Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Quoted rates lowest and competitive | |
| 2 | L2₹36.7 L+₹2.9 L (8.67%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Quoted rate neither lowest nor competitive |
Tender Value
₹38.4 L
EMD Value
₹76,800
Closing Date
15 Feb 2020, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT-10
SPECIAL REPAIRS OF CERT ARMY T and E LAB RHQ COMPLEX RECEPTION AREA AND FORENSIC LAB OF ARMY CYBER GROUP LOCATED AT BLDG P 63 AT SIGNAL ENCLAVE UNDER GE CENTRAL DELHI CANTT-10
2020_MES_317582_1
CWE/D-60/2019-20
Open Tender
Civil Works
Item Rate
150 days
Delhi Cantt
As per NIT
8 documents required · 8 mandatory
₹500
GE CENTRAL DELHI CANTT
₹76,800
Yes
26 Feb 2020
23 Jan 2020
17 Feb 2020
23 Jan 2020
15 Feb 2020
5 Feb 2020
Amount
Demolition of cement concrete(unreinforced ) in ground floors and pavings n.exc 15 cm thicness (below of above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced) in roof ,beams, landing, chajja and similar suspended work complete all as specified and directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc.
Demolition of brick work built in cement mortar in any description and position, complete all as specified.
M & L for brick work with sub class 'B' bricks,old size , straight or curved on plan to any radius in half brick thick walls built in CM1:4 complete all as specified and directed.
M & L for brick work with sub class 'B' bricks,old size , straight or curved on plan exceeding 6 m mean radius built in CM1:6 complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each complete.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 sqm each complete all as specified
M & L for Cutting openings, through brick walls for door, window and other openings or enlarging existing openings, converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core, etc., to store and rubbish not exc. 50m built in cement mortar all as specified and directed.
M & L for Forming jambs, etc., to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete in cement mortar 1:4 all as specified.
M & L for Making good under cills or over arches, lintels and bressummers, including all-pinning when necessary in cment mortar 1:4 all as specified.®
M&L in repairs for 12 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination fixed with screws to timber frame work including necessary timber frame work with 2nd class hard wood backing with 1.2 M long on vertilcal and horizontal fixed with screws to the scantling of section exc 13 sqcm but n-exc 25 sqcm frame work .All as specified and directed.as in cup board shutter, loft shutters incl 6 mm thick teak wood lipping and necessary rebating for shutters wherever required including polishing to lipping/rebating complete all as specified.
M&L for rendering 15 mm thick in CM 1:6 on fair faces of bricks work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L 5 mm thick rendering in CM (1:3) internal face of ceiling finished fair even and smooth without using extra cement complete all as specificed and directed..
M&L for rendering 15 mm thick in CM 1:4 on fair/unfair faces of bricks work or concrete surfaces finished even and smooth using extra cement mixed with WPC @ 3% by weight of cement complete all as specified and directed..
M&L for complete removal of existing treatment from wall by washing ,rubbing down and stopping of old surfaces, preparation of old surfaces and applying two oil emulsion distemper complete all as specified and directed.
M&L preparation of newly plastered surface of walls and applying 2 mm thick wall care putty complete all as specified and directed.
M&L preparation of old plastered surface of walls complete all as specified and directed.
M& L for applying one coat of alkali resistant primer on wall surfaces complete all as specified and directed .
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
M&L for applying two coat of distemper oil emulsion over 01 coat of Alkali resistant primer on new plastered walls surfaces including preparation surface complete all as per specified and directed.
M&L for applying two coat of distemper oil emulsion over 01 coat of Alkali resistant primer on new plastered ceiling surfaces including preparation surface complete all as per specified and directed.
M&L reinforced cement concrete 1:1.5:3 type B-1 (using 20mm graded stone aggregate) as in shelves, landings, cover slabs, chullah hoods, chajjas, water trough and similar articles including form works , set in cement mortar 1:4, complete all as specified (reinforcement to be measured & paid separately).
M&L cement concret 1:2:4 type B-O (12.5 mm graded stone aggregate) as in flooring 25 mm thick, complete all as specified.
M&L for double charged vitrified coloured tile 600 x 600 x 9 to10 mm thick, as in floors, laid and jointed in neat cement slurry and pointed in coloured cement to match, over & including 15 mm thick screed bed in CM 1 :6 complete all as specified and directed by Engr-in-Charge.
M&L for double charged vitrified coloured tile 600 x 600 x 9 to10 mm thick, as in skirting/dado,set and jointed in neat cement slurry and pointed in coloured cement to match, over & including 10 mm thick plaster as backing coat in CM 1 : 4 complete all as specified and directed by Engr-in-Charge.
Cutting holes in brick wall built in cement mortar for inserting hold fasts, depth of embedded postion of hold fast /lugs measured from the face the jambs into the wall exc half brick but n.exc one brick thick and making good the dismantaled portion in cement mortar 1:3 or in cement concrete 1:2:4 type B-1, using 20mm graded stone agg complete all as specified upto six storey height.
M&L for false ceiling in repairs using plain galvanized steel ceillling system consisting of 600x600 mm lay in tiles of pre-coated galvanized sheet 0.5 mm thick in white or colour to be laid on grid system with 15 mm wide T section of size 45x15 mm flanges having rotray stiching on the main runner tie, arm runner spaced 600 mm centre flush fitting 600 mm long cross tees to be interlocked between runner at 600 mm centre to form 600 x 600 mm module perimeter trim to be wall angle od size 3000x45x15 mm secured to wall and including suspension system as per manufacturer instruction complete all as per specified and directed. Work to be executed through authorised represenatative of manufacturer
M&L for ceiling board of plain gypsum board 12 mm thick to be laid on grid system with 15 mm wide T section of size 45x15 mm flanges having rotray stiching on the main runner tie, arm runner spaced 600 mm centre flush fitting 600 mm long cross tees to be interlocked between runner at 600 mm centre to form 600 x 600 mm module perimeter trim to be wall angle od size 3000x45x15 mm secured to wall and including suspension system as per manufacturer instruction complete all as per specified and directed. Work to be executed through authorised represenatative of manufacturer .
S&F powder coated aluminium frames for door, windows , ventilators with one or more rebates including jointing cleat for fixing complete all as specified and directed.
Supply and fix aluminum anodised window and ventilators shutters sliding type without sash bars , aluminium section weighing 0.55 Kg/m including joining cleat,glazing clips , rubber packing and aluminium anodised snap beading as specified in MES SSR-1991, Part-I complete all as specified and directed.
M & L for applying two coats of synthetic enamel paint over a coat of red oxide primer to steel surfaces of any description not otherwise described exc 10 cm width/girth including preparation of new surfaces. Complete all as per specified and directed.
S&F in repairs 5.5 mm thick sheet glass ordinary quality in square n exc 0.5 sqm each with rollers ,including grinding of edges for crockery cupboards complete all as specified and directed.
S&F Ist Class hardwood, plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S& F 35 mm thick flush shutters (factory made) solid core construction, with block board core and plywood face pannel, commercial type on both sides. Flush shutters shall have teak wood edging as specified in IS and magic eye, complete all as specified.
S&F 35mm thick 2nd class plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F framed work such as grills,gates , gratings etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars complete all as specified conforming to Fe-410-0 or Fe-310-0.
S & F butt hinges 100mm size Medium weight cold rolled mild steel fixed complete all as specified.
S & F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F aluminium anodised barrel tower bolts of extruded section 200 mm long complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and directed.
S & F 150 mm long brass cast type polished bright handles complete all as per specified and directed.
S&F sheet glass ordinary quality, 4 mm thick and glazing with oil putty in square n.exc. 0.5 Sqm in each pane complete all as specified and directed.
M&L for preparation of new wooden surfaces exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
M&L TMT bars 6 to 8 mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed.
M&L reinforced cement concrete 1:1.5:3 type B-1 (using 20mm graded stone aggregate) as in shelves, landings, cover slabs, chullah hoods, chajjas, water trough and similar articles including form works , set in cement mortar 1:4, complete all as specified (reinforcement to be measured & paid separately).
M&L cement concret 1:2:4 type B-O (12.5 mm graded stone aggregate) as in flooring 50 mm thick, complete all as specified.
M&L coloured ceramic rectified tile 300x600 x7 to 8 mm thick, as in skirting/dado,set and jointed in neat cement slurry and pointed in coloured cement to match, over & including 10 mm th plaster as backing coat in CM 1 : 4 complete all as specified and directed .
M&L coloured ceramic rectified tile 300 x 300 x 7 to8 mm thick, as in floors, laid and jointed in neat cement slurry and pointed in coloured cement to match, over & including 15 mm th screed bed in CM 1 :6 complete all as specified and directed
M&L for APP based Polymeric membrane minimum weighting 3 kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric(wt.not less than 150 grm/ sqm) sealing joints by torch application as per manufacturer's instruction over a coat of bituminius primer confirming to IS 3384 @ 0.5 ltr/sqm on prepared surface of plaster, including one coat of aluminium reflective paint over the APP memberane all as specified. All as per manfacturer's instruction and work to be executed from rep of manufacturer.
Taking down carefully copper/aluminium point wiring (light/fan/ socket/power) complete from the wall by cutting/ chasing including fittings and fixtures such as switches, ceiling roses, pendants holder, regulators,sockets,light fittings etc for credit and making good the disturbed surfaces of wall, floor etc complete all as specified and directed.
Taking down carefully sub main wiring of any description.
Taking down old carefully unserviceable recess mounted 2"x2" (4x14 watt) light fitting of any make and type from the pop hard pop false ceiling without damaging the existing false ceiling structure and making good the disturbed surfaces around the light fitting with POP and matching with the existing colour.
Disconnecting elect connection and taking down of ceiling fan / Exaust fan of any make and any height, dismantling blade and removing fan alongwith blade for depositing in MES store yard complete all as specified and directed by Engr- in- Charge.
Taking down defective switch fuse main board / distribution iron clad or sheet metal enclosure/ MCB DBs with MCBs of any capacity and make including wooden board etc complete all as specified and directed.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified and as directed. Note - In case of beam, conduit will be placed on surface.
(a) One light /Ceiling fan/exhaust fan point controlled by one switch.
(b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
(d) One bell point controlled by one bell push.
(e) One light point controlled by two Nos two way switches
M&L for sub main wiring with two single core FRLS stranded copper conductor cable 1100 volts grade of size 4.0 sqmm and one single core FRLS stranded copper conductor cable 4 sqmm for earth wire in and including medium grade PVC concealed conduit with all fittings complete all as specified and directed.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 2.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one power point, all as specified and directed by Engr-in-Charge.
M&L switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
M&L switch modular type 6 amp SP two way complete all as specified and directed by Engineer in charge.
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L switch bell push Modular type 6 Amps 1W-1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
Supply & Fix Modular five stepped type electronic fan regulator 2 module 230V AC complete all as specified and directed by Engineer in charge.
S&F ceiling rose surface PVC 65x50 mm type with three terminals.
M&L bell electric (ding dong) 230 volt, SP all as specified and directed.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, lumen efficancy > 90 lumens/watt systems lumen output and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, lumen efficancy > 90 lumens/watt systems lumen output and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix surface ceiling mounted,squre LED down light fitting size (1 ft x 1 ft), 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F recessed mounting LED flat panel made from CRCA sheet steel 1 ft x 4 ft (W x L) IP 20, 42 watts 230 volts with electronic driver complete all as specified and directed.
supply and fix recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed.
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete as specified and directed.
S&F MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in repair MCB SP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply and fix in repair MCB SP 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S&F MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S&F MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
S&F MCB SP 6 to 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
MCCB 4 Pole, 415 V, Adjustable type 160 Amps with breaking capacity 16 KA.
MCCB 4 Pole, 415 V, Adjustable type 63 Amps with breaking capacity 16 KA.
MCCB 4 Pole, 415 V, Adjustable type 125 Amps with breaking capacity 16 KA.
Supply and fixing ceiling fans AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length and marking of fan no with black paint complete all as directed by Engr-in-Charge.
S & F exhaust fans AC single phase 230/240 V 1400 RPM of size 450 mm sweep with louvre shutte complete all as specified.
M &L telephone Point wiring complete with single pin 0.61mm dia copper conductor cable telephone pain taped and rip conforming to ITD specification D-3003 and ITI-113C/114C cable PVC insulated drawn though PVC concealed conduit not less than 20 mm dia for one 2 pin telephone socket out let on independent modular type board.
Supply & Fix in repair RJ-11 Telephone socket with transparent shutter 1 module on phenolic laminated sheet etc as required. Make :-Legrand Cat part No. 673052 or eqvt make.
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 20 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed) in walls all as specified and as directed.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories(Concealed) in walls all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm dia as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. wire from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
S & F sheet metal enclosure factory made double door for DB TPN 6 Way, 415 V, with 200 Amps rated busbar connected in all by chipping, cutting, etc. including all connection to MCBs and making good disturbed surfaces complete all as specified and directed.
S & F sheet metal enclosure factory made double door for DB TPN 4 Way, 415 V, with 200 Amps rated busbar connected in all by chipping, cutting, etc. including all connection to MCBs and making good disturbed surfaces complete all as specified and directed.
M&L for XLPE insulated, heavy duty under ground electric cable with stranded aluminium conductor,1100 volts grade of cross sectional area 35 Sqmm, 3.5 Core laid in trenches/fixing on wall/poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed.
M&L for XLPE insulated, heavy duty under ground electric cable with stranded aluminium conductor,1100 volts grade of cross sectional area 50 Sqmm, 3.5 Core laid in trenches/fixing on wall/poles or passing through pipe including connecting up with suitable glands, lugs, nuts and bolts wherever required and testing complete all as specified and directed.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 230 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
S&F in replacement BUS BAR cable juction box made out of CRCA sheet not less than 1.6 mm thick with 320 Amp rated aluminium 3 phase bus bar including connecting all cable with thimble on bus rail including nut and bolt and all required accessories complete all as specified and directed by engr-in-charge . Make :-As per sample.
M&L for GI water tubes Light grade with all fittings, fixed to walls/ laid on floors/in trenches of size 50 mm bore including testing complete all as specified and directed by Enginee-in-Charge.
M&L for GI water tubes Light grade with all fittings, fixed to walls/ laid on floors/in trenches of size 80 mm bore including testing complete all as specified and directed by Enginee-in-Charge.
M&L cost of exavation, cutting of walls, floor,laying and jointing of GI pipe making good surface after finshing work complete all as specified and directed by Enginee-in-Charge.
imran construction company
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .