| 1 | L1₹4.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.3 L+₹1.8 L (38.9%)Rejected-Finance D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L2 | Rejected-Finance L2 | |
| 3 | L3₹6.3 L+₹1.8 L (39.6%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹6.4 L+₹1.9 L (41.5%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L4 | Rejected-Finance L4 | |
| 5 | L5₹6.7 L+₹2.2 L (48.4%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L5 | Rejected-Finance L5 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
9 Aug 2021, 6:00 pmClosed
GE AF FARIDABAD
Garrison Engineer AF Faridabad Dabua Colony Faridabad Haryana Pin-121005
REPAIR OF INTERNAL WIRING FITTING AND EXISTING FITTING WITH LED FITTING IN TECH AREA AF STN BASANT NAGAR AND 415 BASANT NAGAR OFFR MESS
2021_MES_461438_1
GE (FBD)/AF-29/2021-2022
Open Tender
Civil Works
Item Rate
180 days
PALAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF FARIDABAD
₹20,000
Yes
9 Sept 2021
20 Jul 2021
11 Aug 2021
20 Jul 2021
9 Aug 2021
27 Jul 2021
21 Jul 2021 - 26 Jul 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified & directed by Engineer-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in existing concealed conduit, fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush box of suitable size modular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified & directed by Engineer-in-Charge for following :-. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 2 above but 5 Amp socket outlet, independent complete all as specified & directed by Engineer-in-Charge.
All as per item No 2 above but on the same board complete all as specified & directed by Engineer-in-Charge.
All as per item No 2 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified & directed by Engineer-in-Charge.
All as per item No 2 above but 4.0 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified & directed by Engineer-in-Charge.
M&L for socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified & directed by Engineer-in-Charge.
M&L for socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified & directed by Engineer-in-Charge.
M&L for switch 6 amps modular type one one way complete all as specified & directed by Engineer-in-Charge.
M&L for switch 16 amps modular type one one way complete all as specified & directed by Engineer-in-Charge.
M&L for modular type fan regulator (Step type) , 120 W-1 module complete all as specified & directed by Engineer-in-Charge.
M&L metal flush box 3 module complete all as specified & directed by Engineer-in-Charge.
M&L metal flush box 6 module complete all as specified & directed by Engineer-in-Charge.
M&L metal flush box 12 module complete all as specified & directed by Engineer-in-Charge.
M&L for white cover plate with frame, 12 module complete all as specified & directed by Engineer-in-Charge.
M&L for white cover plate with frame, 6 module complete all as specified & directed by Engineer-in-Charge.
M&L for white cover plate with frame, 3 module complete all as specified & directed by Engineer-in-Charge.
S & F in replacement enviroment friendly recess/pendent mounting LED flat panel 2'x2', coowhite with high efficient LEDs & glare free opal diffuser (36 W) PF>0.95 driver life >25000 Hours, operating range 140v to 280 V including complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of Recesses mounting LED slim round downlighter 12 Watt warmwhite with high efficient LEDs & glare free opal diffuser complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of enviroment friendly indoor decorative 20 Watt LED Batten with opal diffuser including all accessaries complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCB SPN 32 to 63 Amps, 240 volts, curve 'C', breaking capacity 10 KA, complete all as specified & directed by Engineer-in-Charge.
S&F in replacement MCCB, three pole, 415 volts, 125 Amps breaking capacity 16 KA, Thermal magnetic tripping, fixed type, complete all as specified & directed by Engineer-in-Charge.
S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for MCCB TP as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer .
S&F in replacement sheet metal enclosures DB Double door type 8 way SPN 240 volt including 200 Amps rated bus bar with neutral link complete all as specified & directed by Engineer-in-Charge.
S&F for ceiling rose surface bakelite 65x50mm two to three terminals complete all as specified & directed by Engineer-in-Charge.
S& F in repair casing capping of size 20 mm to cover the copper conductor in wall complete all as specified & directed by Engineer-in-Charge.
S&Fin repair LED flood light 60 watt ISI marked,enviromental friendly high efficient,pressure die cast with aluminium extruded Heat sink IP66 complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of LED electronic driver suitable for 36 Watt LED (2"x2") recesses mounted fitting complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of three core FRLS cable PVC unsheathed with copper conductor of size 4.00 Sqmm and drawing into existing conduit complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of capacitor of following sizes complete all as specified & directed by Engineer-in-Charge. (a). 2.5 Mfd.
All as per item No 31 above but 3.15 Mfd complete all as specified & directed by Engineer-in-Charge.
M&L for rewinding of burnt fan 1200 mm sweep with super enameled copper wire winding, rubber real, U’ clamps, nuts, bolts, washers and split pins of suitable size as per details of any make/model complete all as specified and directed by Engineer-in-charge.
Supply in replacement for rewinding of exhaust fan as per details given below with supper enameled copper wire of suitable size of any make/type/model including transportation complete all as specified and directed by Engineer-in-Charge :- (a) Exhaust fan 300mm (12’size sweep)
M&L for rewinding of wall mounted fan given below with super enameled copper wire Including of suitable of size of any make/type model complete all as specified and directed by Engineer –in-charge :-(a) Wall fan of size 400mm
S&F in repair LED 10 watt bollard with aluminum pipe housing with glare free PMMA Diffuser IP65 including making foundation and grouting the bollard light complete all as specified & directed by Engineer-in-Charge.
Supply only High Strength Calcium based granular disinfectant for water treatment, in factory sealed non returnable HDPE containers (45 Kg each) having chlorine concentration level 65% or above complete all as specified & directed by Engineer-in-Charge.
Chemical analysis of water sample collected from MES borewell to check the TDS and impurities level in the sample complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of plastic body exhaust fan 250 mm size complete all as specified & directed by Engineer-in-Charge.
S&F in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade,cross-sectional area 6 sqmm 2 core all as specified and directed by Engineer-in-Charge.
M&L for repair/maintenance of Solar Water Geyser 50 ltr of capacity including cleaning of tank and copper plate ,removal of scalp with chemical solution and testing for working satisfactorily complete all as specified & directed by Engineer-in-Charge.
Supply and fix in repair heating element for solar water haeter of capcity 2 KW complete all as specified & directed by Engineer-in-Charge.
Supply and fix in repair heating element for water heater of capcity 2 KW complete all as specified & directed by Engineer-in-Charge.
S&f in repair highly efficient high LED street light 25 watt building light with lens made of high pressure die cast Al housing reflector and enclosed with toughened glass IP66 complete all as specified & directed by Engineer-in-Charge.
Supply and fix in replacement of flame proof exhaust fan 300 mm sweep iron body with all accessories complete all as specified & directed by Engineer-in-Charge.
Supply and fix in replacement of ceiling fan 1200 mm Sweep 5 star rating with all accessories complete all as specified & directed by Engineer-in-Charge.
Supply and fix in replacement of exhaust fan 300 mm Sweep iron body with louver incl all accessories complete all as specified & directed by Engineer-in-Charge.
Yield testing of the MES borewell located at pump house no 1 including yield testing report in LPM complete all as specified & directed by Engineer-in-Charge.
Supply and fixing in replacement of solar street light fittings with integrated 20 Watt LED street light system with solar PV Panel 100 Wp, integrated LED fitting with Li-Ion Battery 11.1 V 17 Ah , MPPT based solar charge controller , Motion Sensor and tubular pole of height 5 Mtrs complete all as specified & directed by Engineer-in-Charge.
Supply and fix in replacement of solar street light Li-Ion 12 V 80Ah battery suitable for 45 Watt LED light complete all as specified & directed by Engineer-in-Charge.
S&F for sheet metal enclosure with single pole and neutral enclousure with a two pin and earth plug and socket complete with single pole MCB 20 Amps complete all as specified & directed by Engineer-in-Charge.
M/s Navansh Engineers & Consultants
H.B. Traders
Saini Enterprises
M/S Anand Enterprises
Commercial Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .