Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹2.4 Cr+₹12.7 L (5.54%)Rejected-Finance | ₹2.4 Cr+₹12.7 L (5.54%) | L2 | Rejected-Finance Other than L1 bidder |
| 3 | L3₹2.5 Cr+₹22.3 L (9.73%)Rejected-Finance | ₹2.5 Cr+₹22.3 L (9.73%) | L3 | Rejected-Finance Other than L1 bidder |
| 4 | L4₹2.6 Cr+₹28.5 L (12.5%)Rejected-Finance | ₹2.6 Cr+₹28.5 L (12.5%) | L4 | Rejected-Finance Other than L1 bidder |
| 5 | L5₹3.1 Cr+₹83.3 L (36.4%)Rejected-Finance POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹3.1 Cr+₹83.3 L (36.4%) | L5 | Rejected-Finance Other than L1 bidder |
Tender Value
₹2.3 Cr
EMD Value
₹3.0 L
Closing Date
22 Feb 2022, 6:00 pmClosed
CWE (AF) Bagdogra
Commander Works Engineers (AF) Bagdogra Bagdogra Airport (WB) Pin- 734 421 Tele 0353 - 2698308
PROVISION OF COMMERCIAL POWER SUPPLY AT AF STN KURSEONG UNDER GE (AF) BAGDOGRA
2021_MES_475366_3
8463/BAG/2021-22/E8
Open Tender
Civil Works - Others
Lump-sum
540 days
Kurseong
MES Contractor enlisted as Class B category b (i) b(ii) having deposited Standing Security of Rs 4,00,000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
9 documents required · 9 mandatory
₹2,000
GE (AF) Bagdogra
₹3.0 L
Yes
7 Apr 2022
25 Jan 2022
1 Mar 2022
25 Jan 2022
22 Feb 2022
8 Feb 2022
Amount
SCHEDULE 'A' PART- I (BUILDING WORKS) Note:- This Schedule is not pre-priced by MES and the pre- priced rate indicated as "Rs. 0.00" under Col- 5 signifies this fact only.
Construction of Sub Station-1 building with RCC frame structure complete all as specified and as shown on drg.
Construction of Sub Station-2 building with RCC frame structure complete all as specified and as shown on drg.
SCHEDULE "A" PART-II (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK) Details of prepriced Schedule is given in Tender documents.
SCHEDULE "A" PART-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in Tender documents.
SCHEDULE "A" PART-IV (LIGHTENING PROTECTION) Details of prepriced Schedule is given in Tender documents.
SCHEDULE "A" PART-V (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in Tender documents.
SCHEDULE "A" PART-VI (STANDBY DG SET) Details of prepriced Schedule is given in Tender documents.
SCHEDULE "A" PART- VI (MISCLLANEOUS ITEMS TO BE QUOTED BY BIDDERS) Note:- This Schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only.
INTERNAL ELECTRIFICATION Supply and fix of LED tube light FOUR feet along with fixture, 20 W T8 tubular lamp with aluminium Extruded /PC Body, PC Diffuser complete with in built driver along with batten with blue coloured end caps complete all as specified and directed. MAKE- Crompton Cat part No. LTT8-20 , Cat part for Batten- DMLN1T8-16 or Equivalent approved products .
S&F of exhaust fan with automatic back shutter louvers 250 mm sweep, power 34W, air delivery 810 CMH, RPM 1100 single phase 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 0.75 Sqmm from ceiling rose to fan including writing of MES Number 2.0 cm height with synthetic enamel paint complete all as specified and directed. Make: Bajaj Maxima DX 250 mm Exhaust Fan (White) or equivalent model in Philips, CG or Havells
S&F of round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of corner street light new generation energy saving & enviornmental friendly long life versatile pressure die-cast aluminium IP66 with high power LED as light source with acrylic cover of LED 35 Watt luminaire and suitable size of bracket with clamps complete all as specified and directed.
S&F of of submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100Volts grade, FRLS type, cables 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cables + one run of continuous earthing + PVC concealed conduit will be measured as one unit . (ii) Unit rate for cutting chases for conduits and sinking for boxes and making good are included in the lumpsum part.
Supply and Fixing of MCB SPN/ DP 6-32 Amps, 230 Volts, 50 Hz with 10 KA breaking capacity complete all as specified and directed.
S&F of MCB SP 6-32 Amps, 230 Volts, 50 Hz with 10 KA breaking capacity complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY Supply, fixing, connecting and testing NEXUST STAR NEO LED 100 watt street light made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection. 10KV SPD included efficacy : 110LM/W complete all as specified and directed.
S&F of junction box made out of 2mm thick MS sheet weather proof of suitable size including 50 Amp, TPN, aluminium busbar, cable terminal, 01 No DIN rail and 01 No MCB SP, 10KA, 6 Amps etc for terminating 4core, 10/16 sqmm UG cables.and screw etc making test point and testing complete all as specified and as directed.
Supply, fixing, connecting and testing 800 KVA step down, outdoor type 11/0.433 KV, AC double wound core type, copper wound, oil immersed, air naturality cooled with external cooling tubes, transformer delta connetion of HV side and star connection on LV side in accordance with vector symbol DyN-11 (vector group 4) and having tapping of +7.5% in equal step of 2.5% change by means of auto on load tap changing arrangement. The voltage regulation shall be as per IS including first fill of transformer oil as per IS-335 and including all fittings/accessories as specified in SSR Part-1 and IS-1180 Level 2 the transformer should have cable box on LT side and brass bushing on HT side. The limit of temp rise after continuous full laod run as specified in SSR Part-1 and IS-1180 shall be suitably adjusted to suit the maximum ambient temp prevailing at site all as specified comprising with and including the following specifications :- i) 01 No Cable box on LT side consisting of 03 Nos porcelain bushing with bushing brass rods and nuts, washers and cable glands of suitable for reception of cable LT 1100 Volts grade XLPE insulated heavy duty including gland joint complete. ii) HV bushing with arching horn on 11 KV side. iii) Oil conservator with filter type drain valve and oil level guage. iv) Explosion Vent.
Item No. 10 (Contd......) v) Thermometer Pocket. vi) Two Earthing Terminal on tank body to facilitate fixing of 32x6 GI strips. vii) One No Thermometer Dail type vapour pressure type having range 0-120 degree centigrade with maximum temperature indicator and re-setting device to maximum temperature including needle of temperature guage : Max reading pointed terminal. viii) Rating plate with terminal marking plate. ix) Oil level guage. x) Oil drain filter valve. xi) Oil filling pot on top cover with plug. xii) Air release valve/plug. xiii) First fill of transformer oil confirming to relevant IS and tested upto 60 KV dielectric strength. xiv) Inspection cover. xv) Lifting lugs and jack lifting pad support. xvi) Bi-directional plain / flanged rullers. xvii) Explosion vent with double diaphragm and sight glass.
Supply, install, testing & commissioning pedestal cubical type LT panel indoor type factory made modular construction febricated out of 3 mm thick CRCA sheet, angle iron, channels, epoxy powder coated to give a superior finish, totally enclosed dust & vermin proof with locking arrangements (compartment wise) front & back side opening system including. Overall size of each incoming & outgoing modules should not less than (350mmx350mmx550mm) and busbar chamber should be suitable for accomodating all Aluminium bus bar strips (04 Nos) fixed on porcelain insulators, and one metering module suitable for accomodating three phase volt meters & ammeter digital type, indicator lamps, cable entry/exits cut outs at bottom or upper part as mentioned below, complete electrically inter connected with copper strips for all incoming and outgoing MCCBs & accessories with fixing arrangement on PCC (1:3:6) type C-2 bed block with studs, bolts, nuts & washers and consisting of the following accessories for transformer 750 KVA (LT PANEL -1) . : (Main LT Panel) Note:Drawing for LT panel shall be first approval by Engr-in-Charge and All the copper connecting busbar for MCCBs shall have proper suports with moulded/porceline insulators. BUSBAR :- 1250 Amps rated Aluminium bus bar four pole duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/ DMC insulator bus bar support (Square/ round) insulators of suitable size and good insulation resistance
Item No. 11.00 (Contd….) INCOMING: (i) ACB 4 pole, EDO type, 415 volts, with microprocessor release of capacity 1000 Amps, 50 KA -01 No (ii) CT 1000/5 Amp -01 Set (iii) Indicator lamp LEDtype (R-Y-B) - 01 set of three (iv) Supply and fix 3 Line LCD Display Multi Function Meter in 96x96 Sqmm Flush mounted measuring & displaying parameters of like voltage, current, power factor, frequency kW. Make Legrand OUTGOING (i) ACB 4 Pole, EDO type, with microprocessor release, 415 Volts, 800 Amps, 50 KA( Outgoing for FP1 )- 01 No. (ii) MCCB 4 Pole, with microprocessor release. 415 Volts, 200 Amps, 25 KA (Spare )- 01 Nos (iii) MCCB 4 Pole, with microprocessor release. 415 Volts, 200 Amps, 25 KA (outgoing for NFS Building )- 01 Nos
All per item No 11.00 here-in-before but consisting of the following:- (Feeder Pillar 1) for Mountain Radar BUSBAR :- 1000 Amps rated aluminium bus bar four pole duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/ DMC insulator bus bar support (Square/ round ) insulators of suitable size and good insulation resistance NCOMING: (i) ACB 4 Pole, with microprocessor release, 415 Volts, 800 Amps, 50 KA - 01 No (ii) Supply and fix 3 Line LCD Display Multi Function Meter in 96x96 Sq. mm Flush mounted measuring & displaying parameters of like voltage ,current ,power factor ,frequency kW. Make Legrand (iii) Indicator lamp LED type (R-Y-B) -01 Set of three (iv) CT (800/5A) -01 Set of 03 Nos OUTGOING: (i) ACB 4 Pole, with microprocessor release, 415 Volts, 800 Amps, 50 KA - 01 No (ii) MCB TPN 20 Amp 415 Volts, (6-32) Amps,10 KA- 01 Nos (iii) Supply and fix time switches 415 V three Phase of 20 Amp rating with contactor fitted inside steel enclosure
Supply and fixing cable route indicator for HT/LT UG cable 80-100mm dia CI/MS plate mounted on angle iron 25x25x5mm and 0.8 meter long painted with two coats of blue paint for LT cable and brown paint for HT cable over a coat of red oxide and including grouted on PCC (1:3:6) type C1 of size 150x150x500mm deep in trenches along with cable complete all as specified
M&L for street light bracket made out of ISI marked GI pipe medium grade 40mm dia 1.5 mtr long bend to required shape and fixed with necessary nuts, bolts, flat iron clamps of size 25 x 6 mm (02 Nos) and washers for fixing Sodium Vapour Lamp fitting 400 W on street light poles duly painted with one coat of red oxide and two coats of aluminium paint complete all as specified and directed.
M& L for synthetic insulating mat having size 1mx2mx2 mm for LT as per IS 15652-2006 all as specified and directed.
M& L for synthetic insulating mat having size 2mx1mx2.5 mm for HT all as per IS 15652-2006 as specified and directed.
S&F 1.5 Sqmm copper cable 2 core for electric cable connection from junction box to pole complete all as specified and directed.
Supply, installation, commissioning and testing of HT feeder pillar box (CPRI approved) outdoor type of size 1.20 mtr x 1.0 mtr x 0.6 mtr, powder coated, both side openable type, double door type, canopy on the top, two side ventilation, weather and vermin proof, outer shell shall be factory made of 3.15 mm thick CRCA sheet and inner shell shall be made out of 2.00 mm thick CRCA sheet with Space heater with thermostat - 01 No including nuts, bolts and washers, suitable for 400 Amps 3 Nos Aluminium bus bar with HT insulation tape R,Y,B mounting on the HT epoxy insulator for incoming and outgoing feeder with angle iron frame of size 50 mm x 6 mm angle iron including necessary foundation complete all as specified and directed.
Supply of 1250A rated current IP-55 sandwiched TPN (100% N) bus trunking suitable for 3 Phase 4 wire, 415V, 50 Hz AC supply system. Conductor made from aluminium alloy( Cu Plating +Tin Plating ) insulated with Class F PET materials with enclosure made out of Minimum 1.5mm hot-galvanised sheet steel with RAL7035 shade paint cinfirming IK-10 degree of mechanical strength with 75KA for 1 sec short time current withstand capacity including the supply of bends, End flange , Bracket with 2 runs of Aluminium earth size 50mmx6mm strips and product design is in compliance to IEC 61439-6. Make- Legrand(For 10 RM)
Supply installation, testing and commissioning of indoor type vaccum circuit breakers having incoming VCBs, for capacity 11 KV, 630 Amp, 3 phase, 3 wire, 50 Hz, having a fault level of 350MVA at 11 KV, 13.1 KA breaking capacity totally enclosed single bus bar for each phase, floor mounting, metal clad, Indoor extensible type flush mounted, draw out type, horizontal / vertical isolation type with electrical and mechanical interlock plugs, assembly of 3 vaccum interrupters, with epoxy support insulations and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and withdrawl of VCB) manual and automatic motor charged independent closing / tgripping spring, trip free operating mechanism with clossing and tripping push buttons and mechanical breaker, including inbuild battery back up system and all standard fitting and accessories of following specifcation for incoming , outogoing and bus coupler. (01 No I/C cum O/G type) Make : Crompton Greaves / AREVA / Schnider Specification for VCBs are as under:-
Item No. 20.00 (Contd...) (i) Bus bar chamber with 3 phase copper bus bar 1000 Amp rating duly insulated 01 set (Set of three) (ii) Electrical trip coil 110 V DC - 01 No (iii) Electrical shunt coil 110 V DC - 01 No (iv) CT chamber incorporating 3 nos single phase resin cast current transformer ratio 100/50/5-5 class 1.0 for metering and class SP10 for protection and burdon 30 VA - 01 Nos (v) 3 Phase, 3 Limb draw out type bus connected oil type potential transformer, ratio 11 KV √3 / 110 V / √3 AC accuracy 1.0, burdon 200 VA - 01 No (vi) Digital ammeter 0 to 100 Amp (100% of CT ratio) for 3 phase - 01 No (vii) Digital voltmeter rating 0 to 12 KV, for 3 phase - 01 No (viii) DIGITAL load manager for amps, KW, KVA, KVAR and PF type QUASER of Emercon / L&T - 01 No (ix) Three phase over current and earty fault relay digital numerical auxiliary supply 20-110 V AC/DC CT output contacts 2 No + NC, rating 5, O/C Is = 20-200% in step of 5% E/F Os=5-80% in step 5%. (x) Auxiliary relay with 4 N/O and N/C - 01 No (xi) TNC switch and LR switch - 01 Nos (xii) RYB, ON/OFF, spring charged and discharged & VCB trip indications - 1 set (xiii) Heat control switch - 01 Nos (xiv) Space heater with theromostat - 01 No (xv) Operating counter - 01 No (xvi) Spring charging motor with starter 230 V, AC - 01 No
DG SET Supply, installation, testing and commissioning of Silent Diesel Engine driven generating set of cap 750 KVA/600 KW, 0.8 PF, at an altitude of 1850.00 Mtr above MSL (Mean Sea Level) & suitable for starting at a temperature of - 3 degree C, with suitable BHP as recommended by OEM, complete with AMF panel, control panel having meters sound proof canopy considering all derating factors with mounted on common base frame along with sound proof enclosure (acoustic enclosure), 1500 RPM, with silencer pipe independently supported from Engine to outside upto 01 meter , AVM padded foundation as per manufacturer's design, cold starting kit, battery start with suitable size cable for connection from DG Set to panel board complete with and incl the following :- (a) PRIME MOVER: Vertical diesel engine of suitable cap water cooled (Radiator mounted), closed circuit as per BS 649 or IS 10002 direct injection type turbo charged electric starting system having rated speed 1500 RPM. The DG Set shall be capable of running 24 hrs continuously with 10 % overloading for 01 hrs in every 12 hrs as per BS 5514/BS649. Engine shall be equipped with all standard fitting as per manufacturer recommendation and mounted on common base frame with following accessories as per manufacturer design :- (i) RPM cum Hrs meter. (ii) Battery charging ammeter. (iii) Ignition key/ starting with push button switch. (iv) Lubricating oil pressure gauge. (v) A-1 governor controlling. (vi) Oil temperature gauge.
Item No. 21.00 (Contd……) (vii) Water temperature gauge. (viii) Lubricating oil coolant heater. (ix) flywheel housing with flywheel to suit double bearing coupled alternator. (x) Air cleaner dry type with vaccum indicator. (xi) Lub-oil filter with filter element (xii) Radiator with fan. (xiii) Corrosion inhibitor coolant. (xiv) 12 V -02 Nos starting equipment comprising with the following :- (aa) Two Nos 12 V 180 AH maintenance free battery. Make : Exide/ Standard (ab) Battery charging alternator with inbuilt regulator. (ac) Starter motor of suitable capacity. (ad) Battery leads (copper cable) of suitable of size with brass thimbles and terminal. Make of engine:-Cummins/ Ashok Leyland/ Kirloskar Green. (b) ALTERNATOR :- Alternator rating 750KVA/600 KW, 03 phase 50 cycles, 415 Volts, 04 wires supply at NTP 0.8 PF running @ 1500 RPM self excited, self regulated mounted on a strong fabricated steel frame suitable for mounting on permanent foundation to be coupled with the above engine. The alternator shall be confirming to BS - 2613 or IS-4722. Make of Alternator:- Alstom/ Siemens/ Kirloskar Electric.
Item No. 21.00 (Contd……) (v) Set of copper bus bar for suitable capacity. (vi) Set of indicator lamps LED type(Red, Yellow, Blue). (vii) Engine protection and AC alternator protection. (viii) Digital energy meter having facility to show KWH, KW, KVA, power factor reading etc. Make: AE/ Legrand (ix) Power contactor suitable for 750 KVA DG set incl over current, earth fault protection relays, reverse power relay, alarm for high water/lub oil temp and low lub oil pressure complete with cable gland plate for cable entry etc. (e) OTHER FITTINGS :- (i) Battery charger having electric circuit consisting of triods, rectifier, capacitor and resistor etc. Note:- The battery charger should be able to charge the battery at all the time whenever electrical supply given to the battery charger through control panel are electric power point. (f) FUEL TANK:- Fuel tank of suitable capacity as per manufacturer instructions capable to store 12 hrs running of DG set, as per manufacturer design, with all pipes connecting upto fuel pumps including oil level indicating gauge in ltrs, drain and air vent plug etc. (i) The contractor shall supply 01 Years maint spare for the above Gen Set :- (aa) Fuel filter- 12 Nos (ab) Lub oil filter - 12 Nos (ac) Element air cleaner outer - 06 Nos (ad) Element air cleaner Inner - 06 Nos.
Item No. 21.00 (Contd……) (ad) Charging current - 10, 15, 20 (af) Transformer copper double wound (ag) Protection - Mains MCBs, output MCBs, overload, battery reverse, battery over charging. (h) Relay Card - 01 No (j) Aluminium bus bar 4 strip 1250 Amps capacity, incl connection - 01 Set (k) ACB 4 Pole 1250 amp, 50 KA, EDO type microprocessor release alongwith under voltage and shunt trip release earth fault relay = 02 Nos. (l) Power contactor 03 phase, 415volts, 1250Amp with auxiliary contacts (2NO + 2 NC) & coil voltage 220- 240 volts - 02 NOS incl control/ power circuit connection by suitable sizes of cable with proper size of lugs on existing panel complete all as specified. (m) SKID The engine and alternator will be coupled, alligned and mounted on a specially designed common base frame fabricated rom MS channel of suitable cross sectional area and incl supply and fixing anti vibration pads of reqd size and numbers as recommended by manufacturers for mounting of 750 KVA/600 KW DG set. (n) PCC / RCC foundation of size 6.6 mtr x 3.0 mtr x 0.45 mtr complete as per manufacturers design. Note:- (i) Contractor will satisfactorily conduct load test of DG set for 12 hours including run on 10% overload for 1 hour at their own risk, cost and arrangement. (ii) Testing eqpt will be arranged by the contractor. (iii) Fuel/ oil required for load test shall be arranged by the contractor and cost thereof is deemed to be included in the lump sum amount quoted by the contractor.
IMPORTANT NOTES: (a) Design/drawing/BOM of the AMF panel & DG SET showing the dimensions is to be obtained from DG SET/Panel board manufacturer/ Auth supplier & is to be got approved from Engr-in-Charge & GE before placing final order to the manufacturer. (b) The electrical connection of digital Multi Functional Meter in the AMF panel is to be done from load side so that monitoring of various parameters viz Voltage, Current, KW, KVA, power factor, frequency etc. can be done for both SEB mains & DG mains. (c) The cost of periodical/routine servicing including minor repairs/ replacements such as toping up of coolant, engine/ lube oil, diesel as well as lube-oil filters including periodical checking of the complete DG set & AMF panel for the complete defect liability period from the authorized service Dealer as when required/ due is deemed to be included in the unit quoted rates. (d) The complete installation, commissioning & testing of the DG Set & AMF panel is to be got done from the OEM or their auth Rep/Sister concern/Chanel Partners only. (e) Anything missed out in the technical specifications but technically required for efficient working of the DG Set & AMF Panel is deemed to be included in the quoted rates. (f) Necessary PCC foundation/ Plinth shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates. (g) The quoted rate shall be deemed to be inclusive of 12 Hrs test run at site as specified in the PS in presence of rep of Accepting Officer, all testing arrangements/ equipments, resistive load including POL shall be made available by the contractor. (h) The approximate distance between the DG Set to the AMF Panel is deemed to be included in the unit quoted rates. (j) The AMF Panel shall be completely compatible for getting started the DG Set in the event of NO EB Supply & transfer of load from EB to DG & vice-versa when EB supply resumes. (k) Contractor/Firm is required to visit the site of work for any doubts/ clarifications w.r.t specifications/qty etc. before quoting of the Tender. Any query/ clarifications etc. after conclusion of the contract shall NOT be entertained & decision of the AO shall be final & binding.
Supply and installation of automatic operation of three phase servo controlled naturally oil cooled stabilizer, copper wound indoor type and designed for input variation between 340 v to 480 v with output voltage stabilized at 415 v with accuracy ± 1% and speed of correction 08 voltage per second suitable for unbalanced load efficiency not less than 98% and of capacity 750 KVA complete all as specified and directed. The detail specification for servo controlled voltage stabilizer- (a) Technology : Servo Controlled (b) Type : 3Ph, Indoor, Unbalanced (c) Input Voltage : 340 to 480 V, AC, 3 PH (d) Out Put voltage : 415 ± 1%, 50 Hz, 3Ph and 4 wire (e) Cooling : Oil cooled (f) Insulation class : A (g) Temperature rise : 550C (h) Efficiency : 98.5- 99% at full load at unity power factor (j) Control : Auto / Manual (k) Waveform Distortion : Nil (l) Backup protection : Suitable MCCB at IP (m) Indicator : LED for each phase to indicate mains ON, output On, under voltage, over voltage, over load, single phasing & Trip (n) Winding : Cooper (o) Response time & rate of correction : Less than 10 mili seconds & 8 V/Sec
Item No. 22.00 contd......... (p) Trip : Incorporated by means of shunt operated MCCB (q) Metering : Multifunction digital meter showing voltage, cut off, frequency, KVA, KW & KVAR. (r) Protection : Overload, Short circuit, High/ low voltage cut off, single phasing prevention & bypass arrangement to be provided. (s) Oil : First filling of oil to be provided. (t) Ref Standard : IS 9815 Part I (latest) (u) fittings : Four rollers, two earthing terminals, our lifting hooks, Oil filling hole with cap, drain wall, oil levl indicaor (v) Testing : All routing tests as per DGAOA & IS to be conducted & Test reports to be furnished along with equipment (w) Duty Cycle : 24x7
Boring of hole of dia 150mm bore under road for laying of GI pipe not exceeding 90 cm below ground level complete all as specified and directed.
B D Raizada Projects Pvt Ltd
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
AVINASH ENTERPRISES
BHARAT MULTITECH INDUSTRIES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .