Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L1 | Accepted-AOC Accepted being lowest bidder | |
| 2 | L2₹11.9 L+₹74,617.55 (6.67%)Rejected-Finance 3RD FLOOR BHAKTAMAR RESIDENCY SOMNATHNAGAR ROAD PUNE 411014 | PUNE | PUNE | MAHARASHTRA | 411014 | L2 | Rejected-Finance Rejected being not lowest bidder | |
| 3 | L3₹12.4 L+₹1.2 L (10.6%)Rejected-Finance | L3 | Rejected-Finance Rejected being not lowest bidder | |
| 4 | L4₹12.4 L+₹1.3 L (11.2%)Rejected-Finance | L4 | Rejected-Finance Rejected being not lowest bidder | |
| 5 | L5₹13.9 L+₹2.7 L (23.9%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | L5 | Rejected-Finance Rejected being not lowest bidder |
Tender Value
₹20.4 L
EMD Value
₹40,838
Closing Date
15 Sept 2020, 6:00 pmClosed
Headquarters CWE Kirkee, Military Engineer Service
Headquarters CWE Kirkee, Military Engineer Services, Range Hills Road, Kirkee, Pune-411003
Special Repair to LT UG Cables at BDTC and Ashok Nagar area Range Hills under GE MH AND RH Kirkee
2020_MES_370570_1
CWE/KKE/ TOKEN-27 OF 2020-21
Open Tender
Civil Works
Works
150 days
Kirkeee
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE MH AND RH KIRKEE
₹40,838
Yes
23 Oct 2020
19 Aug 2020
17 Sept 2020
19 Aug 2020
15 Sept 2020
10 Sept 2020
20 Aug 2020 - 27 Aug 2020
Amount
Supply,laying, testing and commissionnig of UG LT cables for fixing or passing through DWC pipe, laid in trenches or fixed to pole/wall or fixed to LT panel and board, XLPE insulated and PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor conforming to IS - 1554 part-I 1100 volts grade, corss sectional area of size 240 Sqmm 3.5 core with required suitable size aluminum cable lugs (lugs should properly crimmped with crimpping tools) heat shrink joints, colour code heat shrink sheeves at both cable ends, cable gland for cable safety when passing through panel holes, including laying cable route indicators made out of MS angle iron of size 25 x 25 x 3 mm thick 60 cm long LT cable route indicatator making embossed on CI circular plate 150 mm dia 3 mm thick including groutting in PCC 1:3:6 type C 1 block concrete of size 20 x 20 x 20 cm including necessary earth work and painting over a coat of red oxide primer complete all as specified and directed as per site requirement all as specified and directed by Engr-in-Charge. Note: (i) DWC pipe required shall be measured and paid separately under relevent item of schedule as supply only. (ii) Heat shrink sleeve sleeve, lugs, cable glands, cable route indicators all are deemed to be included on the quoted rate. (iii) Earth work such as Excavation, Returning filliing, Removal measured and paid under separte items.
Ditto all as per item no. 1.00 above but for size of cable 120 Sqmm 3.5 core
Ditto all as per item no. 1.00 above but for size of cable 50 Sqmm 3.5 core
Ditto all as per item no. 1.00 above but for size of cable 70 Sqmm 3.5 core
Supply and laying of Telerex DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia 50 mm and inner dia 38 mm polythylene including coupler and bend with smoth internal and profiled external surface for non pressure under ground cable complete all as specified and directed. Make: Rex Polyextrysion Ltd or equivalent make as approved by GE.
Ditto all as per item no. 2.00 above but for size of pipe 80mm dia
Taking down unserviceable LT panel and Supply, install, commissioning and testing of LT outdoor type feedar pillar box 415 V/440 Volts, confirming to IEC 61439 with IP-54 protection of suitable size made out of 3.15 mm thick CRCA sheet with both side openable door with locking arrangement and complete panel should be powder coated with having neoprene rubber gasket for sealing door, doors of the panel should be removable type, including 630 A current capacity Aluminium bus bar for 3 Nos phase, 1 No of neutral of suitable size horizontal and vertical mouniting on suitable capacity of insulators, Multifunction meters with suitable size of Current Transformers copper wounded, resin cast, indicators lamp etc with provision for 11 Nos of 4 Pole MCCBs 01 No Incoming & 10 Nos outgoing with Analog street light timer , copper panel control wiring as per IS direction,make internal compartment for mounting MCCBs/MCbs and bus bars using 2 mm thick CRCA sheet, the panel shall be mounting on 50 x 50 x 6 mm MS angle iron and 60 cm above the normal ground level & embedded 20 cm below ground level in PCC foundation (1:2:4) type B 1, connect new UG cable for Incoming from Transformer to panel and out going ten nos thorugh MCCB cable shall enter through cable glands for safety of cable where enter through panel complete all as specified and directed by Engr-in-charge. Note: (i)Multifunction meter Make L & T Cat No: WC4420510000. (ii) Current Transformer should be caliberated and tested on MSEDL certificate should produce by contractor. (iii) Panel should be CPRI certified.
Dismantlling existing MCCB of various capacity and refixing the MCCBs on panel complete all as specified and directed.
M&L for earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm burried directly in ground earth pit not less than 3.25 mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 mtr below ground level connected to and including GI strip of size 32 x 6 mm 7.5 mtr beyond the earth pit as earthing lead including GI protection pipe 40 mm bore (light grade) upto 7.5 mtr beyond the earth pit and connecting to equipments by means of earthing lead , GI bolts, nuts & washer etc with provision of char-coal and salt etc all as per electrical plate No 3 of SSR Part - I, 2009 including RCC cover and MS angle iron frame watering arrangements with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork of any strata and testing on completion etc complete all as specified and directed by Engr-in-charge. Note : Rate of item is deemed to be included for excavation in hard rock, by compressor machine to achieve required depth.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 mtr depth n exc 10 sqm on plan for laying of UG cable / pole/ Stays etc getting out including forming bottom surface to required level and gradientt in soft/loose soil complete all as specified and as directed.
Excavation in trenches n. exc 1.5 m wide and n. exc 1.5 mtr depth n exc 10 sqm on plan for laying of UG cable / pole/ Stays etc getting out including forming bottom surface to required level and gradientt in hard rock by mechanical plant or chisel cutting complete all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc. 25cm in soils complete all as specified and as directed.
Removing excavated material( soil) to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and as directed.
M&L for moorum/red bajri filling in floors or pavings laid in layers n exc. 15 cm thick, spread, levelled and rammed, including watering complete all as specified and directed.
Adinath Technical Services
MORESHWAR ELECTRICALS CORPORATION
MANGAL ELECTRICAL STORES
metro electrical services
Prasur Electricals & Engineering Co.
M/S. Niksun Electro-Infra Private Limited
SKS Electricals
JP ENTERPRISES
M/s IBEX Engineers and Contractors
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .