Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance AT KHARJARBARI DIST GIRIDIH | GIRIDIH | GIRIDIH | JHARKHAND | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance BACHRA RAY KHALARI RANCHI JHARKHAND 829210 | RAY | RANCHI | JHARKHAND | 829210 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹5.3 L
EMD Value
₹6,630
Closing Date
2 Dec 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer(EnM), Rajhara Area
Rajhara Area Chandwa
3.3 KV OHL modification work and providing safety provisions like earthing, GOAB Switch, lighting arrester and cradling from Main substation to new pumping site and installation of 100 KVA Transformer on TP of Rajhara Area
2022_CCL_262282_1
GM(RA)/CHANDWA/EnM/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Rajhara OCP
Please refer Tender documents.
5 documents required · 5 mandatory
₹6,630
3 Dec 2022
15 Nov 2022
3 Dec 2022
16 Nov 2022
2 Dec 2022
16 Nov 2022
16 Nov 2022 - 22 Nov 2022
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required. For making fuse unit at main sub station
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supplying and erection of stay set complete (galvanised) with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, bow tightener, 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supplying and erection of 100 mm x 80 mm pin insulator with GI bolt , nuts and straps etc. as required
Erection of ACSR conductor of 7/2.11mm to 7/3.00 mm dia and including binding etc. as required
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
wiremen for installation of 100KVA transformer
8 SWG GI wire
Erection of GI wire no. 8 SWG including binding etc. as required
Dismantling of pole / street light standard / strut embedded in cement concrete foundation etc. as required
Dismantling of over head lines comprising of copper / aluminium over head conductor, GI wire , cross arms , insulators etc. as required
Erection of ACSR conductor of 7/2.11mm to 7/3.00 mm dia and including binding etc. as required
Erection of hexagonal type guard as required.
Erection of ACSR conductor of 7/2.11mm to 7/3.00 mm dia and including binding etc. as required
Supplying, installation, testing and commissioning of Passive Infrared (PIR) technology based occupancy sensor with day light dimming (lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance, regulating programmable type, suitable for connected load upto 10 Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying of 800A, 3.3KV grade Horizontal type GOAB Switch
Total impact of GST for the purpose of CTC
SHREE RAM ELECTRICALS
finance_271255.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .