| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹20.9 L+₹4.7 L (29.3%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest tenderer | |
| 3 | L3₹21.2 L+₹5.1 L (31.4%)Rejected-Finance 2549 NATHA SINGH STREET MEHNA MOHALLA BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than Lowest tenderer | |
| 4 | L4₹21.2 L+₹5.1 L (31.5%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest tenderer | |
| 5 | L5₹21.5 L+₹5.3 L (32.9%)Rejected-Finance | L5 | Rejected-Finance Other than Lowest tenderer |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
9 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Rahul Rawat
GE Utility Bathinda Mil stn
REPAIR MAINTENANCE OF DESERT COOLERS AND SINGLE PHASE VOLTAGE STABLIZER, COOLING SUMMER APPLIANCES (ACs) AND CONNECTED ITEMS OF BATHINDA MIL STATION AT ZONE A UNDER GE UTILITY BATHINDA
2021_MES_429682_1
8549/2021-22/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
class D cat b i or c i
9 documents required · 9 mandatory
₹500
GE (U) BATHINDA
₹52,000
Yes
6 May 2021
10 Mar 2021
12 Apr 2021
10 Mar 2021
9 Apr 2021
25 Mar 2021
60 days
Amount
Taking down carefully Window Type / Split Type / Cassate Type Air Conditioner 1.50 / 2.00 Ton capacity, from its location and removing dirt and dust from interior and exterior of the Air Conditioner and washing the condensor and evaporator with vami clean solution and other areas by soap solution, spraying pressurised water on condensor and evaportor with proper protection of electrical fixtures and connection, drying by blowing air, and placing in same position Window Type / Split Type / Cassate Type Air Conditioner complete all as directed by Engr-in-Charge. Note : Contractor will appoint 01 Technician and 01 helper in the AGE REF for attending and servicing the complaints day to day .
Taking down unserviceable Rotary Compressor from Air Conditioner Window Type / Split type 1.5 Ton capacity of any make & type and Supply and Fixing New Rotary Compressor of air conditioner of window Type / Split type 1.5 Ton capacity along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed by Engineer-in-Charge. Make : Hitachi / Tecumseh / GMCC.
All as per serial item No. 02 above but for air conditioner of window Type / Split type 2.0 Ton capacity. Make : Hitachi / Tecumseh / GMCC.
Taking down unserviceable Rotary Compressor 3 Phase from Cassate Type Air Conditioner 4.00 Ton capacity of any make & type and Supply and Fixing new Rotary Compressor 4.00 Ton capacity of Cassate Type Air Conditioner along with new foundation rubber pads, nut and bolts including testing on full load complete all as directed by Engineer-in-Charge. Make :Daikin/Blue Star/ Voltas.
S&F in repair Fan motor for any make of cassate type Air Conditioner complete all as directed.
S&F in repair Drain motor for any make of cassate type Air Conditioner complete all as directed.
S&F in repair Fan motor suitable for Window Type / Split type Air Conditioner of capacity 1.5 Ton / 2.0 Ton complete all as directed.
S&F in repair Fan Blade Metalic (aluminium) suitable for Window Type / Split Type Air Conditioner of capacity 1.5 Ton / 2.0 Ton complete all as directed.
S&F in repair Running Capacitor 55 mfd for Air Conditioner of any make and model complete all as directed by Eng-in-Charge. Make : EPCOS / ASIAN / SIEMENS
S&F in repair Running Capacitor 45 mfd for Air Conditioner of any make and model complete all as directed by Eng-in-Charge. Make : EPCOS / ASIAN / SIEMENS
S&F in repair Running Capacitor 80 to 100 mfd for Air Conditioner of any make and model complete all as directed by Eng-in-Charge. Make : EPCOS / ASIAN / SIEMENS
S&F in repair Running capacitor of 6 mfd for fan motor of Air Conditioneer all as directed by Engineer-in-Charge. Make : EPCOS / ASIAN / SIEMENS
S&F in repair Running capacitor of 2.5 mfd for fan motor of Air Conditioneer all as directed by Engineer-in-Charge. Make : EPCOS / ASIAN / SIEMENS
S&F in repair Thermostat Switch with knob suitable for Window Type Air Conditioner of any type and capacity complete all as directed by Engineer-in-charge.
S&F in repair Plastic Front Grill assembly complete suitable for any make of window type 1.5 / 2.0 tone Air Conditioner complete all as directed by Engineer-in-charge.
S&F in repair Evaporator cooling coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split type Air Conditioner of capacity 1.5 Ton including brazing/welding etc. complete all as directed by Engineer-in-charge.
All as per serial item No. 16 above but for Window Type / Split type Air Conditioner of capacity 2.00 Ton.
S&F in repair Condenser coil made out of copper tubing and fins at appropriate spacing complete in all respects suitable for Window Type / Split Type Air Conditioner 1.5 ton including brazing / welding etc. complete all as directed by Engineer-in-charge.
All as per serial item No. 16 above but for Window Type / Split Type Air Conditioner 2.0 ton.
M&L for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-22 upto the required pressure for 1.5 / 2.0 Ton Window Type / Split Type Air Conditioner complete all as approved and directed by Engineer-in-charge. Note :- The cost of gas R-22 is included in this item and nothing extra shall be paid on this account.
M&L for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-410 upto the required pressure for 2.00 Ton /1.5 Ton Split Type / Cassate Type Air Conditioner complete all as approved and directed by Engineer-in-charge. Note :- The cost of gas R-410 is included in this item and nothing extra shall be paid on this account.
M&L for flushing out the condensate from gas system by creating vacuum, leakage testing of the system, injecting CTC solution for demoistureing the system and gas charging by R-32 upto the required pressure for 2.00 Ton /1.5 Ton Split Type / Cassate Type Air Conditioner complete all as approved and directed by Engineer-in-charge. Note :- The cost of gas R-32 is included in this item and nothing extra shall be paid on this account.
S&F in repair Reverse valve (gun metal) for Window Type / Split Type Air Conditioner of 1.5 Ton / 2.0 Ton including copper pipe and gas charging as required complete all as directed by Engneer-in-Charge. Note :- The cost of gas is included in this item and nothing extra shall be paid on this account.
S&F in repair PCB including Remote Control for remote sensing and operation suitable for Window Type / Split Type Air Conditioner 1.5 Ton / 2.0 Ton make as approved by Engineer-in-charge. Make :LG / Voltas / Blue Star / Hitachi
S&F in repair with PCB including remote control for remote sensing and operation suitable for Cassate Type Air Conditioner 2.00 Ton / 4.00 Ton make as approved by Engineer-in-charge. Make :Voltas / Daikin / Blue Star
S&F in repair invertor PCB including remote control for remote sensing and operation suitable for window / split type (indoor and outdoor complete)air conditioner1.5/2.0 ton make as approved by Engineer-in-charge. Make : Daikin/Blue Star/Hitachi/voltas/diakin
S&F in repair indoor unit complete suitable for 1.5 Ton Split Type Air conditioner complete all as per manufacturer's instructions and as directed by Engineer-in-Charge. Make :Hitachi(ryoku)/whirlpool/ carrier (Total line)
S&F in repair out door unit complete suitable for 1.5 Ton split Type Air Conditioner complete all as per manufacturer's instructions and as directed by Engineer-in-Charge. Make :Hitachi (ryoku)/whirlpool/carrier(total line)
S&F in repair Metal clad Earth plug 32 A 3 Pole, 230V AC complete all as directed. Make :- LEGRAND/ SCHNIDER / ABB/ SIEMENS / HAVELLS.
S&F in repair Metal clad Earth Socket 32 A 3P, 230V AC complete all as directed. Make :-LEGRAND / SCHNIDER/.ABB / SIEMENS / HAVELLS
Providing labour only for attending complaints and removing of split type AC locating at ground floor / first floor /second floor/ third floor installed in Messes,offices/ Labs / MH at any location of Bathinda cantt and placing at its original position after repairing the complaints complete all as directed by Engr-in-Charge. Note ;- The spares required for repairing the compalints shall be measured and paid sepertely under respective items.
Taking out unserviceable Blower motor from the indoor unit split Type Air Conditioner of any make / type / capacity and supply and fixing new Blower motor of same make / type / capacity including nut and bolts if required complete all as directed by Engr-in-Charge.
S&F in repair PVC insulated three core multi stranded copper conductor, 2.5 sq.mm, as in wiring including connecting up and testing complete all as directed by Engineer-in- charge . Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDUSTRIES LTD / PLAZA / PARAGON / HPL / RR KABEL LTD.
Disconnecting, taking down and Shifting Air Conditioner, Window Type / Split Type up to 2 TR from existing location and fixing in other location and installing, connecting up and testing complete all as directed.
S&F in repair Copper tube, 15 mm / 18 mm dia, superior quality suitable for refrigeration and suction lines of split ACs, copper tube 9 mm dia discharge line drawn trough pipes / fixed to walls / laid on floor or roof complete all as directed by Engineer-in- Charge. Note : Copper tube, 15 mm / 18 mm dia and copper tube 9mm dia discharge line -1.00 Running Metre both copper tubes shall be measured and paid in single length Per Running Metre.
S&F in repair MCB SP 32 A 'C' curve complete all as directed. Make : LARSEN & TUBRO/ SIEMENS/LEGRAND/SCHNEIDER/HAVELLS INDIA LTD/C & S ELECTRIC LIMITED (C & S)/ABB
S&F in repair chassis unit made out of MS sheet suitable for 1.5 Ton Window Type Air Conditioner including painting with two coats of synthietic enamel paint over a coat of red oxide primer by spraying with approved shade of paint complete all as directed.
Disconnecting the electrical and water connections of desert cooler and taking down from its position installed at any floor of the building, opening the side pannels and remove the unserviceable/dirty wood wool pad/ khas khas pad, dismantled the front grill including piano type swiches, regulators, rotary switches, etc. Scratching out the old paint from inner and outer surfaces of cooler with sand emery paper and cleaning to make smooth surface and painting the inner side of the body with two coats of anticorrosive black paint and outer surface with two coats of silver ash hammerton paint with spray gun machine including painting the air direction change grill and fixing the desert cooler and its parts complete as original and at original place including making water and electrical connection and testing etc complete all as directed by Engineer-in-Charge. Note : The spares required for repairing shall be measured and paid sepertely as supply only under respective items.
Taking out the unserviceable fan motor from desert cooler of any make and type from AGE E/M (Refg) store yard and carryin to local market, dismanting the fan motor complete, removing the copper/aluminium burnt winding, cleaning the stator and rewinding the stator with super enamlled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class 'B' varnish for insulation including painting the body of fan Motor with two coats of synthetic enamel paint, reassembling the complete fan motor and re-fixing in the desert cooler at AGE E/M (Refg) store yard as per direction of AGE E/M (Refg) and testing complete all as directed by Engineer-in-Charge. Note :- (i) The rate of Material and Labour of super enamlled copper winding wire , High grade material class 'B' varnish is included in this item and nothing shall be paid extra on this account. (ii) The other spares required for repairing shall be measured and paid sepertely as supply only under respective items.
Supply only MS Shaft for fan motor of any make and type complete all as directed.
Supply only gun metal bush for fan motor of any make and type complete all as directed.
Supply only front grill complete heavy duty having minimum weight 3 Kgs made out of GI sheet including fixing plate complete all as directed by Engineer-in-Charge.
Supply only PVC connection pipe 450 mm long and 15mm dia with PTMT nuts including PVC washer complete all as directed by Engineer-in-Charge.
Supply only capacitor 4 mfd complete all as directed by Engineer-in-Charge. Make Asian/Keil/Jyoti.
Supply only PVC distributor three way superior quality complete all as specified and as directed by Engineer-in-Charge.Make and sample as approved by Engineeer-in-Charge.
Supply only PVC Eblow superior quality suitable for desert cooler of any capacity complete all as directed by Engineer-in-Charge.
Supply only PVC flexible pipe superior quality heavy duty suitable for desert cooler of any capacity complete all as directed by Engineer-in-Charge.
S&F in repair water pump for desert coolers 230 Volts, 50 Hz speed not less then 1300 RPM including nut and bolts complete all as directed by Engineer-in-Charge. Make : Crompton greaves/GEC/Nelco/Khaitan
Taking down usserviceable fan motor including fan blade ,MS legs and rubber pads from the desert cooler including supply and fixing New fan motor of copper winding 1/6 HP single phase 230 V three speed including fan blade , MS legs (set of four) and rubber pads complete all as directed by Engineer-in-Charge. Make : Crompton greaves/GEC/Nelco/American universal/Khaitan/cool home.
Supply only wood wool pads (Set of three) weight not less than 500gms superior quality complete all as directed by Engineer-in-Charge.
S&F in repair desert cooler body of size 27.5 inch x 27.5 inch x 33 inch made out of GI plain sheet of 20 SWG and side panels of 22 SWG without front grill but with and including nuts, bolts, and washer including painting the inner side of the body with two coats of anticorrosive black paint and outer surface with two coats of silver ash hammerton paint with spray gun machine complete all as directed by Engineer-in-Charge.
S&F in repair aluminium fan blade 21" dia suitable for desert cooler any make and any type complete all as directed by Engineer-in-Charge.
S&F in repair ply wood board of size 8' x 4' 12mm thich in cut sizes as required at site for desert cooler with and including support for fixing of ply wood including painting with one coats of synthetic enamel paint over a coat of pink primer complete all as directed by Engineer-in-Charge. Make: KITPLY / CENTURY PLYWOOD / DURA PLY / GREEN PLY
S&F in repair piano switch, flush type 5 Amp, 240 Volts, single pole, one way complete all as directed by Engineer-in-Charge. Make : ANCHOR / HAVELLS / SSK / LEGRAND / LEADER / MDS
S&F in repair rotary switch with PVC knob single pole to operate cooler 5 Amp, 240 Volts, single phase including testing and commissioning complete all as directed by Engineer-in-Charge. Make : ANCHOR / HAVELLS / SSK / LEGRAND / LEADER / MDS
S&F in repair PVC float valves, high pressure, with polythene float and fly-nut (PTMT) complete,screwed for iron pipe of brass ferrule, suitable for 15mm bore pipe complete all as specified and as directed by Engineer-in-Charge. Make - PRAYAG / PARRYWARE / COMMANDER / LEADER / CERA
S&F in repair 3 pin, 5 Amp top plug, 240 Volts, single phase complete all as specified and as directed by Engineer-in-Charge. Make : ANCHOR / HAVELLS / SSK / LEGRAND / LEADER / MDS
S&F in repair copper cable 3 core round of size 23/0.0076 , 3.00 Mtr long including making connection all as specified and as directed by Engineer-in-Charge. Make: HAVELLS/ FINOLEX/ KALINGA/ POLYCAB/ L&T / NICCO / GLOSTER CABLES LIMITED / ANCHOR / KEI INDUSTRIES LTD / PLAZA / PARAGON / HPL / RR KABEL LTD
M&L for cutting of burnt winding wire of transformer of Voltage stablizer 4 KVA to 5 KVA capacity and rewinding the same with supper enamelled copper winding wire of the existing guage, including varnishing, providing all high grade material and class 'B' varnish for insulation material including Suitable PCB , replacement of relay unit , volt metre, assembling and all incoming and out going connection of stablizer and testing upto entire satisfaction of Engineer-in-Charge complete all as directed by Engineer-in-Charge.
All as per serial item No. 59 above but for transformer of Voltage stablizer 2 KVA to 3 KVA capacity
All as per serial item No. 59 above but for transformer of Voltage stablizer 0.5 KVA to 1.5 KVA capacity. Note for serial item No. 59 to 61 : (i) The rate of Material and Labour of super enamlled copper winding wire , High grade material class 'B' varnish Suitable PCB , relay unit , volt metre is included in this item and nothing extra shall be paid on this account. (ii) The T & P/Vehicle will be arranged by the contractor at his own cost to carry for repair to local market and back and the cost is included in this item and nothing shall be paid extra on this account. (iii) Sample and Make of super enamlled copper winding wire and varnish high grade material and class 'B' shall be approved by Engineer-in-Charge.
Aman Enterprises
VISHAV CONSTRUCTIONS
Sandeep Enterprises
L H ENTERPRISES
Ansh Enterprises
M/s Kataria Construction Company
M/s SUPERTECH ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .