| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹33.7 LAdmitted-Finance 54 KATCHERY ROAD DR B N VERMA ROAD AMINABAD LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L1 | Admitted-Finance | ||
| 2 | L2₹42.5 L+₹8.8 L (26.0%)Admitted-Finance | L2 | Admitted-Finance |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
20 Aug 2026, 6:00 pmClosed
COMMISSIONER
MUNICIPAL COUNCIL SALUMBER
Electrification work including installation of elctric poles overhead line street lights amd allied electrical works AMC
2026_DLB_586112_2
ENIT 08
Open Tender
Civil Works
Percentage
365 days
MUNICIPAL COUNCIL SALUMBER
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
MUNICIPAL COUNCIL SALUMBER
₹90,000
Yes
24 Sept 2026
12 Aug 2026
21 Aug 2026
12 Aug 2026
20 Aug 2026
12 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing & Fixing of ISO certified company made bakelite fuse fitting for HBC fuse links (front/bus bar connections) Conforms To IS 13703/IEC 269 w/o HBC fuses as per PWD specification for electrical Works on existing board including making connections with lugs, testing etc. as required. Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 100/125 A rating | 1 | Each | 900 | ₹900 |
| 2 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 25.0 Sq. mm 3.5 core | 1 | Mtr | 292 | ₹292 |
| 3 | 10.0 Sq. mm 4 core | 1 | Mtr | 197 | ₹197 |
| 4 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in- charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating | 1 | Each | 192 | ₹192 |
| 5 | 40 A rating | 1 | Each | 425 | ₹425 |
| 6 | Four pole MCB (With B/C curve tripping Characteristics) 50/63 A rating | 1 | Each | 1,789 | ₹1,789 |
| 7 | Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . One day reserve (Analog type ) | 1 | Each | 4,500 | ₹4,500 |
| 8 | One day & week reserve (Analog type ) | 1 | Each | 4,807 | ₹4,807 |
| 9 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 3 pole MCCB With Thermal Magnetic release 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting | 1 | Each | 6,547 | ₹6,547 |
| 10 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . Electrolytic grade Aluminium bus bar 6010 grade | 1 | Kg. | 556 | ₹556 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_1041135.xls
BOQ • 0.32 MB
ANNEXURE.pdf
Tender Documents • 2.06 MB
ENIT08TANDC.pdf
Other Document • 2.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .