Electrical work connection to 1.Construction of S&T Goomti under work Provision of second goods shed common running line of CSL-730m at Pharia. 2.Provision of modular Sewage Treatment Plant at NGT nominated stations Belthara Road (BLTR) & Khorasan Road (KRND) stations. 3.Additional work of BLTR station under ABSS. 4.Additional work of SRU station under ABSS. 5.Provision of Type-II (6 unit) Type-III (1 unit) & Type-IV (1 unit) Quarter for Track machine staff at DLR. 6.MAU Jn- Extension of FOB (6.0 m wide)
E-Tender-L-23-26-27
E-Tender-L-23-26-27
Open
Works - General
6 Months
Mau, Uttar Pradesh
₹0
₹1.3 L
21 Jul 2026
21 Jul 2026
30 Jul 2026
9537/ Part III/1983 (Latest version) with accessories, junction box, etc. including making chase, plastering/ clamping etc. as per technical specifications.
9537/ Part-III/1983 (Latest version) including supply of all accessories i.e. junction box, bend, etc. as per site requirement. Please see Item Breakup for details. 597370.90 AT Par 597370.90 Description:- Supply and wiring of PVC insulated multi stranded copper conductor single core FR
pipe for wiring of point wiring/circuit wiring/ sub main/ main as required including connection, testing and commissioning as required.
Description:- Supply of PVC insulated multi stranded copper conductor single core HRFR cable 1.0
pipe for Earth Wire as required as per technical specification including connections, testing and commissioning.
05 VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY 05 Description:- Supply of PVC insulated multi stranded copper conductor single core HRFR cable 1.5 sq.mm conforming to IS: 694 (latest version), and drawing in laid (recessed /surface) PVC conduit pipe for Earth Wire as required as per technical specification including connections, testing and commissioning.
including connections, Testing and commissioning as required.
including connection with 2.5 sqmm PVC insulated copper conductor single core cable as req and conforming to IS: 694/2010 or Latest.
Description:- Supply, installation, testing and commissioning of LED LAMP Power Ratings/LED Lamp Luminous Flux 12Watt / 1200 Lumens, Colour Temperature (K) 6500, Type of Lamp CAP B22d, LAMP Efficacy (Lm/W) >/=100, LED Chip Efficacy (Lm/W) >/=130, LED Chip Efficacy (Lm/W) >/=130,
Performance and life(Volts): 220 Volt to 240 Volt, Light Source (as per LM80/IS16106): SMD LED Chip, Lamp Shell material : Polycarbonate, Ingress Protection in IP >/=20, LED life Certificate for
Standard IS 16102 part I and Part II latest.
Description:- Supply of LED Tube light with fitting power rating (in watt): 24, Lamp Efficacy (Lumen/watt) minimum :100 Colour Temperature (in K): 6500, Ingress protection in IP: IP 20,
100-300, Power factor: >/= 0.9, Warranty for free replacement (Years): 1 year, installation, connection with twin core PVC insulated flexible copper conductor cable of size 14/0.193 mm. including testing and commissioning.
Description:- Supply, installation, testing & energization of ceiling mounting 2 feet x2 feet, 36 watt LED fitting or equivalent decorative LED luminaire as per direction of engineer in-charge with
Supply, installation, testing & commissioning of Complete 2 x (18-20 Watt), 1200 mm (±2%) length, Retro fitment, T-8 type LED tube light fitting with inbuilt driver having Decorative pin type end caps and copper contacts with diffuser made of transparent polycarbonate, conforming to attached Specification.
Description:- Supply, Installation, Testing and Commissioning of Slim surface mounted Round LED
temperature range -10 degree C to +50 degree C, colour temperature 6000K, White powder coated, pressure die cast aluminum housing, integral Driver and accessories pre- wired up to terminal block, luminaire lumen output not less than 2048 lumen complete in all respect.
Description:- Supply, Installation, Testing and Commissioning of Slim surface mounted Round LED
temperature range -10 degree C to +50 degree C, colour temperature 6000K, White powder coated, pressure die cast aluminum housing, integral Driver and accessories pre- wired up to terminal block, luminaire lumen output not less than 2048 lumen complete in all respect.
Description:- Supply, installation, testing and commissioning of Ceiling fan 1200 mm sweep, Motor: Brushless DC, power consumption (W): 25-30, Winding: Copper, Speed control: 5 step with Remote,
340, Service Value >/= 7.5, conforming to IS:374/1979 and IS:374/2019 or latest, Conformity to Safety Standard IS: 302/1979 connection with twin core PVC insulated flexible copper conductor cable of size 14/0.193 mm including earthing.
mm MS Flat with nut bolts suitable to fix on PP shelter bracing angle as required.
50x6 mm, bolts, nuts and washers etc. (M.S. clamp as per site requirement)
hardware material for fixing.
VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY
operation on 230 V, 50 Hz, single phase A.C. supply, installation, testing and commissioning and connection with 2.5 sq.mm copper conductor and fixing/grouting the nut and bolts of suitable size & including making the hole on wall & colouring etc. as per site requirement.
Description:- Supply, installation, testing, commissioning of ISI Marked Exhaust fan, sweep
conforming to Indian Standard: IS 2312 (latest), suitable for single phase, 50Hz, AC, connection with 2.5 sq.mm copper conductor and fixing/grouting the nut and bolts of suitable size & including making the hole on wall in original condition i.e. colouring etc. as per site requirement.
Description:- Supply, installation, testing and commissioning of bracket/ wall mounted type Air
phase supply, 50 Hz, Max 150 watt, oscillating facility 3/4 aluminum die cast blade conforming to IS:2997/1964 or latest. Including of suitable size MS clamp as req. and as per direction of site engineer
Description:- Supply, erection, testing and commissioning of Mobile charging board made by hard
indication lamp on each board, fuse Kit Kat on each board, fixing of 205mmx160mmx10mm thick hard board sheet for supporting of mobile phone.
Description:- Fabrication, Supply, Installation, Testing and Commissioning of Mobile Charging
system is Height 5', Width - 24 ", Base - 30" (It can be customized as per client requirement) The charging station is to charge 24 Nos. of Cell Phone/Laptop together at Single Place (12 Nos at Each Side). Branding of Mobile Charging station as desired by Railway.
cover plate 2 module white and flush metal box size 3"x 3", 2 module
cover plate 3 module white and flush metal box size 4"x 3", 3 module
cover plate 6 module white and flush metal box size 8"x 3", 6 module.
cover plate 8 module white and flush metal box size 9"x 3", 8 module.
cover plate 12 module white and flush metal box size 8"x 6", 12 module.
(1-way) complete in all respect.
outlet 2/3 Pin 6/10A complete in all respect.
16/20A (1-way) complete in all respect.
outlet 5/3 Pin 16/20A complete in all respect.
per IS:3854/1997 (latest version)
twin core PVC insulated flexible copper conductor cable of size 14/0.193 mm including testing and commissioning as required.
33 VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY 33 Description:- Supply, Erection, Testing and Commissioning of following Modular type step type Electronic Fan Regulator complete in all respect.
finished mounting cover plate complete in all respect.
Version) including connections, Testing & commissioning as per site requirement.
Description:- Supply, installation, testing & commissioning of 2+4 ways single door, sheet steel,
63A isolator and 4 Nos 6-16 A, MCB, 10KA, 240/415 50 Hz with enclosure as req, MCB DB conforming to ISI 3032, IS 8623, BS 5486 and MCB conforming to IS 8828:1996, IEC 60898:2002.
Description:- Supply, Installation, Testing and Commissioning of SPN MCB Distribution Board 8 Way
No. MCB 02 Pole 40 Amp 10 KA 230V as incoming and 06 Nos. MCB of 6-20 Amp single pole 10 KA
Description:- Supplying and fixing surface/ recess mounted, vertical type, duly powder coated
MCB- 1 No, 32 A SP, MCB- 2Nos, 16 A SP, MCB- 1 No 10 A SP, MCB- 1 No, inclusive of 100A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB as required.
Description:- Supply, installation, testing and commissioning of TPN phase selector Distribution
selector switches and 3 nos piano switches as required. DBs conforming to IS13032/1991 or latest, IS 8623, BS 5486.
Amp TPN conforming to IS:13947 part III/1983 including hardware and insulators as required.
capacity 10kA with enclosure complete. MCB Conforming to IS :60898 or (Latest version) and enclosure conforming to IS:8623-1 & 3.
capacity 25 kA at 415 V,50Hz, complete with enclosure as required, conforming to IS/IEC:60947(Pt.- II)/2003 or latest.
TI/SPC/PSI/CLS/0020(12/02) with A &C slip no-1 to 4 or latest.
with erected pole or wall as per technical specification for passing cable of different size.
45 Description:- Installation, testing and commissioning of63 A DPMCB (DBMCB Supply by Railway)
2x32Amp MCB DP 10 KA as outgoing (For MCCB's Ics= 100% Icu).
VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY
distribution box with lockable hinged cover with 1.2 mm thick CRCA sheet in two compartments, one for meter etc. and other for MCB's duly powder coated approx. size 500 mm x 300 mm x 130 mm deep, suitable for operation on single phase 230 volts AC supply system complete with inter- connection with single core, PVC insulated copper conductor cable (6.00) sq.mm supply recessing and earthing including supply of RCCB25 amp. sensivity of 30 mA and shall comprise following including fixing of single phase energy meter as per DRG no L/CEE/GKP/2008/03 Meter cum distribution box comprising of (for Type- II) i)MCB DP/SPN 63 Amp.1 No. for incoming ii)MCB SP 16 amp. 4 Nos. for outgoing. iii)MCB SP 10 Amp. 2 Nos. for outgoing iv) RCCB should be suitable current/sensitivity rating - 01 no. v) Arrangement for accommodating & fixing of single phase 10A / 60A KWH meter with 6 mm thick bakellite sheet on base. Note: -Only Energy meter will be supplied by Railways. Energy meter cum distribution box should be installed outside the quarter/bungalow in covered area.
Description:- Supply , installation, testing and commissioning Pre-fabrication of meter cum distribution box with lockable hinged cover with 1.2 mm thick CRCA sheet in two compartments, one for meter etc. and other for MCB's duly powder coated approx. size 500 mm x 300 mm x 130 mm deep, suitable for operation on single phase 230 volts AC supply system complete with inter- connection with single core, PVC insulated copper conductor cable (6.00) sq.mm supply recessing
including fixing of single phase energy meter as per DRG no L/CEE/GKP/2008/03 Meter cum distribution box comprising of (for Type-III) i) MCB DP/SPN 63 Amp.1 No. for incoming ii) MCB SP 16 amp. 4 Nos. for outgoing. iii)MCB SP 10 Amp. 2 Nos. for outgoing iv) RCCB should be suitable current/sensitivity rating - 01 no. v) Arrangement for accommodating & fixing of single phase 10A / 60A KWH meter with 6 mm thick bakellite sheet on base. Note: -Only Energy meter will be supplied by Railways. Energy meter cum distribution box should be installed outside the quarter/bungalow in covered area.
Description:- Supply, installation, testing and commissioning Pre-fabrication of meter cum distribution box with lockable hinged cover with 1.2 mm thick CRCA sheet in two compartments, one for meter etc. and other for MCB's duly powder coated approx. size 500 mm x 300 mm x 130 mm deep, suitable for operation on single phase 230 volts AC supply system complete with inter- connection with single core, PVC insulated copper conductor cable (6.00) sq.mm supply recessing
including fixing of single phase energy meter as per DRG no L/CEE/GKP/2008/03 TPN distribution box comprising of (for Type-IV) i) MCB 4 Pole 40Amp 1 No. for incoming ii) MCB SP 25 amp.5 Nos. for outgoing. iii)MCB SP 16 amp 3No.for outgoing. iv)MCB SP 10Amp. 5No.for outgoing v) RCCB should be suitable current/sensitivity rating - 01 no. vi) Arrangement for accommodating & fixing of Three phase 10A/60A KWH meter with 6 mm thick bakellite sheet on base. Note: -Only Energy meter will be supplied by Railways. Energy meter cum distribution box should be installed outside the quarter/bungalow in covered area.
incoming and single phase out going double door as per IS:13032/1991 or latest. (for type-V)
MCB 63 amp, 240V,50 Hz.,10 KA, 2 pole with 1 protected pole. (for type II & III)
MCB 40 amp, 240/415 V,50 Hz.,10 KA, 4 pole with 3 protected pole.
MCB 25 amp, 240 V,50 Hz.,10 KA, 1 pole with 1 protected pole.
Hz.,10 KA, 1 pole with 1 protected pole.
Description:- Supply, Installation, Testing and Commissioning of Cable Junction Box of size 200 mm
Degree of Protection IP65/IP 66 with metric knockouts for cable entry with 5 Nos. terminal block set for cable of size 16/25 Sq.mm, bracket and cable glands complete in all respect. The material shall be inspected by RITES and inspection charges shall be borne by the firm.
56 VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY Description:- Supply, installation, testing & commissioning of Automatic changeover wall mounted
two any type of Air-Conditioner. Each AC can be kept ON from 1 hour to 24 hours. Complete in all aspect.
A,1no conforming to IS:8828-1996, IS:13032/1991, including, drilling holes on the wall/board, its connection, earthing etc. complete in all respect. (AC point)
Description:- Supply, installation, testing and commissioning of 30 A plug- sockets boards enclosure with 30A PN &E Metal plug & socket along with 25A SP MCB. Sheet steel enclosure shall
MCB shall confirm to IS/IEC -60898-1-2002 (latest version), ISI Marked, with visible coloured contact position indicator and Degree of protection IP20. Provision shall be in conformity with IS :732/1989 (Latest version), IS: 4648/1968 (Latest Version).
mounted voltage stabilizer, 220v, input voltage 140V- 260V, single phase complete and conforming to IS: 11260/1985 or latest.
indoor and outdoor including fixing arrangement etc. (1.5 TR Air Conditioner will be supplied by Railway)
air conditioner as per directives of Site Engineer and suitable to site condition
MCB 25 Amps for AC Unit complete in all respect.
Description:- Supply, Installation, Testing and Commissioning of Cable Junction Box of size 200 mm
Degree of Protection IP65/IP 66 with metric knockouts for cable entry with 5 Nos. terminal block set for cable of size 16/25 Sq.mm, bracket and cable glands complete in all respect.
Description:- Supply , testing and commissioning of sheet steel clad dust and vermin proof floor mounted type Junction box of dimension at least (Length-0.75Mtr, Height-0.60 Mtr, Width-0.50 Mtr) with 14 SWG CR sheet for main supporting frame and 16 SWG CR sheet for doors & covers including
and other hardware with RYB Led indicator, Danger board, end termination of existing cables in junction box with lugs, glands and hardware., Cleaning and painting of synthetic enamel spray paint (Double coating) including Making Plinth (Brick work) of size 0.8x0.6x0.6 Mtr for Junction box as per direction of Engineer In-charge at site
Description:- Supply, Fabrication and erection of fabricated structure of angle iron 35x35x5 mm /
arrangement of different equipment complete with clamp, nut bolt etc. complete in all respect as per site requirement.
Description:- Supply & Making Maintenance free Earthing arrangement for HV system. Earth electrode Length = 3000 mm. O Shell dia = 50 mm,O Shell thickness = 3.25 mm, Inner Shell dia 25
CEE/Maintenance Free Earthing/July 2009 Amendment No 1. All material will be supplied by Contractor.
Description:- Supply, Installation, Testing and Commissioning of Earthing with pipe 4.5 meter long
equipment with 4 mm dia G.I. wire in 15 mm dia G.I. pipe and using salt and charcoal for pipe earth electrode as per drawing L/16/STD/86 as enclosed as per IS 3043/1987 (latest Version).
connection for earthing as required.
VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY
bracket complete with two nos clamp nuts, bolts etc. suitable for mounting of LED street light fitting on tubular poles including bending the pipe to the required shape.
Description:- Supply, fixing, testing & commissioning of hot dip galvanized octagonal pole 5 mtr.
foundation (1:2:4) etc. the pole shall be complete with holes, anchor bolts, bottom plate etc. As per Tech spec/site requirement IS/IE rules of following type. Weight of the pole should not be less than
Description:- Supply, Erection, testing & commissioning of energy efficient LED street light luminary 60-70 Watt capacity with luminous efficacy greater than equal to 100 made from pressure die cast aluminum housing, toughened front glass cover, fitted with secondary optics, heat sink and integrated electronic driver for long life with IP 65/66 Protection suitable for working on 240 Volt, 50
pole/truss/ roof/ wall by fabrication by suitable clamp/ bracket made/pipe from G.I. flat of 40 x 6 mm approx. duly painted with nut, bolts and washers of 12 mm diameter as per site requirement. The connection shall be carried out through ISI marked, PVC insulated, flexible three-core copper wire from the existing ceiling rose /catenaries/ junction box as per site conditions. The connection cord shall be protected by suitable size of heavy duty flexible PVC conduit.
complete with all accessories. (LED luminaires should conform to min IP:66) including erection, testing, fixing & commissioning of LED street light fitting on pole/wall/structure.
Description:- Supply, Installation, Testing and Commissioning of 70 W High Bay Light Fitting with Pressure die cast aluminium alloy ACD12 housing (Heat sink) for effective thermal management, sturdiness & excellent corrosion resistant, Epoxy powder coated after phosphochromate treatment in metallic grey finish with high efficiency long life SMD LEDs with lumen efficacy of > 130 lm/W with
C to +55 degree C, operating voltage range 140 V - 270 V, Degree of Protection IP 65, Average life L70B50: 50000 hours, Integral Electronic driver with APFC, lower THD, Output Short Circuit Protection, Surge Voltage Protection, Over voltage protection & other safety test as per IS:15885 Part 2/Sec 13, CCT 5700 K, THD < 10, PF > 0.95 complete in all respect as required. NOTE - Fittings shall be inspected at manufacturer's premises by the RITES. Cost for the inspection shall be borne by the contractor.
fitting with complete accessories. The contractor shall provide the mounting arrangement for fittings as required at site and as per attached technical specification. Square
Foot Description:- Design, manufacture, display, installation of wall/hanging/floor mounting type LED illuminated signage/directional boards in flat/half elliptical/Parabolic/Triangular shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2.0 to 3.0 mm thickness. The text/graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics
pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement to be provided by the contractor. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4 to 8 Watt/sq. feet and with brightness more than ambient light. Suitable sized end caps of 1.5 mm thick SS-304 should be provided. Square
Foot 76 Description:- Fabrication, supply, fixing, testing and commissioning of LED glow sign boards, single sided of different sizes,
Description:- All work pertaining to Horizontal Directional drilling (HDD/ Boring and trenchless cable it includes supply transportation and insertion of self lubricated HDPE/ CI pipe and laying of cable in
be crossed. The depth of horizontal boring should be minimum 1.64 mtr. from rail flange/ road level. HDPE Pipe of IS: 4984/1995. Note: By using self lubricated HDPE pipe of 117 mm inner dia and 125 mm outer dia in the bore and the laying of cable in the bore under the track/road as per direction of Engineer in charge.
VARANASI DIVISION-ELECTRICAL/NORTH EASTERN RLY
Pipe with clamping arrangement. Cable laying work shall be governed by IS:1255/1983. (Cable & DWC Pipe will be supplied by Railway)
Description:- Laying of one number XLPE cable of 1100V grade of size exceeding 25 sqmm but not exceeding 400 sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as req. Cable laying work shall be governed by IS :1255/1983. (cable
a bedding of minimum 75 mm riddled soil or sand at the bottom of the trench, and covering it with additional riddled soil or sand of minimum 75 mm and protecting it by means of tiles, bricks or slabs. (II) Depth - The desired minimum depth of laying from ground surface to the top of cable is as follows: Low voltage and control cables -0.75 m, Cables at road crossings 1.00 m, Cables at railway level crossings (measured from bottom of sleepers to the top of pipe)- 1.00 m
Description:- Laying of one number additional XLPE cable of 1100V grade of size exceeding 25
formation including excavation, sand cushioning, protective covering and refilling the trench etc. as req. Cable laying work shall be governed by IS :1255/1983. (cable supplied by Railway).
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument.pdf
ATTACHMENT
Advancecorrectionslipno.11.pdf Advance correction slip no 11
ATTACHMENT
eBank Guarantee in Works Contract
ATTACHMENT
Explanatorynote.pdf
ATTACHMENT
Advancecorrectionslipno.11.pdf
ATTACHMENT
e-BankGuaranteee-BGinWorksContracts.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].