| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC 2 NO SIDDHESWARI LANE KANCHRAPARA 24 PARGANAS N WEST BENGAL 743145 | KANCHRAPARA | NORTH 24 PARGANAS | WEST BENGAL | 743145 | ₹5.2 L | L1 | Accepted-AOC AOC_Issued |
| 2 | L2₹6.3 LRejected-Finance 24 C GOABAGAN LANE KOLKATA 700006 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700006 | ₹6.3 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹6.4 LRejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹6.4 L | L3 | Rejected-Finance that the bid is not L1 |
| 4 | L4₹7.0 LRejected-Finance 46 S P MUKHERJEE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹7.0 L | L4 | Rejected-Finance that the bid is not L1 |
| 5 | L5₹9.4 LRejected-Finance F IA 24 4210 CO JAYKRISHNAPUR P O BEGAMPUR DIST HOOGHLY | BEGAMPUR | HOOGHLY | WEST BENGAL | ₹9.4 L | L5 | Rejected-Finance that the bid is not L1 |
| Sl No | Description | Qty | Unit | C. CHOWDHURY AND CO L4 | ALPHA ELECTRICALS L2 | S. A. ENTERPRISE L3 | SUNLIGHT CONSTRUCTION L1 | P. M. COOLING AND ENGINEERING CO L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismentling the existing E.I. work / cables (as per site requirement) etc. after dismantling all cable glands, terminations, and relaying the dismantalled cables as per requirement (to facilitate cable glanding & termination) by Co's own tools & tackles by maintaining normalcy as far as possible and keep dismantalled materials in respective Sectional Store / place within compound of KMCH as per direction of EIC all complete. (Shut Down Provision for Time & Date as per Permission alloted from the Authority End.) | 1 | It. | 25,000 ₹25,000 | 2,500 ₹2,500 | 3,500 ₹3,500 | 3,000 ₹3,000 | 1,000 ₹1,000 |
| 2.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Mk.-Polycab/RR/KEI)) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment,painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] as to GS vide PWD schedule page no- E15/Item-5.
b. Avg run 12 mtr | 10 | Pts. | 1,200 ₹12,000 | 1,574 ₹15,740 | 1,650 ₹16,500 | 1,558 ₹15,580 | 1,500 ₹15,000 |
| 3.00 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single
core stranded 'FR' PVC insulated & unsheathed copper wire
Mk.-Polycab/RR/KEI) in 20mm size PVC rigid conduit 'FR'
(Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm)
single core stranded 'FR' PVC insulated & unsheathed copper
wire as ECC, to 5A 3 pin flush type plug socket & Piano Key
type switch fixed on MS CRC sheet metal (16 SWG) switch
board cum JB on wall incl. bakelite/Perspex (wall matching
color) top cover 3 mm thick and incl. painting the MS box and
mending good the damages to original finish (P-E-15/Item-4)
On board | 2 | Nos. | 195 ₹390 | 75 ₹150 | 80 ₹160 | 75 ₹150 | 1,343 ₹2,686 |
| 4.00 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles (a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire (PWD Schedule page-E-3/Item-6) | 50 | Mtrs. | 55 ₹2,750 | 71 ₹3,550 | 75 ₹3,750 | 86 ₹4,300 | 205 ₹10,250 |
| 5.00 | Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles (b)25 mm dia 3 mm thick polythene pipe without earth continuity wire. (PWD Schedule page -E-3/Item -7) | 10 | Mtrs. | 55 ₹550 | 87 ₹870 | 95 ₹950 | 89 ₹890 | 210 ₹2,100 |
| 6.00 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
(PWD Schedule Page- E-16/Item-7)
20mm dia. | 30 | Mtrs. | 35 ₹1,050 | 58 ₹1,740 | 68 ₹2,040 | 60 ₹1,800 | 175 ₹5,250 |
| 7.00 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (KEI/Polycab/RR Kabel) of the following sizes in the prelaid polythene pipe/Rigid pipe and by the prelaid GI fish wire and making necy. connection as required as to GS. vide PWD Schedule page E9/ Item -1.
2 x 1.5 sqmm + 1 x 1.5sqmm Single core copper wire | 60 | Mtrs. | 135 ₹8,100 | 54 ₹3,240 | 75 ₹4,500 | 66 ₹3,960 | 95 ₹5,700 |
| 7.10 | 2 x 2.5 sqmm + 1 x 1.5sqmm single core copper wire. (PP) | 360 | Mtrs. | 45 ₹16,200 | 94 ₹33,840 | 82 ₹29,520 | 74 ₹26,640 | 103 ₹37,080 |
| 7.20 | 2x4 + 1x2.5 Sq.mm,1.1 KV single core copper wire (For AC machine) | 110 | Mtrs. | 165 ₹18,150 | 127 ₹13,970 | 115 ₹12,650 | 107 ₹11,770 | 190 ₹20,900 |
| 7.30 | 2x6 + 1x4 Sq.mm 1.1KV single core copper wire | 90 | Mtrs. | 165 ₹14,850 | 157 ₹14,130 | 168 ₹15,120 | 157 ₹14,130 | 285 ₹25,650 |
Tender Value
Refer Docs
EMD Value
₹11,000
Closing Date
29 Aug 2022, 1:00 pmClosed
EE II KNHED PW Dte
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
SITC of Concealed Split AC machines in Biochemistry Room at 2nd Floor of RIO Bldg Kolkata Electrical Installation allied AC work
2022_PWDE_395669_1
WBPWD/EEII/KNHED/NIQ-37/22-23
Open Tender
ELECTRICAL WORKS ORG
30 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,000
6 May 2026
17 Aug 2022
31 Aug 2022
19 Aug 2022
29 Aug 2022
19 Aug 2022
Amount
Dismentling the existing E.I. work / cables (as per site requirement) etc. after dismantling all cable glands, terminations, and relaying the dismantalled cables as per requirement (to facilitate cable glanding & termination) by Co's own tools & tackles by maintaining normalcy as far as possible and keep dismantalled materials in respective Sectional Store / place within compound of KMCH as per direction of EIC all complete. (Shut Down Provision for Time & Date as per Permission alloted from the Authority End.)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Mk.-Polycab/RR/KEI)) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65mm inspection box, making earthing attachment,painting the MS box and mending good the damages to original finish [only PVC Rigid Conduit on ceiling and remaining portion concealed] as to GS vide PWD schedule page no- E15/Item-5. b. Avg run 12 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire Mk.-Polycab/RR/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish (P-E-15/Item-4) On board
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles (a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire (PWD Schedule page-E-3/Item-6)
Cutting Channel of size (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles (b)25 mm dia 3 mm thick polythene pipe without earth continuity wire. (PWD Schedule page -E-3/Item -7)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works (PWD Schedule Page- E-16/Item-7) 20mm dia.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (KEI/Polycab/RR Kabel) of the following sizes in the prelaid polythene pipe/Rigid pipe and by the prelaid GI fish wire and making necy. connection as required as to GS. vide PWD Schedule page E9/ Item -1. 2 x 1.5 sqmm + 1 x 1.5sqmm Single core copper wire
2 x 2.5 sqmm + 1 x 1.5sqmm single core copper wire. (PP)
2x4 + 1x2.5 Sq.mm,1.1 KV single core copper wire (For AC machine)
2x6 + 1x4 Sq.mm 1.1KV single core copper wire
Plugs & Socket :- Supply & Fixing 240 V, 2 no 6A, plug socket with separate 2 no 6A Piano key type switch (Brand approved by EIC) on sheet metal switch board on wall incl. S & F 175x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as to GS.
a. Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor) on sheet metal switch board on wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as to GS. (Vide page no E 6 Item no 22)
b.Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Legrand) on sheet metal switch board embedded in wall incl. S&F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as to GS. Vide page no E 7 Item no 26
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Mk.-Legrand/Schneider/NorthWest), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire as to GS. (PWD Schedule page - E-17/Item -
S & F OF BDB,PDB,VTPN ETC. Supplying and fixing 6-way,double door Horizontal TPN MCB Distribution board (Make- Legrand/L & T ) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (as per PWD Schedule page No-D10/Item-14)
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment as to GS (Page -D12/Item-16) 6-way HTPN DB
Supplying and fixing 240V/415V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (PWD Schedule Page No-D-6/ Item-7) (a) 6-32A SP MCB (Mk.-Legrand/L & T/SIEMENS)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection (PWD Schedule page No- D-5/Item-D-6) (a) 63A FP Isolator (Mk.-Legrand/L & T/SIEMENS)
S & D of cable :- S & D of 4- core 25 sqmm Al. armoured XLPE cable ( Mk.-Havells/KEI/Polycab/ Currency)
Laying of Cables :- a. Laying of cable from 25 sq.mm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as ecy., mending good damages and painting as to GS vide page no- F1/Item-2c.
Laying of cable as below, on existing Cable Tray and binding with suitable size GI wire.as to GS vide page no- F-3/Item-6. (a) upto 50 Sq.mm
SUPPLY OF LIGHT FITTINGS :- S&D 4 feet long single commercial LED type light (1x18w) LED Tube lamp (MK Philips, master LED 18W/Crompton/ Wipro / Jaquar - as per choice of EIC)
S&D 4 feet long single commercial LED type light fittings (Mk. Philips, Cat no TMC-501 P 1x T-TLD 20 W/Crompton/ Wipro / Jaquar - as per choice of EIC)
Fixing of light fittings :- Fixing only fluo. Luminaries single / double from ceiling by 'L' clamp incl. 2 nos 2' long down rod and connecting the length with 3x1.5 sq.mm PVC insulated copper wire as required incl. fixing of lamp. (For new & existing light fittings)
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
S & D of fans :-- S & D 450mm (18"), 250V, high flow (air Delivery-4500CFM ) 1400 RPM non-oscillating type metal body wall bracket fan with inbuilt regulator, double ball bearing, integrally cast LM 6 impellar wall bracket fan to be fixed on HW block 1'' thick as per direction of EIC.(make- EPC, Model-Tempest)
Fixing of fans :- Lowering and refixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required.
Fixing 18" WB Fan on HW Board (sie 12" x 8"x1'') to be fixed on wall with suitable size of fastner, nut-bolts etc..
Miscellaneous Item :- a. Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. (a) With 25x25x3mm angle iron support,size-300x50x1.25mm(18 SWG) (PWD Schedule page -D 14/Item- 34a)
b. Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support size-300x50x1.25mm (P-D-15/Item-34b)
Supplying & Fixing 4-module GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works as to GS vide page -E-17/Item-2.
b. Supplying & Fixing 2-module GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works as to GS vide page -E-17/Item-1.
S & F of 21A,230V AC motor starter with AMP/Volt/Time check. (Mk.- Electron, OLP-3) in the existing 4 module GI Box concealed in wall .
(i)S&F compression type cable gland complete with brass Gland, rubber rings for dust & moisture proof entry for Following sizes, PVC/A cable incl. finishing end bysoderless socket by crimping method as per GS. (page-F4,F5,Item-7,8) A. for 4 core 25 sqmm.
Supply and installation of timer in (2+10) way Double door SPN DB (L & T) providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires. The box having the following accessories. (a) 25A DP MCB (Legrand make.)-1 No. (b)Digital Time switch (ABB make, ) - 1 No. (c) 3-pole single phase power contactor, (Type-MNX 25, L & T make/ABB )- 1 No. (d)Side mounting Add-on aux. contact block (1NO+1 NC) ( L & T make cat no.CS94202)-1 no. (e) 25A capacity terminal block (Elmex)- 1 No. (f) Indicator Lamp (ESBEE make)- 2 Nos. (g) Toggle switch (ON-OFF-ON)- 1 No. (h) Steel Key Lock – 1 No.
SITC of AC machine:- Concealed Split AC a. Supply & delivery 2.0 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with 1 No. Rotary compressor, 1 no. IDU of rated power supply - 230V, 1ph, 50Hz., 1 no. ODU of rated power supply - 230V, 1ph, 50Hz. Air-flow/per IDU :- 800CFM of R410A Refrigerant gas . (Make: Voltas/ Blue Star / Carrier/Daikin/ Mitsubishi-Electric)
Erection, testing and commissioning charges for the above said 2.0 TR concealed Split AC. The indoor (IDU) & Outdoor (ODU) unit must be supported by structure made of 25 X 25 X 5 mm angle and tie rod incl. necy. painting & as per direction & satisfaction of EIC.
a. Copper Refrigeration pipe line for Liquid Line hard drawn Cu piping (1/4" OD with 0.6 mm thick) with necy supports & brackets as per direction of EIC.
b. Copper Refrigeration pipe line for Suction Line hard drawn Cu piping (5/8" OD with 0.7mm thick) with necy supports & brackets as per direction of EIC.
Supply & Fixing of Nitrile Rubber tube insulation ([Make: Armacell/K-flex/A-flex]) of 9 mm thick on Suction & Liquid Line Copper Pipe.
S & laying Control Cable from Condensing Unit to Control Panel, (a)3 Core 2.5sq. mm. Communication Cable (Mk. Finolex / KEI/Polycab)
Supply and fixing of PVC water carrying drain pipe of 25mm dia for draining water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape , high quality sealing gum etc. as required. All these arrangment for fixing must be arranged by the agency itself as per direction of EIC.
Supply and fixing flexible double canvass connection for concealed split air-conditioners.
Supply and fixing of Al powder coated continuous Grill
Charges for Scaffolding arrangement including lifting for outdoor & indoor units.
Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al./MS frame work with GI brackets ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles,cleats and stainless steel screws forming grooves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant) labour scaffolding and all other incidental charges e.g. VAT,labour cess etc. complete in all respect as per specification and direction of Engineer -in- charge.(Mode of payment is on finished surface areaof ACP) a) 3mm thick (0.25mm Al. + 2.5mm LDPE + 0.25mm AL PVDF coating) (Mk.- Aludecor)
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Rate should be quotated including all taxes and duties)
Defect Labilities period for 02 year from the date of completion of work. (Rate should be quotated including all taxes and duties)
ALPHA ELECTRICALS
S. A. ENTERPRISE
C. CHOWDHURY AND CO
P. M. COOLING AND ENGINEERING CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.41 MB
2911_.pdf
Tender Documents • 0.50 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_776308.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid