Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.4 LAccepted-AOC BATHAIPAR RAWATPAR DEORIA DEORIA UTTAR PRADESH 274001 UDYAM UP 21 0039531 | DEORIA | UTTAR PRADESH | 274001 | ₹49.4 L Quoted ₹50.5 L | L1 | Accepted-AOC L1 |
| 2 | L2₹57.2 L+₹6.8 L (13.4%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | ₹57.2 L+₹6.8 L (13.4%) | L2 | Rejected-Finance OTHER THAN L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not recommended as the contractors are not submitted the required category for the tender i.e c (vi) and also not submitted documents of similar nature of work experience |
| 4 | Rejected-Technical HOUSE NO 41 WARD NO 09 ARYA SAMAJ GALI UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | - | - | Rejected-Technical Not recommended as the contractors are not submitted the required category for the tender i.e c (vi) and also not submitted documents of similar nature of work experience |
| Sl No | Description | Qty | Unit | slathia construction works L2 | ATUL TRADING CO L1 |
|---|---|---|---|---|---|
| 1.00 | Supply, fixing and testing of conventional manual call point 24V resettable type, each MCP installed on the loop shall have a unique address, set at the commissioning stage by means of a seven-segment DIL switch. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion, complete all as specified and directed by the Engineer-in-Charge. | 40 | Each | 600 ₹24,000 | 550 ₹22,000 Lowest |
| 2.00 | Repairing and testing of existing unserviceable and manual call point including opening, soldering of circuits, cleaning, replacement of glass, testing and painting, complete all as specified and directed by Engr-in-Charge. | 120 | Each | 110 ₹13,200 | 100 ₹12,000 Lowest |
| 3.00 | Supply fixing and testing loop powered sounder strobe 24V. Dual tone hooter shall be of electronic type and shall give discontinuous/ intermittent audible alaram. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion and, complete all as specified and directed by the Engineer-in-Charge. | 40 | Each | 600 ₹24,000 Lowest | 600 ₹24,000 Lowest |
| 4.00 | Dismantling the existing loop sounder by disconnecting device by movable ladder, dismantling cap & sensor board, cleaning the parts using CRC solution and check the control wiring circuit the PCB board , communication panel, device controlled by a programme, device sound & fire red flash light indication while fire activate and re addressing & re installation work, complete all as specified and directed by the Engineer-in-Charge. | 120 | Each Job | 150 ₹18,000 | 100 ₹12,000 Lowest |
| 5.00 | Programming the main fire alarm panel, detecting the device activating the sounder according to the device, checking the communication between the all the device, fire alarm and main panel using ladder, making main fire alarm to normal display without any fault, complete all as specified and directed by the Engineer-in-Charge. | 32 | Each Job | 750 ₹24,000 | 300 ₹9,600 Lowest |
| 6.00 | Material & labour wiring for circuit / submain wiring along with earth wire with the cable FR LS, PVC insulated, un sheathed, copper conductor, multistranded, 1100 volts grade single core cables drawn through and including ERW steel conduit and conduit accessories surface / concealed in walls all as specified of size 2 x 1.5 Sq mm + 1 x 1.0 Sq mm for Smoke / fire detectors, complete all as specified and directed by the Engineer-in-Charge. | 200 | RM | 100 ₹20,000 Lowest | 100 ₹20,000 Lowest |
| 7.00 | Supply,Installation and testing of fire alaram panel 8 Zone conventional type made out of CRCA sheet with powder coated finish of IP50 red colour suitable for operate on primary power 120-220VAC and stand by power 24 V DC , wall/celing mounted, complete all as specified and directed by the Engineer-in-Charge. | 12 | Each | 15,000 ₹1,80,000 | 10,000 ₹1,20,000 Lowest |
| 8.00 | M&L for disconnecting/ removal of corroded MS sheet 3mm thick from fire fighting boxes and supply and fabricate 3mm thick CRCA sheet including necessary door hinges, door knobs, door locks, aldrops, over drops, door beading, rubber washers angles iron channel, clamps etc including applying 2 coats of synthetic enamel PO red paint over a coat of zinc chrome primer and fixing of 4mm thick transparent glass on the door as per existing, complete all as specified and directed by the Engineer-in-Charge.
Note:(a).The rate quoted includes connected welding works/ gas cutting works along with all hardware/ miscellaneous items.
(b) Transparent glass sheet and lock & Key arrangement system will be measured separately. | 110 | Each Job | 500 ₹55,000 Lowest | 500 ₹55,000 Lowest |
| 9.00 | Supply and fixing transparent plain glass 4mm to 5mm thick as per site requirement and existing specification, complete all as specified and directed by the Engineer-in-Charge. | 150 | Sqm | 600 ₹90,000 Lowest | 600 ₹90,000 Lowest |
| 10.00 | Supply and fix lock and key arrangement for fire hydrant chamber as per existing with two nos of keys for each lock, complete all as specified and directed by the Engineer-in-Charge. | 150 | Nos | 2,500 ₹3,75,000 | 300 ₹45,000 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
29 Jul 2025, 6:00 pmClosed
GE (Utilities) Udhampur
GE (Utilities) Udhampur, PO-GARHI, PIN-182121
Repair/Maintenance of fire detection, Alarm and fire fighting system under GE (Utilities) Udhampur
2025_MES_716816_1
GE/U-43/2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (Utilities) Udhampur
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Utilities) Udhampur
₹98,000
2 Sept 2025
26 Jun 2025
31 Jul 2025
26 Jun 2025
29 Jul 2025
10 Jul 2025
Amount
Supply, fixing and testing of conventional manual call point 24V resettable type, each MCP installed on the loop shall have a unique address, set at the commissioning stage by means of a seven-segment DIL switch. The elapsed time between activation of the MCP and initiation of the sounders in an alarm condition via command from the fire alarm control panel shall not exceed three seconds complete in all respect as specified or indicated including testing on completion, complete all as specified and directed by the Engineer-in-Charge.
Repairing and testing of existing unserviceable and manual call point including opening, soldering of circuits, cleaning, replacement of glass, testing and painting, complete all as specified and directed by Engr-in-Charge.
Supply fixing and testing loop powered sounder strobe 24V. Dual tone hooter shall be of electronic type and shall give discontinuous/ intermittent audible alaram. The line matching transformer shall be provided complete in all respect as specified or indicated including testing on completion and, complete all as specified and directed by the Engineer-in-Charge.
Dismantling the existing loop sounder by disconnecting device by movable ladder, dismantling cap & sensor board, cleaning the parts using CRC solution and check the control wiring circuit the PCB board , communication panel, device controlled by a programme, device sound & fire red flash light indication while fire activate and re addressing & re installation work, complete all as specified and directed by the Engineer-in-Charge.
Programming the main fire alarm panel, detecting the device activating the sounder according to the device, checking the communication between the all the device, fire alarm and main panel using ladder, making main fire alarm to normal display without any fault, complete all as specified and directed by the Engineer-in-Charge.
Material & labour wiring for circuit / submain wiring along with earth wire with the cable FR LS, PVC insulated, un sheathed, copper conductor, multistranded, 1100 volts grade single core cables drawn through and including ERW steel conduit and conduit accessories surface / concealed in walls all as specified of size 2 x 1.5 Sq mm + 1 x 1.0 Sq mm for Smoke / fire detectors, complete all as specified and directed by the Engineer-in-Charge.
Supply,Installation and testing of fire alaram panel 8 Zone conventional type made out of CRCA sheet with powder coated finish of IP50 red colour suitable for operate on primary power 120-220VAC and stand by power 24 V DC , wall/celing mounted, complete all as specified and directed by the Engineer-in-Charge.
M&L for disconnecting/ removal of corroded MS sheet 3mm thick from fire fighting boxes and supply and fabricate 3mm thick CRCA sheet including necessary door hinges, door knobs, door locks, aldrops, over drops, door beading, rubber washers angles iron channel, clamps etc including applying 2 coats of synthetic enamel PO red paint over a coat of zinc chrome primer and fixing of 4mm thick transparent glass on the door as per existing, complete all as specified and directed by the Engineer-in-Charge. Note:(a).The rate quoted includes connected welding works/ gas cutting works along with all hardware/ miscellaneous items. (b) Transparent glass sheet and lock & Key arrangement system will be measured separately.
Supply and fixing transparent plain glass 4mm to 5mm thick as per site requirement and existing specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix lock and key arrangement for fire hydrant chamber as per existing with two nos of keys for each lock, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing rubber hose pipe 30 mtr,20mm inner dia, thermo plastic, working pressure 10kg/sqcm confirming to IS-12585 braided for high pressure, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing fix gun metal fire hose reel nozzle suitable for 20mm bore hose pipe with handle as per existing, complete all as specified and directed by the Engineer-in-Charge.
Repair of hose pipe reel drum suitable for 30 mtrs, 20 mm dia rubber hose pipe working pressure 10 Kg/Sqcm, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing ISI marked RRL (Rainforced Rubber Lined) fire hose pipe 15 meter long with male and femail couping gun metal 63mm instantaneous inlet with 15mm bore nozzle short, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing fix gun metal fire hose reel nozzle suitable for 63mm bore hose pipe with as per existing, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing double headed outlet hydrant valve 100mm flanged end having 65mm outlet with lock pin wheel including nut, bolt, washer, gasket, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing single headed outlet hydrant valve 100mm flanged end having 65mm outlet with lock pin wheel including nut, bolt, washer, gasket , complete all as specified and directed by the Engineer-in-Charge.
Repair single/double headed outlet hydrant valve 100mm having 65mm outlet with lock pin wheel, complete all as specified and directed by the Engineer-in-Charge.
Checking of Pre charged Air vessel including servicing, greasing, overhauling, tightening of nut bolts and other spares as required shall be inclusive in the quoted rate. Maintain and ensure for proper working condition and ready for operation and including, complete all as specified and directed by the Engineer-in-Charge.
Supply and fix pressure switch universal type as per existing make and specifications, complete all as specified and directed by the Engineer-in-Charge.
Providing & fixing 100mm dia bourden type, stainless steel dial type pressure Gauge (0 - 14 Kg) range, 4" BSP bottom entry on pump delivery line complete with ball valve (Glycerin based), complete all as specified and directed by the Engineer-in-Charge.
Supplying and fixing air vessel of continuous welded construction fixed at riser top made of 250 mm dia, 8 mm thick MS sheet, 1000 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun Metal wheel valve, with required accessories, pressure gauge and painting with two coats of red oxide and two coat of post office red enamel paint as required, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing hose reel drum with handle suitable for hold 30 mtr hose pipe , complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing ISI marked (IS : 15683) Portable Fire Extinguisher, ABC type, finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of capacity 6.0 Kg. ABC type Fire Extinguisher, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Carbon-di-oxide fire extinguishers (IS-15222) consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge 4.5 Kg. Light weight squeeze grip CO2 type Fire Extinguisher, complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing ISI marked (IS : 15683) Portable Fire Extinguisher, AFFF type, finished externally with red enamel paint, complete in all respects including initial fill and wall suspension of capacity 9.0 Kg. type Fire Extinguisher , complete all as specified and directed by the Engineer-in-Charge.
Refilling of Portable Fire Exitnguisher, ABC type,finished externally with red enamel paint, complete in all respects including wall suspension arrangement of capacity 6.0 Kg. ABC type Fire Extinguisher, complete all as specified and directed by the Engineer-in-Charge.
Refilling Carbon-di-oxide fire extinguishers finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete 10Kg. Light weight squeeze grip CO2 type Fire Extinguisher.
Supply and fixing battery 7AH, 12 Volts maintenance free as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Material and labour for cutting existing MS pipe of bore 80mm to 150mm size and jointing with proper welding and testing of all fittings complete with all welding/threading works and jointing material laid in trenches/ on surface / slopes/ pillars/ culverts includind necessary earth work etc, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in replacement of cast iron sluice valve of size 150 mm (PN 1.6) (ISI Marked) with iron wheel head, both end flanged, stainless steel spindle, non rising type complete with neoprene rubber gasket, nuts, bolts and washers, necessary welding wk etc.including taking down old unsv complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of cast iron non return valve, conforming to IS-5312, suitable for 150 mm bore pipe, heavy duty ,both end flanged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket with nuts, bolts and washers, welding wk including taking down old unsv complete all as specified and directed by Engr-in-Charge.
Material and labour of cross arms ,bracings,supports,clamp and back plate fabicated from structural steel sections,including nut and bolts, washers welding bend or cold or hot,drilling holes for bolt in any shape or size indicated or direcected and inclusive of one primer coat,one under coat and one finishing coat all complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing and testing ERW MS pipe class 'B' pipe 150 mm bore having wall thickness 6mm with permissible tolerance + 10%, pipe shall be confirming to IS-3589, IS marked and steel grade of Fe-410 along with joints (As per site requirements) and taking down of old unserviciable pipe. laid in trenches/along road/on surfaces/slopes/pillars/culverts/causeways etc. complete all as specified and directed by Engr-in-Charge. Note:- (i) Jointing of pipe line will be done through flanging including nut bolts, washers, flanges etc or circular welding as per site requirment and directed by Engr-in-Charge. (ii) Excavation and earth work will be measured and paid separately.
Description all as per serial item No 34.00 here-in-before but of size 80 mm bore.
Supply and fixing in replacement of butterfly valve of size 150 mm (PN 1.6) (ISI Marked) gtype complete with neoprene rubber gasket, nuts, bolts and washers, necessary welding wk etc.including taking down old unsv complete all as specified and directed by Engr-in-Charge.
Repair to old sluice valve/butter fly valve of sizes 100 to 150mm for check nut, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of sluice valve & spindle including fixing & testing , complete all as specified and directed by the Engineer-in-Charge.
Repair to old non return valve of sizes 100 to 150mm for check nut, refacing, regrinding & refixing at its original location including cleaning, repacking stuffing box of non return valve including fixing & testing , complete all as specified and directed by the Engineer-in-Charge.
Disconnecting electric connection of motor upto 60 HP removing the unserviciable motor from existing place by unscrewing the foundation bolts and nuts decoupling from the pump, setting aside and transporting to workshop for repairs including dismantling the motor,cutting/taking out burnt winding of stator, rotor, cleaning the slots, transporting back after repair/winding & re-assembling the same, complete all as specified and directed by the Engineer-in-Charge. Note: (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of serviceable motor duly functional and testing complete at its existing location/position complete all as specified and directed.
Removing the burnt out winding from the rotor and stator, cleaning the slots, providing high quality of class'B' paper insulation inside the slots, rewinding the motor of capacity 10 HP with super enamel copper wire of same size and guage as per existing rapping up with high quality cotton tape and varnising with super quality oil including drying upto desired temperature and desired time, complete all as specified and directed by the Engineer-in-Charge. Note:- Cost of labour for winding deemed to be included in the rate quoted. Make : Atlas/Devi Dayal or equivalent make approved by GE.
Supply and fixing self lubricated asbestos non metallic and non graphite gland packing of sizes 8 to 12 mm complete all as specified and directed by Engr-in-Charge.
Material and labour for scrapping of existing paint on fire fighting Pipe lines, fittings, motors, pumps, cabinet boxes, valve chamber covers, fire brigades and other miscellaneous items associated to the complete fire fighting system in buildings up to (G+6 floors) and applying two coats red colour synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Material and labour for cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in foundation, filling and mass concrete for providing support for Base frame with MS bolts placed in concrete finishing even and fair without using extra cement including demolition complete all as specified and directed by Engr-in-Charge. Note: Location and size of bolts should match as per the previous concrete supporting blocks.
Supply and laying in replacement of XLPE insulated, armored heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 16 sq. mm 4 core power cable fixing on walls with saddles complete all as specified and directed by Engr-in-Charge.
Supply and laying in replacement of XLPE insulated, armored heavy duty electric cable with aluminium conductor, 1100volts grade, cross-sectional area 10 sq. mm 3 core power cable fixing on walls with saddles complete all as specified and directed by Engr-in-Charge
Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity upto 15 HP , complete all as specified and directed by the Engineer-in-Charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A.
Supply only parts in repair for single/multistage pumps of capacity upto 15 HP as per manufacturer's composition of existing make of pump as below all as specified and directed by Engr-in-Charge. Make-Kirloskar/CG/Mather platt.
Pump impeller made out of stainless steel or as per existing specification. Make : Kirloskar/Wilo Mather Platt or equivalent make as approved be GE.
Pump shaft stainless steel shaft complete with check nut and keys.
Tyre coupling/star coupling or as per existing at site.
Gland cup.
Shaft sleeves.
Welding remelting and turning finishing cutting of key ways in respect of pump shaft.
Bearing housing.
Pump Casing CI cover suitable for 10HP of different makes
Decoupling, disconnecting suction line and discharge line taking down from foundation, dismounting from base channels strip opening all parts, derusting, cleaning, overhualing comprising of repairs/replacement of unserviceable parts of pump sets and taking to workshop (if reqd) for repairs. Reassembling of pump set mounting and fixing on base channel, recoupling of suction & discharge line realignment commissioning and testing in respect of centrifugal/multistage pump of capacity upto 20 HP to 60 HP, complete all as specified and directed by the Engineer-in-Charge. Note :(i) Loading/unloading & transportation charges shall be deemed included in the quoted rates. (ii) S&F of parts shall be measured and paid separately under respective item of sch A.
Supply only parts in repair for single/multistage pumps of capacity 20 HP to 60 HP as per manufacturer's composition of existing make of pump as below , complete all as specified and directed by the Engineer-in-Charge. Make-Kirloskar/CG/Mather platt.
Pump impeller made out of stainless steel or as per existing specification. Make : Kirloskar/Wilo Mather Platt or equivalent make as approved be GE.
Pump shaft stainless steel shaft complete with check nut and keys.
Tyre coupling/star coupling or as per existing at site.
Gland cup.
Shaft sleeves.
Welding remelting and turning finishing cutting of key ways in respect of pump shaft.
Bearing housing.
Material & labour for quarterly AMC for fire sprinkler system installed at NCHNC by checking the flow of water through the line, flow switch, gong bell etc any leakages found may be rectified and testing functioning and submitting the quarterly testing report alongwith the fire inspector report once in a year , complete all as specified and directed by the Engineer-in-Charge.
Material & labour for quarterly AMC for fire hydrant (Single/Double,External/Internal) system installed at NCHNC by checking the pressure of water through the line, leakages found may be rectified and testing function of RRL hose nozzle and submitting quarterly testing report alongwith fire inspector report once in a year , complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for replacement of fire hydrant tikkri suitable for 63mm fire hydrant valve, complete all as specified and directed by the Engineer-in-Charge.
Material & Labour for replacement of fire hydrant rubber washer suitable for 63mm fire hydrant valve , complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Led Indicators as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing push buttons as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing voltmeter as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Ampere Meter with CTs as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing MCB 4pole 6-32A as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing MCB 1pole 6-32A as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing single phase preventer as per existing make and specification, complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing Pressure release valve as per existing size installed on pressurre vessel, complete all as specified and directed by the Engineer-in-Charge.
Supply and installation of fire panel for automation of fire pump made out of MS Sheet and degree of protection IP45 with MCB 4 pole 32 Amps as incomer suitable for 10 HP fire pumps with starter, relays, contactor, single phase preventer, manual mode and auto with voltmeter and ammeter , complete all as specified and directed by the Engineer-in-Charge.
Material & labour for servicing of diesiel engine driven fire hydrant pump with draining out of engine oil and top up with new oli and replacement of oil filters, fuel filter ,air filter and topping up with new coolant, tightening of all nut and bolt , complete all as specified and directed by the Engineer-in-Charge.
Material & labour for serviceability of fire panel( Main, Jockey & DG) installed at NCHNC with checking of auto/Mannual mode for its operation of required pressue for the auto operation of pump, checking the working of relays/ contactor and tightening the loose contact if any and replacement of lugs, note dowm the the cut off/on pressure rating of each pump and submitted to the department, complete all as specified and directed by the Engineer-in-Charge.
Supply, erection testing & commissioning of pot strainer / Y strainer including rubber insertion, bolts, nuts, Gl flanges, etc complete for 150mm bore of pipes, complete all as specified and directed by the Engineer-in-Charge.
Description all as per serial item No 67.00 here-in-before but of size 100 mm bore.
Supply erection, testing and commissioning of hydraulically operated sprinkler alarm unit connected to sprinkler system (150 mm dia) floor comprising of alarm valve, water motor with alarm gong, pressure gauge, drain cock, check valve and pressure reducing valve. The quoted rate shall also including the necessary accessories, complete all as specified and directed by the Engineer-in-Charge.
Flow switch installed on the sprinkler main distribution line connected to the main sprinkler annunciation panel located in the ground floor suitable for 100mm bore pipe, complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing Intelligent addressable Optical Based smoke and heat detector with facility of numbering in the base( UL Listed), complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing Intelligent addressable Manual Pull Station and shall be resettable type.( UL Listed) , complete all as specified and directed by the Engineer-in-Charge.
Material & labour for response Indicator (uL ) listed, complete all as specified and directed by the Engineer-in-Charge.
Supply & fixing 2 Core X 1.5 Sq.mm multistrand armoured copper cable with all accessories and 2 complete in all aspects, the cable shall be having cable pointers at every 1 Meter. These cables shall be used for the wiring of detectors and devices, complete all as specified and directed by the Engineer-in-Charge.
Material & labour for quarterly AMC for Intelligent addressable Micro processor based fire alarm control panel with 02 loop capacity Networkable and expandable, with dual stage alarm facilities like hooter, fire / fault indicators, audio-visual signals, auto learn features, flexibility in shared zone mode or stand alone system, PC networking connectivity as RS232/RS485, communication facility, suitable for connect other systems. shall be interfaced to Graphic Software, having inbuilt power supply, complete all as specified and directed by the Engineer-in-Charge.
Material & labour for providing and fixing of 12mm / 15mm dia anchor fasteners for suspending Gl rods / brackets etc, complete all as specified and directed by the Engineer-in-Charge.
Supply.erection, testing and commissioning of 15mm dia nominal bore quartzoid bulb type sprinklers with temperature rating of 68 deg C conventional type the shall also include suspending arrangement with ceiling, wall arrangement with ceiling, wall beam clamps, fasteners ceiling rosette (incase of false ceiling) etc, complete all as specified and directed by the Engineer-in-Charge.
Concealed type
Upright type
Sidewall type
Pendant type
Supply, Erection, testing & comissioning of SS Flexible Pipe of suitable dia and length required for connecting , complete all as specified and directed by the Engineer-in-Charge.
Supply and fix in replacement of gun-metal, globe or gate valves, 50mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), including taking down the old existing complete all as specified & directed by Engr-in-Charge.
Supply and fix in replacement of gun-metal, globe or gate valves, 25 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), including taking down the old existing complete all as specified & directed by Engr-in-Charge.
Supply and fixing In line duct series fan of rating 230V, frequency 50Hz, RPM 2600 with air flow 500 m³/hrs complete all as specified and directed by Engr-in-Charge. Make: - WadBros, Polycab and equivalent.
Supply and fixing PVC pipe of dia 6" of length 6 mtr alongwith connected accessories i.e. band, Tee etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC disc wall diffuser of dia 6" with manually adjustable air flow complete all as specified and directed by Engr-in-Charge.
Supply and fixing PVC grill protection louvers of size 6" x 6" in square form complete all as specified and directed by Engr-in-Charge
Misc items for connection such as MS slotted base 200 mm-01 Nos, bullet fasteners 10mm-01 Nos, threaded rod 10 mm-01 Nos, nut and washer 10 mm-01 Nos, all items in qty one number complete all as specified and directed by Engr-in-Charge.
Supply and fixing Exhaust vent F-06 size 150mm, rated voltage 240V, RPM 2100, air flow 320 m³/h made of ABS plastic body noise 35db make WadBros, Polycab, complete all as specified and directed by Engr-in-Charge.
Supply and fixing of ERV (Energy Recovery Ventilator) of size 650x500x200mm of air flow (high) 150 & (low) 100 m³/h with power consumption (high) 82 & (low) 70 with PVC duct of size dia 100 mm and complete with Activated carbon filter & HEPA filter for index of PM 2.5 finer allergens and microbs complete all as specified and directed by Engr-in-charge. Make :- WadBros, Polycab and equivalent.
slathia construction works (BID ID -3375816)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .