Loading…
Loading…
Tender Value
₹9.7 L
EMD Value
₹19,300
Closing Date
24 Sept 2026, 3:00 pm
Executive Engineer, ED-3rd Srinagar
Executive Engineer, ED-3rd Srinagar
Augmentation of 63 KVA to 100 KVA Distribution Transformer at Kauser Colony Palpora falling under the jurisdiction of ESD Nawa Kadal, ED-3rd Turnkey Basis and Augmentation of 100 KVA to 200 KVA Distribution Transformer at Gassi Mohalla Veer Side
2026_PDD_324080_1
ED-III /20 of 2026-27, Dated - 09/09/2026
Open Tender
Electrical Works
Turn-key
15 days
Office of Executive Engineer, ED-3rd Srinagar
Refer SBD, Technical specifications, Drawings
7 documents required · 7 mandatory
₹500
Executive Engineer, ED-3rd Srinagar
₹19,300
9 Sept 2026
9 Sept 2026
25 Sept 2026
9 Sept 2026
24 Sept 2026
9 Sept 2026
9 Sept 2026 - 15 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 11. Augmentation of 63 KVA to 100 KVA Distribution Transformer at Kauser Colony Palpora falling under the jurisdiction of ESD Nawa Kadal, ED-3rd (Turnkey Basis)" 2. Augmentation of 100 KVA to 200 KVA Distribution Transformer at Gassi Mohalla Veer Side falling under the jurisdiction of ESD Nawa Kadal, ED-3rd (Turnkey Basis)" | |||||
| 1.01 | Supply, Installation, Testing and commissiong 200 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminum wound, and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OCTC (Off Ckt Tap Changer))for
1. Augmentation of 100 kVA substation to 200 kVA at Gassi Mohalla Veer side. | 1 | No. | 4,04,134.32 | ₹4,04,134.32 |
| 1.02 | Dismantling of existing 100 KVA Distribution Transformer from Gassi Mohalla Veer Side and shifting of same to Store (Job includes loading/un-loading/carriage/transportation | 1 | No. | 7,190.21 | ₹7,190.21 |
| 1.03 | Supply, Installation, Testing and commissiong 100 KVA, 11/0.433kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, Aluminum wound, and with LV Cable Box having detachable Al. Gland plate with LV Bimetallic terminal connection suitable for vertical take off of cable. ( X-mer without OCTC (Off Ckt Tap Changer))for
1. Augmentation of 63 kVA substation to 100 kVA at Kauser Colony Palpora. | 1 | No. | 2,16,828.73 | ₹2,16,828.73 |
| 1.04 | Dismantling of existing 63 KVA Distribution Transformer from Kauser Colony Palpora and shifting of same to Store (Job includes loading/un-loading/carriage/transportation | 1 | No. | 5,919.88 | ₹5,919.88 |
| 1.05 | Supply, Installation, Testing and commissiong of S.T. poles 9.0 Meter long swaged Type conforming to ST 410 SP-33, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 33). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
1. Augmentation of 63 kVA substation to 100 kVA at Kauser Colony Palpora. -03 No. ST POles | 3 | No. | 17,512.38 | ₹52,537.14 |
| 1.06 | Supply, Installation, Testing and commissiong of S.T. poles 8.0 Meter long swaged Type conforming to ST 410 SP-15, IS: 2713 amended up-to date well finished and coated with black bituminous paint upto plant depth and Red-Oxide coated above ground level with earthing arrangement through bolt welded on pole of 14mm diameter, provided at height of 300mm above the planting depth which should be 1.5ms (SP 15). Top plate 3mm thick fully welded & bottom plate 35cm*35cm, 5mm thick fully welded.
1. Augmentation of 63 kVA substation to 100 kVA at Kauser Colony Palpora. -02 No. ST Poles | 2 | No. | 14,423.29 | ₹28,846.58 |
| 1.07 | Supply, Laying, stringing, testing and commissioning of 50 mm² ACSR Conductor
1. Augmentation of 63 kVA substation to 100 kVA at Kauser Colony Palpora. -100 mtrs
2. Augmentation of 100 kVA substation to 200 kVA at Gassi Mohalla Veer side. -80 mtrs | 300 | Mtr | 74.15 | ₹22,245 |
| 1.08 | Supply, installation, testing and commissioning of 240 mm² Single Core Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type including lugs/clamps/thimbles.
1. Augmentation of 63 kVA substation to 100 kVA at Kauser Colony Palpora.
2. Augmentation of 100 kVA substation to 200 kVA at Gassi Mohalla Veer side. - 30 mtrs | 30 | Mtr | 617.47 | ₹18,524.1 |
| 1.09 | Supply, installation, testing and commissioning of 120 mm² Single Core Cable, 1.1kV Grade, XLPE Insulated Stranded Conductor FRLS type including lugs/clamps/thimbles.
1. Augmentation of 63 kVA substation to 100 kVA at Kauser Colony Palpora. -30 mtrs
2. Augmentation of 100 kVA substation to 200 kVA at Gassi Mohalla Veer side. 0 mtrs | 30 | Mtr | 354 | ₹10,620 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.44 MB
SBD20.pdf
Tender Documents • 1.36 MB
BOQ_1092535.xls
BOQ • 0.28 MB
Combineapprovedkpdcl.pdf
Other Document • 28.39 MB
DTspecifications.pdf
Additional Documents • 0.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .