| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹36.3 L+₹2.2 L (6.34%)Rejected-Finance 131 SHINGANAPUR ROAD KOLKI KOLKI SATARA MAHARASHTRA 415523 | SATARA | MAHARASHTRA | 415523 | L2 | Rejected-Finance Being other than lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical MoU not submitted | |
| 4 | Rejected-Technical 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | - | Rejected-Technical MoU not submitted | |
| 5 | Rejected-Technical 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | - | Rejected-Technical MoU not submitted |
Tender Value
₹49.5 L
EMD Value
₹99,060
Closing Date
6 Oct 2023, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
REPAIR/ REPLACEMENT OF UNSV ITEMS FOR VOLTAGE STABILIZER, LT CABLE, CHEMICAL EARTHLING AND REROUTING OF LT/ HT CABLE, EARTHLING CHECKING, UPS BATTERY AND OTHER E/M MISC WORKS AT BHDC UNDER GE (EAST) DELHI CANTT-10
2023_MES_610338_2
GE/DE-50/2023-24
Open Tender
Civil Works
Item Rate
365 days
GE (EAST) DELHI CANTT-10
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹99,060
Yes
19 Feb 2024
15 Sept 2023
9 Oct 2023
15 Sept 2023
6 Oct 2023
22 Sept 2023
Amount
M&L for comprehensive maintenance of 50 KVA -02, Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 02 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stablizer from 50 KVA size and capacity ,removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's,Regulators,Condensors,Triac,Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. : The job also incl. shifting through crane with necessory accessories & to and fro transportation from site to work shop and vise- versa. Spares Parts if required shall be measured and paid separately.
Repair and rewinding of 28 amp dimmer
Repair and rewinding buck/boost loading transformer cap. 100 KVA.(each phase)
Supply only cut off circuit with contractor cap 70 Amp TP
Supply only control wiring.
Power wiring and copper thimble
Input/output connection cap 100 Amp
M&L for comprehensive maintenance of 75 KVA -03 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 03 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stablizer from 75 KVA any size and capacity ,removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's,Regulators,Condensors,Triac,Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. The job also incl. shifting through crane with necessory accessories & to and fro transportation from site to work shop and vise- versa.
Repair and rewinding of 40 amp dimmer
Repair and rewinding buck/boost loading transformer cap. 150 KVA.(each phase)
Supply only cut off circuit with contractor cap 110 Amp TP
Supply only control wiring.
Power wiring and copper thimble
Input/output connection cap 200 Amp
M&L for comprehensive maintenance of 100 KVA -03, Nos Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 02 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stablizer from 200 KVA any size and capacity ,removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's,Regulators,Condensors,Triac,Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. The job also incl. shifting through crane with necessory accessories & to and fro transportation from site to work shop and vise- versa.
Repair and rewinding of 75 amp dimmer
Repair and rewinding buck/boost loading transformer cap. 100 KVA.(each phase)
Supply only cut off circuit with contractor cap 200 Amp TP.
Supply only control wiring.
Power wiring and copper thimble
Input/output connection cap 200 Amp
M&L for comprehensive maintenance of 150 KVA -04 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 04 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stablizer from 500 KVA to 500 KVA any size and capacity ,removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's,Regulators,Condensors,Triac,Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. : The job also incl. shifting through crane with necessory accessories & to and fro transportation from site to work shop and vise- versa.
Repair and rewinding of 100 amp dimmer
Repair and rewinding buck/boost loading transformer cap. 150 KVA.(each phase)
Supply only cut off circuit with contractor cap 200 Amp TP.
Supply only control wiring.
Supply Power wiring and copper thimble
Input/output connection cap 200 Amp
M&L for comprehensive maintenance of 200 KVA -01, Nos Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 01 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stablizer from 200 KVA any size and capacity ,removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's,Regulators,Condensors,Triac,Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. : The job also incl. shifting through crane with necessory accessories & to and fro transportation from site to work shop and vise- versa.
Repair and rewinding of 120 amp dimmer
Repair and rewinding buck/boost loading transformer cap. 200 KVA.(each phase)
Supply only cut off circuit with contractor cap 300 Amp TP.
Supply only control wiring.
Supply Power wiring and copper thimble
Input/output connection cap 300 Amp
M&L for comprehensive maintenance of 250 KVA -04, Nos Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 04 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stablizer from 250 KVA size and capacity ,removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's,Regulators,Condensors,Triac,Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. : The job also incl. shifting through crane with necessory accessories & to and fro transportation from site to work shop and vise- versa.
Repair and rewinding of 150 amp dimmer
Repair and rewinding buck/boost loading transformer cap. 50 KVA.(each phase)
Supply only cut off circuit with contractor cap 300 Amp TP.
Supply only control wiring
Power wiring and copper thimble
Input/output connection cap 100 Amp
M&L for comprehensive maintenance of 400 KVA -01, Nos Servo Voltage Stabilizer/ Servo Voltage Regulator complete all as specified and directed. Contract Details:- (i) Free maintenance and repair of Normal accessories (Spare Parts) .- 03 Nos Servo Voltage Stabilizer/ Servo Voltage Regulator. (ii) Preventive maintenance of all systems on quarterly basis and upkeep of Report. (iii) Attending all complaints within 24 working hours. Note:- (a) The rates quoted by the contractor shall deemed to be inclusive of T&P etc (b) Major Spares Part shall be measured and paid for separately under respective item of this Schedule as supply only. (c) Dismantling and removing of defective voltage stablizer from 400 KVA any size and capacity ,removing to workshop for repair, opening up and taking out coil, core and core assembly for estimation of repair and damaged parts cleaning/washing of tanks and removing the dust from all parts including cores, tanks, cooling tubes, removal of damaged parts making connection and assembling complete in all respects after repair of coils IC's,Regulators,Condensors,Triac,Transistors etc. respective cards nuts and bolts, refilling of transformer oil, installation and testing on full load for testing completely all as specified and directed by the Engr-in-Charge. Note: 1. Spare parts and winding coils as mentioned under respective items of schedule shall be measured and paid for separately as supply only. These shall be identical to those specified by original manufacturer. Note 2. : The job also incl. shifting through crane with necessory accessories & to and fro transportation from site to work shop and vise- versa.
Repair and rewinding of 300 amp (150x2) dimmer
Repair and rewinding buck/boost loading transformer cap. 400 KVA.(each phase)
Supply only cut off circuit with contractor cap 630 Amp TP.
Supply only control wiring
Power wiring and copper thimble
Input/output connection cap 400 Amp
Supply electronic control card. 50 KVA to 500 KVA
Supply Amp meter (Digital) 50 KVA to 500 KVA
Supply Volt meter (Digital) 50 KVA to 500 KVA
Supply Synchronus motor 10kg torque. 50 KVA to 500 KVA
Supply RC network. 50 KVA to 500 KVA
Supply DPDT switch. 50 KVA to 500 KVA
Supply only sensing transformer.(16V/1V 12V/1amp) 50 KVA to 500 KVA
Supply only 12 pin connector(PCB) 50 KVA to 500 KVA
Supply only micro switch. 5 amp 50 KVA to 500 KVA
Supply only liver nilon/metel. 50 KVA to 500 KVA
Supply only gear assembly suitable size 50 KVA to 500 KVA
Supply only potentiometer. 50 KVA to 500 KVA
Supply only F push button switch for and high voltage 50 KVA to 500 KVA. Note: Ser Item No 1 to 64 Make: Volina/Lobotek/Sinetrac. Note:- (i) The installation & testing shall be carried out in the presence of rep of OEM and contractor has to submit test report duly signed by the rep of OEM & Engr-in-Charge. (ii) The contractor has to upload a concent letter on MoU from any OEM i.e. Volina/Lobotek/Sinetrac for the same failing which financial Bid will not be opened.
M&L for painting of Servo Voltage Stabilizer any capacity after cleaning the body surface of panel by rubbing with emery Paper to remove oil stains, dust etc and applying two coat of synthetic enamel paint by spray paint incl writing SM No/MES No as per existing pattern complete all as specified and directed by Engineer-in-Charge.
Dismantling APFC panel carefully removing the defective control device MCCBs/MCBs, capacitor cum push button switches, relays contacts, CTs, internal wiring, cleaning all parts by CRC solution/ emery paper as required and greasing the metallic and mechanical serviceable parts
Supply and fixing following parts S/F of capacitor suitable for up to 10 KVAR volts on panel mounted type including disconnecting the incoming/outgoing cable connections and reconnecting with suitable copper lugs/ferruls etc after taking out the existing u/s and making good the disturbed surface for the following capacity Make-L&T ,Simens, C&S:-
Same as item no 67 but Capacitor suitable for up to 05 KVAR Each.
S&F of APFC Relay 6 stage on panel mounted type including disconnecting the incoming/outgoing cable connections and reconnecting with suitable copper lugs/ferruls etc after taking out the existing u/s and making good the disturbed surface for the following capacity Make-L&T ,Simens, C&S:-
Same as item no 69 but APFC Relay 8 stage
S&F in repair Contractor ML-3 Coil on panel mounted type including disconnecting the incoming/outgoing cable connections and reconnecting with suitable copper lugs/ferruls etc after taking out the existing u/s and making good the disturbed surface for the following capacity Make-L&T ,Simens, C&S:-
same as item no 71 but Contractor MNX 40 A 3 Pole
same as item no 71 but Contractor MNX 25 A 3 Pole
S&F in repair Indicating Light on APFC Panel
M&L for burnt/UNSV Control wiring in Existing APFC panel in any capacity
Dehydration / filtration of voltage stablizer oil of volatge stablizer of various capacities installed at different locations in base hospital by disconnecting plants electrically for recirculation existing volatge stablizer oil with trolley mounted filtration plant till dielectric strength is up to 45 KV to 50 KV. Note- Quoted rates shall be deem to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) Transformer oil for topping up will be measured and paid in relevant item as required.
Supply & topping up of oil for volatge stablizer up to required level for voltage stabilizers of dielectric strength 50 KV & above all as per IS specification.
M&L for carrying out load balance distribution on LT side by checking the existing load on the feeder (3 phase, 4 wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load complete all as specified & directed. NOTE:- Contractor shall submit Earthing reports as per direction given by the Engr-in-Charge complete all as specified & directed, falling Which no Payment against this item shall be made .
M&L for pipe earthing (PIP) comprising of GI 80mm Dia x 3 Mtr with one bag of BFC (50 Kg) as per IS 3043-1987 tubing filled with jelly earthing compound duly inserted in soil boring of 100mm bore filled with back filled compound including fibre chamber cover 1x1feet openable type complete all as specified and directed. NOTE:- Contractor shall submit reports before load balance and after load balance as per format given by the Engrin-Charge complete all as specified & directed, falling Which no Payment against this item shall be made . and On testing after completion, if the earth resistance < 2 Ohms is not obtain earthing will be rejuvenated at no extra cost till the desired earth resistance is obtain.Make JMV/ SN Engineering/True Earthing
Dismantling following size cable armoured/unarmoured cutting burnt damaged portion of cable and replacement of lugs heavy duty Aluminium/copper and connecting in position including tighting cable gland including necessary excavation/earth work complete all as specified and directed:-
(a) Cable of size 2/4 core 16 Sqmm to 3.5 core 50 Sqmm
(b) Cable of size 3.5 core 70 Sqmm to 3.5 core 95 Sqmm
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 630 Sqmm single core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 240 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 185 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 150 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 120 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 95 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 35 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 25 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & laying in repair XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 10 Sqmm4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
S&F in repair cable jointing kit for 11 KV (HT), earth grade cable, outdoor termination, Heat shrinkable type joint complete, with jointing material and accessories, suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm, 3 Core complete all as specified and as directed.
S&F in repair cable jointing kit for 11 KV (HT), earth grade cable, Indoor termination, Heat shrinkable type joint complete, with jointing material and accessories, suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and as directed.
S&F in repair cable jointing kit for 11 KV (HT), earth grade cable, straight through, Heat shrinkable type joint complete, with jointing material and accessories, suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 Core complete all as specified and as directed.
S&F in repair cable jointing kit straight through, outdoor type, Heat shrinkable type joint complete, with jointing material and accessories, suitable for 1.1 KV (LT), XLPE insulated cable of size 70 Sqmm 3.5 Core to 120 Sqmm x 3.5 core complete all as specified and as directed.
S&F in repair cable jointing kit straight through, outdoor type, Heat shrinkable type joint complete, with jointing material and accessories, suitable for 1.1 KV (LT), XLPE insulated cable of size 25 Sqmm 3.5 core to 50 Sqmm x 3.5 core complete all as specified and as directed.
S&F in repair cable jointing kit straight through, outdoor type, Heat shrinkable type joint complete, with jointing material and accessories, suitable for 1.1 KV (LT), XLPE insulated cable of size 185 Sqmm x 3.5 core complete all as specified and as directed.
S&F in repair cable jointing kit straight through, outdoor type, Heat shrinkable type joint complete, with jointing material and accessories, suitable for 1.1 KV (LT), XLPE insulated cable of size 240 Sqmm x 3.5 core complete all as specified and as directed.
Arranging fault locating machine to locate the fault in underground elect power cable of any length & any type of 1100 volt grade LT cables & pin point the fault, it also include testing of the cable after locating fault and cutting the cable at fault to fixing the joint including excavation and earth work in any type of soil complete Note:- (i) Cable joints shall be measured and paid separately under respective of Sch 'A' (ii) If fault is not rectified within 24 hours after receving Message, the contaractor shall be charged penalty for Rs-500/-per hour and shall be deducted from his account during RAR
S&F in repair Off load change over switch of 630 Amp capacity, 4 pole by pass switch along with MS Enclosure made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick MS channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0630 or equivalent model of L&T/ Schneider/Legrand
S&F in repair Off load change over switch of 400 Amp capacity, 4 pole by pass switch along with MS Enclosure made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick MS channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0630 or equivalent model of L&T/ Schneider/Legrand
S&F in repair Off load change over switch of 200 Amp capacity, 4 pole by pass switch along with MS Enclosure made of 3.15 mm thick steel sheet Enclosure and extensible handle mounting stand made from 35 x 35 x 5mm thick MS channel, floor mounted and fixing in ground and necessary mounting accessories complete all as specified and directed. Make:- Havells Cat No IHCBFO0630 or equivalent model of L&T/ Schneider/Legrand
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed.
S& Laying sub class B bricks having minimum compressive strenth 75 Kg/sqm laid in trenches for cable protection etc complete all as directed.
S&F in repair/replacement MCCB 630 Amp Three pole, 50 KA Adjudtable thermal & fixed magnetic stting ICS 75% of Icu, suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make- Havells:IHLLFCT0630/L&T/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 630 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make Havells:IHLLNFC0630/L&T/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 400 Amp Three pole, 50 KA Adjudtable thermal & fixed magnetic stting ICS 75% of Icu, suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make- Havells:IHLLFCT0630/L&T/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 400 Amp four pole, 36 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make Havells:IHLLNFC0630/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 320 Amp four pole, 36 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make Havells:IHLLNFC0630/L&T/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 250 Amp four pole, 50 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make Havells:IHLLNFC0630/L&T/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 200 Amp four pole, 36 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make Havells:IHLLNFC0630/L&T/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S&F in repair/replacement MCCB 160 Amp four pole, 36 KA suitable for installation inside Panel including addition alteration to exeisting copper /aluminium busbar system all as specified and directed by Engr-in- charge. Make Havells:IHLLNFC0630/L&T/Legrand/Schinder/C&S Note:- (i) Quated rate include the addition/ alteration in busbar system.
S& F in repair 11 KV HT hand Gloves rubber insulated complete all as specified and as directed.
S& F in repair Combination pliers insulated with thick C.A Sleeve complete all as specified and as directed. Make -Taparia Product Code 1621-6 or Equivalent Model of Bosch/Jainson
S& F in repair long nose pliers insulated with thick C.A Sleeve complete all as specified and as directed. Make -Taparia Product Code 1430-6 or Equivalent Model of Bosch/Jainson
S& F in repair wire stripping pliers insulated with thick C.A Sleeve complete all as specified and as directed. Make -Taparia Product Code WS-06 or Equivalent Model of Bosch/Jainson
S& F in repair Universal Set (Adjustable Spanner, Insulated Pliers Screw Drivers) complete all as specified and as directed. Make -Taparia Product Code 1005 or Equivalent Model of Bosch/Jainson
S& F in repair Home tool kit complete all as specified and as directed. Make -Taparia Product Code 1021 or Equivalent Model of Bosch/Jainson
S& F in repair Allen Key set (10 Nos) complete all as specified and as directed. Make -Taparia Product Code AKI-10 or Equivalent Model of Bosch/Jainson
S& F in repair line tester complete all as specified and as directed. Make -Taparia Product Code 813 or Equivalent Model of Bosch/Jainson
S& F in repair screw driver set complete all as specified and as directed. Make -Taparia Product Code 840 or Equivalent Model of Bosch/Jainson
S& F in repair Pipe wrinch, 350 mm length, suitable for up to 40 mm bore pipes complete all as specified and as directed. Make -Taparia Product Code 1274 or Equivalent Model of Bosch/Jainson
S& F in repair 620 Watt Air blower complete all as specified and as directed. Make - Bosch Model No GBL 620-Watt or Equivalent Model of Stanley/Chasten/Karcher
S& F in repair power Crimping tool capacity up to 400 Sqmm with all die complete all as specified and as directed. Make : Jainson, Model JUPITER-400 or equivalent model of Dowells/Bosch
Supply & fixing in Replacement Sealed Maintenance Free 12V/65AH Batteries with suitable size terminal link for 30/10 KVA UPS.
S& F in repair Insulation Tester 200M ohm to 1000 M Ohm ACV 200 ohms continuity beeper short crcuit > 2.55mA, high driving current size 160x120x85(mm), 18mm large Display complete all as specified and as directed. Make : WACO Model No DI-6300 or equivalent model of BOSCH/TAPARIA
S& F in repair multimeter Multi function measurement : ACV, DCV, ACA, DCA OHM, Continuity Beeper, Transistor hFE, Diode Meet IEC safety requirement High accuracy in measuring RS232 PC interface, photo couple isolated circuit When apply the optional software, then the meter can be used as data logging, data recorder & other intelligent applications LCD display, clear readout even in high ambient light complete all as specified and as directed. Make : WACO Model No DM-9680 or equivalent model of BOSCH/TAPARIA
S& F in repair Measuring tools range Finder measuring range .05 to 50 meter complete all as specified and as directed. Make : BOSCH Model No GLM 50-27 CG or equivalent model of WACO/TAPARIA
S& F in repair 1000ACA Clamp Meter, NCV TEST Rubber Body, Display- 3 3/4 digit (3999 counts), DC Voltage -400mV-4V-40V-400V-600V, Accuracy+/- 0.5%, AC Voltage 400mV-4V-40V-400V-600V complete all as specified and as directed. Make : WACO Model No DM-9101 or equivalent model of BOSCH/TAPARIA
S& F in repair Earth Resistance Tester earth Resistance-19.99/199.9/1999, Earth Voltage- 0-199.9V, Size 160x120x85(mm) complete all as specified and as directed. Make : WACO Model No DI-6300 or equivalent model of BOSCH/TAPARIA
S& F in repair Power Clamp Meter, high power , watt resolution: min 10 Watt, Watt (AC, True,20 KW/100KW, ACA (200A,600A), AC 600V, DC 200V, 2 K Ohms, Diode, Size 230x74x38 (mm) complete all as specified and as directed. Make : WACO Model No PC-6010 or equivalent model of BOSCH/TAPARIA
S& F in repair Hammer Drill Reverse operation with extremely high torque for screwdriving operations, Overload clutch, Auxiliary handle with adjustable depth stop can be rotated 360 Degree, Ergonomically designed softgrip handle with long trigger variable speed control, Softgrip for a secure hold,Handle Type - Pistol Grip, Torque 18 Nm, Reverse Rotation Yes, No Load Speed 1000 RPM , Weight 2.3 kg ,Height 210 cm, Length 342 cm ,Width 73 cm, Maximum Power Output 620 W, Power Source Corded omplete all as specified and as directed. Make : BOSCH Model No GBH 2 -22 RE or equivalent model of DOWELL/TAPARIA
Vishal Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .