Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC The quoted amount of L1 bidder is found competitive and reasonable overall, hence accepted | |
| 2 | L2₹14.7 L+₹2.7 L (22.2%)Rejected-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L2 | Rejected-AOC Being not the L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
24 Jan 2024, 6:00 pmClosed
Garrison Engineer, St.Thomas Mount
Garrison Engineer, St.Thomas Mount, Old MH Complex, Rudra Road, Chennai-600 016
REPAIRS/MAINT OF REFRIGERATORS, WATER COOLERS, WINDOW, SPLIT AC, PACKAGE AC ETC AT OTA, MH AND PALLAVARAM UNDER GE STM
2023_MES_634101_1
8388-REPAIRS/MAINT OF REFRIGERATORS, WATER COOLERS
Open Tender
Miscellaneous Works
Item Rate
270 days
GE STM
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer, St.Thomas Mount
₹30,000
Yes
21 Feb 2024
22 Dec 2023
1 Feb 2024
22 Dec 2023
24 Jan 2024
5 Jan 2024
22 Dec 2023 - 30 Dec 2023
Amount
Taking down unserviceable items Supply and replacing with new items of following for water cooler 40/40 ltrs, 40/80 ltrs and 150/150 ltrs capacity including testing and commissioning etc complete all as specified and directed.
(a) Thermostat Make : Indfoss/Danfoss/Ranutol/Electrolex
(b) Capacitor 36MFD Make : Keil/Keltron/saha/sarold
(c) Capacitor 10 MFD Make : Keil/Keltron/saha/sarold
(d) Over load protector. Make : Ranutol/Arvind/Shriram
(e) Fan motor capacitor 4/6MFD Make : Keil/Keltron/saha/sarold.
(f) Condenser fan motor 1/32 HP. Make : Frogmaster/Aue/Himson
(g) Condenser fan motor 1/16HP. Make : Frogmaster/Aue/Himson
(h) Fan blade assembly.
(i) PVC drain hose pipe size 32 mm dia
(j) Drain stainless steel tray with drain elbow and connector
(k) Top lid gasket
(l) PVC connections 15mm size with PTMT nuts of length 450mm
(m) Gate valve brass screwed both ends of size 15mm bore.
(n) Push cock brass chromium plated size 15mm.
(o) Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed of size 15mm.
M&L for servicing the water coolers of any make and models in situ, comprising cleaning of condensers and storage tanks with cleansing agent such as liquid detergent, lubricating the system with grease or oil as required tightening the bolts nuts etc complete all as specified and as directed.
(a) 40/80 ltrs capacity
(b) 150/150 ltrs capacity
All as per item No. 1, but for refrigerator 165 to 310 ltrs capacity.
(a) Door magnetic gasket
(b) Freezer door
(c) door lock with key
(d) Light switch
(e) PVC ice tray (Each set of two nos)
(f) Cooling coil
(g) Condenser coil
(h) Bulb pin/screw type 10/15watt. Make : Philips
(i) Relay box type. Make : Ranutol/Arvind/Shriram
(j) Relay 1/6HP Make : Ranutol/Arvind/Shriram
(k) Over load protector 1/6HP. Make : Ranutol/Arvind/Shriram.
(l) Thermostat defrosting type Make : Indofoss/Arvind/Shriram
(m) Defrost tray for Refrigerator Capacity 165 to 330 Ltr Make Suitable for Whirlpool/LG/Samsung/Godrej )
All as per item no 1 but for Window / split type AC 1.5/2.0 Ton capacity
(a) Capacitor 50-60 MFD , Make: Keil/Keltron/saha/sarold
(b) Overload protector (OLP). Make : Ranutol/Arvind/Shriram.
(c) Starting relay assembly . Ranutol/Arvind/Shriram
(d) Electronic PCB Board for non inverter AC
(e) Electronic PCB Board for inverter AC
(f) Wiring kit complete
(g) Fan motor capacitor 2-5 MFD. Make: Keil/Keltron/saha/sarold
(h) Outdoor unit Fan motor . Make : Frogmaster/Aue/Himson
(i) Condenser Fan blade metal or plastic
(j) Indoor unit blower motor.
(k) Indoor unit blower
(l) Cooling coil copper.
(m) Condenser coil copper.
(n) Standard outer cover
(0) Front panel with grill
(p) Copper pipe for suction and discharge line
(q) Drain pipe
(r) Thermostat Switch (Make : Sriram/Ranutrol/Arvind)
(s) Air filter
(t) Complete indoor unit set for split AC as per existing make.
(u) Complete outdoor unit set for split AC without compressor and fan motor as per existing make.
(v) Capillary and filter
(w) Suction valve for split AC
(x) Discharge valve for split AC
(y) Outdoor unit wall stand
(z) Regulator Knob Suitable for 1.5 TR/ 2.0 TR capacity window AC
(aa) Remote control including battery for window / Split AC Cap 1.5/2.0 TR of make as per site requirement and replace of Old one complete all as specified and as directed(Make -LG/ Bluer Star/ Voltas)
(ac) Foam sheet of size 180 cmX 90 cm X 15mm thick complete all as specified and as directed
(ad) Hexagonal Flare nut made of Brass
(ae) Union Couple made of Brass
(af) inverter type PCB circuit plate with sensors suitable for Outdoor unit of Split Acs of any Capacity
(ag) inverter type PCB circuit plate with sensors suitable for Indoor unit of Split Acs of any Capacity
(ah) Swing Motor suitable for indoor unit of inverter type Split Acs of any Capacity
Dismantling the unserviceable sealed compressor unit from 1.5 TR Window AC / Split AC of any make and model, supply and fixing new sealed compressor unit including, connecting up complete and oil charging, etc., all as specified and directed Note: Refrigerant gas charged shall be measured under relevant item of Sch 'A' Make : Tecumseh/Hitachi/Panasonic/Highly.
All as per item no 5 above but for Window /Split AC 2.0 TR capacity.
All as per item no 5 above but for Water cooler 40/80 ltrs capacity.
All as per item no 5 above but for Water cooler 150/150 ltrs capacity.
All as per item no 5 above but for Refrigerator 165 ltrs capacity.
All as per item no 5 above but for Refrigerator 286 to 310 ltrs capacity.
All as per item no 5 above but for Deep freezer 300 to 425 ltrs capacity.
M&L for pressure testing the Window ACs 1.5 Ton, with nitrogen gas after flushing out the system free from refrigerant checking for leakages if any in the refrigerant system making good the leaking spots with necessary brazing/welding, ensuring leak proof system charging the refrigerant gas including replacing the strainer & capillary etc with new items and testing for satisfactory performance complete all as specified and as directed Note: Refrigerant gas charged shall be measured under relevant item of Sch 'A'
All as per item no 12 above but for Split AC 1.5/2.0 TR capacity
All as per item no 12 above but for Water cooler 40/80 ltrs & 150 ltrs capacity
Leak testing and gas charging the system after flushing, vaccumissing and dehydration as per standard practice including the cost of refrigerant, testing and detecting leakage in the system and arresting the same for 165 to 310 ltrs capacity of the refrigerator
Dismantling of existing repairable Refrigerators of any make and from its position after disconnecting electric connections transporting from site to Contractor workshop for carrying out repairs and renewal/ replacement of parts, reassembling and transporting back to the site including installation of the same on the Same Location and making electric connection etc complete all as specified and as directed by Engr-In-Charge. Note:- parts renewed shall be measured and paid separately
Supply and filling Refrigerant gas R-134 A in Refrigerators/deep Freezers /Water Coolers of any Capacity, Model and make including detecting the leakage Gas at any Location and rectifying the defect to stop the Leakage by Gas welding or by other means including cutting and Brazing of copper tubes testing and commissioning complete in satisfactory working condition Make: Melfron/Floron/Refron)
Material and Labour for cleaning filter and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out and fixing back its original position combing the fins for Window type Air conditioner 1.5 Ton/2.0Ton Capacity complete all as specified and as directed.
Material and Labour for cleaning filter and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out and fixing back its original position combing the fins for Split type Air conditioner 1.5 Ton/2.0Ton Capacity complete all as specified and as directed.
Disconnection and removing of serviceable window type AC of capacity 1.5TR/2.0TR of any make / Model along with Stabilizer from its position and fixing the same in other Location including all other fixing accessories and testing complete all as specified and as directed
Disconnection and removing of serviceable Split type AC of capacity 1.5TR/2.0TR of any make / Model along with Stabilizer from its position and fixing the same in other Location including all other fixing accessories and testing complete all as specified and as directed
Disconnecting and taking out deep freezer of capacity 300 litre to 425 litre of any make, cleaning the gas system with CTC / nitrogen and charging the refrigerant including the cost of refrigerant with anti moist substance and replacement of capillary tube and strainer including rectification of leakage lin the system and refixing in the same position complete all as specified and directed.
Material and Labour for detecting of leakages of gases in water cooler , Refrigerator of any capacity at any Loaction and rectifying the defect to stop the Leakage by Gas welding or by other means including cutting and Brazing of copper tubes testing and commissioning complete in satisfactory working condition
Taking down existing worn out winding from fan motor , rewinding the blower fan motor of window / Split AC capacity of 1.5 TR with super enamelled copper wire of suitable gauge capacity, bringing back to worksite and refixing the same on its position including replacement of bushes all as directed.
All as per item no 24 above but for Water cooler 40/80 and 150/150 ltrs capacity.
Taking out of all rusted portion of Window AC ,making good the same with new MS sheet of approved gauge /existing gauge including iron supports by tinkering/welding and positioning back in original place including two anticorrosive black paint over a coat of primer all as specified as directed.
All as per item no 26 above but for Water cooler 40/80 & 150/150 ltrs capacity.
All as per item no 26 above but for Refrigerator 165 to 310 ltrs capacity.
Material and labour for applying two coats of anti corrosive black paint upto 15 cm height of old steel surfaces from the base all round including legs for inside of water cooler of capacity 150 ltrs all as directed
All as per item no 29 above but water cooler capacity 40/80 ltr
Supply and filling of gas R-22/R-410A/R-32/R-134A in window type/ Split Type AC Unit of Capacity 1.5/ 2 TR Deep Freezer, Refrigerator , Water Cooler of any Capacity Complete all as specified and as directed. Make: Melfron/Floron/Refron
Supply and fix new MS bottom base for fan motor of any given make for window type AC 1.5 tonne including dismantling the old unserviceable fan motor base all as directed
Supply and fix MS jointing plate for condenser / cooling coil housing for window AC of any make for 1.5 Ton capacity including dismantling the old unserviceable jointing plate all as directed.
Supply and fix ply wood 6mm thick , no of ply 6, grade BWR, type BB at the window AC places as fixed with nails etc and when the AC removed from site as a safety measure all as directed
Dismantling the transformer from the stabilizers of following capacity and removing the old / burnt transformer and replaced with new transformer as per existing make.
Supply only of following spare parts as per existing make for 1 KVA to 2 KVA capacity stabilizers
(a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
Supply only of following spare parts as per existing make for 4 KVA to 5 KVA capacity stabilizers
(a) Relay set ( set of two )
(b) PCB ( Printed circuit board)
(c) Trigger Transformer of 500 MA to 750 MA Capacity suitable for 5 KVA voltage Stabilizer , 1 ph, 230 Volts
(d) Relay of 30 Ampere capacity suitable for 5 KVA Voltage stabilizer , 1 ph, 230 Volts
M&L for rewinding of Main Transformer of 5 KVA Capacity voltage stabilizer with super enamelled copper wire of suitable size with including necessary varnishing and heating complete all as specified and as directed
COLD STORAGE/PACKAGE TYPE / WALK IN COOLER PLANTS OF CAPACITY 5/5.5 TR.
Material and labour for cleaning filter, drain out pipe and servicing the condenser & cooling coil by spraying detergent water washing and caustic soda washing thoroughly cleaning and drying out including combing the fins for cold storage unit 5/5.5TR all as specified and as directed
M&L for descaling of condenser unit 5.5 TR by circulating dilute hydrochloric acid solution and cleaning the tubes with wire brush by removing the side cover till the tubes are thoroughly cleaned and re-circulating the fresh water after fixing the side cover with necessary gasket and bolt and nuts.
Labour only for attending breakdown of cold storage/mortuary cabinet /5.5 TR package type AC and make it functional all as directed. Note : Spares shall be measured and paid separately.
Removing the defective sealed type compressor from the of cold storage AC plant/package type AC plant, supply and fix new sealed compressor including reconnecting and testing and commissioning at site all a specified and directed. Make : Tecumseh/Hitachi/Panasonic/Highly.
Testing leak in system ,arresting leak, vacuuming the system, flush out the system by nitrogen gas at 350 psi vacuuming and testing and commissioning complete for 5/5.5TR capacity walk in cooler / cold storage / package type plants all as specified and directed. Note: Refrigerant gas charged shall be measured under relevant item of Sch 'A'
Supply and fix in replacement of electronic timer series ETR-350, 240v AC 50/60 HZ Contact 240v AC/ 28VDC 5 A (Resistive) Star-Delta 3.30 second and 6-60 second cat No. Y 847D-1 Make : L & T or equivalent
Supply and fix in replacement of single phase preventer. Minilac or equivalent.
Supply and fix in replacement of orifice No 4 as per existing make for walk in cooler all as directed
Supply and fix in replacement of expansion valve make : Sporlan or equivalent for cold storage plant 5/ 5.5TR
Supply and fix in replacement of condenser fan motor with blower set blade of 5 / 5.5TR capacity for cold storage all as directed. Frogmaster/Aue/Himson
Supply and fix in replacement of LP and HP Cut out make : Indfoss or equivalent for cold storage plant 5 / 5.5TR
Supply and fix in replacement of for gasket entire door of walk in cooler capacity of 5.5 TR etc complete all as speci fied and as directed.
Supply and fix in replacement of evaporator fan motor for walk in cooler capacity 5.5 TR complete all as specified and as directed. Make : Frogmaster/Aue/Himson
Supply and fix in replacement of pillar block bearing for AHU blower motor of package type 5.5 TR capacity air conditioning all as directed. Make : SKF/ABC/TATA.
Supply and fix in replacement of liquid line filters, driers Type IDK 083 as per existing make of package type 5.5 TR capacity air conditioning all as directed
Supply and fix in replacement of 'V' belt for blower of package type AC plant Cat Part No Fenner A 32
Supply and fix in replacement of fan blade as per existing make heavy duty suitable for package type AC plant 5.5 TR
Supply and fix in replacement of suction valve unit for cold storage plant 5 / 5.5TR
Supply and fix in replacement of discharge valve unit as per existing make for cold storage plant 5/ 5.5TR
Supply and fix in replacement of evaporator coil for fan motor complete with blade set suitable for cold storage plant 5 / 5.5TR. Make : Frogmaster/Aue/Himson
Supply and fix in replacement of service valve Model scroll type Unit as per existing make for cold storage plant 5/ 5.5TR
Supply and fix in replacement of copper pipe 5/8" suitable for 3 ton capacity sealed compressor of cold storage plant of 5.5TR
Supply and fix in replacement of condenser fan motor Make: GE or equivalent for package type AC plant 5 / 5.5TR
Supply and fix in replacement of thermostat for cold storage plant 5/ 5.5TR
Supply and fix in replacement of Air break (Power) contactor 3 TF 3200-OA AC 11 rating -16 Amps capacity Make : SIEMENS or equivalent
Material and labour for rewiring of control panel complete, providing inter lock system and serving of electronic PCB Board and display for package type AC plant of Make - Blue star of capacity 5 / 5.5TR
Supply and fix in replacement of drier core for package type A/C plant 5 / 5.5TR. Make Danfoss
Supply and fix in replacement of starting relay 30 W of range 3.5 to 5 Amps. Make: Siemens or equivalent
Supply and fix in replacement of solenoid valve and cut-out switch with N2 testing for cold storage / package type 5/ 5.5 TR capacity air conditioning all as directed. Make : Danfoss or equivalent
Supply and fix in replacement of Temperature controller assemble for cold storage plant 5.5 TR as per existing make.
Supply and fix in replacement of MCB SP 06-32 Amps "C" Series. Make Standard/Havells/Indoasian
Supply and fix in replacement of water flow switches as per existing make of package type 5.5 TR capacity air conditioning etc complete all as specified and as directed.
Supply and fix in replacement of dryer as per existing make 5/8 for walk in cooler capacity 5.5 TR complete all as specified
Supply and fix in replacement of electronic control unit with display board for 5.5 TR package type AC and make the system functional all as directed.
Supply and fix in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes as shown of size 65 mm dia.
Supply and fix in replacement of MS flange having holes suitable for 65MM sizes of pipe including jointing material such as rubber gasket bolt units and washers etc in place of unserviceable all as directed
M&L for rolled mild steel work in joist, channel, angle, or tee sections, fixed independently, without connecting plates etc., cut to within 20mm of the length indicated, quality confirming to GDE Fe-410-S for cooling tower repair and pump mounting base complete all as specified and as directed.
Painting of cooling tower inner side and outer side one coating of Red oxide two coating of existing colour of synthetic enamel paint after cleaning and scrubbing of capacity 22TR.
Supply and fix in replacement of PVC honey comb fills (drift eliminators) suitable size of 22 TR plant all as specified and directed.
Servicing of LT AC plant panel board of any size including connected starter panels and wirings, cleaning of panel board internally and externally, tightening of all screws and nut & bolts, replacing of minor parts like screws, washers, lugs etc, checking of serviceability of all switch gears and replace the following items as required :-
Supply and fix in replacement of electronic timer 240v, 50 Hz, 3-30 sec for star delta starter.
Supply and fix in replacement of MNX 18 W contactor assy AC - 3 415 V 16 Amps .
Supply and fix in replacement of contactor combination (Relay) 2 - No + 2 NC 415 Volts upto 40A Amps
Supply and fix in replacement of MCB TPN 20A Amps 415 volts with rupturing capacity 10 KA
Dismantling the mono block pump set 3 HP with motor rewinding the motor with suitable enamelled copper wire, varnishing, providing sleeves and insulating materials including servicing of pump, repairing the defective spares and assembling and testing
Dismantling the induction motor for AHU rewinding the motor with suitable enamelled copper wire, varnishing, providing sleeves and insulating materials including repairing the defective spares and assembling and testing
Painting of mono block pump set with motor of any capacity with two coats of synthetic enamel paint after cleaning and scrubbing.
S&F in replacement of butterfly valve 65mm dia with handle
S&F in replacement of air filter suitable for 5.5 TR package tye AC with frame all as specified and directed.
Painting of condenser pipe line inlet and outlet( length upto cooling tower basin) and chiller pump pipe line inlet and outlet(length up to plant room wall) one coating of existing colour of synthetic enamel paint after cleaning and scrubbing including marking and numbering complete all as specified and directed .
Dismantling and fixing the cooling tower service panel and drain out complete water cleaning of honey comb fills, drift eliminators, Nozzles by caustic soda and wire brush and cleaning the cooling tower tank and removed all algae from the basin and removing sediments from the GI pipes and cleaning the sump suction filter of capacity 22 TR
Servicing of Air Curtain of size 6' (Make : Almonard), cleaning internally and externally, tightening of all screws and nut & bolts, replacing of minor parts like screws, washers, etc, including replacement of bush, checking of serviceability of all components and replace the following items as required :- (Note : Service shall be done through authorised service provider only)
Supply only of following spare parts for Air Curtain of size 6' (Make : Almonard)
(a) Supply only motor single phase 4 pole, 1/5 HP.
(b) Supply only replace Impeller metal bush.
( c) Supply only replace Impeller pin bush.
(d) Supply only replace Bush bearing set.
( e) Supply only replace AS-3 smart Impeller.
General Notes : 1. Repairs/ services required shall be notified as complaints at complaint cell of AGE E/M MOUNT, GE STM Chennai. Complaints shall be attended in all working days, holidays including sundays. 2. The contractor shall deploy one Ref Mech/ technician and one helper on all days to report in the complaint cell by 0900 Hrs to receive the complaints and without any extra claim and the same is inclusive of quoted amount. 3. Complaint slip should be submitted back in the complaint cell by 1700 Hrs duly rectified the defect. 4. The rate quoted is deemed to include for receiving complaints, all materials and labour required for rectification of complaints and closing the complaints to the satisfaction of Engr-in-Charge/GE.
RK ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .