Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹41.9 LAccepted-AOC 002 1 NATHAKADU SRI MAHALAKSHMI DYEING PRINTING MILLS CAMPUS BHAVANI MAIN ROAD ERODE 638004 | ERODE | ERODE | TAMIL NADU | 638004 | 1 | Accepted-AOC 1 | |
| 2 | 2₹46.1 L+₹4.2 L (10.0%)Rejected-Finance 1 102 UNION OFFICE ROAD VEPPUR POST KUNNAM TALUK PERAMBALUR 621 717 | PERAMBALUR | PERAMBALUR | TAMIL NADU | 621717 | 2 | Rejected-Finance 2 | |
| 3 | 3₹47.5 L+₹5.6 L (13.5%)Rejected-Finance | 3 | Rejected-Finance 3 | |
| 4 | Rejected-Technical 1 338 BX 1ST STREET UTHUKULI ROAD GOLDEN NAGAR CHENGAPPALLI TIRUPPUR 638 812 | TIRUPPUR | TIRUPPUR | TAMIL NADU | 638812 | - | Rejected-Technical BQR Not Satisfied | |
| 5 | Rejected-Technical 57 KAMARAJ STREET KOLAPPALUR GOBICHETTIPALAYAM ERODE 638 456 | GOBICHETTIPALAYAM | ERODE | TAMIL NADU | 638456 | - | Rejected-Technical BQR Not Satisfied |
Tender Value
₹49.9 L
EMD Value
₹49,900
Closing Date
8 Oct 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Superintending Engineer / Triupur EDC
OFFICE OF THE SUPERINTENDING ENGINEER, TIRUPUR ELECTRICITY DISTRIBUTION CIRCLE/ CIVIL SECTION, 208 650, KRBS TOWERS, 3RD FLOOR, PERUMANALLUR ROAD, TIRUPUR 02
CONSTRUCTION OF NEW CONTROL ROOM BUILDING WITH CABLE DUCT ARRANGEMENT FOR THE EXISTING TPR SS
2024_EB_487388_1
Specn.No. 02/24-25 Dt.23.09.2024
Open Tender
Civil Works - Buildings
Works
120 days
Tirupur SS
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹49,900
Yes
18 Feb 2025
23 Sept 2024
9 Oct 2024
23 Sept 2024
8 Oct 2024
24 Sept 2024
24 Sept 2024 - 8 Oct 2024
Clearing scrub jungles with uprooting and disposed from the site as per the direction of site engineer including labour, lead, lift, etc., complete
Earth work excavation and depositing on bank with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders including labour, lead, lift, etc., complete as per standard specification
Earth work excavation and depositing on bank with initial lead of 10m and Initial lift of 2m in Soft Disintegrated rock, laterite, soft rock or kankar, not requiring blastng including labour, lead, lift, etc., complete as per standard specification
Earth work excavation and depositing on bank with initial lead of 10m and initial lift of 2m in medium rock and dense medium rock, not requiring blastng including labour, lead, lift, etc., complete as per standard specification
Removing hard rock by wedging , chiselling and trimming to proper shape where blasting is prohitibed.
Providing anti termite treatment in 4 stages I) immediate after earth work excavation and before laying foundation concrete II) after refilling for sides of foundation III) Before laying of flooring concrete IV) outside of basement upto 1.0m alround the building including cost of all materials labour, lead, lift, etc., complete as per standard specification as directed by the site incharge .
Supplying and filling with M. sand for foundation including cost of all materials, well consolidation, labour, lead,lift, etc. complete.
PCC 1:3:6, using 20mm HBG metal for foundation including cost of cement, all materials, labour, curing, lead, lift, etc. complete.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for stair case landing slab mid landing and top landing slab including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for raft foundation including cost of all materials, centering, curing, labour, lead, lift, etc. complete. but excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for columns including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement - Upto Ground Level.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for columns including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement - Ground floor (ground level to roof level )
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for columns including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement - First floor
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for Grade and Plinth beam including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for lintel beam including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for sill beam including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for Sunshade and Loft including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement. [For 60cm projection - 100 mm tk at wall and 75mm tk at free end anf For 100cm projection - 150 mm tk at wall and 100 mm tk at free end].
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for Roof Beam including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm hard machine broken granite stone for Roof slab of 125mm Tk including cost of all materials, form work, centering, curing,labour charge, lead, lift, etc. complete. But excluding cost of steel reinforcement.
RCC 1:1.5:3 using 12-20mm graded hard machine broken granite stone for precast cover slab including cost of all materials, form work, centering, curing, labour, lead, lift, etc. complete. But excluding cost of steel reinforcement.
Labour charges for transporting of RCC pre cast slab from casting yard to curing tank, curing tank to cable duct position, aligning and laying of RCC pre cast slab as directed by the site engineer including all labour, lead, lifts, etc complete.
Brick work in CM 1:5 using II class champer burnt bricks for walls including cost of all materials, curing,labour, lead, lift, etc. complete.
Brick work in CM 1:3 using II class champer burnt bricks for basement and steps etc., including cost of all materials, curing, labour , lead, lift, etc. complete.
Supplying and fixing of suitable GI angles horizontally @ 50cm c/c to the required length for supporting the cable in the cable duct in correct position including fabrication, labour for fixing in correct position,cutting etc., complete as per the drawing with standard specification.
Refilling with excavated earth other than sand in foundation with well consolidation,watering ncluding all, labour, lead , lift, etc., complete.
Providing steel reinforcement with MS/RTS rods of reputed approved make for reinforced concrete works, including cost of steel MS/RTS rods, binding wire, Minor T & Ps labour charges for cutting, straightening bending as per type design drawing, placing aligning, and tying properly with all leads and lift etc., complete as per Standard Specification
Plastering with CM 1:5, 12mm thick including cost of all materials, labour, curing, lead, lift, etc. complete.
Plastering with CM 1:3, 12mm thick for ceiling, beams, sunshade including cost of cement, all materials,curing, labour, lead, lift, etc., complete.
Flooring with PCC 1:2:4 using 12- 20 mm HBS metal of 100 mm thich with plastering in CM 1:3 12mm thick for cable duct and plinth protection including cost of all materials lead, lift, labour, etc, complete.
Providing PCC 1:2:4 mix using 6 mm and 10 mm HBG metal of a average thickness of 0.075 m with water proofing compound and finishing the top with solar reflective tiles including cost of all materials,pointing, labour, curing, finishing with proper slope, lead,lift, etc., complete as per the direction of site incharge.
Providing 110mm dia PVC down fall pipe of 4 Kg / sq cm. including cost of pipe, door bend, shoe and clamp, labour for fixing in position from the roof top, lead, lift, etc., complete.
Providing two coats of wall putty of approved quality over the plastered surface including removal of all loosly adhering materials from the wall surface with the help of emery stone,putty blade or wire brush and making the surface in just wet condition as per the specification and approved by the site engineer including cost of all materials, labour, lead etc complete.
Painting two coats with interior emulsion of approved quality and colour over a priming coat for inside wall surfaces including cost of all materials, labour, lead, lift, T&P, etc. complete.
Colour washing two coats with exterior emulsion of approved quality and colour over a priming coat with one coat white washing for outer wall surface including cost of all materials necessary plaster of paris, putty, wherever required,labour, lead, lift, etc., complete.
Painting two coats of Acid Proof Paint of approved quality & colour over one coat of priming coat including cost of all materials, labour, lead, lift etc., complete.
Supplying and filling of red gravel for basement filling with well cosolidation,watering including cost of all materials labour, lead, lift etc complete as per the direction of site engineer.
Dadooing wall with glazed tiles of approved colour of required size with 6 mm thick of approved quality laid in CM.1:2 ,10 mm thick after scrapping & cleaning the existing wall surface as instructed and pointing with white cement using 0.40Kg /Sqm. including finishing the joint and pointing flush with tiled surface including cost of cement all materials labour curing , leads lifts etc., as per standard specification complete.
Supplying and laying of Non - slippery type ceramic floor tiles of 305x305x6 mm for bath and steps etc., of approved size, quality and colour laid in CM. 1:3, 20 mm thick and pointing with white cement using 0.40Kg./m2 including finishing joint and pointing Flush with tiles surface including cost of cement, all materials, labour, curing, lead, lift etc., complete
Supplying and laying of Vitrified floor tiles for of size 600 x 600 x 8 mm double charged for Control room of approved quality and colour laid in CM. 1:3 , 20 mm thick and pointing with white cement using 0.40 Kg/m2 including finishing joint and pointing Flush with tiles surface including cost of cement, all materials,labour,curing, leads and lifts etc., complete.
Supplying and laying of joint free acid proof tiles of 8 mm tk of approved size, make and colour over CM 1:3 20mm thick in floor including pointing with white cement finishing the joints flush pointing the surface including cost of all materials, curing, labour, lead, lift, etc. complete.( Battery Room )
Providing UPVC Door and fixing casement doors fabricated from unplasticized polyvinyl chlorid (UPVC) sections .The Profile should be three chamber system which provides high insulation properties with outer frame 60mmx55mm with an outer wall thickness of 2.4mm.The window unit should be designed with all corner joint mired and fusion welded.windows should be steel reinforced with 25x24x25mm steel reinforced with thickness of 1mm to have dimensional stability.The sash should be of 602x102mm. The mullion should be of 60x74mm.The profile should have coextruded seals. The Window system should be glazed with 5mm plain float glass / 6mm bison lam.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work cost of all materials , lead, lift , etc. complete, as per standard specification
Supply and fixing of solid PVC door shutters using 19 Gauge 19mm MS square tubes for styles and outer frames,15mm MS square tubes for top,lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings.The over all size of styles shall be 50x30mm.The over all size of top rail,lock rail and bottom rail shall be 75x30mm. The over all size of frames shall be 50x45mm with suitable rabate for housing the shutter including cost of all materials, lead, lifts, labour, etc., complete.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 8mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (blackcolour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned. Radiations pin headed or Pin headed/Fluted/ Figured glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer befoe use on work and as per specications.
Providing Sintex water tank of capacity of 1000 lits including cost of material, labour, lead, lift, transportation and placing in position over head room etc., as directed by the engineer at site.
Supplying and laying PVC pipe to withstand the pressure of 10 kg/sq.cm. of approved make including cost of PVC pipe and specials, labour for cutting, laying etc ,lead,lift etc,compelte for building water supply arrangements - 32mm dia pipe
Supplying and laying PVC pipe to withstand the pressure of 10 kg/sq.cm. of approved make including cost of PVC pipe and specials, labour for cutting, laying etc ,lead,lift etc,compelte for building water supply arrangements - 25 mm dia pipe.
Supplying and fixing in position of gun metal gate valve of approved make of best quality including cost of materials, labour, lead, lift, etc., complete as directed by department Engineer at site - 32mm dia.
Supplying and fixing in position of gun metal gate valve of approved make of best quality including cost of materials, labour, lead, lift, etc., complete as directed by department Engineer at site - 25mm dia
Wiring with 2 x 1.5 sq mm PVC unsheathed multistrand copper cable of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall and covering with 3mm thick hylum sheet with steel switch box with continuous earth wire connection 14 SWG TC wire and making good the damaged portion of masonry for PVC concealed light point / fan point (for electronic regulator).
Wring with 2 x 1.50 Sq mm PVC unsheathed multistrand copper cables of 1100 V Grade in Suitable PVC regid pipe concealed in wall and ceiling with PVC accessories in flush with wall using suitable steel switch box with 3mm tick hylum sheet covers for 5 A 3 pin non inter locking CS plug including pin top with continuous earth wire connection using 14 SWG TC wire and making good the damaged portion of masonry of PVC concealed plug point.
Wring with 2x 4 Sq mm PVC unsheathed multistrand copper cables of 1100 V Grade in Suitable PVC regid pipe concealed in wall and ceiling with PVC accessories in flush with wall using suitable TW switch box with 3mm tick hylum sheet covers for 15 A 3 pin non inter locking CS plug including pin top with continuous earth wire connection using 14 SWG TC wire and making good the damaged portion of masonry of PVC concealed power plug point.
Supply and fixing of 4' 18W LED 3000k flu.type fitting complete on wall/ceiling with tubes and PVC unsheathed Copper leads from terminal to the fitting.
Supply and fixing of 4'28 W Twin type Mirror optic suspension type fitting (Philips /Crompton / Wipro) complete with louvers cover complete with copper chokes and condensor with conduit pipe suspension, with PVC unsheathed copper leads from the terminals to the fittings with flu. tubes.
Supply and fixing of bulk head fitting (Philips / Bajaj / K.Lite / Crompton Greaves) with 9 W LED bulp with guard
Supplying and fixing of 1400mm sweep AC ceiling fan with regulator with 300mm down rod on the exisitng clamps of crompton/rally/orient including cost of all materials lead, lift etc., complete.
Supply and fixing of 450 mm (18") sweep (heavy duty) AC exhaust fan complete with necessary wall opening and making good of the wall.
Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark.
Supplying and fixing of RCCB safe trip of appd LEGRAND , ISI make , 25 Amps with suitable box including cost of all materials labour, lead, lift, etc., complete as per standard specification.
Earthing as per PWD standard with an earth electrode of 2 Mtr. Class 'B' GI pipe of dia not less than 32 mm complete with necessary masonry work.
Supplying and fixing in position of floor mount European water closet of approved make & quality with 'P' or 'S' trap, PVC flushing tank with all accessories, labour ,cost of all materials,lead,lift etc,complete.
Supplying and fixing of wash basin of size 550x400 mm without pedestal of approved quality,colour and make with all accessories such as cast iron brackets,32 mm dia CP waste coupling 32 mm B class GI Waste pipe, 15mm dia pvc connecting hose,GM Gate valve,15 mm dia CP Pillar tap etc.,with all accessories, PVC/Fibre glass framed mirror of size 500 x 400 mm,5.5 mm tk and chromium plated towel rod of size 0.6 m and soap tray of size 150x100 mm including cost of all materials, labour, lead, lift, etc., complete.
Supplying and fixing in position of 12mm dia chromium plated Brass pillar cock bibcock of approved ISI make at the wash basin including cost of all material, labour, lead,lift etc complete
SUB TOTAL (Items 1 to 63)
SS BUILDERS (BID ID -1153912)
JERALIN JERISH (BID ID -1159433)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .