| 1 | L1₹7.0 LAccepted-AOC H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.7 L+₹1.7 L (24.5%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹10.0 L+₹3.1 L (44.2%)Rejected-Finance 4 BY 8 BLOCK H NEAR VIJAY CHOWK EAST DELHI DELHI 110051 | EAST DELHI | DELHI | 110051 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹10.1 L+₹3.1 L (44.9%)Rejected-Finance GALI BAWARI WALI NOHARIA BAZAAR SIRSA 125055 HARYANA | SIRSA | HARYANA | 125055 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹12 L
EMD Value
₹2.4 L
Closing Date
29 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
REPAIR TO CHAJJA, FACIA, CEILING, BALCONY AND CONNECTED WORKS IN DOMESTIC AREA AT AF STN SIRSA
2023_MES_602945_2
GE/SRA/T-29/2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹2.4 L
Yes
7 Aug 2023
14 Jul 2023
31 Jul 2023
14 Jul 2023
29 Jul 2023
15 Jul 2023
Amount
M&L for repairing of RCC projection, chajja, roof facia, column etc by necessary preparation i.e. scraping, cutting, chiselling and cleaning exposed reinforcement, surfaces of damaged, loose RCC surfaces, then applying one coat of cement slurry and filling the surface with cement concrete 1:1.5:3 using 12.50mm graded stone aggregate, Surfaces to be finished even and smooth without using extra cement incl applying a Coat of Chalk Whiting (as Preparatory Treatment) and applying Two Coats of Weather Proof Exterior Emulsion Paint over a coat of cement primer with approved Tint as per manufacturer's instructions compete all as specified and directed. NOTE:- (i) Site for application is at various locations in patches and height varies up to 12M (ii) Proper stable Scaffolding is must for working for the safety of resident of bldg and worker. Cost of all types of formwork, scaffolding & safety gear shall deemed to be included in quoted rate.
M&L for repairing of Ceiling by necessary preparation i.e. scraping, cutting, chiselling and cleaning exposed reinforcement, surfaces of damaged, loose RCC surfaces, then applying one coat of cement slurry and filling the surface with cement concrete 1:1.5:3 using 12.50mm graded stone aggregate, Surfaces to be finished even and smooth without using extra cement incl preparing new plastered Surfaces of Ceiling of any description and applying two Coat of White Wash compete all as specified and directed. Note:- (i) Site for application is at various locations in patches and height varies up to 12M (ii) Proper stable Scaffolding is must for working for the safety of resident of bldg and worker. Cost of all types of formwork, scaffolding shall deemed to be included in quoted rate.
M&L for Reinforced Cement Concrete 1:2:4, type B-1 (20mm graded stone aggregate) in Chajja, Slabs and landing etc., including demolition of existing concrete and removal of debris outsife AF land complete all as specified and as directed. NOTE : Site for application is at various locations and height varies up to 12M. Reinforcement will be Measured and Paid for separately under appropriate Item.
M&L Formwork to Chajja, slab, landing through and Similar Items including Edges for Rough Finished Flat Surfaces of Concrete, complete all as specified and as directed.
M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5cm but n exc 10cm wide complete all as specified and directed.
M&L for TMT Bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed.
M&L for TMT Bars 6.0mm to 8.0mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc and removal of debris outside AF land complete all as specified and directed.
M&L Rendering (Internal) 12mm thick, in cement mortar 1:6 on Brick Walls or on Concrete Surfaces, Plastered Surfaces finished Even and Smooth without using Extra Cement complete all as specified and as directed.
M&L for preparing New Plastered Surfaces of Walls by applying a Coat of Wall Care Putty, 1.5 mm thick including rubbing down with Sand Paper to obtain a smooth finish surface and applying with rollers Two Coats of Acrylic Distemper (as approved) over a Coat of Primer, complete all as specified and as directed.
M & L for 15 mm thick plastering in two layers, 10 mm + 5 mm in cement mortar 1:4, top layer of 5 mm thickness mixed with with water proofing compound (as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and as directed. Note : Water Proofing compound shall be measured and paid seperately as "Supply only".
Supply only Integral Water Proofing Compound, conforming to IS and/or as approved, complete all as specified.
M&L preparing New Plastered Surfaces of Walls by applying a Coat of Chalk Whiting (as Preparatory Treatment) and applying Two Coats of Weather Proof Exterior Emulsion Paint over a coat of cement primer of approved Tint as per manufacturer's instructions, complete all as specified and as directed.
M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even complete all as specified and as directed.
M&L preparing New Rough Cast Plastered Surfaces of Walls by applying Two Coats of Weather Proof Exterior Emulsion Paint over a coat of cement primer with approved Tint as per manufacturer's instructions, complete all as specified and as directed.
M&L for Brick Work with Fly-Ash Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6 including demolition of existing brickwork and removal from site complete all as specified and as directed.
M&L preparing Old Decorated/Treated Plastered Surfaces of Walls and applying One Coat of White Wash, complete all as specified and as directed.
M&L preparing Old Decorated/Treated Surfaces of Ceiling of any description and applying One Coat of White Wash, complete all as specified and as directed.
M&L preparing Old Decorated/Treated Plastered Surfaces of Walls and applying One Coat of Acrylic Distemper (as approved), complete all as specified and as directed.
M&L preparing Old Decorated/Treated Plastered Surfaces of Walls and applying One Coat of Weather Proof Exterior Paint with approved Tint as per manufacturer's instructions, complete all as specified and as directed.
M&L preparing Old Decorated/Treated Wood and Wood Based Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
M&L preparing Old Treated/Painted Steel and Iron Surfaces of any description, not otherwise described, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed.
Removing vegetation growth/shrubs(girth up to 30 CM), cutting in brick wall/concrete surface up to triple storey building carefully without damaging the existing soil, vent, water supply pipe and removing roots of plants completely and filling the gaps with PCC 1:2:4, Type B-0 finished with existing surface including all scaffolding ladder etc as required surface are n.exc. 0.36 Sqm each complete all as specified and directed.
Ajay Enterprises
AGGARWAL CONSTRUCTION CO.
YESH BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .