₹69 L
EMD Value
₹1.3 L
Closing Date
9 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col N K Chaudhary
HQ 137 Wks Engr PIN 914137 c/o 99 APO
SPL REPAIR/ REPLACEMENT OF VARIOUS CAPACITY OF PUMP SETS AND COOLING APPLIANCE ALONGWITH ALL RELEVENT WORKS AGAINST BER AT ZAKHAMA MIL STN
2023_MES_611678_3
8771/E8
Open Tender
Civil Works
Item Rate
180 days
Zakhama
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
AGE (I) Zakhama
₹1.3 L
Yes
23 Jan 2024
18 Dec 2023
16 Jan 2024
18 Dec 2023
9 Jan 2024
26 Dec 2023
Amount
Supply, installation, commissioning of Metal Top Deep Freezer single phase 240 volt, 50 Hz of minimum capacity 425 ltrs, compete all as specified and directed.
Supply and fixing refrigerator, electric driven (single phase), capacity minimum 310/320/330 Litres BEE 3 star rated and compete all as specified and directed.
Supply and fixing Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and suitable for refrigerator upto 425 Ltr capacity compete all as specified and directed.
Material and labour for dismantling carefully without damaging to existing unserviceable split AC removing complete assembly indoor and outdoor Units with all accessories electric connections and depositing to MES Store yard complete all as specified and directed. Note: The reqd manpower, tools and plants, transportation etc is deemed to be included in the quoted rate.
Material and labour for sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.0 sqmm (Nominal area) drawn through in and including PVC Casing/Caping with all fitting and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi standerd FRLS Copper Conductor cable of size 4.0 sqmm as earth lead and connected to earth dolly and including taking down old unservicible sub main wiring of any description making good to disturbed surface complete all as specified and directed. Note:- 3 Runs of 4.0 sqmm cable and one run of PVC casing/Caping shall be measured as one unit length.
Supply and fixing in repairs Utility DB P/S 20A DP Metal plug and Socket Distribution Board complete all as specified and directed.
Supply and fixing copper tube for split AC size1/4,3/8 inch with insulation incl taking of old unservicible copper tube complete all as specified and directed. Note:- Discharge and suction pipe including insulation measured as one unit.
Supply and fixing Voltage Stabilizer for automatic Operation,3.0 KVA single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + - 2.5% and suitable for AC of capacity 2 TR/ Deep Freezer of capacity 425 ltrs, complete all as speciifed and directed. Note:-Necessary Suitable size of platform PCC type B1 1:2:4(20mm graded aggregate), clamps,nut bolts required for fixing outdoor unit deemed to be included in quoted rate.
Supply, install, commissioning & testing of hi wall, split-type Air conditioner Unit of capacity 1.5 TR based on Inverter Technology comprising of indl indoor & outdoor units complete with cordless remote control unit & with cooling and heating function incl electric connection complete all as specified and as directed. Note :(i) The air conditioner shall be initial filled / charged with refrigerant of specified quantity and the refrigerant to be used shall be Non-CFC type and as per the latest technology. (ii) The cost of refrigerant pipes required is deemed to be included in the unit quotes rates. (iii) Suitable piping of adequate length and size 5/8" for drainage of condensate water from indoor unit shall be provided and the cost of the same is deemed to to be included in the unit quotes rates. (iv) All spare parts tecnically required for efficient working of the AC but not mentioned are deemed to be included in the unit quoted rates.
Material and labour for taking out carefully without damaging to existing unserviceable centrifugal pump set of capacity 10 HP by removing all water supply inlet and outlet connections ,electric connections and depositing to MES Store yard for disposal action and complete all as directed. Note: The reqd manpower, tools and plants, transportation etc included in the quoted rate.
Supply , installation , testing and commissioning of centrifugal multistage pump set horizontal type suction / delivery -65x50mm, discharge capacity-38 cum/hr, 280 mtr head, mechanical seal arrangement including 3-phase energy efficient squirrel cage induction motor as prime mover, 415 V, S1 duty rating, energy efficiency level -IE 2 BEE star rated, ISI Marked 75 HP (55 KW) 2960RPM as per IS- 12615 ( latest edition) fixed to pump through jaw type coupling with pump impellor of cast iron and shaft of 40 C 8 including pump set mild steel base frame suitable size complete, including Suitable size of foundation, PCC type B1 1:2:4(20mm graded aggregate), rubber packing including taking down of old unsv pump set upto 75 HP capacity from foundation and removing from site and deposited to MES store yard complete all as specified and as directed.
Supply , installation , testing and commissioning of 10 HP/7.5 KW centrifugal monoblock pumpset, electric driven, 3 phase, 415 volt, min head 30 mtr, discharge 40 cum/ hr, efficiency 65%, speed 2900 rpm, impeller & casing CI, shaft CS45C8, Base plate MS fabricated,Coupling, Coupling Guard,Foundation bolts & Nuts including starter of suitable capacity and PCC foundation and complete all as specified and as directed.
Supply , installation & testing of soft starter suitable for 75HP/55Kw pump set , Rated frequency 50/60 Hz 3 pole with motor protection and inbuilt by pass contactor having protection function for motor over load relay,phase loss,excess start time,phase sequence corrector,single phase preventor motor, thermistor,power circuit fault,supply frequency including making all necessary connection with assit of service engineer of OEM etc with fixing in existing panel/fixing on wall with encloser and removing existing starter by disconnecting its connection all as specified and directed. (Note : Charges for Service Engineer Visit is deemed to be incl in quoted rate)
Supply and fixing FRLS PVC insulated single core unsheathed singlestranded copper conductor for voltage grade 1100V of size 50 sqmm with suitable flexible pipe including taking down old unsv copper conductor cable of any description complete all as specified and as directed.
Supply and laying in repairs GI tubing, of size 100mm ISI Marked, medium grade with all fittings specials such as bend, elbows,tees, short pieces connection, back nuts, caps, plugs and unions etc fixed complete to walls or laid in floors. Complete all as specified and directed. ( Note : Necessary excavation,refilling, removal of soil and making surface good if required is deemed to be incl in quoted rate.)
Supply and fixing FRLS PVC insulated single core unsheathed singlestranded copper conductor for voltage grade 1100V of size 10sqmm with suitable flexible pipe including taking down old unsv copper conductor cable of any description complete all as specified and as directed.
Supply and fixing in repair CI resilient (soft) seated gate valve with pocket less body, SS stem ( AISI 410), EPDM coated CI wedge 100% vaccum tight design with toroidal sealing ring & over 250 micron epoxy coating in PN 1.6 designed to BS :5163/IS:14846 non-rising stem type with hand wheel operation , nominal dia 100 mm with flanges and complete all as specified and directed
Supply ,Install,testing and commissining of CI Non-Return (Reflux) Valve 100mm bore,both end flanged,class PN 1.6, ISI marked conforming to IS 5312 (Part I&II) including making new rubber gasket joint, necessary nut bolts ,washer etc of suitable size including taking down old unsv NRV of any size complete all as speicifed and diretced.
Supply and fixing in repair cast iron foot valve flanged ends swing type operation with rubber gasket of dia 100mm as per IS 4038 and complete all as speicifed and diretced.
Supply and fixing In Repair Cast Iron Flanged Y Type Strainers With SS Mesh, to avoid foreign material, in PN 1.0 of dia 100mm and Complete all as Speicifed and diretced.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion including taking down old unserviciable earthing set all as specified and as directed. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department.
thepfuralie zutso
Rameshwar Prasad
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .