Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹4.2 L+₹26,000 (6.68%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹5.3 L+₹1.4 L (36.5%)Rejected-Finance | L3 | Rejected-Finance Being L3 |
Tender Value
₹4.7 L
Closing Date
3 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PATIALA
HQ CWE PATIALA
Replacement of U S Capacitors and Battery charging unit in 66 KV Grid station at Patiala Cantt under GE North Patiala
2021_MES_496863_2
3001/Job/2021-22/35/E3
Open Tender
Electrical and Maintenance Works
Works
60 days
GE NORTH PATIALA
As per cover 1
2 documents required · 2 mandatory
₹0
Exempted
16 Feb 2022
19 Jan 2022
5 Feb 2022
19 Jan 2022
3 Feb 2022
22 Jan 2022
19 Jan 2022 - 20 Jan 2022
30 days
Amount
1. Replacement of capacitor having capacity of 137.3KVAR, 6.99KV 1 Ph, 2 Bushing, CRCA container, BIL-28/75 KV peak : Quantity = 03 Each Note : The rate quoted by trader deemed to be included for testing the capacitor bank and to find out the defective capacitor before replacement. 2. Replacement of FCBC panel, full wave full controlled, battery type VRLA/NI-CD/Planet/Tubular, 415V AC+- 5% (Three phase, three/Four wire) 50 Hz+- 5%, 110 VDC 50A, ripple 2% RMS (without battery connected), Eff. Greater than 80%, auto phase reversal operation, Freestanding cabinet, floor mounting type, sheet steel construction, IP-42, CRCA sheet 2.0 mm thickness, natural air coolilng Panel complete : Quantity = 01 Each * Works pertains to HT, Bidder shall have valid electric license.
Description of Works :-
Supply, installation and commissioning of Capacitor unit of size 137.3 kVAr, 6.99 kV 1 ph 2 bushing CRCA container 50 Hz same as per existing units HT power factor correction capacitor, EPCOS INDIA PV LTD - Each, Qty=03
Supply, installation and commissioning of Battery Charger, Panel Float cum boost charger 110V/50A compatible with existing battery cells at substn with flg specifications: a) Input (415V AC ±10%, 50Hz ± 5%), b) OUTPUT : 110VDC, Output Currents : 50A Ripple : 2% RMS (Without Battery connected), Efficiency : > 80% (c) Voltage regulation: Charger output is ±1% of the set value in the following conditions in set mode (FLOAT /BOOST/AUTO), Load variation : 10-100%, Line variation : ± 10%, Frequency Variations : ± 5%, Temperature Variations : 0 ºC to +50 ºC (d) INDICATIONS: Cluster LED Lamps will be provided for “AC Mains ON (R, Y, B)” condition. The following indications will be provided in the charger system by 5mm LEDs: AC Mains ON, Charger ON, Float ON, Boost ON, AC Mains Fail, Charger Over Voltage, Charger Under Voltage, SCR Fuse Fail, Battery Fuse Fail, Battery Earth Fault Charger Fail, Group Alarm, Load Under Voltage, Load Over Voltage, Battery Reverse Polarity (provided at Battery Termination) (e) DISPLAY: The following parameters will be displayed on LCD: AC Input Voltage either Line to Line or Line to Neutral, AC Input Current in each phase, Charger Output Voltage, Charger Output Current, Battery Voltage, Battery Charge/Discharge Current, Load Voltage, Load Current, Charger ON/OFF, Alarms. ALARMS WITH BUZZER, AC Mains Fail/Out of Limit : Both LCD and LED Indication, SCR Fuse Fail : Both LCD and LED Indication, Battery Fuse Fail : Both LCD and LED Indication, Charger Fail : Both LCD and LED Indication, Charger Under Voltage : Both LCD and LED Indication, Charger Over Voltage : Both LCD and LED Indication, Battery Earth Fault : Both LCD and LED Indication, Group Alarm : Both LCD and LED Indication - Each, Qty=01
(f) POTENTIAL FREE CONTACTS: For following PFCs will be provided: Float ON, Boost ON, Rectifiers Fuse Fail, Charger Fail, Charger Under Voltage, Charger Over Voltage, Battery Earth Fault, Group Alarm, (g) PROTECTIONS: The following protections will be provided: AC Input Circuit Breaker, Fast acting Semiconductor Fuses for SCR Bridge, DC Over Voltage Cutback / Shut Down, DC Overload, DC Output Circuit Breaker, Battery Input Fuses, Battery Current Limit, Charger Current Limit, Blocking Diode (h) CONTROLS & SWITCHES: AC Input ON/OFF Circuit Breaker, DC Output ON/OFF Circuit Breaker, Battery Input Fuses, Socket ON/OFF Switch, Heater ON/OFF Switch, Door Lamp ON/OFF Push Button, Push Buttons: Menu; Increment; Decrement; Enter & Back (j) ENVIRONMENTAL STABILITY: Operating Temperature : -5 ºC to +50 ºC, Storage : 25 ºC to +70 ºC, Relative Humidity : 0-95% (Non-condensing), Noise Level : < 70 dB (A) (k) SPECIAL FEATURES: Auto Phase Reversal Operation, Soft Start on DC side, Class-F Insulation with Class-F Temperature Limits for all Magnetics, Automatic Voltage Regulation using Digital Control Logic, Filter Circuit to Limit Ripple, Charger Current Limiting, Battery Current Limiting, Automatic Float to Boost changeover based on current drawn by Battery, Automatic Boost to Float changeover based on Current or Voltage, Anti-condensation Heater with Thermostat Control, Remote shut Down, Blocking Diode Short Sensing, RS-485, 4-Wire Communication with Amara Raja Protocol (communication cable from Battery Charger System to user equipment like SCADA is not in Amara Raja scope), Web based Controlling & Monitoring System (Optional) [Refer O&M Manual of Web based Controlling & Monitoring System for details]
(l) GENERAL Cabinet : Freestanding Cabinet; Floor Mounting Type, Sheet Steel Construction; Easy for Installation and Maintenance; Components are accessible from Front & Rear; Cable entry at Front Bottom of the Cabinet Protection : IP – 42, Paint Shade : Exterior/Interior: RAL – 7032, Component Mounting Plates: Glossy White CRCA Sheet Thickness : Load bearing sections – 2.0mm, Non-load bearing sections – 1.6mm Undrilled Cable Gland Plate – 3.0mm, Nature of Cooling : Natural Air Cooling
AGGARWAL & CO
Shivam Engg and fabricators
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .