GE Narangi
GE Narangi C/O 99 APO Guwahati
PROVN OF ADDL POWER POINT, CEILING FANS AND WALL FANS IN BLDG NO T-1 AND T-2 AT NCC LINE, SPECIAL REPAIRS TO SECURITY LIGHTS AT ABOD AND RE-ROUTING / CONVERSION OF LT OH LINE TO UG CABLE WITH LT CONTROL PANEL AT MSL REGT UNDER GE NARANGI
2019_MES_296648_1
8505/NAR/E8
Open Tender
Civil Works
Works
180 days
GE Narangi
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Narangi
₹62,000
Yes
17 Jan 2020
11 Nov 2019
12 Dec 2019
11 Nov 2019
9 Dec 2019
25 Nov 2019
Amount
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade, IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top cover for one light/fan/exhaust fan/wall fan point controlled by one number one way 5 Amp switch complete all as specified and directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade, IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top cover for one 3 pin 5 Amp switch socket outlet on independent board controlled by one number one way 5 Amp switch complete all as specified and directed.
M & L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade, IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top cover for one 3 pin 5 Amp switch socket outlet on same board controlled by one number one way 5 Amp switch complete all as specified and directed.
M & L for point wiring with 4sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade, IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm cable (including connecting to earth dolly) laid/fixed in and including concealed in PVC rigid conduit on walls/ceiling, and also including sunk type pressed steel terminal box made out of galvanised iron sheet thickness not less than 1mm and 3 mm thick plastic laminated sheet top cover for one 3/6 pin 15 Amp switch socket combination outlet on independent board controlled by one number one way 15 Amp switch complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 5 Amps, 240 volt complete all as specified and directed.
S&F socket outlet, 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and directed.
S&F switch socket combination outlet, 5 pin, 2-in-1, 5 Amp, flush type complete all as specified and directed.
S&F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 15 Amp, flush type complete all as specified and directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F ceiling rose, surface bakelite, 65x50mm, three terminal complete all as specified and directed.
S&F single pole & neutral, DBs, 8 Ways, double door, protection class IP-43, suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with minimum 200 Amp rating copper bus bar 240V and grouted in wall with PCC, 1:2:4, type B1, using 20mm graded stone aggregate complete all as dierected. Make :- Legrand Cat No 6077 11 or equivalent model of make Siemens/Schnider
S&F factory made, sheet steel distribnution boards, vertical type, TPN, 4 Way, double door, fitted with copper bus bar, neutral links, blanking plates suitable for MCCB 125A, MCCB as incomer and MCBs, as outgoing complete all as specified and directed. Make:- Legrand Cat No 5077 40 or equivalent model of make Siemens/Schnider.
M&L for MCCB, four pole, 125A, 25KA with thermal adjusting 0.8 to 1.0, 415v, AC, complete all as specified and directed. Make:- Legrand Cat No 4200 56 or equivalent model of make Siemens/Schnider.
M&L for MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve, IS/IEC 60898-1 2002 marked, fixing in DBs complete all as specified and directed. Make :- Legrand Cat No 4086 09 to 4086 17 or equivalent model of make Siemens/Schnider
M&L for MCBs, SPN 40 to 63 Amps, 10 KA, 'C' curve, IS/IEC 60898-1 2002 marked, fixing in DBs complete all as specified and directed. Make :- Legrand Cat No 4086 18 to 4086 20 or equivalent model of make Siemens/Schnider
M&L for MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve, IS / IEC 60898-1 2002 marked, fixing in DBs complete all as specified and directed. Make :- Legrand Cat No 4085 87 to 4085 95 or equivalent model of make Siemens/Schnider.
M&L for sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / quarter as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and directed.
S&F energy efficient 5 star rated ceiling fan, 1200 mm sweep, single phase, 230/240 volts, AC and connecting up to and including provision of porcelain connector and flexible three core copper conductor of size 23/0.0076 from ceiling rose or connector to ceiling fan and testing on completion, complete all as specified and directed. Make : USHA Model Energia ISI 5 star or equivalent model in make Cromption /Bajaj/Orient.
S&F energy efficient 5 star rated wall fan, single phase, 2.0/240 V complete all as specified and directed. Make- Usha/Havells/Crompton
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying of cables, foundation for pole, etc and getting out in soft/loose soil complete all as specified and directed.
Returning filling in soil including spreading, levelling, watering and well ramming in layers n. exc 25cm thick complete all as specified and directed.
Removing excavated soil to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed.
Taking out old unserviceable underground cable including cable protection covers and GI pipe complete all as specified and directed. Note: Excavation will be measured and paid seperately.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sqmm 3 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 2 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 3 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE, Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sqmm 3.5 core complete all as specified and directed.
M&L for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, punning completed all as specified and directed. Note : Punned thickness will be measured and paid.
Laying only old serviceable bricks, obtained from item No 23 , laid dry in trenches for protection of underground cable, laid widthwise along the length of cable complete all as specified and directed.
M&L for sub class 'B' bricks, old size, locally available best quality, laid dry in trenches for protection of underground cable, laid widthwise along the length of cable complete all as specified and directed.
S&F GI tube light grade of size 40 mm bore dia conforming to IS 1239 of 1990 for protection of LT cable, laid in trenches or fixing on wall/pole etc. complete all as specified and directed
S&F GI tube light grade of size 50 mm bore dia conforming to IS 1239 of 1990 for protection of LT cable, laid in trenches or fixing on wall/pole etc. complete all as specified and directed
S&F GI tube light grade of size 80 mm bore dia conforming to IS 1239 of 1990 for protection of LT cable, laid in trenches or fixing on wall/pole etc. complete all as specified and directed
S&F in repairs, street light bracket, made to shape, out of GI pipe 40 mm bore medium grade, 2 metre length and fixed with mild steel clamps, nuts, bolts and washers on pole complete all as specified and directed.
M&L for manual boring of holes under road,pavement, hard standing where ordered and including inserting GI pipe 50 mm to 80 mm complete all as specified and directed . (Note : - GI pipe 50/80 mm will be measured & paid seperately.)
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to GI strip 32mmx6mmdia GI wire upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009.complete all as specified and directed.
Material & Labour for fixing in replacement LED street light luminaries of cap 80 watt, efficacy 100 lumens/watt,CCT 5700K,CRI>70,PF0.95 ,IP66,IK07,SP5KV internal & 10 KV SPD THD<10% 240 volt, pressure dia cast aluminium housing frame, heat resistant toughtened clear glass with frame complete with accessories , IP 66 protection, pre wired up to a terminal block and mounting attachment including taking out old unserviceable luminare complete all as specified and directed. Make- Havells Model ENDURAPEARLPLUSSL80WLED757SASYTOPC,or equivalent in Philips/Suriya/GE Note (i) The make of LED luminaries and driver must be same. (ii) 2 Years warranty is included in the unit rate.
Disconnection of both HT and LT connection cable of existing LT panel, shifting the panel to new location not exceeding 200 metre including necessary electrical connections along with aluminium thimbles / lugs, excavation and earthwork, PCC 1:2:4, typeB1 grouting etc complete all as specified and directed.
Dismantling unserviceable steel poles of any size including necessary excavation & earth work if required, demolition of foundation concrete complete all as specified and directed.
Supply, errecting & fixing in true vertical position, steel tubular swaged poles type 410 SP 31 (9.00 metres long) conforming to IS-1678 complete with cast iron base plates, finial taper plug, bolts, nuts & screws complete all as specified & directed.
Dismantling unserviceable/old ACSR conductors of any size from over head lines, poles by removing binding wire, service wire, cables complete all as specified and directed.
M&L for PCC 1:4:8, type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in foundation of stays and coping of poles including necessary form work complete all as specified and directed.
M/s Dhani Enterprise
J K CONSTRUCTION
M/s KRISHNA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .