Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L1 | Accepted-AOC Being Lowest bidder | |
| 2 | L2₹12.5 L+₹1,985 (0.16%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.9 L+₹36,550 (2.92%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹12.9 L+₹41,660 (3.33%)Rejected-Finance 544 STREET NO 10 GHUMMAN NAGAR PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹13.2 L+₹70,055 (5.60%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
24 Jun 2020, 6:00 pmClosed
GE (South) Patiala
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender document
2020_MES_348504_1
GE(S)/PAT-09/N/2020-21
Open Tender
Civil Works
Item Rate
150 days
Mil Stn Nabha
Refer tender document
6 documents required · 6 mandatory
₹500
Yes
GE (South) Patiala
₹29,000
Yes
17 Jul 2020
30 May 2020
26 Jun 2020
30 May 2020
24 Jun 2020
8 Jun 2020
30 May 2020 - 6 Jun 2020
Amount
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed.
M & L for 15mm thick ( in two layers of 10mm and 5mm thickness) cement pastering in cement mortar 1:4 and mixig the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished fair and even without using extra cement complete all as specified and directed Note : Water proofing compound shall be measured and paid saparately under item No 3 .
Supply only integral water proofing compound ISI marked.
Rendering 5mm thick in cement mortar 1:3 as on concrete surfaces in ceiling finished even and smooth without using extra cement all as specified.
Preparation of new plastered or unplastered surfaces applying three coat of white wash on ceiling surfaces all as specified.
Preparation of old painted steel or iron based surfaces, of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint in complete all as specified and as directed.
Preparation of old painted wooden or wood based surfaces, of any description, not otherwise described, over 10 cm width or girth incl knobbing and stopping as required and applying one coat of synthetic enamel paint in complete all as specified and as directed.
Preparing old plastered surfaces of ceilings and applying one coat of white wash in all as specified and as directed by Engineer- in- charge.
Complete removal of existing treatment of any type/description such as cement base paint, external emulsion etc from external surfaces of walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc with mechanical means/grinder including removal of waste material from site complete all as specified and directed.
Applying acrylic wall care putty in external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed by Engr-in-Charge. Notes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order.
Applying 02 coats of exterior emulsion paint (light shade) as per manufacturer instructions by using roller to external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc surfaces over & including a coat of exterior wall primer as recommended for under coat by manufacturer of exterior emulsion, complete all as specified and directed.
Complete removal of existing treatment of any type/description such as distempering work, internal emulsion etc from internal surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed.
Applying acrylic thick wall care putty on internal surfaces of walls/ceilings (thickness vary from 1.5 to 2.5 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior painting complete all as specified and directed. Notes : (i) The prepared surface after wall putty, the contractor will inform to the Engineer-in-Charge for site inspection before applying further external finishes. Please note that the further external finishes work will start only after approval of the prepared surface from the Engineer-in-Charge through site order.
Applying 02 coats of interior emulsion paint (light shade) as per manufacturer intructions by using roller to wall surfaces over & including a coat of interior wall primer as recommended for under coat by manufacturer of interior emulsion by using following brands of emulsion and primer complete all as specified and directed.
Dismantling of floor or wall tiling including cement mortar bedding but not backing and removing the rubbish off the premises complete all as specified and directed.
M&L for Vitrified ceramic floor tiles of minimum size 600 x 600 mm x10mm thick in flooring etc set and jointed in neat cement lurry and pointed in white cement to match over and including 20mm thick screed bed in CM (1:4) laid in complete all as specified and directed.
M&L for 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates for base of flooring in complete all as specified and directed.
Coloured glazed ceramic tiles (300 x 600 mm) x 7mm thick as in vertical surfaces such as skirtings, dados etc jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick back coat in CM (1:4), in complete all as specified and directed.
Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified
S & F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws complete all as specified and directed.
Dismantling of unserviceable wrought iron or mild steel of any description not other wise provided for complete all as directed .
M&L for rolled sections as in main and cross beams, hip and jack rafters purlins, where connected to common rafters and running rails and guides for structural purpose, fixed with angle cleats or other connecting plates to Fe-290 (Gde E-165), complete all as specified and directed.
M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quions, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete.
M&L for brick work in cement mortar (1:4) using sub class 'B' bricks staight or curved on plan exc 6.0 m mean raidus
Taking down Chowkats or frame exc 1.5 Sqm and not exc. 4Sqm each with shutters (without taking off shutters from the frames) all as specified.
All as per srl item No 28 hereinbefore but n. exc 1.5 sqm each.
S&F 150mm long alum anodised barrel tower bolts of extended action.
S&F 50 micron reflective type sun control film sticked to glass panes as per manufacturer's instructions all as specified and as directed.
S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates Powder coated to them (minimum thickness of powder coating 50 microns) bates including joining cleat for fixing glazing/particle board etc. complete all as specified.
S&F Powder coated (minimum 50 microns) aluminium door shutters, aluminium sections weighing 0.55 kg/M including joining cleats,glazing clips,ruber neoprene packing handles 2 Nos in each door, hinges, anodised etc complete all as specified
S&F 5.5 mm thick sheet glass ordinary quality, glazing and rubber beading with oil putty fixed in aluminium windows/door/partions and all as specified
S & F only mortice lock of size 150mm long 6 levers, complete all as specified.
Door closer Aluminium Die cast hydraulically regulated designation No 3, universal type, suitable type for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixedNo 3 universal type, suitable for door shutters up to 700mm in width and of weight not more than 35 kg and fixed all as specified.
Demolition of reinforced cement concrete of any description in any position including cutting reinforcement to facilitate demolition, complete all as specified and directed.
M&L for Reinforcement cement concrete (Nominal mix) 1:2:4 Type B1 (20 mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
TMT bars 6 to 8mm dia and over mild steel as in reinforcement, cut to length bent to shape required including cranking and bending with MS wire (anealed) not less than 0.9mm dia or securing with clips all as specified and directed.
Taking out old damaged tar felt of any description from roof tops including cleaning and washing the surface before applying roof treatment.
PCC 1:3:6, type C-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 25mm to maintain a slope of 1:100 complete all as specified and directed.
Providing and laying 3mm thick APP (Atactic Polyproplene Polymer) modified prefabricated five layer, weight not less than 4 Kg/Sqm water proofing membrane, black finished, reinforced with non-woven polyster matt make as approved, consisting of a coat of bitumen primer @ 0.40 Ltr/sqm by the same membrane manufacturer, of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70 - 160 cps. Over the coat , the layer membrane shall be laid using butane torch and sealling all joints etc after the surface complete as per standard practice as per manufacturer's instructions. The vital physical and chemical parameters of the membrane shall be as under:- (i) Joint strength in longitudinal and transverse direction at 23 degree C as 650 / 450N/5cms. (ii)Tear strength in longitudinal and transverse direction as 300 / 250 N / 5cms. Softening point of membrane not less than 150 degree C. Cold flexiblity upto 20 degree C when tested in accordance with ASTM (D-5147). (iii) The laying of membrane shall be got done through the authorized applicator of manufacturer of membrane only.
Applying one coat of aluminium paint over APP membrane @ 0.50 litres per Sqm all as specified and directed.
S&F 20 mm bore ,1 mm wall thickness MS plastic coated condute including MS (plastic coated) and PVC side cups(nickel coated) as in curtain rods incl. brackets, fixed in repairs, complete all as specified.
S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs washers and wastes icluding bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915mm x 460mm bowl size 410mm x 330mm x 160mm fixed in repairs, complete all as specified and directed.
M & L 20mm thick marble machine cut as laid over cement screed 15mm thick in CM 1:4 over and jointed with gray cement slurry mixed with pigment including rubbing and polishing complete all as specified and directed.
Built in steel cup board shutter made out pressed steel frame of size 75mmx45mmx1.25mm thick with prressed steel shutter 01mm thick Godrej pattern fixed to masonry wall by hold fasts made out of 25x3mm flat iron including mild steel CP hanging rod of 20mm dia with brackets fixed on inner sie of one leaf of shutter and on other leaf provision of mild steel CP peg set of 3 including spray painting with two coats of synthetic enemal paint over one coat of red oxide primer all around on steel surfaces of frame and shutter including taking down existing wooden cup board and making good disturbed portion in CM 1:3 or PCC 1:2:4 all as specified and directed and shown on Drg No 178 sheet 2/3 and 3/3 dt 21.06.2001.in and 1.25 mm thick in frame work, cut to size, holes punched, welding, riveting, turning, bending etc. as require to made it in Godrej pattern complete all as specified and as directed.
Hard core of broken bricks of gauge n exc. 63 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface all as directed and specified
PCC (1:3:6), 50mm thick as in PCC path/ plinth protection, finished the surfaces even and smooth with out using extra cement
M & L Machine cut kota stone slab flooring 20 (+ 2) mm thick size of slab 58cm x 58cm laid over cement screed 20 mm thick in CM 1:4 laid over and including 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates and jointed with gray cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
Kota stone slab 20 (+ 2) mm thick in riser of steps,skirting or in dado as in verticle surface, as required at site all as specified and directed
M&L in repair for anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and "T' sectiopns of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 12 mm thick perforated particle board/tiles for insulation and accoustic purposes, 60x60 cm size fixed with staples on snap grid complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light fan socket or power) complete along with fittings such as switches, ceiling roses, Pendants regulators Tube fittings and other Kits & fittings/conduit from surface /wall . Removing the material from work site and making good the disturbed portion/ surface of wall/ floor/ ceiling etc by using cement mortar and colour/ white wash to match with the existing surface / location. (Note ;- Serviceable fitting / fixtures will be reused in the work as directed by Engineer- in-Charge)
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point includig cutting chasing and making good with CM 1:3 where required, complete all as specified and directed. in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
All as per item No 54 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 54 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 54 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
M&L for Modular switch 1 way 6A, 1 module type all as specified and directed.
M&L for Modular switch 1 way 16A, 1 module type all as specified and directed.
Supply & Fix modular type, socket 5 pin 6 Amps, 2 modue complete all as specified.
Supply & Fix modular socket 5 pin 6/16 Amps, combination type 2 moduel complete all as specified.
Supply & fix in replacement of existing unserviceable FTL with new techonlgy self blasted LED retrofit tube lamp with thermoplastic body with high lumen 18 w 6500 K suited for installation in existing t5 tubelight including neccessary electric conection with box type batten, complete all as specified and directed.
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 18 watts for batten fitting, complete all as specified.
Supply and fix LED Lamp LED new Adore 9W E27 W Ball Lamp 9 watt, complete all as specified and direcetd
Material and labour for call bell ding dong AC 230 volt single pole complete all as specified.
Material and labour for Modular Bell push 6A 1 module complete all as specified.
Supply and replace environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit led luminaire comprising of high brightness leds of capacity10 Watt, complete all as specified.
M&L for replacement of existing earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
M & L for Fan step regulator, 120W - 1 module
S&F in replacement sheet metal enclosures distribution boards,vertical type double door three phase 415 volts 4 ways (one incoming three phase & four out goings three phase )for MCCB,ISOLATOR&MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a)MCCB FOUR POLE 100 AMPS AC 415 VOLTS 16 KA IHLGNF0063 =01 NO as incoming Note :- (i) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost. (ii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. (iii) All the vacant holes of the DB shall be provided with blank plates of appropriate size.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The DB shall be fiush fixed and making good the disturbed surface shall be part of job at no extra cost.
Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Taking down ceiling fan of any type of any size cleaning, dusting, oiling and greasing complete and fixing the same ceiling fan as directed by the Engr -in- Charge including replacement of three core flexible PVC conductor cable of Size 23/0.0076/ ceiling fan to ceiling rose/commector, complete all as specified and directed.
Supply & fix exhaust fans AC single phase 230/ 240 V of size 450 mm sweep with louver, complete all as specified and directed. Note: Fixing of Exhaust Fan on wall with suitable size anchor bolt , making hole in wall for groutng and making good the disturbed surface including plaster work shall be part of job at no extra cost.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of crosssectional area 25 Sqmm 3 & 1/2 Core all as specified & directed by Engr-in-Charge.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming completed all as specified and directed.
Supply and laying well burnt sub class ‘B’ bricks. ( designated 75) locally available best quality laid dry in trenches for protection of underground cable all as specified and directed.
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.
Jagdish kumar aggarwal
m/s panchmukhi builders
FAVOURITE ENGINEERS
M/s Pawan Kumar Goyal
m/s k.k. construction co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .