Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC RAM SHIV COLONY GALI NO 2 NAIKA CHATNAG ROAD JHUNSI PRAYAGRAJ UP 211019 | PRAYAGRAJ | UTTAR PRADESH | 211019 | L1 | Accepted-AOC AOC | |
| 2 | L2₹5.3 L+₹46,940 (9.81%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹5.5 L+₹67,540 (14.1%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest | |
| 4 | L4₹6.9 L+₹2.1 L (43.8%)Rejected-AOC SHOP NO 82 6 TRANSPORT NAGAR NARWAL JAMMU 180004 | JAMMU | JAMMU | J K | 180004 | L4 | Rejected-AOC Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹14,000
Closing Date
31 Jul 2021, 6:00 pmClosed
AGE(I)CIF(U)
AGE(I)CIF(U) Reasi
REPAIR TO SECURITY LIGHTS, VOLTAGE STABILIZERS AND DG SETS AT SILA GRN UNDER AGE(I) CIF(U)
2021_MES_453699_1
AGE(I)CIF(U)-20/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I)CIF(U)
As per NIT and Tender Pages
8 documents required · 8 mandatory
₹500
AGE(I)CIF(U)
₹14,000
Yes
10 Sept 2021
23 Jun 2021
2 Aug 2021
23 Jun 2021
31 Jul 2021
16 Jul 2021
Amount
M&L for maintenance and servicing of DG Set complete of capacity 82.5 KVA, Make: Kirloskar installed at Chenab pump house in Sila Garrison including draining out of diesel from tank, cleaning the tank thoroughly and refilling the drained out diesel, draining out engine oil from the sump, flushing the sump thoroughly and replacing the fuel filter elements, oil filter element and cleaning of air filter all as required and filling the starter batteries with elecrtrolite to maintain the required specific gravity, applying the petrolium jelly in battery terminal poles, replacing the diesel tank level tube, cleaning the entire DG Set, checking of voltage, Hz, Amps and adjusting fuel/oil all as required, overhauling of radiator assembly, tightening the all bolts and nuts with replacement of warnout hose pipes, overhauling of fuel Injection pump & Injectors by replacing the elements, D - Valves, O- rings, nozzles, bearing and gaskets and reassembling the new parts and calibrating in MICO test bench as per manufaturer specification including testing and comissioning the DG set in working condition, complete all as specified and directed by Engineer-in-Charge. Note: (i) Transportation for DG set required to repair at workshop shall borne by contractor. (ii) All replacement parts shall confirming to OEM/ISI makes as approved by AGE(I).
All as per item No. 1 here in before but for DG set 82.5KVA, Make: Mahindra & Mahindra installed at Peer Baba Pump House at Sila Garrison Reasi
All as per item No. 1 here in before but for DG set 62.5KVA, Make: Cumins installed at 27 ADU Pump house at Sila Garrison Reasi
All as per item No.1 but 40KVA, Make: Cummins, installed at MRS Sila Garrison Reasi
Supplying and fixing in replacement of sealed maintenance free lead acid battery 12 volt, 150 AH for DG sets installed at Sila Garrison Reasi. Make - Exide Genplus or AMCO Insta Power or Amaron Quanta as approved by AGE(I)
Supply and filling engine oil SAE 20w - 40 for DG sets at Sila Garrison Reasi.
Supply and filling radiator coolant for DG sets at Sila Garrison Reasi.
S& F in replacement of old unserviceable set of V-Belts for DG Sets 30 KVA to 82.5 KVA installed at Sila Garrison Reasi.
S& F in replacement of old unserviceable air cleaner element of DG set 40 KVA-82.5KVA at Sila garrison Reasi.
Supply and fix in replacement of old unserviceable high pressure copper tubes of required size from FIP to injectors for DG set 30- 40 KVA installed at Sila Garrison Reasi.
Supply and fix in replacement self starter assembly 12 volt suitable for 30 to 40 KVA DG set installed at Sila Garrison Reasi Make: Kirloskar/Cummins.
All as per item No 11 here in before but for DG Set 62.5 KVA installed at Sila Garrison Reasi. Make: Kirloskar/Cummins.
Disconnecting the unserviceable burnt out self starter from DG set assembly,cleaning the slots,Rewinding with super enamelled copper winding wire of of suitable gauge,varnishing,drying and insulating with insulating materials and refixing the same and testing complete all as required and directed for DG sets 30 KVA to 82.5 KVA. Note: (i) Transportation for repairing at workshop shall borne by contractor. (ii) All replacement parts shall confirming to OEM/ISI makes as approved by AGE(I).
Disconnect,removing and strip opening the unserviceceable burnt out winding of the stator of alternator assembly of DG Set and rewinding complete with super enamelled copper winding wire not less than the existing size including insulating material,drying,varnishing etc including transportation from site to contractor's workshop and back to the site and refixing with engine all as required and directed for DG Sets 30 KVA to 40 KVA. Note: (i) Transportation for repairing at workshop shall borne by contractor. (ii) All replacement parts shall confirming to OEM/ISI makes as approved by AGE(I).
All as per item No 14 here in before but of capacity 62.5 KVA to 82.5 KVA .
Supply and fixing in replacement automatic voltage regulator (AVR) electronic suitable for DG set 30 KVA to 40 KVA as per existing specifications complete all as specified and directed.
Supply and fixing in replacement automatic voltage regulator (AVR) electronic suitable for DG set 62.5 KVA to 85.5 KVA as per existing specifications complete all as specified and directed.
Replacement of door hinges cast alloy of suitable size for silent DG set doors of capacity 30 KVA to 82.5 KVA as per existing specifications complete all as specified and directed.
Supply and fixing in replacement of door lock cast aluminium of suitable size for silent DG set doors of capacity 30 KVA to 82.5 KVA as per existing specifications complete all as specified and directed.
supply and fixing in replacement control assembly (digital display) of DG set Panel of capacity 30 KVA to 82.5 KVA of ISI/OEM make complete with necessary electric connections including checking of all electric connections and make functional al as directed.
Supply and fixing in replacement with new energy efficient inverter security light 45 watt with RTC having the following technical specifications including taking down old unserviceable security lights complete all as specified and directed by Engineer-in-Charge:- Housing Material: Aluminum PDC, Top maintainable Front Cover: Clear toughened glass Lens: Suitable high efficient secondary lens LED: LM80 certified LED LED Lumen Maintenance: 50,000 hours @ L70 Control Gear: Isolated, Electronic, CC driver RTC enabled Internal Wiring: Insulated Cu wire Hardware: SS & MS Zinc plated and passivated Ingress Protection: IP66 Impact Resistance: IK05 Operating Voltage: 140V~270V Operating Temperature: -10ᵒC~ 50ᵒC Emergency Light Output: Initial Lumen at Battery mode will reduce to 15-20% Emergency time: 1.5-2 hours Max. (Battery Back-up with Li-ion Battery), mounting on 50mm GI medium grade bracket. Make : Halonix Cat Part No :- HLSLD-ML04-45-CWL-INV-RTC-R or equivalent i Havells/Crompton Greaves/C&S/Philips Note:- Contractor will be responsible for replacement of defective lights during light manufacturing company's warranrty period even if it exceeds the defect liability period.
Disconnecting electric connections of servo voltage stabilizers, capacity 50 to 100 KVA, draining out the unserviceable transformer oil, cleaning of sludge from oil tank and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading by mechenical means, complete all as specified and as directed by Engineer-In-Charge. Note: (i) Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items. (ii) All replacement parts shall confirming to OEM/ISI makes as approved by AGE(I).
Replacement of old unserviceable Printed Circuit Board (PCB) with new Printed Circuit Board (PCB) of voltage stabilizer as per existing make and type, capacity 100 KVA, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable carbon bushes with new carbon bushes of voltage stabilizer as per existing make and type, capacity 50-100 KVA, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable servo motor with new servo motor of voltage stabilizer as per existing make and type, capacity 50- 100 KVA, complete all as specified and as directed.
S &F in replacement digital voltmeter, range 0-500 Volts, size 96mmx96mm, flush type, complete suitable for voltage stabilizers all as specified and as directed by Engineer-In-Charge.
S&F in replacement digital ammeter, range 0-100 Amps, size 96mmx96mm, square shape, complete suitable for voltage stabilizers all as specified and as directed.
Replacement of old unserviceable dimmer gear set with new cast iron dimmer gear set, for automatic voltage corrections, make, type and design as per site requirement, suitable for voltage stabilizer capacity 50 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable servo dimmer booster coil with new servo dimmer booster coil, for automatic voltage corrections, make, type and design as per site requirement, suitable for voltage stabilizer capacity 50 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old unserviceable control wiring with new control wiring using suitable gauge copper conductor as per existing winding and specifications suitable for stabilizer of capacity 50 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge.
Replacement of old damaged/ unserviceable Control Transformer 230V with new Control Transformer, heavy duty suitable for servo stabilizer of 50 KVA to 100 KVA capacity, complete all as specified and as directed.
M&L for topping up of deficient oil level of Servo voltage stabilisers with filtered and dehydrated transformer oil (conforming to IS: 335) and to withstand dielectric strength upto 30 KV or above (when tested with 2.5 mm gap electrode) complete. Make - Trans oil/ Savita / Power link / Powe roil
Note:- Deduction for Schedule of credit (Sch 'A' Part-II) to be made of Rs. 52,990.00 from the total quoted amount of BOQ while accepting the bid. Details of schedule of credit is given in tender documents.
MAMTA ENTERPRISES
Kalsi Engineers and contractors
Balbir Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .