| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 CrAccepted-AOC | ₹25.7 Cr Quoted ₹25.9 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹27.9 CrRejected-Finance BHAGWATI BHAWAN PO HASIMARA DIST JALPAIGURI PIN 735215 | ALIPURDUAR | WEST BENGAL | 735215 | ₹27.9 Cr | L2 | Rejected-Finance Other than L-1 Bidder. |
| 3 | L3₹28.7 CrRejected-Finance | ₹28.7 Cr | L3 | Rejected-Finance Other than L-1 Bidder. |
| 4 | L4₹28.8 CrRejected-Finance | ₹28.8 Cr | L4 | Rejected-Finance Other than L-1 Bidder. |
| 5 | L5₹29.8 CrRejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹29.8 Cr | L5 | Rejected-Finance Other than L-1 Bidder. |
Tender Value
₹29.5 Cr
EMD Value
₹15 L
Closing Date
22 Sept 2023, 6:00 pmClosed
CE SILIGURI ZONE
HQ CE SILIGURI ZONE, MES, SEVOKE ROAD, PO SALUGARA, JALPAIGURI, 734008 (WB)
PROVN OF OTM ACCN (PH-II) AT SUKNA UNDER GE (P) SILIGURI
2023_MES_612951_1
98764/SUK/SZ/E8
Open Tender
Civil Works
780 days
GE(P) SILIGURI
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE (P) SILIGURI
₹15 L
Yes
HQ CE SILIGURI ZONE
22 Dec 2023
9 Aug 2023
29 Sept 2023
9 Aug 2023
22 Sept 2023
15 Sept 2023
16 Aug 2023 - 22 Aug 2023
21 Aug 2023
Amount
BUILDINGS & STRUCTURE (Sch 'A' PART-I)
Lump sum price worked out by the Contractor for “BUILDINGS & STRUCTURE” as listed in Schedule ‘A’ Part-I. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 23,80,59,700.00 inserted by the MES in Schedule ‘A’ Part-I.
EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT (Sch 'A' PART-II)
Lump sum price worked out by the Contractor for “EARTHWORK, SITE CLEARANCE AND SITE DEVELOPMENT” as listed in Schedule ‘A’ Part-II. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 88,42,515.24 inserted by the MES in Schedule ‘A’ Part-II.
INTERNAL WATER SUPPLY (Sch 'A' PART-III)
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-III. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 4,73,925.89 inserted by the MES in Schedule ‘A’ Part-III.
INTERNAL ELECTRIFICATION (Sch 'A' PART-IV)
Lump sum price worked out by the Contractor for “(INTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-IV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 67,91,748.41 inserted by the MES in Schedule ‘A’ Part-IV.
ROAD, PATH, CULVERT & HARDSTANDING (Sch 'A' PART-V)
Lump sum price worked out by the Contractor for “(ROAD, PATH, CULVERT & HARDSTANDING)” as listed in Schedule ‘A’ Part-V. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,77,87,974.90 inserted by the MES in Schedule ‘A’ Part-V.
SEWAGE DISPOSAL (Sch 'A' PART-VI)
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part-VI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 11,55,572.50 inserted by the MES in Schedule ‘A’ Part-VI.
AREA DRAINAGE (Sch 'A' Part-VII)
Lump sum price worked out by the Contractor for “(AREA DRAINAGE)” as listed in Schedule ‘A’ Part-VII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 85,43,905.64 inserted by the MES in Schedule ‘A’ Part-VII.
RCC / JAFFARI SECURITY WALL , FENCING & GATE (Sch 'A' PART-VIII)
Lump sum price worked out by the Contractor for “(RCC / JAFFARI SECURITY WALL , FENCING & GATE)” as listed in Schedule ‘A’ Part-VIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,85,72,890.99 inserted by the MES in Schedule ‘A’ Part-VIII.
PROTECTIVE WORK (Sch 'A' PART-IX)
Lump sum price worked out by the Contractor for “PROTECTIVE WORK” as listed in Schedule ‘A’ Part-IX. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 11,89,481.68 inserted by the MES in Schedule ‘A’ Part-IX.
SPECIAL B/R ITEMS FOR GLASS DOOR, CURTAIN GLASSED (Sch 'A' PART-X)
Lump sum price worked out by the Contractor for “SPECIAL B/R ITEMS FOR GLASS DOOR, CURTAIN GLASSED” as listed in Schedule ‘A’ Part-X. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 3,76,073.26 inserted by the MES in Schedule ‘A’ Part-X.
EXTERNAL WATER SUPPLY (Sch 'A' PART-XI)
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part-XI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 8,22,556.58 inserted by the MES in Schedule ‘A’ Part-XI.
EXTERNAL ELECTRIFICATION (Sch 'A' PART-XII)
Lump sum price worked out by the Contractor for “(EXTERNAL ELECTRIFICATION)” as listed in Schedule ‘A’ Part-XII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 75,49,666.86 inserted by the MES in Schedule ‘A’ Part-XII.
WATER COOLER (Sch 'A' PART-XIII)
Lump sum price worked out by the Contractor for “(WATER COOLER)” as listed in Schedule ‘A’ Part-XIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 6,97,928.52 inserted by the MES in Schedule ‘A’ Part-XIII.
REFRIGERATION (Sch 'A' PART-XIV)
Lump sum price worked out by the Contractor for “(REFRIGERATION)” as listed in Schedule ‘A’ Part-XIV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,47,394.74 inserted by the MES in Schedule ‘A’ Part-XIV.
LIGHTNING PROTECTION (Sch 'A' Part-XV)
Lump sum price worked out by the Contractor for “(LIGHTNING PROTECTION)” as listed in Schedule ‘A’ Part-XV. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 1,57,037.09 inserted by the MES in Schedule ‘A’ Part-XV.
SOLAR HOT WATER (Sch 'A' PART-XVI)
Lump sum price worked out by the Contractor for “(SOLAR HOT WATER)” as listed in Schedule ‘A’ Part-XVI. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 5,89,771.92 inserted by the MES in Schedule ‘A’ Part-XVI.
AIR CONDITIONING (Sch 'A' Part-XVII)
Lump sum price worked out by the Contractor for “(AIR CONDITIONING)” as listed in Schedule ‘A’ Part-XVII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 97,843.50 inserted by the MES in Schedule ‘A’ Part-XVII.
DEMOLITION / DISMANTLING OF EXISTING BUILDINGS (Sch 'A' Part-XVIII)
Lump sum price worked out by the Contractor for “(DEMOLITION / DISMANTLING OF EXISTING BUILDINGS)” as listed in Schedule ‘A’ Part-XVIII. Representing ** ___ % ______ percent *Above / Below the lump sum price of Rs. 35,23,596.22 inserted by the MES in Schedule ‘A’ Part-XVIII.
MISCELLANEOUS ITEMS REQUIRED FOR B/R & E/M SERVICES (Sch 'A' Part-XIX)
ROAD, PATH & CULVERT Construction of 7.90 mtr RCC culvert incl excavation of earth work, PCC (1:3:6) type C-2 in fdn, Brick work in CM (1:6) in wall, RCC M-25 Design Mix Slab, Brick work in parapet, rendering in CM (1:4) and white washing complete all as shown on drawings.
Construction of 7.90 mtr long and 600 mm dia RCC NP2 Hume pipe Culvert including excavation of earth work, PCC (1:3:6) type C-2 in fdn, Brick work in parapet, rendering in CM (1:4) and white washing complete all as shown on drawings.
INTERNAL WATER SUPPLY S & F two way bib cock 16 mm dia complete all as specified and directed.
S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) complete all as specified and directed.
S & F Angular Stop Cock 15 mm dia, quarter turn complete all as specified and directed.
S & F Sink Cock with swinging casted round shape spout 15 mm dia complete all as specified and directed.
S & F shower wall mixer 15 mm 2-in-1 complete all as specified and directed.
INTERNAL ELECTRIFICATION S & F modular type, single module, RJ-11 telephone socket with shutter complete all as specified and directed.
S & F modular type 3 pin 25/32 A socket, 415 V conforming to IS 1293: 2005 and in IS 732: 2019 complete all as specified and directed.
S & F modular type 25/32 A SP MCB, conforming to IS 60898- 1: 2002 and in IS 732: 2019 complete all as specified and directed.
S & F single pole & neutral, modular type, 6 ways, 240 volt, double door, metallic distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for DP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. Note: DP RCCB / RCBO / Isolator / MCB & SP MCBs shall be measured and paid separately under relevant item.
S & F of 160 A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 25 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply complete all as specified and directed.
S & F MCB 16-32 A, 230 V, 50 Hz, DP ('C' curve) having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed.
S & F MCB 40-63 A, 230 V, 50 Hz, DP ('C' curve) having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed.
S & F MCB 40- 100 A, 415 V, 50 Hz, FP ('C' curve) having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed.
S & F 3-star (EEL) T-shape lamp capable delivering 1000 lumen having luminous efficacy of >100 lm/W, starting time <0.5 s, CRI >80, CCT 6500K, PF>0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed.
M&L for sub-main wiring with PVC insulated unsheathed FR-LSH cable 1100 Volts grade of size 4.00 Sqmm x two run alongwith earth continuity wire connected from main earth of size 4 Sqmm x single run, ISI marked, multistandard electrolyte copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall / fixed to roof, ceiling etc of size 25 mm as required including cutting chases for conduit and making good of disturbed surfaces complete all as specified and directed. NOTE : (a) Phase & neutral conductors (02 runs), earth continuity conductor (01 run) and surface / recessed conduit (01 run) shall be measured combined as one length. (b) Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
M&L for sub-main wiring with PVC insulated unsheathed FR-LSH cable 1100 Volts grade of size 6.00 Sqmm x two run alongwith earth continuity wire connected from main earth of size 6 Sqmm x single run, ISI marked, multistandard electrolyte copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall / fixed to roof, ceiling etc of size 25 mm as required including cutting chases for conduit and making good of disturbed surfaces complete all as specified and directed. NOTE : (a) Phase & neutral conductors (02 runs), earth continuity conductor (01 run) and surface / recessed conduit (01 run) shall be measured combined as one length. (b) Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
M&L for sub-main wiring with PVC insulated unsheathed FR-LSH cable 1100 Volts grade of size 6.00 Sqmm x four run alongwith earth continuity wire connected from main earth of size 6 Sqmm x two run, ISI marked, multistandard electrolyte copper conductor single core cable drawn in and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall / fixed to roof, ceiling etc of size 25 mm as required including cutting chases for conduit and making good of disturbed surfaces complete all as specified and directed. NOTE : (a) Phase & neutral conductors (04 runs), earth continuity conductor (02 run) and surface / recessed conduit (01 run) shall be measured combined as one length. (b) Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
SEWAGE DISPOSAL Supply and laying DWCPE (SN8) 180 (OD)/163(ID) mm diameter pipes line including necessary joining and laid in trenches as per drawing in any length to make sewer line functional and testing complete all as specified and directed.
Provn of RCC Septic tanks, exc in ordinary soil, foundation in PCC (1:2:4) , brick work in CM (1:4) RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc., complete for 100 users all as specified and shown on drawings.
Provn of RCC Septic tanks, exc in ordinary soil, foundation in PCC (1:2:4), brick work in CM (1:4) RCC slab covers including RCC precast manhole cover having 6 mm plate embedded all around/fibre reinforced cover with angle iron frame vent shaft and sludge chambers etc., complete for 50 users as specified and shown on drawings.
Provn of RCC Soakage well exc. In ordinary soil, foundation in PCC (1:3:6) wells of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in CM , RCC cover slub in M-25 /RR masonry/filling with brick bats, complete of size 1.7 M dia x 7.5 M deep as specified and shown on drawings.
Provn of RCC Soakage well exc. In ordinary soil, foundation in PCC 1:3:6 wells of honey combed and solid in M-25 concrete, including intercepting chamber, screen chamber brick work in CM , RCC cover slub in M-25 /RR masonry/filling with brick bats, complete of size 1.8x dia X 3.0 M deep as specified and shown on drawings.
PROTECTIVE WORK S&F of geosynthetic material 75mm dia as in weep hole cover complete all as specified and directed.
SPECIAL B/R ITEMS M&L for construction of MS steel gate with RCC pillar on either side of gate including all necessary excavation, earth work, PCC foundation, reinforcement comprising of 8 Nos 12 mm TMT bar main reinforcement and 8mm dia. stirrups @ 150mm C/C including formwork, plaster 15mm thick in CM (1:4) with surface, Granite/ marble stone on RCC pillar/column, Arch shape MS steel plate over column with decorated Letter complete all as specified and as directed.
S&F 12 mm thick automatic 3 panel sliding Glass door with suitable frame work and fixing on wall and floor as per manufacturer instruction all as specified and as directed.
EXTERNAL WATER SUPPLY Construction of brick masonry valves pits, of internal dimension 900mm x 900mm x 900mm complete with 3.15 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete all as specified and directed.
Construction of brick masonry valves pits, of internal dimension 600mm x 600mm x 600mm complete with 3.15 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for upto pipe of 150 mm dia work complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply and laying sub class "B" bricks in trenches for protection of UG Cable with width equal to length of bricks, laid dry & flat complete all as specified & as directed.
Supply, installation, testing and commissioning of transformer platform/plinth mounted of capacity 250 KVA level - 2, step down, outdoor type 11.0/0.433 KV, 50 Hz, AC double wound core type, copper wound, oil immersed type, naturally air cooled with external cooling tubes, transformer delta connection on HT side & star connection on LV side in accordance with vector symbol DyN 11 (vector group - 4) with off-load tap changer on HT side to vary secondary voltage +5%/-15% in equal steps of 2.5% as per IS - 1180 (Part - I) 2014. The voltage regulation shall be as per IS including first fill of transformer oil upto appropriate level all as per IS-335 all as specified & as directed comprising with & including the following specifications : (a) 01 No cable end box on HT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of HT 11000 V grade XLPE insulated heavy duty cables including glands complete. (b) 01 No cable end box on LT side consisting of 03 Nos porcelain bushing with bushing brass rods, nuts, washers & cable glands suitable for reception of LT 1100 V grade XLPE insulated heavy duty cables including glands complete. (c) Oil conservator with filter type drain valve & oil level gauge. (d) Explosion vent with double diaphragm & sight glass. (e) Thermometer pocket. (f) Two earthing terminal on tank body to facilitate fixing of 32 x 6 mm GI strip etc. Item Continued as 19.33
M&L for Boring hole under the existing road or PCC hard standing without damaging the surface of the road suitable for inserting upto 150 mm bore pipe at a depth 0.75 to 1.0 mtr complete all as specified and directed.
Supply, installation, testing and commissioning out door type LT feeder pillar box of suitable size, pedestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portion and 2.00 mm thick for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Platform made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete all as specified and directed with the following items housed in :- (Main Panel) Item Continued as 19.36
S&F junction box made out of polycarbonate with IP 55/IP 65 protection of suitable size including - 04 Nos cable terminal, 02 Nos polycarbonate cable gland , 01 Nos DIN rail and 01 No. MCB SP, 10 KA 6 to 10 Amps and proper clamping system to pole complete all as specified and directed.
Fabrication, supply and installation of glow sign board size 3' x 2.5' made out of ACP (Aluminium composite panel) sheet of 4mm thick vinyl sticker, reflecting sticker sheet (deep navy blue), letter of size not less 15cm with bracket around the ACP panel Sheet of Stainless Steel pipe size 15mm dia and 2 Nos vertical post made of Stainless steel of dia not less than 50mm and length not less than 2.5 mtr including excavation of post holes in soft/loose soil, PCC for post holes complete all as specified and directed.
S&F Cone NXG Led bollard light fittings, IP-65 protection, 8W with complete fittings. all as specified and directed. (For landscap lighting)
S&F time switches 415 volts three phase of 20 Amp rating with contactor fitted inside steel enclosure complete all as specified and directed.
M&L for cable route indicator using RCC post 1.20 mtr long, top 100 x 100 mm & bottom 200 x 200 mm, with height not less than 50 cm above GL with engraved marking " HT CABLE " in bold letters during refilling of the trench complete all as specified and directed. NOTE : The spacing between two consecutive cable route indicators shall not be more than 50.0 meters & also shall be provided at each & every bend or corner.
M&L for cable route indicator using RCC post 1.20 mtr long, top 100 x 100 mm & bottom 200 x 200 mm, with height not less than 50 cm above GL with engraved marking " LT CABLE " in bold letters during refilling of the trench complete all as specified and directed. NOTE : The spacing between two consecutive cable route indicators shall not be more than 50.0 meters & also shall be provided at each & every bend or corner.
Fabrication, supply, installation and commissioning of 3D LED sign boards fabricated out of 3mm thick blue coloured acrylic sheet and base 4mm ACP sheet (out door, with IP-65) for main gates of unit with timer (on each board) of L & T equivalent . ACP sheet fitted on double frame fabricated out of 32mm X 32mm MS Square pipe, having 3” depth. All five sides of frame covered with ACP Sheet and back side covered with 26 guage GI sheet. Acrylic letters fabricated out of 3mm thick acrylic A Grade/imported sheet, having minimum 2” depth. Logo of suitable dimension and Text matter alphabets raised 2 ½” LED modules with IP-65 grade to eliminate the letter to the satisfaction of Engineer-in-charge. Power supplies/drivers must be IP-65. Matters with size and logo of each sign board will be decided by users at the time execution complete all as specified and directed.
Fabrication, supply, installation and commissioning of required supporting MS structure, wherever needed, using MS angle, sheet, C channel with complete nut bolts and required materials and scaffolding complete all as specified and directed.
Supply, installation, testing and commissioning of silent built in within an acoustic enclosure diesel engine driven generating set water cooled including AMF panel for standby power supply 415 volts, 03 Phase, 4 wire, 50 cycles / sec, 50 KVA (40.0 KW) at 0.8 power factor complete with alternator directly coupled to diesel engine, mounted on common base frame & complete with self starter 12 volt, fuel tank capacity not less than 12 hours fuel requirement & battery 12 volts 180 AH lead acid type, battery leads, sound proof canopy etc. with features for automatic shutdown in the event of a circuit failure condition arising from low oil pressure, high coolant temperature, over speed etc. & PSO500 genset controller with the following under-mentioned features and confirming to latest CPCB norms incl foundation of DG set as per manufacturer specification complete all as specified and directed :- (a) 16 character x 2 line alphanumeric LCD display with LED backlight. (b) Operator interface. (c) Suitable to provide a record of most recent fault conditions & fault history. (d) Complete alternator data viz, voltage ph - ph, ph - neutral, KVA , frequency etc. (e) Complete engine data viz, starting battery voltage, engine temp, engine running hours, engine oil pressure etc. (f) Control including provn of service adjustment & calibration of DG control functions. GENSET SPECIFICATIONS :- (i) PRIME MOVER RATING : 50 KVA / 40.0 KW (ii)CURRENT RATING : 70 A (iii) NO OF PHASES : 03 (iv)POWER FACTOR : 0.8 (LAG) Item continued as 19.50
WATER COOLER S&F voltage stabilizer for automatic operation, copper wound, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with out put voltage stabilized at 230 volts with accuracy of + 2.5% and capacity 1 KVA with high/low voltage auto cut off feature complete all as specified and directed.
S&F voltage stabilizer for automatic operation, copper wound, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts without put voltage stabilized at 230 volts with accuracy of + 2.5% and capacity 2 KVA suitable for above water cooler with high/low voltage auto cut off feature complete all as specified and directed.
REFRIGERATION Supply, Installation, testing and commissioning of Refrigerator electric driven single phase having capacity minimum 270 Ltrs frost free working with non CFC refrigerant and minimum 3 star rating complete all as specified and directed.
Supply, Installation, testing and commissioning of Refrigerator electric driven single phase having capacity minimum 235 Ltrs frost free working with non CFC refrigerant and 5 star rating complete all as specified and directed.
Supply, Installation, testing and commissioning of Refrigerator electric driven single phase having capacity minimum 165 Ltrs frost free working with non CFC refrigerant and 5 star rating complete all as specified and directed.
AIR CONDITIONING S&F voltage stabilizer for automatic operation, copper wound, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts without put voltage stabilized at 230 volts with accuracy of + 2.5% and capacity 4 KVA suitable for above water cooler with high/low voltage auto cut off feature complete all as specified and directed.
DEMOLITION / DISMANTLING OF EXISTING BUILDINGS M&L for taking down service connection cable complete all as specified and directed.
M&L for taking down dismantle PCC pole / Steel tubular pole complete all as specified and directed.
M&L for taking down street light fittings complete all as specified and directed.
M&L for taking down ACSR conductor complete all as specified and directed.
Taking down carefully copper / aluminium point wiring complete all as specified and directed.
Taking down switches / sockets / DB fittings etc complete all as specified and directed.
PROVISIONAL SUM
Provn of following items complete all as directed by Engineer-in-Charge. (a) Provn of Foot Ball / Hockey Grounds - 01 No. (b) Provn of Basket Ball Courts - 02 Nos. (c) Provn of Volley Ball Courts - 02 Nos. (d) Provn of Training shed - 140 Sqm (e) Provn of Hard standing - 80 Sqm TOTAL AMOUNT = ₹ 35,70,000.00 Add/deduct__________%(___________ percent) ₹____________ Above/below Total cost is at par SSR-2020 rate, Bidder to quote total amount after considering percentage addition/deduction thereto to cover market variation over head and profit etc. The amount shown is approximate. The exact requirement of the items will be carried out based on Drgs/SSR 2020 rate and adjusted with quoted percentage.
MAA BHAGWATI ASSOCIATES
AKM CONSTRUCTION AND ENGINEERING LLP
DOOARS CONSTRUCTION COMPANY
NARSINGH DEVELOPERS LLP
M.P. SITANI AND SONS
B D Raizada Projects Pvt Ltd
CHHABINDRA KUMAR PRADHAN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Download all tender documents and submit your bid