CWE AF NAGPUR
HQ CWE AF NAGPUR VAYUSENA NAGAR, NAGPUR 440007 MILITARY ENGINEER SERVICES
PROVISION OF FIRE ALARM AND DETECTION SYSTEM ASD29 ASD30 FTSD HANGAR AT 11 BRD UNDER GE (AF) OJHAR
2026_MES_798648_1
80799/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF OJHAR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE AF OJHAR
₹2.2 L
Yes
13 Nov 2026
13 Nov 2026
12 Dec 2026
13 Nov 2026
10 Dec 2026
4 Dec 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation Testing & Commissioning of microprocessor based Networkable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity from 2 loops to 8 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer. Approved by LPCB. Model- Latitude 2LKS Make: Hochiki or equilant from Bosch/ Seimens | 9 | EACH | - | - |
| 2 | Supply, Installation Testing & Commssioning of Analogue Addressable Multi- Sensor which is fully compatible with Analogue Addressable Protocol,having removable high performance chamber with Twin fire LED's allow 360 degree veiwing, User selectable sensitivity modes 1% to 4.5% obs/m, Incorporate Optical and dual Heat elements, lock mechanism ( sensor to base), Electronically addressed, Pulsing/non-pulsing controlled from panel. complete all as specified and directed by engir in charge. Approved by LPCB & VdS. Makes: (Hochiki/LST/Bosch) | 401 | EACH | - | - |
| 3 | Supply, Installation Testing & Commissioning of Intrinsically Safe Conventional Rate of Rise Heat detector features, Twin LEDs allow 360 degree viewing, Electronics free mounting base, remote indicator output, ATEX classification II 1G EEx ia IIC T5 Tamb = 55 degree, Suitable for installation in areas at Category 1 (inc all lower categories). ATEX Approved Make: Hochiki/Bosch/Seimens | 14 | EACH | - | - |
| 4 | Supply, Installation Testing & Commissioning of Analogue Addressable Intrinsically Safe Dual Zone Monitor with integral Short Circuit Isolator which allow Supports two independent zones of 30 conventional detectors each (total 60 conventional detectors). Both zones fully monitored for short/open circuit, Addressing via DIL switches, Approved by LPCB Make: Hochiki/ Bosch/Seimens | 8 | EACH | - | - |
| 5 | Supply installation Testing and Commissioning of Triple IR Sensor Flame Detector-FLD-3300-FLP approved by CIMFR and PESO | 9 | EACH | - | - |
| 6 | Supply, Installation Testing & Commissioning of Analogue Addressable Manual Call Point with Integral Short Circuit Isolator, Analogue Addressable Protocol having,Bi-coloured status LED (red for alarm, amber for (short-circuit), Non-frangible element fitted as standard (conforms to EN54), pulsing/non-pulsing can selectable via panel, Electronically addressed, complete all as specified and directed by engir in charge. Approved by LPCB. Makes: (Hochiki/LST/Bosch) | 50 | EACH | - | - |
| 7 | Supply, Installation, testing and commissioning of Intelligent loop powered wall Sounder with Flasher Beacon which provide a range of tones and volumes with a maximum output of up to 102dB(A) (±2dB(A)) with low current consumption, 51 user selectable tones (all tones EN54-3 compatible). complete all as specified and directed by engir in charge. Approved by LPCB & VdS. Makes: (Hochiki/EMS/Gamewell) | 45 | EACH | - | - |
| 8 | Supply, Installation, Testing and commissioning base Fault Isolator fully monitored for short/Open circuit compatible with Analogue Addressable Protocol,Electronically addressed, approved by LPCB,unit incorparates an amber LED to show when it is islating a section of a Loop complete all as specified and directed by engir in charge. Makes: (Hochiki/EMS/Gamewell) | 15 | EACH | - | - |
| 9 | Supply , Installation Testing & Commissioning of Analogue Addressable Dual Relay Controller with integral Short Circuit Isolator which allow 2 independently controlled change over relays,Relay Contact Rated at 30 V DC at 1 Amp. having auxiliary monitored input, followed by Analogue Addressable Protocol, Addressing via DIL switches, Approved by LPCB. Makes: (Hochiki/EMS/Gamewell) | 18 | EACH | - | - |
| 10 | Supply, Installation, Testing and Commissioning of Optical Beam Smoke Detector. The detector shall have 5 - 100 m range, Automatic compensation, Maximum coverage 1500m2, Automatic Signal strength adjustment, Emitter unit can be powered directly from zone ( or loop), Features a Latching or Non- Latching fault relay, Full line continuity options, Approved by LPCB & VdS. Model- SPC-ET Make: Hochiki/Bosch/Seimens | 8 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.47 MB
TENDERPAGES80799.pdf
Tender Documents • 0.76 MB
PS80799.pdf
Tender Documents • 0.33 MB
BOQ_895946.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .