concrete 1:3:6 type B2 (using 40mm graded crushed strone aggregate) finished even and smooth without using extra cement as in plinth protection complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specifie as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment comlete all as secified and directed by Engr-In-Charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade with grey cement and pigment comlete all as secified and directed by Engr-In-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground levelr all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete
M&L for plain cement concrete type B-1, 1:2:4 using 20 mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edges comlete all as secified and directed by Engr-In-Charge.
M&L for PCC 1:2:4 type B-2 using (40 mm graded stone aggregate) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases).
M&L for Cement concrete type B-2, 1:2:4 (using 40mm graded agg) as in surface channels and drains complete all as specified and directed.
M&L for RCC 1:2:4 type B 1 (Using 20 mm graded aggregate ) Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete with complete all as specified and directed.
M&L for RCC type B1 1:2:4 (Using 20 mm graded aggregate for Columns, pillars, piers, posts and struts with complete all as specified and directed.
M&L for RCC type B1 ,1:2:4 (using 20 mm graded aggregate) for beams and the like with complete all as specified and directed.
M&L for RCC Nominal Mix type B-1, 1:2:4 (using 20mm graded stone agg) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
M&L for PCC 1:3:6 type C-2 (using 40mm graded stone agg) Cement concrete in surface channels and drains with complete all as specified and directed.
M&L for 40mm thick PCC type B- 1, 1:2:4 (20mm graded aggregate) in sub-floors, sub-bases, floors and pavings etc.
M&L for 25mm thick Pcc type B-2, 1:2:4 (using 40mm graded stone agg) as in sub base, floors and pavings complete all as specified and directed.
M&L Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter,add for fair finished .
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions with complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc with complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard / dense soil with complete all as specified and directed.
M&L for 100mm thick Cement concrete type C-2, 1:3:6 (using 40mm graded agg) as in foundations, filling and mass concrete
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete as specified.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
M&L for preparation of newly steel surface of any description, over 10cm in width or girth,not otherwise described with two coat of synthetic enamel paint over a coat of red oxide primer.
M&L TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Ditto all as per above item 36 but 6mm to 8mm dia.
M&L pre cast cement concrete solid block masonry with solid block exc 10cm in width block of PCC 1:3:6 type C1 and built in CM 1:6
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces with CM 1:4 complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on stone masonry surfaces or surface other than fair face of brick work of walls, finished fair & even.
M&L for rendering 15mm thick plaster on concrete surface in CM 1:6 and finishing surface even and smooth w/o using exta cement.
M&L for preparation of new plastered surfaces and applying two coats of cement base paint of approved shade on walls all as specified & directed by Engineer-in-Charge
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.
Dismantling of plain or corrugated steel sheeting any gauge, thickness as in roof covering complete all as specified and directed
Supply and fix, 0.63 mm thick corrugated galvanised mild steel sheeting (minimum 275gm/sqm galvanising) with two corrugations side lap, fixed with L type or J type or cranked hooks , bolts and washer in roof, complete, all as specified and directed.
Supply and fix 0.80mm thickness plain galvanised mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashing of (minimum 275gm/sqm galvanising) complete all as specified and directed.
Material and labour for preparation of new steel surfaces of any description, over 10 cm width or girth not other wise described including degalvanising with mordant solution and applying two coats of roof paint (CORRUGAL Brand of SHALIMAR PAINTS or Equivalent) over a coat of red oxide primer complete all as specified and directed.
M&L for mild steel work as in wind ties for roof covering including securing bolts etc. including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 290 Gde E-165 all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutter (without taking off shutter from the frame) exc 1.50 Sqm but n exc 4.0 Sqm each including iron mongeries complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frame) not exc 1.50 Sqm each including iron mongeries complete all as specified and directed.
Supply and fix 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete, all as specified and directed
S& F for 30mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats
S&F 2nd class HW 30mm thick Glazed and skeleton shutters, divided into squared, with plain, chamfered or roun0ded, mitred and rebated sash bars, any numbers open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
Supply and fix MS butt hinges medium weight, cold rolled 100mm size complete all as specified and directed.
Supply and fix MS butt hinges medium weight, cold rolled 75 mm size complete all as specified and directed.
Supply & fix Aluminium anodised barrel tower bolt 150 mm long of extruded section etc complete all as specified and directed.
Supply & fix Aluminium anodised barrel tower bolt 125 mm long of extruded section etc complete all as specified and directed.
Supply & fix Aluminium anodised barrel tower bolt 100 mm long of extruded section etc complete all as specified and directed.
Supply & fix Extruded Aluminium anodised alloy handles fabricated type 150mm long complete all as specified and directed.
Supply & fix Extruded Aluminium anodised alloy handles fabricated type 125 mm long complete all as specified and directed.
Supply & fix Extruded Aluminium anodised alloy handles fabricated type 100mm long complete all as specified and directed.
Supply & fix aluminium alloy, anodised, sliding door bolts 250mm size with hasp, staple (bolt type) and fixing clips of sheets , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed etc complete all as specified and directed.
Supply & fix sheet glass 4mm thick ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
Supply & fix sheet glass 3mm thick ordinary quality and glazing with oil putty in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as in sub base to floor finished fair & even all as specified and directed by Engineer-in-charge.
M&L for screed bed or bedding layer of 15mm thick in cement mortar 1:4 for laying floor tiles etc all as specified.
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.
M&L for 350 x 250 x7 mm or 450x350x7mm thick glazed coloured ceramic tiles on vertical surface of wall set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. (Make; Kajaria/ Orient Bell/ Johnson/ Somany). Note :- Colour and pattern will be decided by GE/Engr-in-charge. Contractor will bought the tiles only after approval of colour and pattern of tile by GE/Engr-in-charge.
M&L for light shade Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. (Note: colour and pattern of tile will be decided by GE/ Engr-in-charge. Contractor will brought the tiles only after approval of colour and pattern by GE/Engr-in-charge).
M&L for joint free Non - skid coloured Ceramic tiles 7 to 8 mm thick area of each tile exc 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. (Note: colour and pattern of tile will be decided by GE/ Engr-in-charge. Contractor will brought the tiles only after approval of colour and pattern by GE/Engr-in-charge).
M&L for joint free Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces etc set and jointed in neat cement slurry and pointed in white/coloured cement to match the shade . (Make; Kajaria/ Orient Bell/ Johnson/ Somany). Note :- Colour and pattern will be decided by GE/Engr-in-charge. Contractor will bought the tiles only after approval of colour and pattern of tile by GE/Engr-in-charge.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples
M&L for preparing plastered or unplasterd newly surface of any description with three coat of white wash on walls surfaces.
M&L for preparing plastered or unplasterd old surface of any description with two coat of white wash on walls surfaces.
Dismantling wall and ceiling boards of any description including cover fillets complete all as specified and directed.
Supply and fixed 6 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to walls surface etc complete all as specified and directed.
Supply and fixed 4 mm thick plywood , graded BWR, type BB fixed with nails to timber frame work fixed to ceiling surface etc complete all as specified and directed.
Material & labour for 2nd class hard wood plain fillets, square, rectangular or triangular in section, wrought, secured with nails having sectional area not exc. 3 sqcm complete all as specified and directed
Dismantling Timber scantling with framed work in fillets, rails, posts, rafters, purlins, etc. under 40 sq cm in section , in any position all as specified and directed.
M& L for cleansawn Second class hard-wood scantlings with framed work with complete all as specified and directed
Material and labour for new plywood and wood based material surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Material and labour for preparation of old steel surfaces of any description not otherwise described over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width tuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of lain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable colour PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Non Asbestos fibre cement bldg boards fixed or laid/inserted to GI/Aluminium framework with screws designer type as in false ceiling with & incl aluminium snap grid of size and fixed with hangers 6mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3 mm size 60mm long and expansion hold fasteners 12.5mm dia ,40mm long complete all as specified with allconnected accessories, fittings and fixtures complete all as specified and directed.
S & F 30mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauze etc but divided into squares, edges of framing plain, chamfered or rounded,mitred and rebated sash bars, any numbers for ventilators etc are provided with stiles and rails as specified in SSR Part-1, section 8 clause 8.24(b) and directed.
S&F PVC water storage tanks of 1000 ltrs capacity rotational moulded (multi layered cylindrical vertical with closed top) hoisted and fixed in position all as specified
S&F ball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of 20mm dia all as specified (Make:Jindal/Leader/Scico).
S&F 25mm outer dia PP-R Gate valves (brass insert) as per requirement of the site
S&F vitreous china wash hand basin white flat back of size 550mmx400 mm including CI brackets and waste pipe complete all as specified and directed (Make: Hindware/Parry).
S&F 32mm dia waste coupling of PTMT (half or full threaded). (Minimum weight 32mm- 45gms/40mm-60 gms).
S & F fancy typy chromium plated 15mm dia pillar taps fancy type copper alloy with capstan heads, screwed down high pressure, with or without lettered "hot or cold" with long screwed shanks and fly nuts, screwed for iron pipe and fixed.
Supply and fix chromium plated brass Bib taps,cast copper alloy with crutch or butterfly handle, screwed down for PP-R pipe for 15mm bore tubing complete all as specified and directed by Eng-in-charge.
S&F Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for for PP-R pipe for 15mm bore tubing complete all as specified and directed by Eng-in-charge.
S&F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified.
S & F 10 litres PVC, valve less, Syphonic action type, Flushing cistern low level, white with inlet ball valve float chain and pull and brackets with flush pipe complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified
S&F Soap dish, vitreous China white, approximate size 160x 160x90mm complete all as specified and directed.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms).
S&F PVC (SWR) pipes 110mm dia single sockted in any length with rubber ring joints laid in trenches or floors.
M&L cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) to bed of drain pipes including packing under and haunching against the sides of pipes, after they are laid and tested for 110 mm bore pipe complete all as specified and directed
S&F PVC (SWR) bends any radius with access door, 110mm dia.
S&F PVC (SWR) bends any radius with access door, 75mm dia.
S&F PVC (SWR) pipes 75mm dia single sockted in any length with rubber ring joints laid in trenches or floors..
S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement.
S&F in 20mm outer dia 3-layer PP-R P polypropyelene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded random fittings fixed complete to walls, ceilings or in floors etc.
S&F in 16mm outer dia 3-layer PP-R P o l y p r o p y l e n e random polymer) oncealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded random fittings fixed complete to walls, ceilings or in floors etc.
S&F PVC connection of 15 mm size with PTMT nuts of length 450 mm as specified .
Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (HRFR), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (HRFR)single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
All as per item No. 112 here in before One 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size
All as per item No. 112 here in before but for one 3 pin socket outlet 5 Amps three pin controlled by one switch on independent board complete all as specified directed.
All as per item No. 112 here in before but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with PVC boxes complete all as specified.
S&F Socket outlet 2 in 1, 3 pin, 5 amp flush type
S&F Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type
Supply & fixing switch piano flush type (ISI marked), single pole, one way 15 Amp, 240 Volts complete all as specified & directed.
Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed.
Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed.
Supply and fixing lamp holder, insuleted body with pack plate suitable batten fitting on wall duly grouted/fixed in solid block wall or on wooden board complete all as specified and directed.
S&F LED lamp 9 Watt, CDL, B-22 cap, (Pin type), 230W, PF not less tha 0.85 (min). Make- Havells/Crompton/Syska
S&F LED lamp 10 Watt, CDL, B-22 cap, (Pin type), 230W, PF not less tha 0.85 (min). Make- Havells/Crompton/Syska
S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed.
Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed.
S&F regel batten for LED Tube universal batten for G 13 T8 lamps including making electric connection from Ceiling Rose to tube light fitting including photon ultra plus LED Tubelight 20W (single side connection) Ultra bright LED Polycarbonate Tubelight with 10% THD with very high efficiency suited for installation in existing T8 Tubelight with G13 lamp holders to give glare free light with integrated electronic driver incl taking down old unsv one complete all as directed by Engr in Charge.
S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbersclmaps, all fixing arrangements such as fastners, bilts, nuts washers etc all as specified and directed.
S & F of GI brackets for fixing LED building security light fitting fabricated out of GI tubing 32 mm dia, light grade, 0.9 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 30 x 4 mm -02 Nos complete for fixing on wall including all fixing arrangements such as fastners, bilts, nuts, bolts washers etc including making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge
Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 08 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board.
Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 04 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board.
S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 V complete all as specified and directed.
S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 V complete all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
S&F of 1100 Volts grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conductor one twin core cable flat or circular of size 16 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size 10 Smm 2 core with complete all as specified and directed.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated stranded aluminium conductor one twin core cable flat or circular of size 10 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of following sizes.
M&L fo replacement of TPN Kit kat main switch unit of 415 Volt 50 Hz three phase of capacity 100 Amp including MS box with backelite fuse & fuse carrier fittings , operating insulated handle, top cover necessary locking arrangemnts etc as per IS/IEC 60947 1&3 including necessary wall mounting fitting as directed including taking down the existing all as specified and directed. Make : INDOASIAN / L&T/Havells
Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc)
Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC.
Taking down sub main wiring of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC.
M/S R N ENTERPRISES
M/S TENZING ENTERPRISES
M/S SM ANSARI
M/S N D ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .