Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.1 CrAccepted-AOC | ₹6.1 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹6.2 Cr+₹6.6 L (1.07%)Rejected-Finance | ₹6.2 Cr+₹6.6 L (1.07%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹6.2 Cr+₹10.0 L (1.63%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹6.2 Cr+₹10.0 L (1.63%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹6.3 Cr+₹11.3 L (1.83%)Rejected-Finance | ₹6.3 Cr+₹11.3 L (1.83%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹6.9 Cr+₹72.4 L (11.8%)Rejected-Finance | ₹6.9 Cr+₹72.4 L (11.8%) | L5 | Rejected-Finance Not being L1 |
Tender Value
₹5.9 Cr
EMD Value
₹6.2 L
Closing Date
17 Feb 2023, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
ADDN / ALTN AND RENOVATION OF SEKHON BLOCK AT AFA HYDERABAD
2022_MES_566140_1
801535/E8
Open Tender
Civil Works
Item Rate
365 days
GE (AFA) HYDERABAD
A Class Cat a i
8 documents required · 8 mandatory
₹3,000
GE (AFA) Hyderabad
₹6.2 L
Yes
20 Apr 2023
30 Nov 2022
24 Feb 2023
30 Nov 2022
17 Feb 2023
3 Feb 2023
30 Nov 2022 - 15 Dec 2022
Amount
B/R WORKS:- Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, Brushing cement slurry with 3.00 Kg/Sqm on existing concrete surfaces etc complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises to outside MD Land complete all as specified and as directed.
Demolition of reinforced cement concrete of any description in any position complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Taking up or down 15 mm dia steel tubing and connections complete all as specified and as directed.
Taking up or down 20 mm dia steel tubing and connections complete all as specified and as directed.
Taking up or down 25 mm dia steel tubing and connections complete all as specified and as directed.
Dismantling cast iron/ PVC drain or vent pipe of any description in any position including bends branch pieces etc complete all as specified and as directed.
Taking down chowkats or frames with shutters exceeding 1.5 sqm but not exceeding 4 sqm each (without taking off shutters from the frame) including all fittings complete all as specified and as directed.
Taking down Chowkats or frames not exceeding 1.5 sqm but with shutters (without taking off shutters from the frame) complete all as specified and as directed.
Demolition of precast concrete block walling built in cement mortar complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and as directed.
Taking down cement plaster from walls /ceilings built in cement mortar, etc including raking out joints, hacking for key, scrubbing down with water, etc. to receive plaster complete all as specified and as directed.
Taking down cement plaster including existing roof treatment, tar felt including plastering any description and removing the rubbish off the premises, as per the direction by the Engineer-in-Charge, complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
Dismantling timber scantling 40 sq cm and over in section, in any position in unframed work complete all as specified and as directed.
Material and labour for providing mass concrete as in foundation, filling, type D-2, 1:4:8 (40mm graded stone aggregate) complete all as specified and as directed.
Material and labour for providing 75 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base complete all as specified and as directed.
Material and labour for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floors complete all as specified and as directed.
Making good under cills or over arches, lintels and bressummer including all pinning when necessary in CM (1:4) complete all as specified and as directed.
Material and labour for providing Precast PCC type B1 (1:2:4) 20 mm graded stone aggregate in cover slabs, shelves and similar articles with plain faces set in CM (1:4) including necessary formwork complete all as specified and as directed.
Material and labour for taking down of existing sunken slab treatment from the sunken portion and removing of existing filling of sunken, cleaning the surfaces, washing down with water and rubbish off the premises, cleaning and filling cracks with sealing compound, brushing neat cement slurry @ 3.00 kg/Sqm and grouting 25 mm thick cement concrete type B0 1:2:4 (using 12.5 mm graded stone aggregate) on sunken slab portion including filling of PCC Lean concrete 1:5:10 (40 mm graded stone aggregate) and finishing the top surfaces even and smooth without using extra cement including Material and labour for two coat of acrylic cementitious water proofing coating (Dr Fixit Pidifin 2K manufactured by M/S Pidilite Industries Ltd or equivalent) and followed by a overlay protective screed 15 mm thick in CM (1:3) along with liquid water proofing compound approved make on top surfaces of sunken slab after preparation as mentioned above. Method of application for acrylic cementitious water proofing coating is to be followed as per manufacturer's instructions complete all as specified and as directed.
Material and labour for screed bed or bedding layer of mortar 20mm thick for laying floor finishes in CM (1:4) etc complete all as specified and as directed.
Material and labour for screed bed or bedding layer of 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed.
Material and labour for rendering 10 mm thick in cement mortar 1 : 4 as in screed bed complete all as specified and as directed.
Material and labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Material and labour for heavy duty designer tile each having area exceeding 0.06 sqm but not exceeding 0.11 sqm and having thickness 10mm as in floors, parking area, outdoors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid in a Pattern, design and colour as directed by Engineer-in-charge. Make : Durastone of Somany or equivalent approved by GE.
Material and labour for joint free coloured non skid ceramic tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Material and labour for Vitrified Ceramic coloured tiles 10 mm thick Light shade, polished area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors complete all as specified and as directed.
Material and labour for Vitrified Ceramic coloured tiles 10 mm thick dark shade, polished area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match in floors complete all as specified and as directed.
Material and labour for Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Material and labour for coloured glazed ceramic tiles of size 600x300x7 mm thick in skirting & Dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Material and labour for Vitrified Ceramic coloured tiles 10 mm thick Light shade, polished area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match in skirting/ dado complete all as specified and as directed.
Material and labour for Vitrified Ceramic coloured tiles 10 mm thick dark shade, polished area of each tile not exceeding 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match in skirting/dado complete all as specified and as directed.
Material and labour for 20mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window, cills, cooking platforms and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and as directed.
Material and labour for rounding to edges of stone slabs one edge, such as in steps, cooking platforms, and other similar situations complete all as specified and as directed.
Material and labour for pre-cast cement concrete block masonry with solid blocks, PCC 1:3:6, 20 mm graded stone aggregate type C1 exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified and as directed.
Material and labour for providing precast cement concrete solid building blocks or slabs of 10cm thick type C1 (1:3:6) 20mm graded stone aggregate (with plain or interlocking joints as directed) setting in cement mortar (1:4) complete, in walls complete all as specified and as directed.
Material and labour for Reinforced cement concrete type B1 (1:2:4) 20 mm graded stone aggregate, as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, drain cover slabs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
Material and labour for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No. 41 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Supply and fix in true horizontal level false ceiling grid system manufactured by M/S ARMSTRONG WORLD INDUSTRIES US/UK or its equivalent using hot dipped galvanised steel section exposed surface chemically cleaned capping, prefinished in baked polyester paint, main Tee of size 3000x32x15mm at every 1200 c/c, max and 1200mm cross Tee of size 1200x32x15mm at every 600mm c/c, max and 600mm cross Tee of size 600x32x15mm at every 1200mm c/c max and 3000x19x19mm wall angle all around the wall to form grid size of 600x600mm and suspending the grid using 2mm pro-straightened GI wire and 6mm nylon raw plug at every 1299mm intervals at the main tee and supply and fix ARMSTRONG ULTIMA MICRO LOOK manufactured by armstrong world industries or its equivalent approved.
Supply and fix 12mm thick prelaminated particle board exterior grade prelaminated both side with decorative choice lamination as in doors / partitions complete all as specified and as directed.
Supply and fix 5.5mm thick sheet glass ordinary quality and glazing with aluminium beading in square exceeding 0.5 sqm in each pane complete all as specified and as directed.
Supply and fix Solar control film 25 micron reflective type sticked to glass panes as per instruction of manufactures complete all as specified and as directed.
Removing building materials etc to a distance of 10 Km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed.
Supply and fix 1st class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
Material and labour for second class hardwood in scantlings clean sawn timber fixed with nails complete all as specified and as directed.
Material and labour for 2nd class hard wood Plain Fillets, square rectangular or triangular in section, clean sawn, secured with nails or brads area exceeding 13 and not exceeding 25 Sqcm complete all as specified and as directed.
Supply and fix 12 mm thick veneered decorative plywood grade 1 (with BWR resin) with one face decorative veneer fixed with nails to timber frame work complete all as specified and as directed.
Material and labour for 2nd class hard wood plain, solid, straight, chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed.
Supply and fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening complete all as specified and as directed.
Supply and fix 40mm thick flush door shutter, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Supply and fix Factory made solid PVC Moulded door shutter, with particle board core, 28 to 30mm thick (stiles) with 2,4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2 mm plain colour PVC sheet on back face, supplying & fixing in the frame at site complete all as specified and as directed.
Supply and fix Aluminium anodized powder coated (minimum thickness of powder coating 50 micron) frame for door, window and ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and as directed.
Supply and fix Aluminium anodized powder coated door shutter aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips rubber neoprene packing handles 2 nos in each door hinges anodised aluminum snap beading screws etc complete all as specified and as directed.
Supply and fix MS butt hinges medium weight, mild steel hinge pin type B11, 125 mm long complete all as specified and as directed.
Supply and fix extruded aluminium handles cast type polished bright 150 mm long complete all as specified and as directed.
Supply and fix aluminium anodized barrel tower bolts of barrel of extruded section 300 mm long and fixed complete all as specified and as directed.
Supply and fix Aluminium barrel tower bolts of barrel of extruded section 150 mm long and fixed complete all as specified and as directed.
Supply and fix Aluminium, sliding door bolt 300 mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy complete all as specified and as directed.
Supply and fix in repairs Door closer hydraulically regulated, designation No. 3, aluminium die cast body universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Supply and fix in repair floor door stopper of brass body 150 mm long width of cover plate complete all as specified and as directed.
Material and labour for rendering 15mm thick on fair faces of brick work or concrete surfaces 5 mm in CM (1:4) mixed with WPC over 10mm in CM (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for rendering 10mm thick in ceilings in CM (1:3) finished even and smooth without using extra cement complete all as specified and as directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and as directed.
Material and labour for cutting out cracks to V-section upto 5 to 10mm wide in existing roofs or terrace, cleaning out, wetting, grouting with Dr Fixit PU sealant or equivalent approved make complete all as per manufacturers instruction and as directed.
Material and labour for injection grouting for crack filling including identifying the source of leakage, drilling hole in RCC slabs, projections etc of required size and inserting metallic injection packers suitable for high pressure grouting, PU & Epoxy etc. size as per site requirement and manufacturers directions by PU foam (core seal 357A / core seal 357 of Buildcore chemicals or equivalent) as a foam as per manufacturers instructions with recommended pressure and further injecting PU resin (core seal 135A / core seal 135B of Buildcore chemicals or equivalent) as per manufacturers instructions, removal of packers after treatment including making good to surface all as specified and as directed. The number of holes / grouting packers and spacing shall be as per manufacturer instructions and site requirement. The work shall be executed through authorised applicator of manufacturer.
Material and labour providing PCC (1:2:4) type B0 by using 12.5 mm graded stone aggregate as in copings/benching and padding for maintaining slopes where required over slabs/chajjas not exceeding 15 cm thick including necessary form work and finishing the exposed surfaces even without using extra cement complete all as specified and as directed.
Material and labour for rendering 10mm thick in cm (1:3) on concrete surfaces mixed with WPC as per manufacturers instructions finished even and smooth without using extra cement complete all as specified and as directed. Note: WPC shall be measured and paid separately.
Supply only Liquid water proofing compound
Material and labour for Cleaning the roof surface and applying oil bound bitumen primer coat at the rate of 0.20 Kg per Sqm on top of roof. Providing and laying 4 mm thick APP modified water proofing membrane weighing not less than 4 Kg per Sqm and reinforced with polyster non woven polyester mat weighing not less than 160 gms per sqm having softening point not less than 140 degree centigrade, longitudinal tensile strength not less than 800 N per 5 cm, tearing strength of 180 N with minimum of 10 CM side laps and 15 cm end laps by application of torch laid on primed surface as per manufacturers instruction complete. Applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.20 Kg/Sqm. Applying one coat of solar reflective bituminous aluminium paint @ 0.10 Kg per Sqm over bituminous coat complete all as specified and as directed.
Material and labour for mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and as directed.
Supply and fix mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete of Fe 290 Gde E-165 complete all as specified and as directed.
Material and labour for mild steel Rolled back sheet/plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of FE 410 W (Gde E-250) quality A, complete all as specified and as directed.
Material and labour for treating ends of posts, backs of chowkats, etc., area tarred exceeding 0.1 sqm but not exceeding 0.5 sqm each ditto with tar or coal tar black paint complete all as specified and as directed.
Material and labour for Sanding newly tarred or painted surfaces with clean sharp sand complete all as specified and as directed.
Material and labour for preparation of new plastered external wall surfaces and applying two coats of cement based paint over a alkali resistant primer coat etc complete all as specified and as directed.
Material and labour for preparation for new surface on walls and applying two coats of oil bound distemper over a primer over 3mm thick wall care putty on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation for new surface on ceilings and applying two coats of oil bound distemper over a primer over 3mm thick wall care putty on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old plastered external wall surfaces by complete removal of existing treatment and applying two coats of cement based paint etc complete all as specified and as directed.
Material and labour for complete removal of the existing treatment on walls and applying two coats of oil bound distemper over a primer over 3mm thick wall care putty on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for complete removal of the existing treatment on walls and applying two coats of Plastic emulsion over a primer over 3mm thick wall care putty on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for complete removal of the existing treatment on ceilings and applying two coats of oil bound distemper over a primer over 3mm thick wall care putty on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
Material and labour for applying acrylic smooth exterior weather proof paint of required shades in two or more coats @ 1.67 lit / 10 Sqm over a coat of exterior primer applied @ 2.20 Kg / 10 Sqm including removal of existing treatment and preparation of surface complete all as specified and as directed.
Material and labour for preparing of new surfaces of wood exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink wood primer complete all as specified and as directed.
Material and labour for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all as specified and as directed.
Material and labour for preparation of old painted wooden surfaces of any description, not otherwise described over 10cm width or girth, applying two coats of synthetic enamel paint over a coat of pink primer etc complete all as specified and as directed.
Material and labour for preparing new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described over 10cm width or girth and applying a coat of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described not exceeding 10 cm width or girth and applying a coat of synthetic enamel paint complete all as specified and as directed.
Supplying and Laying of 20 mm outer dia CPVC pipes SDR 11 ISI marked and Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and Laying of 25 mm outer dia CPVC pipes SDR 11 ISI marked and Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and Laying of 32 mm outer dia CPVC pipes SDR 11 ISI marked and Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supply and fix in repairs Vitreous china wash down water closet pan (Pedestal pattern) white including all fittings (excluding flush tank) complete all as specified and as directed.
Supply and fix in repairs counter type vitreous China wash basin white flat back, size 630x450mm including brackets etc complete with granite top all as specified and as directed. (Note : Granite slab shall be measured and paid separately)
Supply and fix in repairs Vitreous China half stall urinal, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement etc complete all as specified and directed.
Supply and fix in repairs fancy type chromium plated bib taps cast copper alloy fixed to iron pipe or for brass ferrule for 15mm bore pipes complete all as specified.
Supply and fix in repairs fancy type chromium plated pillar taps cast copper alloy fixed to iron pipe or for brass ferrule for 15mm bore pipes complete all as specified.
Supply and fix in repairs Angle valve cast copper alloy fancy type chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for Iron pipe or for unions and fixed for 15mm dia GI pipe etc complete all as specified.
Supply and fix in repairs Stop valves 20mm dia, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed/Angular type) screwed down, high pressure with crutch or butterfly handle, screwed both ends or unions and fixed for 15mm dia GI pipe and fixed complete all as specified and as directed.
Supply and fix in repairs 125mm size brass chromium plated shower rose with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed.
Supply and fix in repairs Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (Min weight 60 gms) complete all as specified and as directed.
Supply and fix in repairs urinal partitions slabs vitreous china white 310x700 mm terminating about 40 cm above floor line complete all as specified and as directed.
Supply and fix in repairs Tubular towel rail brass chromium plated 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
Supply and fix in repairs Toilet paper holder, vitreous china (white, box type fixed to walls with chromium plated brass screws complete all as specified and as directed.
Supply and fix in repairs soap dish vitreous china white 160x160x90 mm approx fixed to plugs with chromium plated brass screws complete all as specified and as directed.
Supply and fix in repairs PVC valve less, symphonic action type, flushing cistern, 10 litres, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
Supply and fix in repairs 40 mm PTMT bottle traps for wash basins/urinals with inlet and out screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed.
Supply and fix 40mm Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sqcm complete all as specified and as directed.
Supply and fix in repairs PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and as directed.
Supply and fix in repairs 1000 litre capacity Rotational moulded polyethylene triple layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed.
Supply and fix in repairs ball brass valves high pressure, with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed for 25 mm dia complete all as specified and as directed.
Supply and fix in repairs CPVC SDR 11 ball valve ISI marked all as specified and directed of following outer dia
(a) 32 mm dia
(b) 25 mm dia
(c) 20 mm dia
Supply and fix 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed.
Supply and fix 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed.
Supply and fix PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall 110mm bore including fittings complete all as specified and as directed.
Supply and fix PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall 75mm bore including fittings complete all as specified and as directed.
Supply and fix in repairs 110 mm bore PVC (SWR) vent cowl complete all as specified and as directed.
Supply and fix in repairs 75 mm bore PVC (SWR) vent cowl complete all as specified and as directed.
Supply and fix 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
Supply and fix in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including taking down existing sinks complete all as specified and as directed.
Supply and fix in repairs Curved shaped urinal partition with frosted glass 8mm Finish: Chrome Size H: 900 mm W: 450 mm. PRODUCT CODE: JSE-CHR-110UC450X Make : Jaguar / equivalent approved.
Supply and fix in repairs white coloured vitreous china cascade type EWC (Size 510 x 295 x 520 mm) including making good to floor complete all as specified and as directed. (Model : S1013130 Cindrella Junior of Make : Cera or Equivalent approved)
Supply and fix in repairs fancy type chromium plated pillar taps cast copper alloy fixed to iron pipe or for brass ferrule for 15mm bore pipes complete all as specified. (Make : Jaguar or Equivalent approved)
Supply and fix in repairs Angular Stop Cock with Wall Flange PRODUCT CODE: OPP-BCH-15053PM PRODUCT RANGE: OPAL PRIME (Make : Jaguar or Equivalent approved)
Supply and fix in repairs single lever wall mixer with provision for overhead shower with 115 mm long bend pipe on upper side, connecting legs and wall flanges complete all as specified. (Make : Jaguar-opal prime or Equivalent approved)
Supply and fix in repairs Overhead Shower 100mm dia Round Shape Single Flow (ABS Body Chrome Plated with Gray Face Plate) with Rubit Cleaning System PRODUCT CODE: OHS-CHR-1989 of Make : Jaguar or Equivalent approved)
Supply and fix in repairs stainless steel Toilet Roll holder with flap. (Model : CAN-CHR-1153S) Make : Jaguar Continental / equivalent approved
Supply and fix in repairs two-in-one bib cock with wall flange 15 mm bore (Model :FON-CHR-40041) (Make : Jaguar / Equivalent approved)
Supply and fix in repairs Health Faucet 1.2 m long easy flex tube in chrome finish and wall hook with NRV (Model :ALD-CHR-573) (Make Jaguar / Equivalent approved)
Supply and fix in repairs stainless steel Single towel rail 600 mm long including all fitments (Model:ACN-CHR-1111SM) (Make : Jaguar/ Equivalent approved)
Dismantling boarding, any description, fixed in any position with screws in framed work complete all as specified and as directed.
Material and labour for 2nd class hardwood boarding 20 mm thick in floors and skirting planed on one side with butt joints and fixed with screws complete all as specified and as directed.
Material and labour for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil complete all as specified and as directed.
Supply and fix half stall urinal (Model : URS-WHT-132530) along with Sensor mini concealed type flushing valve (Make:SNR-STL-51083) complete with all fittings all as specified and directed at site by Engineer-in-Charge. Make: Jaguar or equivalent approved
Supply and fix Automatic Soap Dispensers, Capacity : 0.8L, Material: Aluminium/ABS, Finish : Chrome/Black PRODUCT CODE: SDR-BLC-DJ0160AS of make Jaquar or equivalent approved all as specified and as directed.
Cutting openings through walls for door, window and other openings or enlarging existing openings, etc., including providing, fixing and removing, shoring, cleaning and stacking stone and removing surplus to stone and rubbish off the premises etc complete all as specified and as directed.
Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and as directed.
Making good under cills or over arches, lintels and bressummer including all pinning when necessary in CM (1:4) applying two coats of oil bound emulsion over a primer over 3mm thick wall care putty on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fix Anodised aluminium powder coated window shutter (glazed / gauzed for fly proofing), sliding type without sash bars, aluminium section weighing not less than 0.55Kg/m including necessary joining cleats, glazing clips or mesh channel, rubber packing, neoprene gasket anodized aluminium snap beading, screws and all necessary fittings, rollers locking plates etc as required complete all as directed. Note: Frame / track, glass and wire cloth shall be measured and paid separately.
Supply and fix 4mm thick sheet glass ordinary quality plain / tinted and glazing with aluminium beading in aluminium windows complete all as specified and as directed.
Supply and fix galvanised steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.4mm fixed to aluminium windows complete all as specified and as directed.
Supply and fix in repairs 18/20mm thick preformed filler for expansion / crumple joints complete all as specified and as directed.
Material and labour for 0.56mm thick plain aluminium sheeting, alloy 31000H4 fixed to crumple joints with necessary rawl plugs complete all as specified and as directed.
Material and Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed.
Supply and fix 6mm thick toughened glass as inserts in SS railing, in hinged doors, partitions and similar works including cutting to shape, drilling holes complete all as specified and as directed.
E/M WORKS:- Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Taking down unserviceable MCBs, DBs, Main switches complete all as specified and as directed.
Taking down unserviceable MCBs, from DBs complete all as specified and as directed.
Taking down unserviceable MCCBs, from DBs complete all as specified and as directed.
Taking down ceiling fan, wall mounted fan dismantling blades and removing fan will be keep in safe custody by the contractor with proper inventory and refixing ceiling fan, wall mounted fan after completion of re-wiring and connecting up by cleaning/oiling etc including provision of 3 core flexible round cable from ceiling rose or connector to fan all as directed.
Material and labour for Point wiring with 1.5 Sqmm copper conductor unsheathed, multistranded, PVC insulated, single core cable FRLS with earth continuity conductor of 1.5 sqmm PVC insulated copper conductor and including rigid PVC concealed conduit of suitable size but not less than 20mm dia and all accessories fixed to be concealed in wall & surface of the roof etc., including modular type terminal boxes made out of Galvanised sheet of thickness should be not less than 0.9mm thick for fixing of modular switches, modular fan regulators, modular socket outlet etc along-with suitable modular plate for housing switches, etc complete all as specified and as directed.
(a) One light point controlled by one switch
(b) One light point controlled by two, two way switches
(c) One ceiling/Exhaust fan/Wall Fan point controlled by one switch
(d) One three pin socket 5 Amps plug point independent
(e) One three pin socket 5 Amps plug point on same board
All as per Ser item No 158 above but with 2.5 sqmm copper cable in and including PVC conduit complete all as specified and as directed for 15A socket.
Supply and fix ceiling rose, three terminal, PVC/polycarbonate, insulated body, ISI marked complete all as specified and as directed.
Supply and fix Modular Switch type polycarbonate white 1 way, 6A, 240Volts complete all as specified.
Supply and fix Modular Switch type polycarbonate white 1 way, 16A, 240Volts complete all as specified.
Supply and fix Modular Switch type polycarbonate white 2 way, 10A, 240Volts complete all as specified.
Supply and fix Modular socket outlet 3 pin 6 amp flush type, 240Volts complete all as specified.
Supply and fix Modular Socket outlet polycarbonate white 10A - 2/3 pin complete all as specified.
Supply and fix Modular Socket outlet polycarbonate white 20A - 2/3 pin complete all as specified.
Supply and fix step type polycarbonate white electronic fan regulator flush type 2 module all as specified and as directed.
Supply and fix surface mounting/wall mounted LED tube light fitting 1x8 to 10watts high efficiency, anti glare, maintenance free operation including LED driver and mounting arrangements, all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size including taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and fix surface mounting/wall mounted LED tube light fitting 1x20/18watts high efficiency, anti glare, maintenance free operation including LED driver and mounting arrangements, all accessories internally pre-wired, connecting up with twin core twisted flexible copper conductor cable white colour with suitable size including taking out old unserviceable one complete all as specified and directed by Engineer-in-Charge.
Supply and Fix 1X36 to 40W high efficiency 2X2 recess mounting LED light fitting with glare free homogeneous illumination including LED driver with all accessories internally pre-wired, connecting up with three core twisted flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge.
Supply and fix surface mounting LED light fitting of 15 W LED round complete with inbuilt driver, 230 V with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge. Note : For Corridor
Supply and fix surface/wall mounted LED track Light 18 Watt with inbuilt driver 230 V with all accessories for fixing in ceiling or on wall internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-charge. Note : For Corridor/central foyer
Material and labour for Sub Main wiring with 4x16 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 2x16 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete including taking down old sub main wiring all as specified and directed by Engineer-in-Charge.
Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iii) Six runs of cable and one run of PVC conduit will be measured as one unit.
Material and labour for Sub Main wiring with 4 x10 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 2x10 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dully complete including taking down old sub main wiring all as specified and directed by Engineer-in-Charge.
Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) Six runs of cable and one run of PVC conduit will be measured as one unit.
Material and labour for Sub Main wiring with 2x6 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X6 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dolly complete including taking down old sub main wiring all as specified and directed by Engineer-in-Charge.
Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) Three runs of cable and one run of PVC conduit will be measured as one unit.
Material and labour for Sub Main wiring with 2x4 Sqmm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit of size 25mm or higher suitable size with all necessary fittings, concealed in walls/roof/floor duly earthed with 1X4 Sqmm of single core cable but green in colour as continuous earthing wire and connecting to common earth dolly complete including taking down old sub main wiring all as specified and directed by Engineer-in-Charge.
Note :- (i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate. (ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. (iv) Three runs of cable and one run of PVC conduit will be measured as one unit.
Supply and fix MCCB DB 4 way triple pole vertical type, double door metallic, powder coated, 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed.
Supply and fix MCCB DB 6 way triple pole vertical type, double door metallic, powder coated, 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed.
Supply and fix MCCB DB 8 way triple pole vertical type, double door metallic, powder coated, 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed.
Supply and fix MCB DB 8 way SPN DB, double door metallic, powder coated, 230volts 50 Hz AC supply including fixing to the existing wall (concealed/surface) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed.
Supply and fix MCB DB 12 way SPN DB, double door metallic, powder coated, 230volts 50 Hz AC supply including fixing to the existing wall (concealed/surface) and making good the disturbed surface of wall with the existing wall complete all as specified and as directed.
Supply and fix MCCB 4 pole 63Amps, 16KA breaking capacity, 415 Volts 3-phase supply complete all as specified and as directed.
Supply and fix MCCB 4 pole 100Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and as directed.
Supply and fix MCB SPN 32 AMP rating 240V, 10KA 'C' curve in the MCB DB with connection testing and commissioning complete all as specified and as directed.
Supply and fix MCB SP 240V, 10 KA 'C' curve and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed.
Supply and fix dummy PVC cover (blanking plates) for existing MCB DBs complete all as specified and as directed.
Taking down of old unserviceable LT Panel board of any capacity and type including disconnecting all electrical connection and making good to the disturbed surface as per existing complete all as specified and directed by Engr-in-Charge.
Supplying, installing, testing and commissioning Indoor LT electrical panel/feeder pillar box suitable for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating provided with suitable gasket dust & vermin proof and general construction confirming to IS : 375 degree of protection shall not be less than 1P-51 as per IS : 2147 and it shall be suitable to withstand a Fault level of 50 KA (rms) for one second made of 2 mm thick CRCA sheet for outer panel and 1.6 mm thick for internal compartments totally enclosed weather, dust and vermin proof, suitable size but not less than 2000mm (height) x900mm (width) x 300mm (depth), suitable for fitting inside wall having proper locking arrangement in both front two door with 4 side slanting, all as specified in SSR Part-I and as directed comprising of following :-
Supply and fix perforated cable tray, made of 2.0mm Galvanized iron sheet, duly bended to required shape by sheet bending machine, including cover, made of 1.2mm thick Plain Galvanized iron sheet duly screwed with the cable tray and duly fixed on the wall/ceilings including suitable Galvanized iron brackets or hanging from the ceiling with suitable suspender as required at site all as specified and as directed by the Engineer -in Charge for the following sizes :-
a) Tray size 75x100x2mm with cover of size 15x105x1.2mm
b) Tray size 100x150x2mm with cover of size 15x155x1.2mm
c) Tray size 100x200x2mm with cover of size 15x205x1.2mm
d) Tray size 100x250x2mm with cover of size 15x255x1.2mm
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1440, Copper winding of sweep 250 mm including louvers and making good with matching colour with the surroundings provision of cable 3 core of size 0.5 Sqmm (16/0.2 mm) from ceiling rose to fan, including making necessary opening on stone/brick masonry wall and all as specified and as directed.
Supply, laying and testing of cable XLPE insulated LT 1100 volts of grade armoured heavy duty electric cable with aluminium conductor of cross sectional area 300 sqmm 3.5core including connecting to panel boards with the suitable size of aluminium lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing of cable XLPE insulated LT 1100 volts of grade armoured heavy duty electric cable with aluminium conductor of cross sectional area 150 sqmm 3.5core including connecting to panel boards with the suitable size of aluminium lugs complete all as specified and directed by Engr-in-Charge.
Supply, laying and testing of cable XLPE insulated LT 1100 volts of grade armoured heavy duty electric cable with aluminium conductor of cross sectional area 120 sqmm 3.5core including connecting to panel boards with the suitable size of aluminium lugs complete all as specified and directed by Engr-in-Charge.
Supplying, installing, testing and commissioning Indoor LT electrical panel/feeder pillar box suitable for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating provided with suitable gasket dust & vermin proof and general construction confirming to IS : 375 degree of protection shall not be less than 1P-51 as per IS : 2147 and it shall be suitable to withstand a Fault level of 50 KA (rms) for one second made of 2 mm thick CRCA sheet for outer panel and 1.6 mm thick for internal compartments totally enclosed weather, dust and vermin proof, suitable size but not less than 2000mm (height) x1500mm (width) x 1000mm (depth), having proper locking arrangement in both front & rear door with 4 side slanting, on angle iron platform frame of 50x50x6mm of height 18cm above ground level and 12cm in floor and with one coat of red oxide primer and two coats of black paint all as specified in SSR Part-I and as directed comprising of following :-
Supply and fix refrigerant pipes for suction and discharge lines for connection of indoor to outdoor units of 1.5/2 ton split AC of standard size as per OEM recommendation with proper insulation including fixing arrangement with powder coated MS clamps and jointing of pipe etc including all necessary items required all as specified and directed by Engr-in-Charge. Note:- Two runs of insulated copper tubing (for in and out flow) and one run of 3 core copper wire will be measured as one unit.
Supply and fix PVC pipe 25mm dia high grade for ACs drain water, including tees bends reducers for leakage free jointing etc, including clamps and other material for fixing on wall/cemented surface at a height of 30 to 50 feet all as specified and directed by Engineer-in-Charge
Supply and fix PVC pipe 40mm dia high grade for ACs drain water, including tees bends reducers for leakage free jointing etc, including clamps and other material for fixing on wall/cemented surface at a height of 30 to 50 feet all as specified and directed by Engr-in-Charge
Material and labour for shifting of existing hi wall split units indoor with stabilizer of any capacity and outdoors complete with cordless remote control unit for operation on 230 volt 50 Hz single phase AC supply and outdoor (condensing) unit to be and copper refrigerant pipes for suction & discharge lines of standard size as required duly insulated including jointing pipes 3 core copper cable of suitable size from stabilizer to indoor units all as specified and as directed. Note:- Additional copper pipe will be measured and paid separately
Supply and fix mild steel angle iron frame of size 50 mm x 50 mm x 6 mm suitable for fixing of split AC's 1.5/2 ton out door unit including fixing on wall with all fixing arrangement require for fixing inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint all as specified and directed by Engr-in-charge
Supply and toping up/charging of refrigerant gas (R-22/R-410/R-32) for ACs as per standard practice as per existing gas all as specified and directed by Engr-in-Charge.
Supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB 20 Amps capacity including taking down old sheet Metal enclosures of any capacity complete all as specified and as directed.
Supply and fix single phase modular type motor starter 32 A, 240 Volts, 50 Hz for split AC including cover plate and PVC surface box of suitable size complete all as specified and as directed.
Material and labour for taking down old unserviceable GI lead / aluminium strip removed from wall on batten or recess or buried in ground or conduit/ pipe etc of any type and size all as specified and directed by Engr- in- Charge.
Material and labour for insulating only to copper tubing of split type AC of cap 1.5/2 TR with heavy duty rubber foam insulation as per existing density and thermal conductivity including packing material, reflector tape and PVC tie complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable Air Termination, single pointed Aluminium / copper rod of any type and size all as specified and directed by Engr- in- Charge.
Supply and fix Air Termination, Single pointed, Aluminium rod 12 mm dia and 300 mm long complete all as directed.
Supply and fix Aluminium strip 25 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground and the other end connected to test point complete all as directed.
Supply and fix copper strip 32x6mm with saddles and fixing screws etc for roof conductors and down conductors above ground and the other end connected to test point complete all as directed.
Supply and fix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex. head screw complete including taking down old test point all as specified and as directed.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth strip 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I and as directed.
Note: (i) Cost of aluminium strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling, removing, PCC chamber pit, RCC cover, test point etc.
Material and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine and inserting GI pipe of 100mm all as specified and as directed. Note:- Pipe shall be measured and paid separately under relevant item.
Supply and fix 100 mm bore light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc complete all as specified and as directed.
Material and labour for earth continuity conductor Galvanised iron strip 32 x 6mm buried in ground or on wall with saddles and fixing screws etc for roof conductors and down conductors above ground all as specified and as directed by the Engr- in -Charge.
Supply and fix DMC/FRP insulators, of suitable size to separate the earth strips from the walls, duly screwed on the walls and making holes in the earth strips by drilling and fixing the earth strip rigidly with the insulators with GI bolts, nuts, washers etc complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard/dense soil all as specified and directed.
Material and labour for Sub Class 'B' brick covering protection to the electric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and as directed.
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30cm (8cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note :- (i) Excavated soil shall be riddled by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches as in cable cushioning.
Returning, filling in with excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in hard/dense soil all as specified and as directed.
Removing excavated material/surplus soil not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Supply, installation and testing of cooker hood electric chimney, having exhaust suction 1100 cubic meter per hrs, baffle filter, 2x halogen lighting of size 60 cms, body finishing stainless steel & glass, 240 Volt AC control with push button switch, and exhaust duct complete, suitable for mounting on roof/wall angle iron and accessories, and fixing attachment all as specified and as directed.
Material and labour for cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 for concealed conduit wiring etc and making good, cutting not exceeding 10 cm in brick walls complete all as specified and as directed.
Material and labour for rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of the following dia including GI wire for pulling common cable subsequently complete all as specified and as directed.
Supply and fix junction boxes (1 to 4 way)
M/s Amit Associates
Phoenix Infra
Dwarka Pershad Radhey Ramanlal
TRIVENI CONSTRUCTIONS
AP BUILDERS
TARUN CONSTRUCTION COMPANY
B.N.S Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .