| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57.5 LAccepted-AOC DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | ₹57.5 L Quoted ₹58.5 L | L1 | Accepted-AOC ACCEPTED BEING LOWEST AS PER NIT |
| 2 | L2₹59.1 LRejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | ₹59.1 L | L2 | Rejected-Finance Rejected being L2 bidder |
| 3 | L3₹63.5 LRejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹63.5 L | L3 | Rejected-Finance Rejected being L3 bidder |
| 4 | L4₹65.3 LRejected-Finance | ₹65.3 L | L4 | Rejected-Finance Rejected being L4 bidder |
| Sl No | Description | Qty | Unit | M/S SMA and SONS CONSTRUCTIONS L4 | M/S ASHRAF CONSTRUCTIONS L1 | UNITED ENGINEERING CORPORATION L3 | HARPAL ENGINEERS AND BUILDERS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Servicing of Diesel Engine Generating sets of 62.5/63 KVA rating to be carried out as per schedule given as under :-
B - Check :- (Every 100 hrs or 6 Month whichever is earlier)
(i) Change lubricating oil
(ii) Change lubricating oil filters
(iii) Change fuel filter
(iv) Change coolant
(v) Check engine wiring for damage
(vi) Check drain fuel supply tank
(vii) Change by pass lubricant filter
(viii) Change air filter
(ix) Check oil pressure
(x) Change fuel water separator
C- Check:- (Every 1500 Hrs or 1 Years Whichever is earlier)
(i) Adjust valve
(ii) Steam clean engine
(iii) Replace hose if required
(iv) Check turbo charger mounting nuts
(v) Check engine oil heater
(vi) Inspect (alternator, starter etc) parts & replace if required
(vii) Clean fuel tank from inside
(viii) Change engine oil Note: (i) Maintenance of Diesel Engine Generating Set as per maintenance schedule chart (ii) Schedule of service, Diesel Gen Set Machine No Wise attached in Particular specification.
(iii) Servicing of DG set will be done by Authorised dealer of Kirloskar/ Cummins/Crompton/ Greave/ Mahindra only.
(iv) B Check and C Check spare parts will be measured and paid separately under supply only items (Fixing charge included shall be deemed in this quoted rate. | 12 | Each Job | 2,000 ₹24,000 | 5,500 ₹66,000 | 3,000 ₹36,000 | 3,000 ₹36,000 |
| 2.00 | All as per ser item No 1 here-in-before but DG set of capacity 75 KVA. | 2 | Each Job | 2,000 ₹4,000 | 6,000 ₹12,000 | 3,000 ₹6,000 | 3,000 ₹6,000 |
| 3.00 | All as per ser item No 1 here-in-before but DG set of capacity 100/ 125 KVA. | 12 | Each Job | 2,500 ₹30,000 | 8,000 ₹96,000 | 3,000 ₹36,000 | 3,000 ₹36,000 |
| 4.00 | All as per ser item No 1 here-in-before but DG set of capacity 160/ 180 KVA. | 7 | Each Job | 3,000 ₹21,000 | 9,000 ₹63,000 | 3,200 ₹22,400 | 3,200 ₹22,400 |
| 5.00 | All as per ser item No 1 here-in-before but DG set of capacity 200 KVA. | 5 | Each Job | 4,000 ₹20,000 | 10,000 ₹50,000 | 3,200 ₹16,000 | 3,200 ₹16,000 |
| 6.00 | All as per ser item No 1 here-in-before but DG set of capacity 250 KVA. | 2 | Each Job | 4,000 ₹8,000 | 10,000 ₹20,000 | 3,500 ₹7,000 | 3,500 ₹7,000 |
| 7.00 | All as per ser item No 1 here-in-before but DG set of capacity 320 KVA. | 2 | Each Job | 4,000 ₹8,000 | 15,000 ₹30,000 | 4,000 ₹8,000 | 4,000 ₹8,000 |
| 8.00 | All as per ser item No 1 here-in-before but DG set of capacity 400KVA. | 3 | Each Job | 4,000 ₹12,000 | 20,000 ₹60,000 | 4,000 ₹12,000 | 4,000 ₹12,000 |
| 9.00 | S&F in renewal fuel filter element with 'O' ring for 62.5 KVA capacities of DG Set complete all as specified and directed.
Make: Kirloskar/ Cummins/ Crompton Greaves/ Mahindra | 12 | Each | 700 ₹8,400 | 1,000 ₹12,000 | 800 ₹9,600 | 800 ₹9,600 |
| 10.00 | All as per ser item No 9 here-in-before but DG set of capacity 75 KVA. | 2 | Each | 900 ₹1,800 | 1,000 ₹2,000 | 800 ₹1,600 | 800 ₹1,600 |
Updated dates
Tender Value
₹84.5 L
EMD Value
₹1.5 L
Closing Date
17 Nov 2025, 6:00 pmClosed
HQ 133 WORKS ENGRS
HQ 133 WORKS ENGRS, C/O 56 APO, PIN- 914133
CWEK/TOKEN-95/864 EWS/2025-26-REPAIR/ MAINTENANCE OF SELF-STARTER, ALTERNATOR, LT PANELS, CHANGEOVER OF DG SETS AND SERVICE CONNECTIONS ALONGWITH BRANCH CUTTING INCLUDING MISC WORK IN THE AOR AGE E/M UNDER GE 864 EWS
2025_MES_734992_1
CWEK/TOKEN-95/864 EWS/2025-26
Open Tender
Electrical and Maintenance Works
270 days
GE 864 EWS
Class C and above and category b i
7 documents required · 7 mandatory
₹1,000
GE 864 EWS
₹1.5 L
HQ 133 WORKS ENGRS
4 Feb 2026
14 Oct 2025
25 Nov 2025
14 Oct 2025
17 Nov 2025
4 Nov 2025
14 Oct 2025 - 18 Oct 2025
21 Oct 2025
Amount
All as per ser item No 1 here-in-before but DG set of capacity 75 KVA.
All as per ser item No 1 here-in-before but DG set of capacity 100/ 125 KVA.
All as per ser item No 1 here-in-before but DG set of capacity 160/ 180 KVA.
All as per ser item No 1 here-in-before but DG set of capacity 200 KVA.
All as per ser item No 1 here-in-before but DG set of capacity 250 KVA.
All as per ser item No 1 here-in-before but DG set of capacity 320 KVA.
All as per ser item No 1 here-in-before but DG set of capacity 400KVA.
S&F in renewal fuel filter element with 'O' ring for 62.5 KVA capacities of DG Set complete all as specified and directed. Make: Kirloskar/ Cummins/ Crompton Greaves/ Mahindra
All as per ser item No 9 here-in-before but DG set of capacity 75 KVA.
All as per ser item No 9 here-in-before but DG set of capacity 100/ 125 KVA.
All as per ser item No 9 here-in-before but DG set of capacity 160/ 180 KVA
All as per ser item No 9 here-in-before but DG set of capacity 200 KVA
All as per ser item No 9 here-in-before but DG set of capacity 250 KVA
All as per ser item No 9 here-in-before but DG set of capacity 320 KVA
All as per ser item No 9 here-in-before but DG set of capacity 400KVA
S&F in renewal oil filter cartage element with O ring for 62.5 KVA capacities of DG Set complete all as specified and directed. Make: Kirloskar/ Cummins/ Crompton Greaves/ Mahindra
All as per ser item No 17 here-in-before but DG set of capacity 75 KVA
All as per ser item No 17 here-in-before but DG set of capacity 100/ 125 KVA.
All as per ser item No 17 here-in-before but DG set of capacity 160/ 180 KVA
All as per ser item No 17 here-in-before but DG set of capacity 200 KVA
All as per ser item No 17 here-in-before but DG set of capacity 250 KVA
All as per ser item No 17 here-in-before but DG set of capacity 320 KVA
All as per ser item No 17 here-in-before but DG set of capacity 400KVA
S&F in renewal air filter (both outer & inner) element with O ring for 62.5 KVA capacities of DG Set complete all as specified and directed. Make: Kirloskar/ Cummins/ Crompton Greaves/ Mahindra
All as per ser item No 25 here-in-before but DG set of capacity 75 KVA
All as per ser item No 25 here-in-before but DG set of capacity 100/ 125 KVA.
All as per ser item No 25 here-in-before but DG set of capacity 160/ 180 KVA
All as per ser item No 25 here-in-before but DG set of capacity 200 KVA
All as per ser item No 25 here-in-before but DG set of capacity 250 KVA
All as per ser item No 25 here-in-before but DG set of capacity 320 KVA
All as per ser item No 25 here-in-before but DG set of capacity 400 KVA
S&F in renewal bye pass oil lubricant oil filter cartridge element with O ring for 160/180 KVA capacities of DG set complete all as specified and directed. Make: Kirloskar/ Cummins/ Crompton Greaves/ Mahindra
All as per ser item No 33 here-in-before but DG set of capacity 200 KVA
All as per ser item No 33 here-in-before but DG set of capacity 250 KVA
All as per ser item No 33 here-in-before but DG set of capacity 320 KVA
All as per ser item No 33 here-in-before but DG set of capacity 400 KVA
S&F in renewal fuel water separator filter complete with banjo bolt and washer for 125 KVA capacities of DG set complete all as specified and directed. Make: Kirloskar/ Cummins/ Crompton Greaves/ Mahindra
All as per ser item No 38 here-in-before but DG set of capacity 160 KVA
All as per ser item No 38 here-in-before but DG set of capacity 180 KVA
All as per ser item No 38 here-in-before but DG set of capacity 200 KVA
All as per ser item No 38 here-in-before but DG set of capacity 250 KVA
All as per ser item No 38 here-in-before but DG set of capacity 320 KVA
All as per ser item No 38 here-in-before but DG set of capacity 400 KVA
Supply and change engine oil 15W 40 grade must be compatible for latest CPCB-IV norms DG set complete all as specified and directed. Make : K oil super by kirloskar/ Castrol/ Servo
Supply and replace of coolant of DG Set complete all as specified and directed. Make : K Cool by kirloskar/ Castrol/ Bosch
Supply and topping up of distilled water for battery complete all as specified and directed.
M&L for diesel exhaust fluid (DEF) for CPCB-IV Diesel Engine generating set complete all specified and directed.
S&F in renewal V belt of size, complete all as per site requirement, specified and directed. Make - Fanner or equivalent as approved by GE
M&L for cleaning of radiator assembly by dismantling of canopy, removal of radiator, cleaning of radiator with chemical, sealing of radiator tube if any leakage, pressure testing of radiator, arrest leakage by basing soldering including freight (to & fro), loading, unloading, re-assembly of canopy for 62.5 KVA DG sets complete all as specified and directed.
All as per ser item No 50 here-in-before but DG set of capacity 75 KVA
All as per ser item No 50 here-in-before but DG set of capacity 100/ 125 KVA
All as per ser item No 50 here-in-before but DG set of capacity 160/ 180 KVA
All as per ser item No 50 here-in-before but DG set of capacity 200 KVA
All as per ser item No 50 here-in-before but DG set of capacity 250 KVA
All as per ser item No 50 here-in-before but DG set of capacity 320 KVA
All as per ser item No 50 here-in-before but DG set of capacity 400 KVA
M&L for dismantling dynamo/alternator of battery charging complete servicing including renewal of bushes bearing, carbon brushes, diodes any other minor parts required all as directed and fixing on engine testing/ commissioning complete for engine having any capacity for 12 Volts complete all as specified and directed.
M&L for dismantling dynamo/alternator of battery charging complete servicing including renewal of bushes bearing, carbon brushes, diodes any other minor parts required and fixing on engine testing/ commissioning complete for engine having any capacity for 24 volts complete all as specified and directed.
Supply only tapped valves of suitable size for above mentioned DG sets (fixing charges shall deemed to be included with serial item ser No 16 here-in above) complete all as specified and directed.
S&F lead acid battery, 12 volt, 180 AH capacity complete with brass terminals including testing on load including dismantling and taking down old unserviceable lead acid battery from DG set complete all as specified and directed. Make : EXIDE Model- New X-Press/ Amron
S&F battery lead of 1.5 meter long with multstranded copper conductor of size 50 sqmm single core PVC insulated, flexible with battery terminal at one end and long tube terminal eye type at other end complete all as specified and directed.
M&L for servicing of self starter assembly of DG sets 12 Volts by dis connecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, reunion of existing teeth, bendex bushes, armature, solenoid assembly 12 Volts contact plates, jumping levels etc and rewinding the unserviceable field coil etc and varnishing complete all as specified and directed.
M&L for servicing of self starter assembly of DG sets 24 volts by dis connecting the self starter assembly from the engine and dismantling, cleaning all accessories, replacing worn-out parts like carbon brushes, penion of existing teeth, bendex bushes, armature, solenoid assembly 24 Volts contact plates, jumping levels etc and rewinding the unserviceable field coil etc and varnishing complete all as specified and directed.
S&F in renewal of turbo charger suitable for 320 KVA DG set complete all as specified and directed. Make : Graves Model No MWM TBD-V-12
S&F generator battery charger, input voltage 230V, output voltage 12V and 24V, fully automatic over boost/ float cut off charger, automatic over charge and over discharge protection battery reverse protection with indication suitable for charging storage type lead acid battery in existing LT/ DG panel including making necessary connections from charger to battery by using 10 sqmm copper conductor heavy duty cable and clamps including taking down old unserviceable battery charger complete all as specified and directed.
S&F in renewal ON load change over switch cubical type 4 pole of rating 630 Amps, confirming to IS-13947 (Part 3) with rotary handles complete all as specified and directed.
S&F in renewal ON load change over Switch cubical type 4 pole of rating 400 Amps, confirming to IS-13947 (Part 3) with rotary handles complete all as specified and directed.
S&F in renewal Offload change over switch cubical type 4 pole of rating 200A to 320 Amps, confirming to IS-13947 (Part 3) with rotary handles complete all as specified and directed.
Supply only Aluminium terminal (lugs) of 400 sqmm size.
Supply only Aluminium terminal (lugs) of 300 Sqmm
Supply only Aluminium terminal (lugs) of 240 Sqmm
Supply only Aluminium terminal (lugs) of 185 Sqmm
Supply only Aluminium terminal (lugs) of 150 Sqmm
Supply only Aluminium terminal (lugs) of 120 Sqmm
Supply only Aluminium terminal (lugs) of 95 Sqmm
Supply only Aluminium terminal (lugs) of 70 Sqmm
Repair / overhauling of electrical control panel board including addition alteration in wiring system complete with of defective parts such as Volt meter Ammeter, frequency meter indicating lamps with wiring etc complete all as specified and directed. Note :- Cost of spares shall be measured and paid separately.
S&F in renewal indicator lamp neon type red, yellow & blue complete all as specified and directed.
S&F in renewal MCCB 630 Amps, 4 pole, 415 Volts, 50 Hz AC with thermal magnetic setting with adjustable protection for over load and short circuit. The MCCB should have Ics = 100% Icu for short circuit breaking capacity of 36KA complete all as specified and directed.
S&F in renewal MCCB 400 Amps, 4 pole, 415 Volts, 50 Hz AC with thermal magnetic setting with adjustable protection for over load and short circuit. The MCCB should have Ics = 100% Icu for short circuit breaking capacity of 36KA complete all as specified and directed.
S&F in renewal MCCB 320/350 Amps, 4 pole, 415 Volts, 50 Hz AC with thermal magnetic setting with adjustable protection for over load and short circuit The MCCB should have Ics = 100% Icu for short circuit breaking capacity of 36KA complete all as specified and directed.
S&F in renewal MCCB 250 Amps, 4 pole, 415 Volts, 50 Hz AC with thermal magnetic setting with adjustable protection for over load and short circuit. The MCCB should have Ics = 100% Icu for short circuit breaking capacity of 36KA complete all as specified and as directed.
M&L for cleaning the fuel tank both internally and externally by removing all the dust / sediments etc of the various capacities of DG Set complete all as directed.
S&F in renewal L2 kit for 125 KVA DG Set complete all as per site requirement and directed.
S&F in renewal of fuel pipe as per sample for DG sets complete all as specified and directed.
S&F in renewal of fuel level indicator transparent PVC pipe of suitable dia for the fuel tanks of DG sets complete all as specified and directed.
S&F in renewal of solenoid switch suitable for 62.5 to 100 KVA DG set complete all as specified and directed.
S&F in renewal of solenoid switch suitable for 180 to 250 KVA DG set complete all as per sample and directed.
S&F in renewal of solenoid switch suitable for 320 to 400 KVA DG set complete all as per sample and directed.
S&F in renewal of electronic governor for DG Set 320 KVA to 400 KVA complete all as per sample and directed.
All as per ser item No 95 here-in-before but capacity 62.5 KVA to 160 KVA.
S&F in renewal of control wiring suitable for 180 to 250 KVA DG set complete all as specified and directed.
S&F in renewal of control wiring suitable for 320 to 400 KVA DG set complete all as specified and directed.
S&F in renewal of Microprocessor card suitable for 180 KVA to 250KVA DG set complete all as per sample and directed.
S&F in renewal of Microprocessor card suitable for 320 KVA to 400 KVA DG set complete all as per sample and directed.
M&L for repair of exhaust /silencer including dismantling cleaning and servicing complete refixing without bolt washer complete all as specified and directed.
S&F in renewal of self starter suitable for 63 KVA to100 KVA DG set complete all as per sample and directed.
S&F in renewal of self starter suitable for 160 KVA to 250 KVA DG set complete all as per sample and directed.
S&F in renewal of self starter suitable for 320 KVA to 400 KVA DG set complete all as per sample and as directed.
S&F in renewal of radiator assembly by dismantling of canopy including connection of hose pipe and nut bolt complete as per sample of 63 KVA to100 KVA DG set all as specified and directed .
S&F in renewal of radiator assembly by dismantling of canopy including connection of hose pipe and nut bolt complete as per sample of 160 KVA to250 KVA DG set all as specified and directed.
S&F in renewal of radiator assembly by dismantling of canopy including connection of hose pipe and nut bolt complete as per sample of 320 KVA DG set all as specified and directed.
S&F in renewal offload change over switch cubical type 4 pole of rating 63A to100 Amps, confirming to IS-13947 (Part 3) with rotary handles complete all as specified and directed.
S&F in renewal Al busbar 400 Amp capacity, colour code with neutral with enclosure including MCCB 250A 4pole 36KA complete all as specified and directed.
Supplying, fixing, jointing and testing LT Service cable PVC insulated, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 10 Sqmm x 2 Core, with electric connection lugs, laid in trenches/under floor or fixed naked with walls / on poles/ in ducts / in GI pipes etc. and including taking down complete all as specified and directed. Make :- Gloster/Grandly/Polycab/Havells/ Finolex / KEI
All as per ser Item No. 110 here-in-before but 6 sqmm x 2 Core
All as per ser Item No. 110 here-in-before but 4 sqmm x 2Core
All as per ser Item No. 110 here-in-before but 16sqmm x 2Core
S&F electronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60 Amps, accuracy class-I 50 Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed.
All as per ser Item No. 114 here-in-before but 3 Phase, 415 Volts.
M&L for electrical insulation tape roll of 25mm wide and 20 Mtr length (RYB) in repair/maintenance of cables joints or fixing of thimbles or colour coding of cables in panels/joints etc complete all as specified and directed.
Trimming of tree branches touching with LT over head line in the entire cantonment so as to maintaining sufficient clearance and avoid fault on over head lines complete all as specified and directed.
M&L for stretching of over head line four conductor with street light feeder complete in cantt area including fixing of spacer in between four conductor for maintaining clearance and to avoid fault on over head lines complete all as specified and directed.
S&F in renewal of 240 V, 10KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 5 to 32 Amps, in the MCB DB complete with connection testing and commissioning complete all as specified and directed
S&F in renewal of 240 V, 10KA 'B' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32 Amps, in the MCB DB complete with connection testing and commissioning complete all as specified and directed
S&F in renewal of unserviceable straight through LT joint including jointing material and excavation upto 3mtr length and make good surface after jointing of cable complete of size 25 to 50 sqmm 3.5 core complete all as specified and directed. Make - M Seal / Denson / 3M
S&F in renewal of unserviceable Straight through LT joint including jointing material and excavation upto 3mtr length and make good surface after jointing of cable complete of size 70 to 95 sqmm 3.5 core complete all as specified and directed. Make - M Seal / Denson / 3M
Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sq mm 2 core 1100 Volts grade complete all as specified and directed.
All as per ser Item No. 123 here-in-before but 4 sqmm x 2 Core
Supplying, laying, fixing, jointing and testing LT under ground XLPE insulated, galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 6 Sqmm x 2 Core, IS 7098 marked, with electric connection lugs, laid in trenches/under floor or fixed naked with walls /on poles/ in ducts /in GI pipes etc. and including taking down complete all as specified and directed.
All as per ser Item No. 125 here-n-before but 10 sqmm x 2 Core
All as per ser Item No. 125 here-in-before but 16 sqmm x 4 Core
All as per ser Item No. 125 here-in-before but 25 sqmm x 4 Core
All as per ser Item No. 125 here-in-before but 35 sqmm x 3.5 Core
All as per ser Item No. 125 here-in-before but 50 sqmm x 3.5 Core
Supply and laying GI pipe 'light grade' 40 mm in trenches, under floors, roads, along poles for protection of cables with all necessary fittings and sealing ends complete all as specified and directed. Make:- Jindal, Prakash Surya, Tata
All as per ser Item No. 131 here-in-before but GI pipe 'light grade' 50 mm
All as per ser Item No. 132 here-in-before but GI pipe 'light grade' 80 mm
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L of locally available river sand in trenches below and above / around UG cable for cable protection, in duct under & above the cables including punning around cable complete all as specified and directed. Note - Punned thickness shall only be measured and paid.
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250mm x 150mm x 40 mm laid flat width wise complete all as specified and directed.
S&F in renewal of MCCB 4 pole 250 Amps breaking capacity 36 KA, including spreader link including taking down complete all as specified and directed. Make :- L&T / Legrand / IndoAsian / ABB / Havells
M&L for continuous brick work sub class 'B' old size bricks straight or curved on plan exc 6m mean radius built in cement mortar 1.6 complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 and 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate no. 3 of SSR Part - 1, connected to earthing test point and complete all as specified and directed.
HARPAL ENGINEERS AND BUILDERS (BID ID -3470790)
UNITED ENGINEERING CORPORATION (BID ID -3475931)
M/S SMA and SONS CONSTRUCTIONS (BID ID -3470532)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_823022.xls
BOQ • 0.39 MB
TOKEN95.pdf
Tender Documents • 1.07 MB
Download all tender documents and submit your bid