Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 0 0 BAMUNPARA VILLAGE TOWN BALITIKURI CITY HOWRAH HOWRAH WEST BENGAL 711113 INDIA | HOWRAH | WEST BENGAL | 711113 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹15.6 L+₹85,176 (5.78%)Rejected-Finance 171 4 C ROAD BAMANGACHI SALKIA HOWRAH 711106 | HOWRAH | HOWRAH | WEST BENGAL | 711106 | L2 | Rejected-Finance L2 Bidder | |
| 3 | L3₹15.9 L+₹1.2 L (8.05%)Rejected-Finance 49 1 ISWAR GUPTA ROAD KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance L3 Bidder | |
| 4 | L4₹16.3 L+₹1.5 L (10.4%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | L4 | Rejected-Finance L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
26 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PWD Howrah Electrical Division
Office of the Executive Engineer PWD Howrah Electrical Division Onkarmal Jetia Road Howrah 711103
Commissioning of Uninterrupted Power Supply (UPS) at T.L. Jaiswal SGH , Howrah , RN-19000973, Project ID-HF192020643S000.
2021_WBPWD_320800_1
WBPWD/EE/HED/NIQ-29 of 2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
180 days
TLJ Hospital
Please refer Tender documents.
9 documents required · 9 mandatory
₹32,000
Office of the Executive Engineer PWD Howrah Electr
30 Nov 2021
29 Jan 2021
1 Mar 2021
30 Jan 2021
26 Feb 2021
12 Feb 2021
11 Feb 2021
365 days
Amount
Supply,installation, testing and commissioning of 20KVA ( 3 Phase Input & 3 Phase Output - Conventional UPS) with In-built Isolation Transformer & 30 Min Back up each (Total VAH 16128 each) Technology-True O-line Double Convertion(VFI-SS-III) including supply,delivery,installation of battery bank and battery stand (as per battery bank dimension) having base at a height of 2ft raised from the floor level (Make-APC/Numeric/Vertiv /AVO ). (For OT & Labour Room)
Input parameters
Nominal Voltage-380/400/415VAC 3Ph+N+PE
Operating Voltage Range- 323-478VAC
Operating Frequency Range- 45-55Hz.
Power Factor >= 0.99
Bypass Frequency Range- ± 10%
Harmonic Distortion(THDi) ≤ 5% at rated load
Output parameters
Output Voltage-380/400/415VAC, 3Ph+N+PE
Power Factor = 0.9
Voltage Regulation ± 1% (Balanced load)
Frequency(Online Mode)- ± 10%( With Sync Mode & Adjustable)
Frequency(Battery Mode)- ± 0.1 Hz
Harmonic Distortion(THDv) ≤ 2% (linear load) & ≤ 5% at non-linear load
Isolation transformer-Inbuilt
Crest Factor= 3:1
Cold Start = Available
Overload ≤110% for 60 min, ≤125% for 10 min, ≤150% for 60s
Efficiency= 94%
Waveform: Pure Sine Wave
Isolation Transformer: Delta to Star Inbuilt Isolation Transformer with 1:1 ratio at UPS Input to be provided . No external/Step up Transformer will be accepted
Battery
Battery : Voltage Min 384V or Above.
Battery Type- VRLA-AGM maintenance free min. (16128VAH) Mk. EXIDE.
DC Bus : Minimum 384V or above, 30 mim back up required Battery. Battery Make: Exide/Amar Raja (Quanta)
Battary Cabine: With power coated MS angle with MS sheet suiteble dimention and gadge, well air ventilation to ensure the battery optimum life cycle.Using Nyvin cable with proper rating for interlink cables and battery input and necessary acessiress.
Communication
Standard-LCD display,LED indication,RS 232 port, RS 485 port, Dry contact
Environment
Operating Temperature 0 deg C to 40 deg C
Relative Humidity Range- 0-95%(non condensing)
Noise Level- <70db
Enclosure: IP 20
Audio Alarm, Mains Fail, Battery Low Pre-alarm, Inverter Trip
Protections: Input & Output Over / Under Voltage, Single Phasing DC - High / Under Voltage, Battery Charging Over Current, Output Overload / Short Circuit / Over Temp., UPS auto ON on Mains recover
Indications: Mains - On / Fail / High / Low / Single Phasing DC - On / High, Battery - Low Pre-alarm / Low Trip Inverter - On / Trip / High / Low / Over Current
Certification : ISO 9001: 2008, ISO 14001: 2004, ISO 18001, RoHS and OHSAS 18001
CE Certification:IEC/EN 62040-1-1,IEC/EN50091-1,IEC/EN 60950 (Safety) IEC/EN 50091-2, IEC/EN 62040-2(EMC Emmission),IEC/EN 62040-3(performance & Design)IEC/EN 61000-4(EMC Emmunity) & IEC/EN 60146 (Design & Manufacture)
E.I works
Supply and laying of 4Core 25 Sq.mm. Gr. XLPE/ PVC Armoured Al Cable for working up to 1.1 KV..( Make- Gloster/ Havells / Polycab) sizes on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting (For labour Room) F1/2b.
Supply & Laying of 4Core 35 Sq.mm. Gr. XLPE/ PVC Armoured Al Cable for working up to 1.1 KV..( Make- Gloster/ Havells / Polycab ) on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting(For OT). F1/2C
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : F4/7
4Core 25 Sq. mm
4Core 35 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
4Core 25 Sq. mm
4Core 35 Sq. mm
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe/ rigid conduit and by the prelaid GI fish wire and making necy. connection as required as per GS. [E9/C1]
2x(2.5sqmm)+1x (1.5 sqmm) as ECC
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc including supplying sockets, tapes. [ 9 / F 5 ]
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as required and mending good damages to building works. E16/7.
25mm size
Supplying and fixing 415V, 63 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRCfuse as per rating. D3/4a.
Supplying and fixing 415V, 100 A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRCfuse as per rating. D3/4a.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand/ABB/L&T ) (D11/15) 4 Way
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - Legrand/ABB/L&T ) (D10/14)
4 way Enclosure
8 way Enclosure
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS (Make - Legrand/ABB/L&T ) (D6/7)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make - Legrand/ABB/L&T ) (D5/6)
Supplying and fixing 240/415 V change over (MCB module) of on din rail of existing DBs/ enclosure and necessary connection (Make- Havells/HPL) (D7/8)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment [2 way] (D9/11)
Supply & Fixing of 63A/415V Industrial Socket with Industrial Plug top 63A FP MCB (Mk.L&T cat:- DBMPS463SD) type as per direction by EIC.
Supply & laying of Single core 4X16 sqmm.+ 2X10sq mm as ECC Unarmoured flexible cu wire (KEI/Finolex/Polycab)
Supply & laying of Single core 4X25 sqmm.+2X16sq mm as ECC Unarmoured flexible cu wire (KEI/Finolex/Polycab)
Supplying & Fixing CRC sheet metal (16 SWG) JB-cum- Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. bakelite/Perspex/coloured Perspex (wall matching colour) top cover 3 mm thick flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment,painting and mending good damages to building works
300 mm x 200 mm x 65 mm . (E4/10)
Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [ Black Colour] (E5/14a)
Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [ Black Colour] (E5/14b)
Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc [ Black Colour] (E5/15a)
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.[ Black Colour] (E5/15b)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire FINOLEX/POLYCAB/KEI) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish
Average run 6 mtr. (E14/2)
Excavation of soil for installation of Earth Electrode and filling & ramming for Soft Soil. (G1/1).
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required as per GS. (G2/4a)
Earthing the installation by 2" ( 50 mm) dia ISI (M) GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level . (G1/2)
Supply & Laying 1.1KV grade Al AR cable on wall incl. S & F MS saddles of single core 16 sqmm armoured AL cable for connecting neutral earth (make- Gloster/Havells/Polycab)
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. (G3/d)
Rate should be quoted including all Taxes & LWC (if any).
Cons Engineers Co-operative Society Ltd.
Electromech Engineers Co-Operative Society Ltd.
DAS ENTERPRISE
stage.html
html • 0.05 MB
technical_608453.pdf
PDF • 0.08 MB
techsummary_608453.pdf
PDF • 0.09 MB
finance_608453.pdf
PDF • 0.04 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_608453.pdf
PDF • 0.09 MB
AOC.pdf
PDF • 0.45 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .