Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹14.8 L
Closing Date
8 Feb 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer TLMD-II Pampore
Executive Engineer TLMD-II Pampore
Replacement of 400 sq mm undergtound cable of 33 kV SIDCO feeder by overhead conductor upto Gantary at Grid Station Pampore
2020_PDD_112323_3
TLMD-II/30 of 2020
Open Tender
Electrical Works
Item Rate
15 days
132/33 kV Grid Station Pampore
Please refer Tender documents.
5 documents required · 5 mandatory
₹700
Yes
Convener, purchase committee, Directorate of ISM
Exempted
9 Feb 2021
1 Feb 2021
9 Feb 2021
1 Feb 2021
8 Feb 2021
1 Feb 2021
120 days
Amount
Supply, erection, testing, installation and commissioning of following equipments
11Mtr long ST Poles Confirming to IS:2713 (Part I, III):1980 (latest edition) Min tensle strength- 55 kgf/sqmm Type- Swagged poles and the same shall be made of seemless welded tubes of suitable lengths and jointed together
0.2 ACSR Conductor 200 mm² ACSR Conductor,(a) Alumunium=30/3 mm(b) Steel=7/3 mm Overall dia 21mm.Approximate Wt 976Kg/Km Ultimate breaking Load=89.67 KN;including 1.5%sag and jumpering
100x50x50x6mm Channel Iron
50x50x6mm Angle Iron
33 kV Pin Insulator with GI pins Minimum creepage distance 580 mm Minimumfailing load 10 KN Power frequency withstand coltage 95 KV rms (Dry) and 75 kV rms (wet) Make:- Bajaj, Birla
120 KN Disc Insulator Disc Insulators 120 KN,Ball & Socket type, 145mm height and 280mm dia. Creepage total 430 mm and 260 mm protected
0.2 Tension fittings Type- Bolted (7 bolts) Weight- 17 kg + 10% Material- Alloy steel Safe working load- 6 Ton Proof load- 12 ton
0.2-0.2 T-Clamps made of Alluminium Alloy (Galvanized) and shall comply in all respects with IS:5561-1970 (latest edition)
PG Clamps made of Alluminium Alloy (Galvanized) and shall comply in all respects with IS:5561-1970 (latest edition)
70KN Disc Insulators Specification as per IS:731/1971 RA 2001 Creepage Distance: 320 mm Minimum Mechanical Failing Load: 70 KN Nominal System Voltage:- 11 KV Highest System Voltage:-12 KV Make:- Bajaj, Birla
0.2 suspension fittings Single Suspension Fittings for panther shall have minimum failing load of 50% ultimate strength of bundle conductors with Forged Steel Hanger free center type without bolt only having slipping strength 15% of ultimate strength of conductor.The ball and socket designation must be 16 mm. (3 No,S/C 6NoD/C Per Sus. Tower)
CT Foundation (as pre drawing)
Foundation Bolts
Marshalling Kiosk Marshalling kiosk with Kiosk frames mild steel structural sections for pressed and shaped cold-rolled sheet steel, thickness not less than 2.0 mm. Frames shall be enclosed in cold-rolled sheet steel of thickness not less than 1.6 mm. Doors and covers shall also be cold rolled sheet steel of thickness not less than 1.6 mm. complete structures shall be rigid, selfsupporting, free from flows, twists and bends. Dust and vermin proof construction and shall be provided with a degree of protection of IP: 55, with Copper Bar earthing. Finishing paint on panels shall be of shade 692 (smoke grey) of IS: 5. The inside shall be properly stoved. The paint thickness shall be at least 50 microns
Cable glands of sizes
36kV, 50c/s , 2500 Amp, 25kA for one second, Ac motor operated horizontal double break, outdoor type 3 pole Isolators with One Earthing Blades and bimetallic pad clamps
G.I wire for Guard Netting of line near Sheds
Nuts,Bolts & washers of sizes (Galvanized)
Cement bottoming 1:2:4 mix as per REC standards .6cum/pole
Earthing complete GI Pipe 40 mm with 2.5 mtr long through GI Strip
Red oxide
Alluminum Paint
Labour part for below mentioned works
Laying & fixing of control Cables of sizes (available at site)
Errection,fixing, Testing & Comissioning of CT (available at site)
Dismantling, dragging & Re-Errection, testing & commissioning of 33kv breaker (available at site)
Dismantling & Re-Fixing of CT structure (available at site)
M/S MALIK BUILDERS
M/S NEW ASIA SANITARY WORKS
M/s B. L. TRADERS
stage.html
html • 0.02 MB
finance_220203.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .