Garrison Engineer (East) Prayagraj
Stanley Road, Teliyarganj, Prayagraj
Repair/replacement of wiring and connected items for MD and OTM Accn under GE (East) Prayagraj.
2023_MES_610503_1
8655/E8
Open Tender
Civil Works
Item Rate
270 days
Prayagraj
As per NIT
8 documents required · 8 mandatory
₹500
GE (East) Prayagraj
₹90,000
Yes
20 Oct 2023
24 Jul 2023
30 Aug 2023
24 Jul 2023
28 Aug 2023
14 Aug 2023
Amount
Taking down carefully copper/ aluminium point wiring (light,fan,socket or power) of any type and any size complete including fixture and fitting such as switches, ceiling roses, pendant, regulators, sockets, light fittings etc of any type, size and description (light, fan, sockets and socket outlets etc) including removal of battens conduit/casing caping, pipes, plug sockets, socket outlets, switches, shades, ceiling roses, light fittings etc. complete and keeping in safe custody for resuse or for issue on credit to contractor as directed by Engr in Charge. and making good disturbed surface of walls/floors etc. to match with existing complete all as specified and directed.
Taking down main switches, distribution boards and cut outs etc. of any type and capacity and removing the same from site and keeping in safe custody for resuse issue on credit to contractor as directed by Engr-in- Charge and making good the disturbed surface/portion of walls complete all as specified and directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/ surface conduit/ casing caping complete with its all accessories complete all as specified and directed.
M&L for point wiring complete using PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including rigid PVC conduit 'medium grade' ISI marked (not less than 20 mm dia) including all conduit accessories for concealed wiring for one light/fan/bell/exhaust fan point controlled by one, one way switch, including concealed pressed steel terminal box of required size (not less than 1.6 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer), with 3.0 mm thick top cover of plastic laminated sheet of required colour (for mounting switch, sockets, fan regulator etc) including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site& including chases cutting & making good disturbed surface & applying finishes to match existing surface complete all as specified and directed.
Ditto as per above item No. 4 but for one light point controlled by two, two way switches.
Ditto as per above item No. 4 but for 3pin ,5amp socket out let on the same board with other sutable using 2.5 Sq mm cable multistranded copper conductor & 2.5 Sq mm cable FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire.
Ditto as per above item No. 4 but for one 3 pin, 5amp socket out let on independent board using 2.5 Sq mm cable multistranded copper conductor & 2.5 Sq mm cable FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire.
Ditto as per above item No. 4 but for one 3 pin , 15 Amps socket outlet on independent board using 2.5 Sq mm cable multistranded copper conductor & 2.5 Sq mm cable FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire.
M&L for surface point wiring using PVC casing & caping (ISI marked) (thickness not less than 1.20 mm) complete with PVC insulated unsheathed, 1100 volts grade cable 1.50 Sqmm (nominal area) FRLS type multi stranded copper conductor, single core drawn in and including PVC casing & caping ISI marked including all PVC casing & caping accessories for surface wiring for one light/ fan/ exhaust fan point controlled by one, one way switch on independent board , including concealed pressed steel terminal box of required size (not less than 1.6 mm thick factory made duly painted inside & outside with two coats of black bituminous paint over & including a coat of red oxide primer), with 3 mm thick top cover of plastic laminated sheet of required colour (for mounting switch, sockets, fan regulator etc.) including 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required complete all as specified and directed.
Ditto all as per item No. 9 above but for one, 5amp socket out let on the same board using 2.5 Sq mm cable multistranded copper conductor & 2.5 Sq mm cable FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire.
Ditto- all as item No.9 above for but one, 5amp socket out let on independent board with 2.5 Sq mm cable multistranded copper conductor & 2.5 Sq mm cable FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire.
Ditto all as per item No. 9 above but for one 15 Amp socket outlet on Independent board but with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) multi stranded copper conductor single core including PVC insulated 2.5 sq mm stranded copper conductor green colour as earth wire.
M&L for point wiring in existing conduit with PVC insulated unsheathed, 1100 volts grade cable 1.5Sqmm (nominal area) FRLS type multi stranded copper conductor, single core, drawn in existing conduit for one light/fan/bell/ exhaust fan point controlled by one, one way switch including 3mm thick plastic laminated top cover sheet of required size of white colour, painting of existing pressed steel terminal box with a coat of black bituminous paint and 1.5 Sqmm FRLS type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required complete all as specified and directed.
Ditto all as per item No. 13 above but for one light point controlled by two, two way switches .
Ditto all as per item No. 13 above but for one buzzer or bell point controlled by one, one way switches.
Ditto all as per item No. 13 above but for one, 5amp socket out let on independent board with 2.5 Sq mm cable multistranded copper conductor.
Ditto as per item No. 13 above but for one 15 Amp socket outlet on Independent board with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) multi stranded copper conductor single core.
M&L for concealed submain wiring with two RUNS of single core 4 sqmm stranded copper conductor PVC insulated FRLS type cables for phase and neutral alongwith additional one run of 4 Sq mm stranded copper conductor PVC insulated cable green colour drawn through and including rigid PVC conduit ISI marked not less than 20 mm dia with all accessories, and necessary cutting, chasing & making good distrubed surface to match the existing complete all as specified & directed. Note : (i)Two run of 4 Sq mm single core for Phase /neutral one run of 4 sq mm as earth wire and one run of PVC conduit will be measured as 1 RM unit. (ii) Cost of cutting chasing and it making good distrubed surface to match the existing surface (where ever required) deemed to be included in quoted rates.
M&L for concealed submain wiring with two RUNS of single core 6 sqmm stranded copper conductor PVC insulated FRLS type cables for phase and neutral alongwith additional one run of 6 Sq mm stranded copper conductor PVC insulated cable green colour drawn through and including rigid PVC conduit ISI marked not less than 20 mm dia with all accessories, and necessary cutting, chasing & making good distrubed surface to match the existing complete all as specified & directed. Note : (i)Two run of 6 Sq mm single core for Phase /neutral one run of 6 sq mm as earth wire and one run of PVC conduit will be measured as 1 RM unit. (ii) Cost of cutting chasing and it making good distrubed surface to match the existing surface (where ever required) deemed to be included in quoted rates.
Ditto all as per item No. 19 above but in PVC casing caping.
Ditto all as per item No. 18 above but with 10Sqmm Cable
Ditto all as per item No. 18 above but with 16Sqmm Cable
Ditto all as per item No. 19 above but in existing conduit.
S & F switch piano flush type single pole one way 5 Amp conforming to IS : 3854 complete all as sepcified and directed.
S & F switch piano flush type single pole one way 15 Amp conforming to IS : 3854 complete all as sepcified and directed.
S & F switch piano flush type single pole two way 5 Amp conforming to IS : 3854 complete all as sepcified and directed.
S & F bell push flush type 5 Amp conforming to IS : 3854 complete all as sepcified and directed.
S & F lamp holder PVC carbonate type with back plate complete all as sepcified and directed.
S & F socket outlet 2 in 1 6 Pin 15 Amp flush type conforming to IS : 1293 complete all as specified and directed.
S & F socket outlet 2 in 1 5 Pin 5 Amp flush type conforming to IS : 1293 complete all as specified and directed.
S&F ceiling rose of suitable size of bakelite 240 Volts three terminal as specified and directed.
S&F stepped electronic fan regulator, flush type AC 230 volt 120 W suitable for any type of ceiling fan complete all as specified and directed.
S & F in repair switch piano flush type single pole one way 5 Amp conforming to IS : 3854 complete all as sepcified and directed.
S & F in repair switch piano flush type single pole one way 15 Amp conforming to IS : 3854 complete all as sepcified and directed.
S & F in repair bell push flush type 5 Amp conforming to IS : 3854 complete all as sepcified and directed.
S & F in repair socket outlet 2 in 1 6 Pin 15 Amp flush type conforming to IS : 1293 complete all as specified and directed.
S & F in repair socket outlet 2 in 1 5 Pin 5 Amp flush type conforming to IS : 1293 complete all as specified and directed.
S&F in repair Modular switch, single pole one way 6 Amps 240 Volt capacity flush type all as specified and directed.
S&F in repair Modular Bell push flush type 6 Amps 240 Volt capacity all as specified and directed.
S&F in repair Modular 3 pin 6 Amps socket outlet flush type all as specified and directed.
S&F in repair Modular switch, single pole one way 15 Amps 240 Volt capacity flush type all as specified and directed.
S&F in repair Modular 3 pin 15 Amps socket outlet flush type multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) all as specified.
S&F in repair Modular electronic fan regulator step type AC 230 , 120W - 2 module volt suitable for any type of ceiling fan all as specified and directed.
S&F in repair Modular White cover plate with frame, 2 module all as specified and directed.
S&F in repair Modular White cover plate with frame, 4 module all as specified and directed.
S&F in repair Modular White cover plate with frame, 6 module all as specified and directed.
S&F in repair Modular White cover plate with frame, 8 module all as specified and directed.
S&F in repair Modular metal flush box, 2 module all as specified and directed.
S&F in repair Modular metal flush box, 4 module all as specified and directed.
S&F in repair Modular metal flush box, 6 module all as specified and directed.
S&F in repair bell Ding Dong type single phase 240 Volts complete all as specified and directed.
Taking down existing light fitting any type, keeping in safe custody and again refixing light fitting any type and connection with and including three core flexible copper cable of required length complete all as specified and directed.
S&F in repair 20 Amps single pole and neutral sheet metal enclosure (AC Board) with a two pin and earth plug and socket complete including one SP MCB 20-25 A complete all as specified and directed.
S&F in repair LED luminaire soft light glare free symmetrical illumination surface mounting ceiling light 2x2 panel fitting 36W LED Warm white high lumen efficasy LED lighting fixture, environmental friendly, energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire two core from connector to ceiling rose not more than 1.2mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair LED luminaire soft light glare free symmetrical illumination surface mounting ceiling light 2x2 panel fitting 36W LED high lumen efficasy LED lighting fixture, environmental friendly, energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire two core from connector to ceiling rose not more than 1.2mtr, fixed on wall firmly complete all as specified and directed.
S & F in repair building security light LED 35 Watt pressure die casting aluminium body, heat resistant glass, IP 65 protection, inclusive of electronic driver and all accessories, fixing on wall/pole with GI pipe bracket made of GI pipe 25 to 40 mm light grade 1.2 m long bent to shape and in repairs ,grouting on wall with necessary MS nuts, bolts and washers all as specified and directedMake: Bajaj/Havells/ Philips/ Crompton.
S&F in repair LED tube light fitting 1 x 16 watt, decorative , ultra slim round profile LED lighting fixture with co extruded polycarbonate body , environmental friendly , energy efficient complete with all accessories, prewired and in repairs ,making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair LED tube light fitting 1 x 18 watt, decorative , ultra slim round profile LED lighting fixture with co extruded polycarbonate body , environmental friendly , energy efficient complete with all accessories, prewired and in repairs ,making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair LED tube light fitting 1 x 20 watt, decorative , ultra slim round profile LED lighting fixture with co extruded polycarbonate body , environmental friendly , energy efficient complete with all accessories, prewired and in repairs ,making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair LED tube light fitting 1 x 22 watt, decorative , ultra slim round profile LED lighting fixture with co extruded polycarbonate body , environmental friendly , energy efficient complete with all accessories, prewired and in repairs ,making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair LED mirror light fitting 1 x 9/10 watt, LED 6000 K decorative, indirect up down LED lighting fixture with co extruded polycarbonate body, environmental friendly , energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire two core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair LED bulk head light fitting 10 W LED 600 Lumen enclosed in polycarbonate body, weather proof, LED lighting fixture with co extruded polycarbonate body , environmental friendly , energy efficient complete with all accessories, prewired and making connection and in repairs, including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair wall mounting light fitting 15 watt polycarbonate body, decorative unbreakable complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on wall firmly complete all as specified and directed.
S&F in repair recessed mounting adjustable LED downlights 12W, white powder coated,pressed die cast aluminium housing with high efficiency reflector and spring mounting brackets should be provided for easy installation to the fixture, and in repairs, making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, complete all as specified and directed.
S&F in repair LED spot light fitting 6 W LED 6000 K interior decorative type polycarbonate body, LED lighting fixture , environmental friendly , energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on ceiling complete all as specified and directed.
S&F in repair LED spot light fitting 9 W LED 6000 K interior decorative type polycarbonate body, LED lighting fixture, environmental friendly , energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on ceiling complete all as specified and directed.
S&F in repair LED spot light fitting 12 W LED 6000 K interior decorative type polycarbonate body, LED lighting fixture, environmental friendly, energy efficient complete with all accessories, prewired and making connection with and including 23/0.0076 flexible copper wire three core from connector to ceiling rose not more than 1.2 mtr, fixed on ceiling complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI earth wire 4mm dia by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing wire PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8 mm TMT bars at 80 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and as specified including excavation & earth work & connecting the earthing point/equipment and testing complete all as specified & directed.
S & F Sheet metal enclosure (distribution board), Vertical type, TPN 4 Way 415 V with 200 amps rated bus complete with incoming/outgoing connection through proper size of lugs and cable glands for MCB/MCCB complete all as specified and directed.
S&F MCCB, 4 pole, 415 volts, 100/125 Amps, breaking capacity 25 KA, with thermal magnetic release adjustable type, complete all as specified and directed.
S & F Sheet metal enclosure (distribution board) Double Door for MCBs, 8 Way with 200 amps rated bus bar complete with incoming/outgoing connection through proper size of lugs complete all as specified and directed.
S & F Sheet metal enclosure (distribution board) Double Door for MCBs TPN 4 Way 230V with 200 amps rated bus bar with incoming/outgoing connection through proper size of lugs complete all as specified and directed.
S&F MCB SPN 6-32 Amp, 240 volts 10 KA 'C series' complete all as specified and directed.
S&F MCB SP 6-32 amps 230 Volts, 10 KA 'C series' complete all as specified and directed.
S&F MCB TPN, four pole 63 Amp, 415 volts 10 KA 'C series' complete all as specified and directed.
S&F in repair LED panel driver powered by an independent, SELV output electronic LED driver (SMPS based constant current supply) suitable for 240 volt for 20/22 watt fitting complete all as specified and directed.
S&F in repair LED panel driver powered by an independent, SELV output electronic LED driver (SMPS based constant current supply) suitable for 240 volt for 34/36 watt fitting complete all as specified and directed.
S&F in repair Heating element threaded/ screwed/ triangular or cup style type 2000 Watt ISI marked for Geyser, complete all as specified and directed.
S&F in repair thermostat suitable for 25 or 50 litre capacity of geyser, range 20 to 80 degree ISI marked, for geyser, complete all as specified and directed.
S&F in repair PVC connection cotton braided heavy duty with brass union/ coupling of length 450 mm with rubber washer suitable for 15 mm dia pipe for hot or cold water connection for geyser, complete all as specified and directed.
M S G R ENTERPRISES
SUNSHINE BUILERS
UNIVERSAL ENTERPRISES
ANKIT SHIP REPAIRERS AND SUPPLIERS
Mohit Enterprises
Raj Contruction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .