| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹88.1 LAccepted-AOC MCB Z 2 13519 ST NO 4 GREEN AVENUE BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹88.1 L | L-1 | Accepted-AOC Being lowest and reasonable. |
| 2 | L-2₹92.2 LRejected-Finance 64 SHAHEED UDHAM SINGH MARKET NEAR OLD BUS STAND BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹92.2 L | L-2 | Rejected-Finance Not being lowest bidder. |
| 3 | L-3₹93.9 LRejected-Finance 01 ENTERPRISES | ₹93.9 L | L-3 | Rejected-Finance Not being lowest bidder. |
| 4 | L-4₹1.1 CrRejected-Finance H NO 18 SHEET NO 5 A KATIA COLONY NAMDEV MARG BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹1.1 Cr | L-4 | Rejected-Finance Not being lowest bidder. |
| Sl No | Description | Qty | Unit | Singla Enterprises L3 | M/s PANKAJ KUMAR L2 | V K CONTRACTOR L4 | N.G BUILDERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level in any position complete all as specified and as directed by Engineer-in-Charge. | 300 | Cum | 150 ₹45,000 | 710 ₹2.1 L | 3,000 ₹9 L | 500 ₹1.5 L |
| 2.00 | Dismantling / Taking down structural steel i.e. rails mild steel joist,channel ,angle, or tee sections, of sloding hanger door including pully etc.complete all as specified and as directed by Engineer-in-Charge. Note: The weight of dismantled structural steel shall be ascertained through BOO as ordered by GE and payment shall be made to contractor accordingly. BOQ duly counter signed by GE shall be enclosed with RAR/ Final bill . | 6 | PER QUINTAL | 1,000 ₹6,000 | 600 ₹3,600 | 50 ₹300 | 300 ₹1,800 |
| 3.00 | Supply and Fixing Rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., of Fe 410 -W (Gde E- 250)quality A complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as speified and as directed by Engineer-in-charge. Note: The weight of Rolled mild steel shall be ascertained through BOO as ordered by GE and payment shall be made to contractor accordingly. BOQ duly counter signed by GE shall be enclosed with RAR/ Final bill . | 400 | Kg | 120 ₹48,000 | 130 ₹52,000 | 100 ₹40,000 | 160 ₹64,000 |
| 4.00 | Material and Labour for 75 mm thick PCC 1:3:6 , Type C-2 using 40 mm graded stone aggregate as in plinth protection, sub base finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in- charge. | 1,250 | Sqm | 200 ₹2.5 L | 255 ₹3.2 L | 200 ₹2.5 L | 220 ₹2.8 L |
| 5.00 | Material and labour for Pavement quality concrete (PQC) of minimum 28 days field Flexural strength of 45 Kg/ Sqcm or 4.5Mpa, aggregate gradation as per Table 3 of IRC 15-2017, coarse aggregate of clean, hard strong, dense, non- porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone sand or combination of both using minimum 360kg/cum of cement with non-circular, virgin synthetic fibre of 12-18mm length, specific gravity 1.34 to 1.39, UV stable , alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240 degree cetigrade and minimum tensile strength of 300 Mpa and at the rate as specified by manufacturer. PQC laid, spread and compacted with slip - form paver of minium 7.50m width, including curing and tining by Texturing cum Curing Machine complete all as specified and directed .Required surface texturing to be done as specified in Clause 10.1.14 and Table 9 of IRC:15-2017 complete all as specified and as directed by Engineer-in- charge. | 180 | Cum | 7,000 ₹12.6 L | 7,500 ₹13.5 L | 7,000 ₹12.6 L | 7,400 ₹13.3 L |
| 6.00 | Removing the existing sealing compound and widening of construction/ dummy joint 10mm to 12mm width of rigid pavement by using joint cutting machine up to a depth of 30mm , with cutting blade of appropriate size to make straight and smooth edge and removal of rubbish girt etc. using suitable tools including air compressor cleaning concrete debris washing etc. complete all as specified and as directed by Engineer-in- charge. | 10 | Ten RM | 1,200 ₹12,000 | 480 ₹4,800 | 200 ₹2,000 | 500 ₹5,000 |
| 7.00 | Removing the existing sealing compound in expansion and removal of girt etc. from the grooves of existing expansion joint of rigid pavement up to a depth of 45mm with suitable tools including air compressor to remove the loose particle , dust etc. complete all as specified and as directed by Engineer-in- charge. | 90 | Ten RM | 300 ₹27,000 | 340 ₹30,600 | 200 ₹18,000 | 700 ₹63,000 |
| 8.00 | Material and labour for providing and laying in position polysulphide (Pouring grade) sealant type FB conforming to BS 5212-1990 of approved brand by GE including painting the contact surface of the joints with polysulphide primer of approved brand by GE including expanded polyethylene armour rod in expansion joints 25mm wide x 10mm deep over 30mm dia expanded polyethlene armour rod complete all as specified and as directed by Engineer-in- charge. | 90 | Ten RM | 500 ₹45,000 | 600 ₹54,000 | 500 ₹45,000 | 500 ₹45,000 |
| 9.00 | Material and labour for providing and laying in position polysulphide (Pouring grade) sealant type FB conforming to BS 5212-1990 of approved brand by GE including painting the contact surface of the joints with polysulphide primer of approved brand by GE including expanded polyethylene armour rod in constuction joints 10mm wide x 30mm deep over with and including 12mm dia expanded polyethlene armour rod complete all as specified and as directed by Engineer-in- charge. | 10 | Ten RM | 500 ₹5,000 | 335 ₹3,350 | 500 ₹5,000 | 500 ₹5,000 |
| 10.00 | Material and labour for 4mm thick EPU flooring, providing and applying of self smoothening pigmented top coat of 2mm thick Epoxy polyurethane topping laid over with and including 2mm thick self smoothening screed over primer as per manufacturer's specification including preparation of surface complete all as specified and as directed by Engineer-in- charge. | 1,092 | Sqm | 2,100 ₹22.9 L | 2,050 ₹22.4 L | 2,500 ₹27.3 L | 1,800 ₹19.7 L |
Updated dates
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
28 Feb 2026, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda Bathinda Mil Stn
SPL REPAIR TO BLDG NO. P-1141 AGAINST JOB NO 81 SA/BTD/SR(P-1141)-01/2024-25) UNDER GE NORTH BATHINDA AT BATHINDA MIL.STN.
2025_MES_726260_2
CWE BTD/TOKEN-03/2025-26
Open Tender
Civil Works
300 days
Bathinda Mil Stn
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (N) Bathinda
₹1.8 L
HQ CWE Bathinda
29 May 2026
27 Jan 2026
2 Mar 2026
27 Jan 2026
28 Feb 2026
14 Feb 2026
6 Feb 2026
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15cm thickness below or above ground level in any position complete all as specified and as directed by Engineer-in-Charge.
Dismantling / Taking down structural steel i.e. rails mild steel joist,channel ,angle, or tee sections, of sloding hanger door including pully etc.complete all as specified and as directed by Engineer-in-Charge. Note: The weight of dismantled structural steel shall be ascertained through BOO as ordered by GE and payment shall be made to contractor accordingly. BOQ duly counter signed by GE shall be enclosed with RAR/ Final bill .
Supply and Fixing Rolled mild steel in Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., of Fe 410 -W (Gde E- 250)quality A complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as speified and as directed by Engineer-in-charge. Note: The weight of Rolled mild steel shall be ascertained through BOO as ordered by GE and payment shall be made to contractor accordingly. BOQ duly counter signed by GE shall be enclosed with RAR/ Final bill .
Material and Labour for 75 mm thick PCC 1:3:6 , Type C-2 using 40 mm graded stone aggregate as in plinth protection, sub base finishing the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in- charge.
Material and labour for Pavement quality concrete (PQC) of minimum 28 days field Flexural strength of 45 Kg/ Sqcm or 4.5Mpa, aggregate gradation as per Table 3 of IRC 15-2017, coarse aggregate of clean, hard strong, dense, non- porous and durable pieces of crushed stone or gravel, fine aggregates of clean natural sand or crushed stone sand or combination of both using minimum 360kg/cum of cement with non-circular, virgin synthetic fibre of 12-18mm length, specific gravity 1.34 to 1.39, UV stable , alkali resistant, with equivalent dia 15-40 micron, minimum melting temperature as 240 degree cetigrade and minimum tensile strength of 300 Mpa and at the rate as specified by manufacturer. PQC laid, spread and compacted with slip - form paver of minium 7.50m width, including curing and tining by Texturing cum Curing Machine complete all as specified and directed .Required surface texturing to be done as specified in Clause 10.1.14 and Table 9 of IRC:15-2017 complete all as specified and as directed by Engineer-in- charge.
Removing the existing sealing compound and widening of construction/ dummy joint 10mm to 12mm width of rigid pavement by using joint cutting machine up to a depth of 30mm , with cutting blade of appropriate size to make straight and smooth edge and removal of rubbish girt etc. using suitable tools including air compressor cleaning concrete debris washing etc. complete all as specified and as directed by Engineer-in- charge.
Removing the existing sealing compound in expansion and removal of girt etc. from the grooves of existing expansion joint of rigid pavement up to a depth of 45mm with suitable tools including air compressor to remove the loose particle , dust etc. complete all as specified and as directed by Engineer-in- charge.
Material and labour for providing and laying in position polysulphide (Pouring grade) sealant type FB conforming to BS 5212-1990 of approved brand by GE including painting the contact surface of the joints with polysulphide primer of approved brand by GE including expanded polyethylene armour rod in expansion joints 25mm wide x 10mm deep over 30mm dia expanded polyethlene armour rod complete all as specified and as directed by Engineer-in- charge.
Material and labour for providing and laying in position polysulphide (Pouring grade) sealant type FB conforming to BS 5212-1990 of approved brand by GE including painting the contact surface of the joints with polysulphide primer of approved brand by GE including expanded polyethylene armour rod in constuction joints 10mm wide x 30mm deep over with and including 12mm dia expanded polyethlene armour rod complete all as specified and as directed by Engineer-in- charge.
Material and labour for 4mm thick EPU flooring, providing and applying of self smoothening pigmented top coat of 2mm thick Epoxy polyurethane topping laid over with and including 2mm thick self smoothening screed over primer as per manufacturer's specification including preparation of surface complete all as specified and as directed by Engineer-in- charge.
Material and labour for repairs to the damaged concrete pavement using Epoxy mortar of Araldite grouting system (flowable)100:50:400 (100 parts by weight of Araldite GY 257 :50 parts by weight of Aradur 840 hardener and 400 parts by weight of quartz sand mix no.10) with necessary primer of 100:50,100 parts by weight of araldite 257GY 257 and 50 Parts by weight of aradur 840) coverage 4.0 Sqm per kg of mix and two top coats in ratio 100:50:15 parts by weight and aradur 850 Hardner) as per manufacturer's instructions using electrically operated concrete cutting machine chipping and levelling bottom, clenaing and removing all loose particle, grease, dust, rubbish and any other foregin materials with necssary liquids and final cleaning with heavy duty compressor etc. complete and protecting the area with barricades whenever necesary till operation complete all as specified and as directed by Engineer-in- charge.
Demolition of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing rubbish material from the site to a distance not exceeding 100.00 metre and deposite complete all as specified and as directed by Engineer-in-charge.
Material & Labour for glazed ceramic coloured tiles 350mm x 250mm x 7mm / 450mm x 350mm x 7mm in verticle surface as in dado / skirting with and including 10mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured expoxy grout to match the shade of tile including necessary cutting as per site requirement etc complete all as specified and as directed by Engineer-in-charge.
Material and Labour anti slip coloured ceramic tiles 7 to 8mm thick (square/rectangular) of Size 400mm x 400mm in floors with and including 10 mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in white or coloured epoxy grout to match the shade of tile including necessary cutting as per site requirement complete all as specified and as directed by Engineer-in-charge.
Material and Labour for providing and laying Premium (1st quality) straight edge,Stain free, glooss finish, Square Double charged vitrified tiles size in 600mm x 600mm x 9mm to 10mm thick as in floors etc. shade as approved by GE , set and jointed with using spacer and approved High polymer modified, grey cement-based tile adhesive suitable for fixing medium format tile/stone in walls/floor conforms to IS 15477 : 2019 type 2T “Adhesives for use with Ceramic, Mosaic and stone Tiles” Conforms to EN 12004: 2017 and is a normal cementitious adhesives (C1) with slip resistance (T) of class C1 and necessary grouting as per manufacturer’s instruction, completed all as specified and directed by engineer-in-charge
Material and Labour for providing and laying Premium (1st quality) straight edge,Stain free, glooss finish, Square Double charge vitrified tiles size in 600mm x 600mm x 9mm to 10mm thick as in skirting surfaces shade as approved by GE , set and jointed with using spacer and approved High polymer modified, grey cement-based tile adhesive suitable for fixing medium format tile/stone in walls/floor conforms to IS 15477 : 2019 type 2T “Adhesives for use with Ceramic, Mosaic and stone Tiles” Conforms to EN 12004: 2017 and is a normal cementitious adhesives (C1) with slip resistance (T) of class C1 and necessary grouting as per manufacturer’s instruction, completed all as specified and directed by engineer-in-charge.
Supply and Fixing in repairs vitreous china wash basin,countersink in granite slab, white, size 550mm x 400mm including brackets ,32mm dia waste coupling fancy type chromium plated and PVC waste pipe of 32mm dia complete all as specified and as directed by Engineer-in- charge. Note: Granite slab shall be measured and paid seperately under appropriate item of Schedule'A' BoQ.
Material and labour for Forming 20mm thick Expansion joints in 100mm thickness of concrete slab filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’complete all as specified and directed by Engineer-in- charge.
Material and labour for marking on runway/heli runway pad/pavements, like lines,dashes,arrows,letters or figures etc. with hot applied retro reflective thermoplastic road marking paint ( in any colour as directed like white ,golden,yellow, orange, black etc.) conforming to MORT& H (Clause 803.4) with 8% glass beads using special applicator machine with heating arrangement up to 160 degree 'C' including cleaning and drying the existing road surfaces and remove dust,oil,grease and moisture before appling the paint complete all as specified and directed by Engineer-in- charge.
Taking down , removing of existing door panel of approximate size 4.00 mtr x 8.00 mtr , approximate weight 2000 Kg and and refixing the same after greasing, oiling , easing, including necessary welding , repair and proper functioning complete all as specified and directed by Engineer-in-charge.Note: The Hanger door shall be taking down, remove, repaire and refixe by the specialised firm which have experience of minimum 05 years in relavant field .The firm shall be approved by GE in writting before execution of work.
Supply and Fixing Rolled mild steel rolling device suitable for heavy weight sliding gate including pully, ball bearing,wheel ,cantilever wheel etc. doors to be prepared for hanging or sliding with and including either hooks or hinges or steel hanging door fiting , fastning fixing, steel rail, locking arrangements and other fittings as directed for smooth functioning of sliding gate to sliding system upper and ground rails complete all as specified and directed by Engineer-in-charge.The weight of Rolled mild steel shall be ascertained through BOO as ordered by GE and payment shall be made to contractor accordingly. BOQ duly counter signed by GE shall be enclosed with RAR/ Final bill .
Material and Labour for preparation of steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and as directed by Engineer-in-charge.
Material and Labour for preparation of old painted steel surfaces of any description not otherwise described over 10 cm width & girth by applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer-in-charge.
Supply and Fixing AZ-150 Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engineer-in-charge.
Supply and Fixing AZ-150 Pre- painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 2.00mm thick Polycarbonate sheet, UV- Resistant, with AZ-150 coated substrate fixed with coach screws and washers in roof,wall etc. complete all as specified and directed by Engineer-in-charge.
Material and Labour for form work to soffits and sides of Chajjas on flat fair finished surfaces of concrete complete all as specified and directed by Engineer-in-charge.
Material and labour 18-20mm thick machine cut, granite duly factory grinding and polished (table rubbed and polished) of approved colour for counter sunk wash basin, plateform/cooking plateform or as directed, including screed bed 15mm thick in cement mortar (1:4) (grey cement slurry) including pointing in white cement (1:2) using marble dust with admiture of pigment to match with shade of granite stone slab including cutting as required including cleaning and extra polishing if required complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkhats or frames with shutters of PVC door , wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed by Engineer-in- charge.
Taking down chowkhats or frames with shutters of PVC door ,wooden door shutter, wooden window shutter , Mild steel window and Mild steel ventilators (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 Sqm each complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame /cupboard frame/ Chowkhat of Size 45mm x 70 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply & fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges with and making good with plastering/rendering etc. around the finished opening of the distrubed surface with Cement Mortar 1:4 complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat with double rebate of Size 65mm x 125 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply & fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges with and making good with plastering/rendering etc. around the finished opening of the distrubed surface with Cement Mortar 1:4 complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt with Stainlessd steel screws and including Supply & fixing of 02 Nos SS 150mm long handle with Stainlessd steel screws and 300 mm SS sliding door bolt with Stainlessd steel screws complete all specified and directed by Engineer -in-charge. Note:- The rate of 02 Nos. SS 150mm long Tower Bolt . 02 Nos. SS 150mm long handle and 300 mm SS sliding door bolt is included in this item and nothing shall be paid extra on this account.
Supply & fixing Factory Made 30mm thick Solid WPC ( Wood polymer Composite ) Wiremesh Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension rade ), calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cum , having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter for supply and fixing Mosquito mesh and XTN aluminium mesh together on panel area of door except stiles and rails to be panelled with and including mesh with self tapping round headed scresws at required distance, screws and edges covered with feathered pvc edge beading all around of mesh and supply and fixing stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws with and including 03 Nos. door Stainless steel butt hings 100mm long with Stainlessd steel screws for each , 02 Nos. stainless steel barrel tower bolts of extruded section 150mm long (ISI marked), 2 Nos. stainles steel handles 125 mm long, (ISI marked) , 01 No. of helical door spring of 300 mm length complete all as specified and as directed by Engineer-in-charge. Note: 1. Material test certificate of all the items and authentication should be compulsory provided by the manufacturing company. 2. The rate of 03 Nos. door Stainless steel butt hings 100mm long with Stainlessd steel screws , 02 Nos stainless steel barrel tower bolts of extruded section 150mm long (ISI marked) with Stainlessd steel screws , 2 Nos. stainless steel handles 125 mm long, (ISI marked) with Stainlessd steel screws , 01 No. helical door spring of 300 mm length is inclusive in this item and nothing shall be paid extra on this item.3. The rate of Mosquito mesh and XTN aluminium mesh is included in this item and nothing shall be paid extra on this account.
Supply and fixing of factory made uPVC white colour Three track Slider Window including glass & mesh of area exceeding 2.00 sqm each window made of extruded profiles of high impact modified grade manufactured from Tropicalized Blend with TiO2 and required additives, colorfast & being able to withsatand a weather resistance test of 16000 hrs on weathering apparatus, resistant to chemicals, and be fungal and vermin proof. The uPVC profile should be classed as self extinguishing to prevent support or enchancement of accidental fires. Extruded profile duly reiniforced with minimum 120 gsm zinc coated GI of 1.5mm to 2.5mm thickness to meet the wind load requirement on sash/mulilion and fitted in continuous length in closed chamber of required length (shape and size according to uPVC profile design). The internal drainage shall be isolated from chambers into which reinforcement can be placed or through which frame fixing passes. Drainage shall be either through the base or alternatively to the face, concealed by face drainage caps. uPVC systems must be fabricated with fusion welded corners and uPVC extruded glazing beads of appropriate dimensions with EPDM/TPE Gaskets. All hardware fitted must be of stainless steel, multipoint espag, plastic packers, plastic caps & necessary stainless steel screws, except handles to be of Zinc/Al alloy casted with powder coated, GI fasteners 100mm x 8mm size for fixing frame to wall. Outer frame of windows 118mm x 50mm , sash 45mm x 60mm consisting of multi chambered frame, sash 7 mullion/transom (wherever required), The sizes of the sections indicated are minimum and no additional cost shall be claimed for use of higher sections due to design considerations. The wall thickness of the profile shall be minimum 2.0 ± 0.2mm. The sheet glass shall be toughened of thickness 5mm. The wire mesh shall be of stainless steel stainless 0.36mm nominal dia of wire and average width of aperature 1.40 mm. After fixing the frame the gap between the frame and adjacent finished wall shall apply Silicon sealant to make joint, water proof of approved quality. There would be a conditional warranty of minimum 10 years on profile & 02 years on hardware from the date of completion. The uPVC system must be installed by profile manufacturer or their authorised agents only complete all as specified and as directed by Engineer-in- charge. (Note :- The rate of 5mm thick toughened glass for glazing and stainless steel wire mesh cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm is included in this item and nothing shall be paid extra on this account. Net opening will be measured for payment purpose.)
Supply and fixing of factory made uPVC white colour Louvered Casement Window / Ventilator of area not exceeding 1.00 Sqm each window made of extruded profiles of high impact modified grade manufactured from Tropicalized Blend with TiO2 and required additives, colorfast & being able to withsatand a weather resistance test of 16000 hrs on weathering apparatus, resistant to chemicals, and be fungal and vermin proof. The uPVC profile should be classed as self extinguishing to prevent support or enchancement of accidental fires. Extruded profile duly reiniforced with minimum 120 gsm zinc coated GI of 1.5m to 2.5mm thickness to meet the wind load requirement on sash/mulilion and fitted in continuous length in closed chamber of required length (shape and size according to uPVC profile design). The internal drainage shall be isolated from chambers into which reinforcement can be placed or through which frame fixing passes. Drainage shall be either through the base or alternatively to the face, concealed by face drainage caps. uPVC systems must be fabricated with fusion welded corners and uPVC extruded glazing beads of appropriate dimensions with EPDM/TPE Gaskets. All hardware fitted must be of stainless steel, multipoint espag, plastic packers, plastic caps & necessary stainless steel screws, except handles to be of Zinc/Al alloy casted with powder coated, GI fasteners 100mm x 8mm size for fixing frame to wall. Outer frame of windows 45mm x 50mm , with fixed frosted glass in the lower half, 4mm thk glass pinhead louvers in the upper half and Mesh consisting of multi chambered frame, sash & mullion/transom (wherever required), The sizes of the sections indicated are minimum and no additional cost shall be claimed for use of higher sections due to design considerations. The profile of the frame shall be suitable to install and fix mild steel guard bars. The wall thickness of theprofile shall be minimum 1.8 to 2.3 ± 0.2mm. The sheet glass shall be toughened of thickness 5mm. The wire mesh shall be of stainless steel stainless 0.36mm nominal dia of wire and average width of aperature 1.40 mm. After fixing the frame the gap between the frame and adjacent finished wall shall apply Silicon sealant to make joint, water proof of approved quality. There would be a conditional warranty of minimum 10 years on profile & 02 years on hardware from the date of completion. The uPVC system must be installed by profile manufacturer or their authorised agents only complete all as specified and as directed by Engineer-in- charge. (Note :- The rate of 5mm thick toughened glass for glazing, 4mm thick pinhead glass and stainless steel wire mesh cloth 0.36mm nominal dia of wire and average width of aperature 1.40 mm is included in this item and nothing shall be paid extra on this account. Net opening will be measured for payment purpose.)
Supply and fixing Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 as in approved design/ pattern, approved standard section as approved by GE and fixed to window frame with stainless steel screws complete as pr requirement complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with overall length of cover plate 150mm complete all as specified and as directed by Engineer-in- charge.
Supply and fixing Aluminium (extruded section body) Door closer hydrau lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixedcomplete all as specified and as directed by Engineer-in- charge.
Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed by Engineer-in- charge.
Supply and fixing GI powder coated frame work 605mm x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20mm and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre and duly suspended with 4mm GI wire hangers (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made of GI flat 40mm x 3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including providing 600mm x 600mm x 6mm-7mm thick board in false ceiling with aluminium profile sheet on top side and PVC profile sheet on bottom side fixed in girid as per manufacturer's instructions complete all as specified and as dirercted by Engineer-in-charge.Note: The rate of ceiling mineral fibre board size 600mm x 600mm x 6mm-7mm thick is included in this item and nothing shall be paid extra on this account.
Supply and fixing hollow PVC Lining consisting 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on with and including PVC frame complete all as specified and as directed by Engineer-in-Charge.
Taking down cement or cement lime plaster from brick wall etc including racking out joints, hacking for key & scrubbing down with water etc including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance exceeding 500 metres and not exceeding 1.5 Kilometre away from the site complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing to wood or steel members Welded steel wire fabric weight not exceeding 4.00 Kg per Sqm complete all as specified and as directed by Engineer-in-Charge. The weight of welded steel wire fabric shall be ascertained through BOO as ordered by GE and same duly counter signed by GE enclose with final bill.
Material and Labour for rendering 10 mm thick in cement mortar 1:3 on concrete surfaces as in ceiling and finishing the surface even & smooth complete all as specified and as directed by Engineer-in- charge.
Material and Labour for 25mm average thick PCC padding in 1:2:4 Type B-1 (using 20mm graded stone aggregates) as in roof slab finishing the surface even and fair using Liquid water proofing compound complete all as specified and directed. Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule 'A' BoQ.
Material and Labour for Water proofing tratment to existing roof / terrace (material of water proof treatment as approved by GE) Single component, acrylic based, flexible, micro fibre reinforced waterproofing and heat reflective coating system. the treatment shall be carried out as per the manufacturers instructions and shall include the followings: (a) Preparation of substrate and cleaning it off all loose and triable by mechanical means (b) Open the cracks lines to form , V grooves with cutter/hammer/chisel up to 5-10mm and filling with crack filler and PU sealant. (c) application of primer coat @ 0.2 to 0.3 kg/ sqm followed by the first coat @ 0.75kg/ Sqm. (d) The second coat shall be applied @ 0.75 kg / Sqm and reinforced with fabric re-inforcement between the first and second coat. (e) The top coat of primer shall be applied after the second coat dries off @ 0.05-0.08 Kg per Sqm. (f) The material shall adhere to following specification. TECHNICAL SPECIFICATION OF MATERIAL Tensile Strength 1.5 MPa ASTM D412 Elongation at Break > 200% ASTM D412 Adhesion in Peel > 1.5 MPa (on concrete substrate) EN 1542 Crack Bridging Ability Passes upto 3.2mm Width ASTM C1305 Permeability to Water Vapour Passes IS 2645 Water Vapour Transimission ~ 23 g/m²/24hr ASTM E96 Water Absorption < 10% ( by Mass) ASTM D570 Microbiological Resistance No Algae & Fungal Growth ASTM D5590 Solar Reflectance Index 102 ASTM E1980. Note : Complete material shall be approved by GE and procured in bulk and kept in lock and key. Note : The installation company should be trained and authorized by Manufacturer & installation to be carried out as per manufacturers approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacturer as a part of system. Any component used which is not manufactured by the particular manufacturer can only be used with official approval from manufacturer in consultation with GE.
Supply only Liquid water proofing compound complete as per manufacturer's instructions and directed by Engineer-in-charge.
Supply and Fixing 16 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 15mm bore complete complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing 20 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 20mm bore complete complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in repair vitreous china wash down water closet pan (pedestal pattern, EWC) P Trap white clour , including connection to drain etc., including plastic water closet seat with cover (white clour) closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device including stainless steel chromium plated jet spray with 01 mtr long PVC pipe with CP connector and necessary nut bolts and with necessary CP screws and plug for fixing WC complete all as specified and as directed by Engineer-in- charge.
Supply and fixing in replacement 10 litres capacity PVC valveless syphonic action type low level flushing cistern white with inlet, ball valve, float, handle including brackets and 32mm dia PVC flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement health faucet chromium plated suitable for 15 mm dia pipe with 1.00 metre long flexible tube and wall hook including making connections and fixed in position complete all as specified and directed by Engineer-in-charge.
Supply and Fixing 110 mm dia PVC SWR Type-B, Floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1, using 20mm graded stone aggregates complete all as specified and as directed by Engineer-in-charge.
Supply & fixing in repairs 15mm bore fancy bib taps, chromium plated ,cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement 15mm bore stop cock /angle valve cast copper alloy, chromium plated fancy type screwed down high pressure with crutch or butterfly handle, screwed both ends suitable for iron pipe complete, all as specified & directed by Engineer-in-charge.
Supply and fixing in repairs Brass chromium plated Tubular towel rail, 20mm dia , D type, 60 cm long between flanges complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in replacement Table Top / couner top vitreous china one piece wash hand basin size 700mm x 460mm x 200mm including accessories approved by Garrison Engineer complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repairs 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plqated, fancy type, swan neck ,screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engr In Charge
Supply & fixing in repairs Rotational Moulded Polyethylene water storage tank ISI Marked of capacity 1000 litres (cylindrical vertical, with closed top), hoisted and fixed in position including making inlet and out let connection complete all as specified and as directed by Engineer-in-charge. (Note :- Ball valve and gate valve shall be measured & paid separately under appropriate items of Schedule 'A' BoQ.)
Supply and Fixing Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge.
Supply & fixing Gun metal, globe or gate valve (ISI marked), brass cast copper alloy, with iron wheel head, screwed both ends suitable for 25mm bore iron pipes complete all as specified and as directed by Engineer-in-charge.
Supply & fixing vitreous china urinal, half stall type of size 345mm x 320mm x 560mm , white, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, 32 mm dia full threaded PTMT waste coupling (excluding flushing cistern and flush pipe ) and pointing around urinal back in cement mortar,complete all as specified & directed by Engineer-in-charge.
Supply & fixing 110 mm bore of pipe PVC (SWR) type B ring fit pipes single socket in any length with and including clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 of stays to wall at a distance of 100-120mm away from walls with and including Taking down old Cast iron rainwater pipes ( of any size and pattern) including all fittings, compete all as specified and as directed by Engineer - in-charge.
Supply & fixing 110 mm bore, PVC (SWR) fittings Type -B bends of any radius complete all as specified and as directed by Engineer - in-charge.
Supply & fixing 110 mm dia PVC type B (SWR) branch fittings Type -B piece, single (single Y) equal or unequal branch piece single ( equal or unequal), ordinary or inverted or with parallel branches complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work masonry, built in cement mortar including all quoins, arches, pillars, etc, complete all as specified and as directed by Engineer-in- charge.
Material and Labour Brick work with sub class ‘B’ burnt clay old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and as directed by Engineer-in- charge.
Material and Labour for Preparation of internal ceiling surfaces with and including applying 02 coats of Interior Acrylic Emulsion Paint (shade as approved by GE ) @ 10.00 Sq.m / litre / 2.00 coats by using roller / brush over with and including one coat of Interior Acrylic Emulsion Primer @ 10.00 Sq.m / litre / 1.00 coat as recommended for under coat by manufacturer of Interior Acrylic Emulsion by using the brands of Interior Acrylic Emulsion Paint and Interior Acrylic Emulsion Primer as described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and Labour for Preparation of internal surfaces of walls with and including applying 02 coats of Interior Acrylic Emulsion Paint (shade as approved by GE ) , @ 10 Sq.m/ litre / 2.00 coats by using roller over with and including one coat of Interior Acrylic Emulsion Primer @ 10.00 Sq.m / litre / 1.00 coat by using roller as recommended for under coat by manufacturer of Interior Acrylic Emulsion by using the brands of Interior Acrylic Emulsion Paint and Interior Acrylic Emulsion Primer as described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder complete all as specified and directed by Engineer-in- Charge.
Material and Labour for applying Acrylic wall care putty on internal surfaces and external surfaces of walls/ceilings/soffits (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and leveling of surfaces in two or more layers) by using ready made acrylic wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed by Engineer-in- Charge. Make of acrylic wall care Putty : AS described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after. Notes : (i) The prepared surface after wall putty, the contractor will inform to the GE as well as to the Engineer-in-Charge for site inspection before applying further finishes. Please note that the further finishes work will start only after approval of the prepared surface from the GE as well as to the Engineer-in-Charge through site order. (ii)The make of acrylic wall care putty shall be as per the recommendation of manufacturer of paint.
Material and Labour for preparation of surface applying 02 coats of Exterior Acrylic Emulsion Paint (shade as approved by GE) with highlighter of any approved shade, @ 5.00 Sq.m / litre / 2.00 coats by using roller to external walls/ RCC surfaces / soffits of chajjas / roof projections / cantilevers / balcony etc surfaces over with and including one coat of Exterior Acrylic Emulsion Primer @ 11.00 Sq.m / litre / 1.00 coat by using roller as recommended for under coat by manufacturer of Exterior Acrylic Emulsion by using the brands of Exterior Acrylic Emulsion Paint and Exterior Acrylic Emulsion Primer as described in LIST OF MAKES/MANUFACTURERS under Appendix 'B' here-in-after complete all as specified and directed by Engineer-in- Charge.
Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade colour and pattern as approved by GE with grey cement and no pigment complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for 25mm thick Sand filling under interlocking tiles including watering and consolidation complete all as specified and as directed by the Engineer-in-Charge.Note: Sand shall be approved by GE before incorporation in the work.
Demolition of RCC of any description and any position not otherwise specially provided and including removing rubbish material from building and thrown in low lying empty area (as per direcction of AGE/JE) at any distance exceeding 500 metres and not exceeding 1.5 Kilometre away from the site complete all as specified and as directed by Engineer-in-Charge..Note:The weight of scrap iron for schedule of credit shall be ascertain by BOO as ordered by GE.The copy of BOO duly countersinged by GE shall be enclosed with final Bill.
Material and labour for reinforced cement concrete (1:2:4) (nominal mix) type B-1 using 20mm graded stone aggregate as in chajjas, Lintels, etc. complete all as specified and as directed by Engineer-in-Charge. (NOTE : Reinforcement shall be measured and paid for separately under appropriate item of this schedule.
Material and labour for mild steel TMT bars 6mm to 8mm dia , cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia including making of rungs, handles etc complete all as specified and as directed by Engineer-in-charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.)
Taking down carefully copper /aluminium point wiring (light, fan, socket , bell point, power point ) complete including fitting such as hylem , sheet switches, socket out lets , fan regulators , bell push switch , Electronic bell , Batten holder , ceiling rose, , sunken box, except concealed conduit etc. complete all as specified and directed by Engineer-in-charge. Notes: (i) The weight of aluminium scrap ,copper scrap and iron scrap (sunken box) shall be ascertain by BOO as ordered by GE and accordingly shall be taken on charge.The copy of BOO duly countersinged by GE shall be enclosed with final Bill. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface shall be measured and paid seperately under serial item nos.86.00, 87.00,88.00,89.00 & 90.00 of BoQ.
Material and Labour for Concealed point wiring for modular type fittings using approved colour coding as per IS (Red, Black and Green for single phase circuits), with two single core 2.5 Sqmm nominal cross sectional area single core PVC insulated, unsheathed 'multi stranded' FRLSH copper cable, 1100 volts grade,ISI Marked with multi stranded copper conductor drawn through with and including non-metallic, rigid non mettalic PVC conduit (medium grade) 20mm bore surface on wall / ceiling with and including one single core 2.5 sqmm PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable ISI Marked as continuous earth continuity conductor (green in colour) including modular metal flush box concealied with front & modular cover plate with frame suitable matching colour of required module for mounting or housing modular switches 5Amp/ 6Amp , modular socket outlets 5 Amp / 6Amp, modular fan regulators, etc. including blanking plates & all other fixing accessories for one light/fan point controlled by one 5/6 Amps modular switch and including cutting chases (as required) and making good surfaces to match with adjoining surface complete all as specified and as directed by Engineer-in- charge Note for serial item no.86.00, 87.00,88.00,89.00 & ,90.00 : The quoted unit rate is deemed to be inclusive of cost of metal flush boxes, modular white cover plates, modular frame plates and flush fixed with cement mortar 1:4 etc.However modular switches 5Amp/ 6Amp , modular sockets out let 5Amp/ 6Amp and modular bell push switch 5Amp/ 6Amp shall be measured and paid seperately under respective items of Schedule'A' BoQ. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface is included in this item and nothing shall be paid extra on this account. (iii) All wires going into SP, SPN, TPN, MCCB shall be done with copper lugs of adequate size.
All as per item No 86.00 here- in -before but for one 3/5 Pin, modular Socket outlet 5 Amp, on same board complete all as specified and as directed by Engineer-in- charge.
All as per item No 86.00 here- in -before but for one 3/5 Pin, modular Socket outlet 5 Amp, on independent board complete all as specified and as directed by Engineer-in- charge.
All as per item No 86.00 here- in -before but for one 3/5 Pin, modular Socket outlet 15 Amp, on independent board complete all as specified and as directed by Engineer-in- charge.
All as per item No 86.00 here -in- before but for One bell/buzzer point controlled by one modular push button complete all as specified and as directed by Engineer-in- charge.
Supply & Fixing Modular switch one way 6A, 1 module, complete all as specified and as directed by Engineer-in-charge. Note: .(i) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Socket Outlet , Multipurpose,3/5 Pin, 6 Amp , 2 Module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: .(i) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Socket Outlet , Multipurpose,2 in 1,6 Pin, 6/16 Amp , 2 Module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Switch one way 16 Amp 240 Volt, AC ,1 Module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Modular Bell push Switch 6A 1 module , ISI Marked complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Electronic Bell, ding dong type 230 Volt AC supply, complete all as specified and directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply & fixing Batten holder polycarbonate cased body (B22 base), top line series, with back plate with and including LED Bulb 9/10 Watt B22 Base 100Lm/W,6000K complete all as specified and as directed directed by Engineer-in- charge. Notes: (a) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account. (b) Contractor has to furnish a replacement warranty of 02 years for LED Bulb complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact.
Supply & fixing ceiling rose surface type polycarbonate isolated body two to three terminal , Top line series 20x50mm, 6 amps three terminal complete all as specified and as directed by Engineer-in- charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.85.00 of BoQ here-in -before and nothing shall be extra paid on this account.
Supply and fixing Recessed mouned LED ceiling light with wide light window for maximized glare free output suitable for 600mm x 600mm and ceiling fitting with separate electronic driver and high brightness LEDs 36W(100 Lumens per watt), not less than 5700 K including complete as per manufacturer's instructions & electrical connection to the light fitting with twin core round copper conductor cable of suitable size and testing complete all as specified and as directed by Engineer-in- charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include to fix LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) The rate of electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector is included in this item and nothing shall be paid extra on this account.
Supply and Fixing wall mounted LED batten fitting 1 x 20 watt, 6000K, min 100 Lumen per watt, 4 feet complete with decorative ultra slim, square profile linear LED lighting fixture with extruded polycarbonate, enviroment friendly, energy efficient complete as per manufacturer's instructions with and including connection with flexible twin core copper cable of size 23/.00076 from ceiling rose to fitting complete all as specified and as directed by Engineer-in- charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include to fix LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) The rate of electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector is included in this item and nothing shall be paid extra on this account.
Supply and Fixing in replacement LED street light fitting 25 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection complete all as per manufacturer's instructions with and including bracket made out with 40mm bore Galvanised Iron Light grade pipe 1.20 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with and including connection with copper cable of suitable size from ceiling rose to fitting complete all as manufacturer's instructions , complete as specified and as directed by Engineer-in-charge. Notes: (a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including lamps from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :- (i) Manufacturing defects. (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include to fix LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) The rate of electric connection connecting with using flexible copper wire twin core upto ceiling rose/connector is included in this item and nothing shall be paid extra on this account.
Supply and Fixing ( Concealed in wall or as directed) Single pole and neutral sheet metal enclosure (AC Box) with a two pin and eath plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC Supply complete all as specified and as directed by Engineer-in- charge.
Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB V TPN 4 way, 415 V AC with 200 Amps rated copper bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ.
Supply and fixing in replacement (concealed flush to wall) factory made DB (made out of CRCA sheet not less than 1.2mm thick, fitted with DIN channel neutral link and 200 Amp rated copper bus bar) SPN, 12 Way 240V, suitable for mounting MCB/Isolator etc, conforming to IS-13032, DB shall be semi glosy finished with epoxy polyster based powder paint sprayed and backed at high temperature between powder paint process to ensure smooth finish and protection against corrosion atmosphere. The DB shall be double door type with hinged door with locking arrangement, the DBs shall be same make as MCBs, DB shall be provided with level marking indicating the incoming and outgoing circuits on always as specified. The DBs shall be of IP-54 protection class, and including making good disturbed surfaces of walls as necessaty complete all as specified and directed by Engineer-in-charge. Note :- MCB/Isolator etc shall be measured and paid separately under appropriate item of BOQ.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 05 to 32 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.108.00 & 109.00 of BoQ here-in -before of BoQ here-in -before whereas applicable nothing shall be extra paid on this account.
Supply and Fixing MCB SPN 40 Amp to 63 Amps, 10 KA, ‘C’ Curve, 230 V AC,50 Hz including necessary attachment complete all as specified and as directed by Engineer-in- charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.108.00 & 109.00 of BoQ here-in -before of BoQ here-in -before whereas applicable nothing shall be extra paid on this account.
Supply and fixing MCB ‘C’ curve suitable for 230 volts AC supply, 40 Amps, SP with over load and short circuit protection and rupturing capacity not less than 10 KA complete all as specified and as directed by Engineer-in-charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.108.00 & 109.00 of BoQ here-in -before of BoQ here-in -before whereas applicable nothing shall be extra paid on this account.
Supply and Fixing MCCB 4 pole of rating 125 Amp, Icu -100% 25 KA, thermal magnetic based complete all as specified and as directed by Engineer-in- charge. Note: (i) Labour element for taking down old unservicable material is included in serial item no.108.00 & 109.00 of BoQ here-in -before of BoQ here-in -before whereas applicable nothing shall be extra paid on this account.
Supply & Fixing Ceiling fan of 1200mm sweep complete with blades, down rods, including with remote control and accessories, 230 Volts, single phase, 50 Hz, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current (BLDC) motor connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of suitable size from ceiling rose / connector, including extra GI / MS pipe down rod, as per site requirement , with and including serial number of fan as issued by Engineer-in-charge and GE office name with red colour permaent marker complete all as specified and directed.
Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and Labour for earthing complete with copper plate electrode 600mm x 600mm x 3.15 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to with and including 20mm x 3mm copper strip as earth lead by means of copper bolts, nuts, check nuts and washers , with and including GI protection pipe 40mm bore GI light grade pipe up to test point or up to main swith board , HT/LT equipments, fixing with 02 Nos.nuts and bolts and protection pipe fixed and including flat iron clamps, bolts, nutsand washers. Earth plate shall be surrounded by alternate packet layer 15cm thick of charcoal or coke and commont sal all around bottom and top with and including 20mm GI medium grade pipe for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of with copper strip 20mm x 3mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
Material and Labour for Test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw compete all as specified and directed by Engineer-in-charge.
Material and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire connecting to earthing between earthing and MCCB/MCB DB compete all as specified and directed by Engineer-in-charge.
Supply and fixing GI tubing, light grade 40 mm bore complete with all fittings for cable protection, fixed along poles or laid under floor , laid in trench ,under road and hardstanding etc. and making good after laying of cable complete all as specified and as directed by Engr - in- Charge.
Supply and fixing GI tubing, light grade 50 mm bore complete with all fittings for cable protection, fixed along poles or laid under floor , laid in trench ,under road and hardstanding etc. and making good after laying of cable complete all as specified and as directed by Engr - in- Charge.
Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 50 Sqmm 3.5 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable , water supply pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in- charge.
Returning filling in, in any kind of soil, including spreading , levelling, watering and well ramming in layers, each layer not exceeding 25cm in soft/loose soil complete all as specified and as directed by Engineer-in- charge.
Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
Removing excavated material(soil) n exc 50m and depositing where directedc at a level n exc 1.5 mtr above the starting point in soft/loose soil. complete all as specified and directed by Engr- in- charge.
Supply and Fixing exhaust fan, Heavy steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed by Engineer-in-charge.
Making holes for 300 mm dia exhaust fan of suitable shape and size into or through brick walls at ground/ First/Second floor including plastering for making good to the original surfaces of any description disturbed including painting / distemper matching with existing colour. Note : Rates are deemed to be icludd charges of any type of T & P, inssurane of staff deployed at site.
Note for serial item nos. 85.00 to 130.00 of BoQ:- 1. All old unservicable material obtained from serial item nos.85.00 to 130.00 shall be deposited in the store yard of AGE EM GE North Bathinda by the contractor at his own arrangment. Nothing shall be paid extra to contractor on this account.The Board of Officer as ordered by GE (North) Bathinda shall be ascertained the quantity of old unservicable material and shall be depostied accordingly . 2. The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 4.28 MB
8103Tender.pdf
Tender Documents • 2.22 MB
BOQ_840008.xls
BOQ • 0.42 MB
8103_Credit.pdf
Additional Documents • 0.32 MB
8103_Drgs.pdf
Additional Documents • 19.10 MB
8103NIT.pdf
Additional Documents • 4.27 MB
Download all tender documents and submit your bid