| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC | L1 | Accepted-AOC Awarded being 1st Lowest Bidder | |
| 2 | L2₹20.1 L+₹7.8 L (62.7%)Rejected-Finance RM 01 RIDHISIDHI I SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | L2 | Rejected-Finance Rejected being 2nd Lowest Bidder | |
| 3 | L3₹20.3 L+₹8.0 L (64.7%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Rejected being 3rd Lowest Bidder | |
| 4 | L4₹21.0 L+₹8.6 L (69.8%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L4 | Rejected-Finance Rejected being 4th Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹39,680
Closing Date
11 Jan 2021, 6:00 pmClosed
COMMANDER WORKS ENGINEER, SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CA NO. CWE SGNR - 39 OF 2020-21 SPECIAL REPAIRS TO LT PANEL AND CONVERSION OF LT OVERHEAD LINE INTO UNDERGROUND LT CABLE FOR OTM ACCOMMODATION AT MILITARY STATION SRI GANGANAGAR
2020_MES_383941_1
CA NO. CWE SGNR - 39 OF 2020-21
Open Tender
Civil Works - Others
Item Rate
180 days
GE SRI GANGANAGAR
Class E
Category b(i)
10 documents required · 10 mandatory
₹500
GE SRI GANGANAGAR
₹39,680
Yes
29 Jan 2021
14 Dec 2020
13 Jan 2021
14 Dec 2020
11 Jan 2021
28 Dec 2020
Amount
Supplying, laying, jointing and testing and commissioning 150Sqmm, 3.5 Core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVC sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches / ducts / fixed on poles / wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning 120Sqmm, 3.5 Core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVC sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches / ducts / fixed on poles / wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning 70Sqmm, 3.5 Core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVC sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches / ducts / fixed on poles / wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning 50Sqmm, 3.5 Core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVC sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches / ducts / fixed on poles / wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning 25Sqmm, 4 Core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVC sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches / ducts / fixed on poles / wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning 16Sqmm, 4 Core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVC sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches / ducts / fixed on poles / wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing and commissioning 10Sqmm, 2 Core XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor and PVC sheathed LT cable 1100 Volts grade conforming to IS-7098 laid in trenches / ducts / fixed on poles / wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engineer-in-Charge.
Supplying, installing, testing and commissioning of totally closed LT panel outdoor type of size 1.2 x 1.2 x 0.6m (IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for MCCBs, bus bar chamber enclosed) including suitable for opening on 415 volt 50 Hz AC supply internally wired with copper conductor, TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves and clips on surrounding for joints, busbar shall be designed to withstand a fault lavel 50 KA at 415 volt having legs 45 cm made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cm. Brick masonary platform should be 60 cm above the ground level complete all as specified and directed by Engineer-in-Charge, Comprising the following: (i) The panel shall be front operated with cable entry from the bottom with cable glands. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 60 cm (i) Incoming MCCB 400 Amp, 25 KA, 4 Pole, breaking capacity microprocessor based (Ics=100% Icu) and trip setting as required - 01 No. TPN Bus Bars: 01 set of 400 Amps aluminium bus bar of suitable length and of cross section as per design. bus bar shall be designed to with stand a fault level of 50 KA at 415 volts. Outgoing: (i) MCCB 200 Amp, TP, 415 volt, 25 KA breaking capacity microprocesor based (Ics=100% Icu) and trip setting as required - 02 Nos (ii) MCCB 160 Amp, TP, 415 volt, 25 KA breaking capacity microprocesor based (Ics=100% Icu) and trip setting as required - 02 Nos (iii) MCCB 100 Amp, TP, 415 volt, 25 KA breaking capacity microprocesor based (Ics=100% Icu) and trip setting as required - 02 Nos Instrumentation: (i) 01 Set of indicator lamp (R, Y, B), (ii) Trivector meter with suitable CT complete Set - 01 No. Note: (i) Cost of construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (12.5 mm thick stone aggregate) deemed to be including in the item rate. (ii) Width of the panel not less than 60cms. (iii) Removing ACB from existing panel and refixing of new panel including, servicing of ACB, (iv) Removing of existing APFC panel from panel and deposit to MES store yard, (v) Rates of items mentioned in note No (i) & (iv) Rates shall be inclusive in the quoted rates of respective item. No extra payment will be made on this account.
Supplying, installing, testing and commissioning of totally closed LT panel outdoor type of size 1.2 x 1.2 x 0.6m (IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for MCCBs, bus bar chamber enclosed) including suitable for opening on 415 volt 50 Hz AC supply internally wired with copper conductor, TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves and clips on surrounding for joints, busbar shall be designed to withstand a fault lavel 50 KA at 415 volt having legs 45 cm made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cm. Brick masonary platform should be 60 cm above the ground level complete all as specified and directed by Engineer-in-Charge, Comprising the following: (i) The panel shall be front operated with cable entry from the bottom with cable glands. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 60 cm (i) Incoming MCCB 200 Amps, 25 KA 4 Pole, breaking capacity microprocessor based (Ics=100% Icu) and trip setting as required - 01 No. TPN Bus Bars: 01 set of 400 Amps aluminium bus bar of suitable length and of cross section as per design. bus bar shall be designed to with stand a fault level of 50 KA at 415 volts. Outgoing: (i) MCCB 160 Amp, TP, 415 volt, 25 KA breaking capacity microprocesor based (Ics=100% Icu) and trip setting as required - 02 Nos (ii) MCCB 100 Amp, TP, 415 volt, 25 KA breaking capacity microprocesor based (Ics=100% Icu) and trip setting as required - 03 Nos Instrumentation: (i) 01 Set of indicator lamp (R, Y, B), (ii) Trivector meter with suitable CT complete Set - 01 No. Note: (i) Cost of construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (12.5 mm thick stone aggregate) deemed to be including in the item rate. (ii) Width of the panel not less than 60cms. (iii) Removing ACB from existing panel and refixing of new panel including, servicing of ACB, (iv) Removing of existing APFC panel from panel and deposit to MES store yard, (v) Rates of items mentioned in note No (i) & (iv) Rates shall be inclusive in the quoted rates of respective item. No extra payment will be made on this account.
S&F on pole / wall / in panel / with fabrication of standard, sheet metal encosure, bus bar chamber consisting 4 pole 100 Amps 415 volts aluminium bus bar suitable for connecting cable as a junction including connecting of cables with suitable size aluminium thimbles, cable glands including earth work and PCC complete all as specified and directed by Engineer-in-Charge.
Supplying, installing, testing and commissioning of totally closed LT panel outdoor type of size 1.2 x 1.2 x 0.6m (IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type (independent cabin including locking arrangement for MCCBs, bus bar chamber enclosed) including suitable for opening on 415 volt 50 Hz AC supply internally wired with copper conductor, TPN bus bar of aluminium strip (4 Nos) insulated by heat shrinkable sleaves and clips on surrounding for joints, busbar shall be designed to withstand a fault lavel 50 KA at 415 volt having legs 45 cm made out of 65x65x6 mm angle iron grouted on brick masonary plateform upto 30 cm. Brick masonary platform should be 60 cm above the ground level complete all as specified and directed by Engineer-in-Charge, Comprising the following: (i) The panel shall be front operated with cable entry from the bottom with cable glands. (ii) Fabrication of feeder pillar box to be approved by CPRI width of the panel not less than 60 cm (i) Incoming MCCB 160 Amp, 25 KA, 4 Pole, breaking capacity microprocessor based (Ics=100% Icu) and trip setting as required - 01 No. Bus Bars: 01 set of 200 Amps TPN aluminium bus bar of suitable length and of cross section as per design. bus bar shall be designed to with stand a fault level of 50 KA at 415 volts. Outgoing: (i) MCCB 100 Amp, FP, 415 volt, 25 KA breaking capacity microprocesor based (Ics=100% Icu) and trip setting as required - 05 Nos Instrumentation: (i) 01 Set of indicator lamp (R, Y, B), (ii) Trivector meter with suitable CT complete Set - 01 No. Note: (i) Cost of construction of plateform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (12.5 mm thick stone aggregate) deemed to be including in the item rate. (ii) Width of the panel not less than 60cms. (iii) Removing ACB from existing panel and refixing of new panel including, servicing of ACB, (iv) Removing of existing APFC panel from panel and deposit to MES store yard, (v) Rates of items mentioned in note No (i) & (iv) Rates shall be inclusive in the quoted rates of respective item. No extra payment will be made on this account.
M&L for earthing complete with galvanized iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 Mtr deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level, connected to and including GI strip 32mm x 6mm (upto the body of equipment) by means of GI bolts / nuts / washers, protected by 40mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15cm thick all around bottom and top. 20mm bore GI light grade pipe for watering and including funnel, wire mesh, RCC cover and frame, PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) as in earthing pit incuding necessary excavation and earth work, all as specified and shown in electrical plate No. 3 of MES Schedule Part - I complete all as specified and directed by Engineer-in-Charge. Note : the unit rate includes earthing lead and protection pipe upto 7.5 Metre from top of earth plate.
S&F on poles / wall / in panel / with fabrication of stand, sheet metal enclosure, bus bar chamber consisting 4 poles 400 Amps 415 volts aluminium bus bar suitable for connecting cable as a junction including connecting of cables with suitable size aluminium thimbles, cable glands including earth work and PCC complete all as specified and directed by Engineer-in-Charge.
Dismantling of existing cross arms, brancing, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engineer-in-Charge. Note : Exposed steel surface shall be treated with two coats of aluminium paint over a coat of red oxide primer and unexposed surfaces of steel sections shall be applied one coat of red oxide primer. Rate of painting shall be incudding in the quoted rate of item. Refixing of existing bracket, street light fittings and connected items rate shall be included in this quoted rate of item.
Dismantling of ACSR conductor of any size and capacity including all connected items from over head lines complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of PVC insulated and PVC rounded sheathed unarmoured solid aluminium conductor heavy duty industrial cable of 1100 volt grade as per IS-694 of size 2.5 Sqmm 3 core conductor and making connection of street light fittings with underground cable / cable should be passing through stainless steel saddle on PCC pole / steel pole from pole box to street light connection, saddle distance not more than 30cm on pole complete all as specified and directed by Engineer-in-Charge.
S&F for shock, rust proof fire retardant class FV-0 as per IS-11731 Part-II or V-0 as per UL-94, high heat distortion temperature FRP junction box of size 300x200x105mm with locking arrangement made out of 3mm thick PVC sheet including provision of 4 Nos. aluminium bus bar of size 20x3mm mounted on insulator 01 No. MCB, SP 10 KA 240 volts, drilling holes for outgoing and incoming cable (2 ways) connection with suitable lugs and glands including provisionof clamp made out of 40x5mm thick mild steel flat iron complete all as specified and directed by Engineer-in-Charge.
Excavationin trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth of pipe line, cable trenches or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out of soft / loose soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for sand cushioning with layer of sand 8 CM thick before laying of cable and 15 CM thick after laying of cable to the full width of trench and punning down to 18 CM thick complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs, GI pipe 40 mm bore light grade for protection of cable laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs, GI pipe 80 mm bore light grade for protection of cable laid under the road / laid under the floor or in trenches complete all as specified and directed by Engineer-in-Charge.
M&L for boring holes under road / pavement / hard standing or any other situation by manual means suitable for passing GI pipe 80mm bore and making good both the ends complete all as specified and directed by Engineer-in-Charge.
S&F in replacement street light timer, single phase for 5KW light load comprising of nature switch, contactor and MCB housed in a pole mountable enclosure complete all as specified and directed by Engineer-in-Charge.
S&F in replacement street light timer, three phase for 8KW light load comprising of nature switch, contactor and MCB housed in a pole mountable enclosure complete all as specified and directed by Engineer-in-Charge.
Dismantling of any type of insulators complete all as specified and directed by Engineer-in-Charge. --------------------------------------------------------------------------------------------------- Note : A sum of Rs. 1,05,750.00 will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 21(R) (Schedule of Credit) of Tender document
KHANNA CONSTRUCTIONS
Singla Electricals
M/S BUDHRAM BISHNOI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .