| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.2 L+₹1.6 L (5.26%)Rejected-Finance SIDDHARTH ENCLAVE NEAR JINDAL FACTORY RAMNAGAR ROORKEE 247667 | HARIDWAR | UTTARAKHAND | 247667 | L2 | Rejected-Finance Quoted other than lowest rates. | |
| 3 | L3₹37.0 L+₹7.3 L (24.6%)Rejected-Finance KOHLI NO 17509 GALI KHADDAR BHANDAR WALI BHI WALA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Quoted other than lowest rates. | |
| 4 | L4₹40.1 L+₹10.4 L (35.0%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L4 | Rejected-Finance Quoted other than lowest rates. | |
| 5 | L5₹40.1 L+₹10.4 L (35.2%)Rejected-Finance | L5 | Rejected-Finance Quoted other than lowest rates. |
Tender Value
₹46.3 L
EMD Value
₹92,600
Closing Date
25 Feb 2025, 6:00 pmClosed
Shri Jitender Singh, IDSE, EE
GE (N) Bathinda
ADDN/ALTN OF EXHAUST FAN, PROVN OF EXHAUST FAN AND ADDN/ALTN OF OLD OUTDATED SODIUM VAPOUR FLOOD LIGHTS TO LED FLOOD LIGHTS UNDER AGE E/M -V OF GE (N) BATHINDA AT BATHINDA MIL STN
2025_MES_691946_1
8939/NIT-57/24-25/E8
Open Tender
Civil Works
Item Rate
150 days
Bathinda
Class D Category b (i)
8 documents required · 8 mandatory
₹500
Yes
GE (N) Bathinda
₹92,600
Yes
13 Mar 2025
6 Jan 2025
27 Feb 2025
6 Jan 2025
25 Feb 2025
18 Feb 2025
6 Jan 2025 - 13 Jan 2025
Amount
Supply and fixing of exhaust fan steel body 300 mm sweep with and including blades, frame and louvers, 230V, single phase AC supply, including making exhaust hole outlet way on walls as per site requirement, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing extra shall be paid on this account, Srl number will be issued by Engineer-in-Charge. (ii) PVC cable for making electric connections shall be measured and paid separately under respective item of BOQ.
Supply and fixing of exhaust fan PVC body 250 mm sweep with and including blades, frame and louvers, 230V, single phase AC supply, including making exhaust hole outlet way on walls as per site requirement, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing extra shall be paid on this account, Srl number will be issued by Engineer-in-Charge. (ii) PVC cable for making electric connections shall be measured and paid separately under respective item of BOQ.
Supply and fixing of PVC insulated, unseathed multistranded, three core twisted copper flexible cable of size 1.5 sqmm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for concealed point wiring complete with 1.5 sqmm (nominal cross section area ) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt drawn through and including PVC rigid conduit 20mm dia( heavy duty ) with all fittings and all accessories i.e pipe bend, pipe hook, elbow,junction box, pressed steel powder coated sunken box of suitable size (min 60mm deep, suitable length and 1.2mm thick ), 3mm thick bakelite plastic laminated sheet for mounting switches and socket ,fan regulator, for light/fan point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 1.5 sqmm FRLSH PVC insulated multi stranded copper conductor wire as continuous earth wire connected to earth dolly etc including cutting chases in wall and making good distrubed surface of wall/ceiling/floors etc by using cement mortar (1:3 ) to matching with existing surface, complete all as specified and directed by Engineer-in-charge. Note :- (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clips all as directed by Engr-in-Charge.
Supply and fixing switch piano flush type, single pole,one way, 5/6 Amps, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing ceiling rose surface type poly carbonate 6 Amp 250V AC 20 X 50 mm, two to three terminal, complete all as specified and directed by Engineer-in-charge.
Supply and fixing of exhaust fan steel body 450 mm sweep with and including blades, frame and louvers, 230V, single phase AC supply, including making exhaust hole outlet way on walls as per site requirement, hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface as per existing surfaces, and connection to fan with suitable flexible twin core round copper wire complete all as specified and directed by Engineer-in-Charge. Note :- (i) Srl Number of exhaust fan and 'GE North BTD' shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate, nothing extra shall be paid on this account, Srl number will be issued by Engineer-in-Charge. (ii) PVC cable for making electric connections shall be measured and paid separately under respective item of BOQ.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant including driver and lamp complete all as specified and directed by Engineer-in-Charge.
All as per item No 4 here in before but for one socket outlet 6 pin, 6/16 Amp multipurpose 2 in 1 on independent board with cable of 2.5 sqmm, multi stranded copper conductor FRLSH cable including provision of 2.5 sqmm PVC insulated solid copper conductor FRLSH cable as continuous earth wire connected to earth dolly, conductor etc., complete all as specified and directed by Engineer-in-charge.
Supply and fixing switch piano flush type, single pole, one way, 15/16 Amps, complete all as specified and directed by Engineer-in-charge.
Supply and fixing (concealed in wall or as directed) factory made DB (made out of CRCA sheet not less than 1.2 mm thick) SPN, 8 Way, 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-54 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484, dust and vermin proof, including making good disturbed surfaces of walls as necessaty, complete all as specified and directed by Engineer-in-charge.
Supply and fixing MCB SPN 32 Amps, 10 KA 'C' curve 230 V AC, 50 Hz including necessary attachment complete all as specified and directed by Engineer-in-charge.
Supply and fixed MCB SP suitable for 230 volts AC supply 5/6 to 32 Amps, SP rupturing capacity not less than 10KA, 'C' curve, complete all as specified and directed by Engineer-in-charge.
ANANT ENTERPRISES (BID ID -3248573)
M/s BHUPINDRA ENGINEERING WORKS (BID ID -3249367)
Mohinder Pal and Sons (BID ID -3247312)
B D BATRA AND SONS (BID ID -3249286)
AJ. Owners (BID ID -3249534)
rkkataria and sons (BID ID -3248109)
M/S Gagan Khosla (BID ID -3246932)
m/s s.n. builders (BID ID -3245117)
SIGMA ENGINEERS AND CONTRACTORS (BID ID -3248878)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .