Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹9.7 L
Closing Date
1 Dec 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
REGISTRAR
REGISTRAR bharathiar University
Special repair work to kannamma hostel in Bharathiar university
2025_HE_624544_1
BU/UE/AEE/15D/D-918/2025-2026
Limited
Civil Works
Item Rate
100 days
Coimbatore
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
19 Nov 2025
19 Nov 2025
2 Dec 2025
19 Nov 2025
1 Dec 2025
19 Nov 2025
Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of walls
a) Doors and windows including removal of frames hinges and fastenings
b) floor finish and dadooing walls in cement mortar with mosaic tiles/ Glazod tiles/clay tiles/cuddaph slabs
c) Pressed tiles and weathering course
BRICK WORK in cement mortar 1:5 (One cement and five crushed stone sand) using Fly ash bricks of size (230 X 110 X 70 mm) for the following including curing etc., complete complying with standard specifications. (Masonry projections wherever necessary for obtaining required elevation shall be done without extra cost).
a) For Foundation and basement
b) In Super Structure ground floor
Brick partition walls of 11.50cm thickness using best quality II class table moulded chamber burnt bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the University Engineer. (Hoop iron reinforcement will be measured and paid for separately)
a) In ground floor
Plain Cement Concrete 1:2:4 (One cement, two M sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the university Engineer.
a) For Ground floor
Pointing the joints of machine pressed tiles in Cement Mortar 1:3 (One Cement and Three M Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the University Engineer.
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the University Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level
a) 75mm dia
a) 110mm dia
a) 160mm dia
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the University Engineer before use on works).
I) PVC ELBOW a) 75mm dia
b) 110mm dia
c) 160mm dia
II) PVC DOOR ELBOW a) 75mm dia
b) 110mm dia
c) 160mm dia
III) PVC TEE a) 75mm dia
b) 110mm dia
c) 160mm dia
IV) PVC TEE WITH SINGLE DOOR a) 75mm dia
b) 110mm dia
c) 160mm dia
Supplying and painting the walls with two coats of oil bound distember over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the University Engineer before use of work).
Painting two coats with Oil bound distember of approved quality and colour including preparation of surface etc., complete complying with standard specification and as directed by the University Engineer. (The paint to be used should be got approved by the University Engineer before use on work.)
Painting old wood works with one coat of best approved synthetic enamel paint over existing coat for doors, windows, in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the University Engineer before use on works.)
Supplying and painting the walls with two coats of cement paint as instructed by the University Engineer including preparation of surface curing, etc., complete in all floors complying with standard specifications (The colour and shade of the cement paint shall be got approved by the University Engineer before use of work).
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
BOQ_746873.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .