Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.9 LAccepted-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | ₹12.9 L Quoted ₹14.4 L | L1 | Accepted-AOC Lowest Quoted |
| 2 | L2₹16.3 L+₹1.9 L (13.1%)Rejected-Finance | ₹16.3 L+₹1.9 L (13.1%) | L2 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 3 | L3₹18.7 L+₹4.3 L (29.5%)Rejected-Finance NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹18.7 L+₹4.3 L (29.5%) | L3 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 4 | L4₹19.4 L+₹5.0 L (34.6%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹19.4 L+₹5.0 L (34.6%) | L4 | Rejected-Finance OTHER THAN LOWEST QUOTED |
| 5 | L5₹22.6 L+₹8.1 L (56.3%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹22.6 L+₹8.1 L (56.3%) | L5 | Rejected-Finance OTHER THAN LOWEST QUOTED |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
29 Sept 2020, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
REPAIR TO EXHAUST FAN, GYSER, CEILING FAN AT UPPER AND LOWER CAMP AT AF STN UDHAMPUR
2020_MES_369401_3
GE/AFU-30/2020-21
Open Tender
Miscellaneous Works
Item Rate
334 days
AF STATION UDHAMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹60,000
Yes
5 Nov 2020
15 Sept 2020
1 Oct 2020
15 Sept 2020
29 Sept 2020
15 Sept 2020
Amount
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete with fittings such as switches, tube lights, ceiling rose, pendants, regulators, MCB DB, MCBs, Main switches from control board and making good disturbed surfaces of walls, floor to match with existing specifications complete all as specified.
Point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 6 Amps socket outlet independent controlled by one switch with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Point wiring for one 16 Amps socket outlet independent with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through & including PVC, rigid concealed conduit, heavy duty, 19/20mm dia, ISI marked, with and including new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 2.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. Note :-Switches, sockets, outlets & regulators will be measured and paid for separetely.
Description all as per serial item No.2 here-in-before but in existing concealed conduit.
Description all as per serial item No.3 here-in-before but in existing concealed conduit.
Description all as per serial item No.4 here-in-before but in existing concealed conduit.
Switch modular type 6 AMP,one way , one module conforming to IS-3854 complete all as speciifed and as directed
Switch modular type, 16/20 Amp, one way, one module conforming to IS-3854 complete all as specified and as directed.
Socket shuttered outlet 2/3 pin, 6 Amp modular type, 2 modules complete all as specified and as directed.
Socket shuttered outlet 2-in-1, 6/16 Amp modular type, 2 modules complete all as specified and as directed.
Modular type blanking plate, 1 module, complete all as specified and directed .
Ceiling rose, surface bakelite 65 x 50mm, two to three terminals complete all as specified and as directed.
Modular electronic fan regulator 2 modules rotary step type 230 volts complete all as specified and as directed.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 4.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire, including suitable size of PVC conduit drawn through PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 6.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 6.00 sqmm main cable and one RM of 4.00 sqmm cable earth wire together shall be considered as 1 running metre for payment purpose.
Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire, drawn through existing PVC surface/concealed conduit and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of one RM of 6.00 sqmm main cable and one RM of 6.00 sqmm cable earth wire together shall be considered as 1 running metre for payment purpose.
MCB distribution board having IP-54 protection, powder coated, double door, flush mounted complete with locking arrangement suitable for 8 way SPN with 200 Amp rated bus bar 230 volt AC supply including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make:CAT PART NO:507682 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
Sheet metal enclosures for DBs SPN 2 way (when MCBs to be used) flush mounted including taking down existing unserviceable DBs /board /box including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / Schneider
MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic including taking down existing old unservicable including accessories therein & disposing from site complete all as specified and as directed. Make:CAT PART NO:408618 of Legrand or equavalent to HAVELLS / SIEMENS/Schneider
Taking down the complete ceiling fan/exhaust fan/wall fan of any type/size from different locations for repairs and fixing back after repairs at proper locations complete all as specified and directed. (Repairs & spares shall be measured and paid separately under respective item of BOQ) Note : All repairs/servicing/rewinding work shall be carried out in MES store yard.
Cutting of all copper coils & taking out burnt/damaged wire from ceiling fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating material, soldering, varnishing, assembling and testing complete all as specified of the following sweep:-
(a) 1200 mm sweep
(b) 1400 mm sweep
Standard ball bearing of ceiling fans of 1200/1400 mm sweep size suitable for different makes of fans of approved quality including necessary greasing of the following:-
(a) For 1200 mm ceiling Fans. Make : NBC/SKF/NORE
(b) For 1400 mm ceiling Fans. Make : NBC/SKF/NORE
S&F in repairs bush gun metal suitable for ceiling fans 1200/1400 mm sweep/exhaust fan 300 to 400 mm sweep, cabin fan of any make any size complete all as directed at site.
S&F in replacement of old unserviceable armature shaft for ceiling fans of 1200/1400 mm sweep of any make complete all as specified.
S&F in repairs down rod 30 cms long made out of heavy grade M.S pipe with necessary threading at both ends, holes as required matching with existing & painting for size of ceiling fan 1200mm/1400 mm as all directed by Engineer-in-Charge. Make :- Orient/Usha/Khaitan or as directed by GE.
S&F in repairs down rod 60 cms long made out of heavy grade M.S pipe with necessary threading at both ends, holes as required matching with existing & painting for size of ceiling fan 1200mm/1400 mm as all directed by Engineer-in-Charge. Make :- Orient/Usha/Khaitan or as directed by GE.
S&F in repairs rubber bushes and real synthetic rubber with 14.5 mm hole suitable for fan hooks for hanging of ceiling fans all directed by Engineer-in-Charge.
S&F in replacement nuts, bolts & washers with clamp with complete set of appropriate size for hanging of ceiling fan all directed by Engineer-in-Charge.
S&F in replacement blade made out of aluminium suitable for any make and sweep size with existing colour, set of three for one ceiling fan as directed at site by Engineer-in-Charge.
S&F in replacement upper & lower canopy made of good quality PVC of required size complete set for ceiling fan with tightening screws all directed by Engineer-in-Charge.
S&F in replacement condenser/capacitor suitable for 230 volts single phase for ceiling fan/exhaust fan/cabin fan/pedestal fan of capacity 2.5 mfd including necessary connection complete all as specified.
S&F in replacement condenser/capacitor suitable for 230 volts single phase for ceiling fan/exhaust fan/cabin fan/pedestal fan of capacity 3.15 mfd including necessary connection complete all as specified.
S&F in replacement condenser/capacitor suitable for 230 volts single phase for ceiling fan/exhaust fan/cabin fan/pedestal fan of capacity 4 mfd including necessary connection complete all as specified.
S&F in replacement for providing three core 23/.0076 with copper conductor ceiling fan to ceiling rose and making connection complete all as specified and directed by Engineer-in-Charge.
Painting one coat of synthetic enameled paint by spraying to ceiling fans of any type in MES store yard including preparation to old painted surfaces by filling cavities etc and overhauling by providing correct grade of lubricant oil/wheel bearing grease complete including making/writing of MES No all as directed by Engineer-in-charge. Note: Painting of fans shall be carried out in MES stores Yard.
S&F in replacement exhaust fan frame cover made out of M.S sheet of any make and size as per existing exhaust fan with suitable size of nuts, bolts & washers complete all as specified and directed by Engineer-in-Charge.
Cutting of all copper coils & taking out burnt/damaged wire from exhaust fan motor of any make and M&L for rewinding of exhaust fans of 450 mm sweep with super enameled copper winding wire of same size, gauge & weight including varnishing & insulating complete all as specified and directed.
Description all as per Srl item No. 43 here-in-before but 380/350mm sweep.
Description all as per Srl item No. 43 here-in-before but PVC fresh air fan.
S&F in replacement of super quality louver shutters made out of aluminium for 450mm sweep exhaust fan of any make all as specified & directed.
Description all as per Srl item No.46 here-in-before but for 300/380mm sweep exhaust fan.
S&F in replacement ceiling fan regulator heavy duty electronic rotary step type 230 volts 50 Hz AC complete all as specified and directed by Engineer-in-Charge. Make :- Usha, Bajaj, Crompton, Kessels, Khaitan.
Fan hook split type fabricated out of 12mm dia steel bar of length 30cm duly painted with black coloured synthetic enamel paint (two coats) over a coat of red oxide primer including taking down old unserviceable, all as specified. Note:- Credit schedule has been given separately under tender documents and shall be adjusted in general summary by the deptt. for arriving at net contract sum.
S&F PVC Exhaust fan of size 200 mm sweep ,240 V including grouting in wall with hold fastner ,wooden frame as required at site,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.MAKE:HAVELLS/BAJAJ/CROMPTON
S&F PVC Exhaust fan of size 250 mm sweep ,240 V including grouting in wall with hold fastner ,wooden frame as required at site,including taking down old unserviceable,complete all as specified and directed by Engr-in-charge.MAKE:HAVELLS/BAJAJ/CROMPTON
S&F in replacement LED retrofit lamp with maximum wattage 7 watt (lumen output not less than 700 lumens) with B 22 holder base with thermal conductive engineering plastic white colour housing and aluninium heat sink with specially designed fins clear/cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation long life burning hours 50000 hours complete all as specified.(including taking down of existing serviceable /unserviceable lamps and disposing off as directed by Engineer-in-Charge). MAKE :CAT Part No:N70001 of wipro or equavalent to Havells/Philips/Crompton Note :The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved.
Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall and re-installation at any location including S&F in repairs of heavy duty pin type fastener 4” long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed.
S&F in repairs heating element, cup (round) type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, thread type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA / Bajaj / Recold.
S&F in repairs heating element, tikona type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, tikona banana type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, cup (round) type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, thread type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, tikona type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs heating element, tikona banana type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
S&F in repairs thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj / Recold / Theta / Elcon.
S&F in repairs inner copper tank of 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers complete all as specified and as directed. Note : Weight of inner copper tank of geyser shall not be less than 3.75 Kg.
S&F in repairs stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (weight not less than 3.75 kg) as per sample complete all as specified and as directed.
S&F in repairs inner copper tank of 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 50 ltrs capacity geysers complete all as specified and as directed. Note : Weight of inner copper tank of geyser shall not be less than 5.25 Kg.
S&F in repairs of stainless-steel inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 50 ltrs capacity geysers (weight not less than 5.25 kg) as per sample complete all as specified and as directed.
Supply and replacement of glass wool for geysers complete all as specified and as directed.
S&F in repairs base 09 Nuts assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
S&F in repairs base 06 Nuts assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
S&F in repairs indicator lamp for geyser of any type colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
S&F in repairs outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enameled paint complete all as specified and as directed.
S&F in repairs outer body of MS sheet not less than 20 gauge suitable for 50 ltr geyser with white synthetic enameled paint complete all as specified and as directed.
S&F in repairs plug top 3 pin 15 Amp ISI marked complete all as specified and as directed. Make : SSK/CONA/FINE.
S&F in repairs bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in repairs bottom cover of MS sheet 20 gauge suitable for 50 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in repairs brass non-return valve 15 mm bore ISI marked screwed both ends and connecting to iron pipe in repairs complete all as specified and as directed. Make : Neta metal works/Orient/Leader/Bir.
S&F in repairs brass stop cock (of weight not less than 400 g), chromium plated, suitable for 15 mm bore iron pipe, ISI marked, screwed down high pressure with crutch handle, screwed both ends complete all as specified and as directed. Make : PARKO/SEIKO/GEM
S&F in repairs PVC connection 450 mm long heavy duty with brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed. Make : Y King/Recold/Prayag.
S&F in repairs 3 core PVC insulated copper cable of size 40/0.0076 multi stranded complete all as specified and as directed.
S&F in repairs safety plug confirming to relevant IS with washer suitable for 15 mm GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Theta / Usha.
S&F in repairs of pressure relieving valve, confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Leader/ Theta or ISI marked.
GI tubing medium grade of size 25mm bore ISI marked galvanized with all fittings such as bends, elbows, tees, check nuts, unions nipples etc for cold water pipe line complete all as specified and as directed including taking down old.
Description all as per item No 82 here-in-before but 20mm bore.
Description all as per item No 82 here-in-before but 15mm bore.
Painting of outer surface of 25/50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
S&F in repairs brass bib cock CP 15 mm bore heavy duty confirming to relevant IS (weight not less than 400 g) complete all as specified and as directed. Make : PARKO/SEIKO/GEM
S&F in replacement garden lights refer to the use of outdoor illumination for garden and public landscpaes for diffused lighting with high power LED as light sourece including excavation and fixing arrangement with 40mm dia and minimum 1.2mtr long MS black pipe and prewired of suitable size as directed by Engr-in-Charge. Make : Cat Part No BAMBOOBL8WLED757PSYMTOPC of Havells or equvalent to bajaj/philips/C&S
Supply, laying , jointing , commissioning and testing cable (armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 6 sqmm ,2 core laid on walls/floors or in air with saddles and gutties, complete all as specified and directed by Engr-in-Charge
Supply, laying , jointing , commissioning and testing cable (armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 10 sqmm ,2 core laid on walls/floors or in air with saddles and gutties, complete all as specified and directed by Engr-in-Charge
Supply, laying , jointing , commissioning and testing cable (armoured) XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with stranded aluminium conductors, 1100 volts grade of size 16 sqmm ,2 core laid on walls/floors or in air with saddles and gutties, complete all as specified and directed by Engr-in-Charge
KARAN TRADERS
MAHAJAN TRADING CO
DAVINDER SINGH
R K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .