Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.8 L+₹2.9 L (6.21%)Rejected-Finance KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹49.4 L+₹3.4 L (7.41%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹49.7 L+₹3.8 L (8.21%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹50.0 L+₹4.0 L (8.75%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
3 Sept 2024, 6:00 pmClosed
GE HADDO PORT BLAIR
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
REPAIR/MAINTENANCE OF SEA WATER PUMP SETS AND CERTAIN EXTERNAL ELECTRICAL AND WATER SUPPLY WORKS AT NSCB, NSRY AND MC DET, SAMUDRIKA, NAVY PARK AREA AND CERTAIN WORKS AT E/M INSTALLATIONS UNDER GE HADDO, PORT BLAIR
2024_MES_664118_1
8877/E8
Open Tender
Civil Works
Item Rate
180 days
PORT BLAIR
As per tender documents
9 documents required · 9 mandatory
₹500
GE HADDO
₹92,000
Yes
21 Jan 2025
5 Jul 2024
10 Sept 2024
5 Jul 2024
3 Sept 2024
19 Jul 2024
Amount
Supply and fix MS flanged pipe 150 mm NB heavy duty thickness not less than 4.8 mm, including all fabrication fittings and joints, cutting /welding /making bend etc at any angle as required length and layed in ground fixed on wall/ floor/ sump/ duct etc duly painted with 2 coats of synthetic enamel paint over coat of zinc chromate primer incl taking down of old damaged pipe line from the existing location complete all as specified and directed.
S & F CI Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch, double branch, cross (for all sockets or socket & spigot, flanged pipes) collars etc all as specified and directed by Engr In Charge.
M & L for new lead joint for CI Pipe/ fittings all as specified and directed by Engr In Charge.
M & L for stopping leakage by repairing the lead for CI Pipe/ fittings all as specified and directed by Engr In Charge.
M&L for repair to damaged portion of MS pipes of 150/200 mm size by cutting the pipes to weld both internally, externally and testing for leakage including removing the material / scrap during the work all as specified and directed.
S&F Pressure gauge 4" dial 0-14 kgs rating, incl cutting, welding of pipe line all as specified and as directed by Engr In Charge.
Material and Labour for lifting the RCC slab upto 300 mm thick and about 2.5 ton to 4 ton in weight on jetty by cutting / chipping the clearance groove all around, keeping aside using a crane and refixing at the same location after carrying out repairs/ laying of pipeline including making good the surface with PCC 1:2:4, type B1, using 20mm graded stone aggregate complete all as specified and directed.
M&L for 80 mm dia or bore galvanized steel tubing, medium grade, with all fittings and laid on floor/ in trenches, ducts etc or fixed to walls and ceilings, with outside colour coding in RED/BLUE including taking down old unserviceable pipe complete all as specified and as directed.
Description all as item No 8.0 above but 50 mm dia.
Description all as item No 8.0 above but 40 mm dia.
Description all as item No 8.0 above but 25 mm dia.
S & F in repairs 25 mm dia outer dia CPVC pipies SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed.
S & F in repairs 40 mm dia outer dia CPVC pipies SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed.
S & F in repairs 50 mm dia outer dia CPVC pipies SDR 13.5 and plain CPVC SDR 11 fittings on wall / ceiling/ floor including suitable fittings as requied complete all as specified and directed.
M&L of PP-R Ball valves (brass insert) of size 25 mm dia as per requirement of the site all as specifed and directed by Engineer in Charge.
M&L of PP-R Ball valves (brass insert) of size 50 mm dia as per requirement of the site all as specifed and directed by Engineer in Charge.
S & F cast iron sluice valve, 200 mm size or bore, class PN 1.6, ISI marked, heavy duty with brass spindle, operating wheel, flanged on both ends along with suitable new rubber packing (gasket), stainless steel bolts, nuts & washers and necessary modifications if required for fixing in location including taking down old unserviceable sluice valve of any description complete all as specified and as directed.
Description all as item No 17.0 above but 150 size or bore.
Description all as item No 17.0 above but 100 size or bore.
Description all as item No 17.0 above but 80 size or bore.
S & F butterfly valve, 80 mm size or bore, ISI marked, heavy duty brass, side handle operated for fire fighting including taking down old unserviceable one complete all as specified and as directed.
S & F Gate Valve, 50 mm size or bore, ISI marked, heavy duty brass, side handle operated for fire fighting including taking down old unserviceable one complete all as specified and as directed.
S & F Gate Valve, 25mm size or bore, ISI marked, heavy duty brass, side handle operated for fire fighting including taking down old unserviceable one complete all as specified and as directed.
Supply, install and testing of new yard fire hydrant stand post of 80 mm dia GI / MS both flanged type 1.5m height both ends flanged, including duct foot bend double end flanged including taking down old unserviceable one complete all as specified and as directed.
S&F hydrant valve for fire fighting, double headed, ISI marked, conforming to IS:5290, 63 mm dia or bore, oblique type with instantaneous hose coupling adapter etc., with necessary fitting material including taking down old unsv fire hydrant valve complete all as specified and as directed.
Description all as item No 25.0 above but single headed.
S&F DOL starter up to 7.5 HP Capacity in Sheet-Steel Enclosure and as per existing make & model Complete all as specified and directed.
M&L for Overhauling of fire fighting pump set of capacity 150 HP after removing from base plate disconnecting from pipe line and dismantling pump set, replacing gland packing, gun metal bush, bearing and water seal, Shaft, casing wear ring etc and applying grease etc, reassembling the pump set and refixing back on the base plate and connecting with existing pipe line with nuts, bolts and new gasket including dismantling the motor, cleaning the rotor, starter, varnishing, backing etc and reassembling the motor and painting motor and pump sets including suction and discharge pipe line also connecting the existing cable etc. including testing the pumping set for full satisfaction of Engg- in -charge, complete all as specified and as directed by Engineer-in-charge.
Disconnecting/ dismantling 3 phase, 440 volts, 50 cycles electrical motor with centrifugal /monoblock pumpset (electrically and mechanically) from its location and shifting to work shop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding of motor with appropriate gauge, weight and turns of super enamelled copper winding wire using proper Garware insulating paper, insulating with Class I varnish, and oven drying for requisite insulation values, reassembling the motor completely and bringing back to its original location, cleaning the impeller of pump, supply & replace gland rope, greasing, replacement of unserviceable spares of pump, fixing back in position, connecting back electrically and mechanically with proper alignment and testing complete all as specified and as directed for 150 HP capacities of centrifugal/ monoblock pumpsets of any make. NOTES: (i) Insulation of winding shall be Class 'B' upto 7.5 HP and Class 'F' for 10 HP and above. (ii) Old material obtained from replacement shall be contractor's property as per Schedule of credit given in tender.
Description all as item No 29.0 above but 2-4 HP
M&L for Overhauling ofpressure pump set of capacity 1 HP upto 7 stage after removing from base plate disconnecting from pipe line and dismantling pump set, replacing gland packing, gun metal bush, bearing and water seal, Shaft and applying grease etc, reassembling the pump set and refixing back on the base plate and connecting with existing pipe line with nuts, bolts and new gasket including testing the pumping set for full satisfaction of Engg- in -charge, complete all as specified and as directed by Engineer-in-charge.
S & F Pressure switch in repairs suitable for 1 HP pressure pump including connected accessories all as specified and directed by Engr In Charge
M & L for checking the leakage from the pressure pump accessories i.e. joints, sockets etc of cap 1 HP, opening the defective parts and refix the same after rectification all as specified and directed by Engr In Charge.
Material and labour for preparation of old painted surface of Diesel Driven fire pump set incl engine of cap 35 BHP (Qty-1) and electrical driven pumping sets (Qty-02) of capacity upto 150 HP incl connecting pipe lines inside the insatllation by scaraping out old painted surfaces and painting with spray painting of existing colour synthetic enamel paint over one coat of red oxide primer all as directed by Engr-in-Charge.
Material and labour for preparation of old painted surface of LT panel (Qty-1) and Control panel/ starter panel for fire fighting pumping set of cap 150 HP (Qty-02) by scaraping out old painted surfaces and painting with spray painting of existing colour synthetic enamel paint over one coat of red oxide primer all as directed by Engr-in-Charge.
M & L for Mechanical seals suitabile for 150 HP pump sets to prevent lekages all as per OEM recommendations all as specifed and as directed.
M&L for Laser alignment of fire fighting pumping set with motor of cap 150 HP of any make/ model set including replacement of rubber coupling complete all as specified and as directed by Engineer-in-charge. .
M & L for cleaning/ servicing the LT Panel/ starter panel, by opening nut, bolts, links any type, loosen contacts, cables, removing the dust from the spares and reassembling/ reconncetion the same incl lugs with the cables as existing all as specified and directed by Engr In Charge.
Taking up old unserviceable water storage tank and S & F rotational moulded polyethylene water storage tank double layer, ISI marked, (Cylindrical vertical with closed top) with GI medium grade pipe for inlet, outlet, over flow, checknuts for inlet and outlet, hoisted and fixed in position including 25 mm PTMT Ball valve all as specified of following sizes:-
All as per Item No. 39.00 but for 500 Ltrs
All as per Item No. 39.00 but for 1000 Ltrs
All as per Item No. 39.00 but for 2000 Ltrs
S & F in repairs ball valve/ float valve complete with polythene float, fly nut for GI Pipe connection including necessary GI fittings such as elbow, nipple etc of size 25 mm dia including taking down old float valve all as specified and as directed
M&L the following capacity of PVC/ RCC Service tank situated at various place at any height, removing the inlet and outlet coupling connections and cleaning and removing all dirty muddy water from the service tank PVC/ RCC by using wire mesh brushes, brooms including scraping the all scale formation, neatly cleaning inside surfaces by using bleaching powder. Details of tanks like date of cleaning, capacity of tanks and due date for cleaning etc shall be written on the out side of the tank with synthetic enamel paint with letter size 10cm in white colour, over a black background of size 60 x 40 cm including cleaning of bottom surfaces of platform, RCC/ PCC slab including replacement of the unserviceable defective inlet and outlet suitable size coupling and fittings, etc complete all as specified and directed.
Service tank of capacity upto 500 Ltrs
Service tank of capacity 700 Ltrs to 1000 Ltrs
Service tank of capacity 2000 Ltrs to 3000 Ltrs
Service tank of capacity 5000 Ltrs
M&L Islolate water supply valve to the following UG/Semi UG sump/OH Tank at any height cleaning and removing all dirty muddy water from the sump/OH Tank , scrapping/scrubbing the inside walls by using wire brushes, brooms to remove all fungus scale formations, cleaning the inner surfaces of sumps with use of bleaching powder and washing internal surfaces of the walls and applying one coat of white wash to the internal surface of sump/OH tanks. Details of tank like Date of cleaning, Due date, and capacity of tank etc shall be written on the out side of the tank with synthetic enamel paint with letter size 20 cm in white colour, over a black background of size 100 x 60 cm complete all as specified and directed by Engineer-in-Charge for the following capacity / types:-
UG sump of 70000 Gallons capacity at Navy park pump house
Over head tank of 25000 Ltrs capacity at Navy park pump house
Sump Well of dia upto 2.7 mtr and depth 15.0 mtr of at Ross Island.
Material & labour for laying of chequered plates by cutting / making in to the shape providing necessary angular supports and handles with 6 mm dia rod as per the site condition for cable trenches of sub-station alongwith painting of one coat of synthetic enamel over a coat of two coats of redoxide all as specified and directed.
Material & labour for laying of Plain or corrugated steel sheets, any thickness as reqd by cutting / making in to the shape providing necessary angular supports and handles with 6 mm dia rod as per the site condition for trench/ chamber cover of sub-station alongwith painting of two coat of synthetic enamel over a coat of one coats of redoxide all as specified and directed.
S&F framed bracket of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plates, riveting etc as in chamber cover including cutting tops to shape as directed, drilling holes, notching for wire etc.
M&L for Precast cement concrete (PCC) type B1 1:2:4 using 20mm graded aggregate stone for making copings including use and waste of form work complete all as specified and directed.
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6.15 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip 32 mm x6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel with wire mesh,. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. NOTES: 1) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. 2) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
M&L for Excavation in trenches not exc 1.5 M deep and 1.5 M width and getting out in soft or loose soil for foundation of poles (or) cable laying complete all as specified and directed.
M&L for Returning, filling incl spreading, levelling, watering and well ramming layers not exc 25 cm for cable laying complete all as specified and directed.
M & L for Removing/excavated soil to a distance not exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
Supply,laying,testing and commissioning of LT XLPE insulated, armoured heavy duty electric aluminium conductor cable 1100 Volts grade of cross section 2 core x 6 sqmm (laid in trenches,ducts,pole,wall etc.) incl taking down old unsv cable all as specified and directed. Make : Polycab/Gloster/Anchor/Havells/Finolex
All as per above item No.52.0 here in before but calble of size 2 core x 10 sqmm (laid in trenches,ducts,pole,wall etc.) Make : Polycab/ Gloster /Anchor/ Havells /Finolex
All as per above item No.52.0 here in before but cable size 4 core x 16 sqmm Make : Polycab/ Gloster/ Anchor /Havells/ Finolex
All as per above item No. 52.0 here in before but of cable size 4 core x 25 sqmm Make : Polycab/ Gloster /Anchor/ Havells/ Finolex
All as per above item No 52.0 here in before but of cable size 3.5 core x 35 sqmm Make : Polycab /Gloster /Anchor/ Havells/ Finolex
All as per above item No 52.0 here in before but of cable size 3.5 core x 50 sqmm Make : Polycab /Gloster /Anchor/ Havells/ Finolex
All as per above item No 52.0 here in before but of cable size 3.5 core x 70 sqmm Make : Polycab /Gloster /Anchor/ Havells/ Finolex
All as per above item No 52.0 here in before but of cable size 3.5 core x 120 sqmm Make : Polycab /Gloster /Anchor/ Havells/ Finolex
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 40 mm(OD) x 32mm (ID) along with connected accessories like couplers.bends,end caps etc. for HT cable protection all as specified and directed.Make:Rex Poly Extrusion Ltd/Tirupati Plastomatics Pvt Ltd.
All as per above item No 60.0 here in before but of size 50 mm(OD) x 38mm(ID).
All as per above item No 60.0 here in before but of size 77 mm(OD) x 63mm(ID).
Supply & fix in replacement FRP pole box 170 x 170 x 105 mm consisting of 1 No 50 A 4 pole connector and 1 No 16 A MCB SP including taking down the old/unserviceable junction boxes all as specified and directed. Make : SINTEX Cat No. GS-JB-1414 or equivalent & Make of MCB: L&T/Havells/ Legrand/Indo Asian
Supply & fix in replacement FRP pole box 240 x 130 x 95 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6-16 A MCB SP(as required) including taking down the old/unserviceable junction boxes all as specified and directed. Make : SINTEX Cat No. GS-JB or equivalent Make of MCB: L&T/Havells/ Legrand/ Indo Asian
Supply only of Electronic drivers (as per existing) for illuminating 10 watt LED post top /LED fittings operated at Input AC 185-265V ,50hz output DC-42-65V 300MA P.F 0.95 all as specified and directed.
Description all as per item No 65.0 above but Driver for LED Fitting of cap 20-40 watt all as specified and directed. .
Supply and fixing in replacement of LED Bollard with round top 9/10 W ,220V 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation cable condits for loop in and out , cable connectors complete all as specified and directed. Make Cat no. LBLSN-10-CDL of Crompton graves or equivalent in Bajaj / Havells/ Philips /C&S .
Supply and fixing of outdoor type Decorative Post top for 360° indirect light with IP 65 protection, resistant to impact and corrosion of 240 v,50hz of capacity 40 watt LED suitable for mounting on 60 mm OD pipe on necessasry PCC works complete all as specified and directed. Make:Cat Part No : LPTO-40-CDL-M of CG or equivalent in Philips/C&S
S & F of LED post top lantern of cap 20 watt, IP65 Rated, ideal to light up parks, gardens etc suitable for mounting on 60 mm OD pipe on incl taking down old fittings complete all as specified and directed .Make: CG Cat Part No -LPTH-20-CDL or equivalent in Philips/ C&S/ Havells.
Supply and fixing in replacement of LED floodlight of cap 150 watt made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, System efficacy ≥ 110/120LPW 10KV included driver including fixing on High mast of any hight or any pole/ wall/ iron structure etc including taking down of the old unserviceable halogen/any type of old unsv light fittings all as specified and directed. Make: CG Model No :LFLN-150-CDL/60-M or equivalent model of /Philips /Havells /Luker
Description all as per item No 70.0 above but LED floodlight of cap 120 watt. Make: CG Model No :TFS-504-120-57-60D-SL-GL-NSG or equivalent model of /Philips/ Havells /Luker
Description all as per item No 70.0 above but LED floodlight of cap 70 watt. Make: CG Model No :TFS-504-70-57-60D-SL-GL-NSG or equivalent model of /Philips /Havells /Luker
Supply and fixing in replacement of LED floodlight of cap 50 watt (of any coloured as reqd) made up of pressure die cast aluminium housing with toughened glass and high power LEDs included driver along with mounting bracket including fixing on pole/ wall/ iron structure etc including taking down of the old unserviceable halogen/any type of old unsv light fittings all as specified and directed. Make: Luker Model No : LFLSL50NSG or equivalent model of /Philips/Havells/CG
Supply and fixing of LED street light fixture of cap 70 watt ,aerodynamically designed for all weather conditions with excellent thermal management, made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP66 protection. Efficacy > 110/120 LPW, with 10KV SPD including taking down the old unsv light fitting of any type all as specified and directed. Make: CG Model No :TRP-409-70-57-SL-GL-NSG or equivalent model of /Philips/ Havells/ Luker
S & F in replacement of 9 Watts holder type (E22) LED lamp (E22) 230 Volts, 50Hz complete all as specified and as directed. Make :- Philips/ CG/ Havells/ Bajaj
S & F PVC Insulated and PVC Round Sheathed 2 core 1.0 sqmm Bright Annealed Bare Copper Conductor Heavy Duty Flexible Cables for Voltage Grade 1100 Volts for connection of lights from junction box complete all as psecified and directed.
Supply and fixing with wall/ pillar/ iron structure etc of hot dip galvanised perforated cable tray, with solid cover fabricated from GI Sheet in standared length of 2.4 mtr of thickness 1.2 mm , depth 100 mm , width 200 mm alongwith GI cover tray ,accessories i.e. bends (any type), right/left/center reducer , tee, straight coupler etc as required at site including MS work for support/ hanging of suitable size as directed complete all as specified and directed by Engr In Charge . Note:- (i) The measurement shall be calculated as RM incl accessories for the cable tray.
Taking down old timer panel and supply and fixing of out door type Street light timer Panel /Distribution Boards with pole, panel etc as directed alongwith 65A 3 pole/230 Volts contactor and Digital 24 hrs/ Analog Time Switch, 63 A MCB, Manual and Auto Mode Toggle switch cable connectors, cable gland etc including suitable fixing arrangement with existing pole/ panel all as specified and directed. Make: Cat No. TL065AB0 of indoasian Time lite or equivalent.
S&F Drive end bearing of existing make and model as per site requirement for 30 to 125 KVA DG set of any make as existing including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.
S&F Non drive end bearing of existing make and model as per site requirement for 30 to 125 KVA DG set of any make as existing including main rotor dynamic balancing including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.
Taking down unserviceable self-starter 12 volts for 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing, from engine, dismantling and opening of stater and armature,replace the wornout carbon brush, pinion,ignition coil bearing,bushing, including servicing, varnishing of stater after repairing assembling,refixed to same position complete all as specified and directed.
Cleaning the radiator intercooler of 30 to 125 KVA DG set or Fire pump diesel engine B35 HP of any make as existing by checking and removing the deposited dust, oil welt and carbon deposits etc. with wire brushes, cleaning agents etc. complete all as specified and as directed by Engineer-in-charge
S&F in repairs 4 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type MCX 33 for AMF panel complete all as specified and as directed by Engineer-in-charge.
S&F in repairs Electronic timer with auxiliary voltage of 110/240v, 50Hz for operation of 9-30 sec complete all as specified and as directed by Engineer-in-charge.
M & L for supply and fixing Automatic Voltage Regulator Model AX - 02 suitable for 30 to 125 KVA DG set of any make as existing , starting and testing on load all as specified and directed. Make: Altex /Kirlosakr
M&L for carrying out "B" check for 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing as per manufacturer's recommendation including replacement of necessary spares and Filters such as Fuel filter, SLO Bypass filter and lub oil filter complete including rectification of minor defects, cleaning of air filters/ breather & coolant tank with air blower, replacement of Engine oil & coolant and tuning of engine all as specified and directed. [Notes: (i) Supply only Engine oil & Coolant shall be measured and paid separately. (ii) Rate quoted shall include for all filters, topping up distilled water in batteries & minor accessories like nuts, bolts, 'O' rings etc.]
Supply only Engine oil 15w 40 type:CH4 or CI4 as per requirement and manufacturer recommendation . [Make: Servo/ Valvoline/ Castrol/Mobil]
Supply only concentrated Engine coolant [Make: K-Cool or as recommended by OEM]
S&F battery terminal, brass heavy duty (two nos) complete suitable for fixing on battery poles with nuts and bolts complete including disconnecting and taking down unserviceable battery terminal all as specified and directed.
S&F battery lead copper conductor single core 70 sq.mm, 2 metre long (two nos) complete including soldering of copper lugs including disconnecting and taking down unserviceable battery lead complete all as specified and as directed by Engineer-in-charge.
M&L for removing oil/ grease deposits, oil/ paint/ corrosion flakes and cleaning the external surface of 30 to 125 KVA DG set of any make as existing,along with acoustic enclosure., using wire brushes, coarse cloth, cleaning agents etc. and applying two coats of heat retardant paint of approved tint by spray application complete including necessary T&P like spray gun, air compressor etc.complete all as specified and as directed by Engineer-in-charge.
S&F in repairs 4 pole power contactors of auxiliary coil supply of 220 V, 50Hz AC supply with 2 NO + 2 NC contacts, type MCX 11 for AMF panel complete all as specified and as directed by Engineer-in-charge.
Dismantling and taking out old unserviceable burnt terminal blocks connectors from mounting base of 30 to 125 KVA DG set of any make as existing Alternator inlet & outlet cables and supply & fixing for Terminal blocks connector and re-connecting of same cables properly including providing of new lugs & alternator top cover farbrication all as specified .
Dismantling of Fuel pump from 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing for Replacement of FIP Solenoid switch for fuel pump and re-connecting for the same fuel pump properly including all as specified .
Dismantling and taking out old unserviceable water pump for 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing and M & L for new water pump including all as specified .
Draininng up the fuel tank/Diesel tank in a separate empty barrels, disconnecting the fuel lines from the fuel filters and taking out the fuel tank and clearing internally and remove the accumulated slludge/Sediments and arresting leakages, reconnecting back all the removed fuel lines and mounting the diesel tank its orginal position, supply and replacing the drain plug suitable and including painting of external surfaces by using synthetic enamel paint of two coats over one coat of red oxide primer testing complete for 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make .
Dismantling,dismounting and transportation of 100 / 125 KVA DG set of any make as existing, alternator assembly of existing Make of DG Set from its foundation and rewinding of main stator with suitable gauge of 'F' class enamelled winding wire of copper as per OEM recommendations,air drying,insulating varnish and becktrol red,heating insulation etc. and refixing/reassembling the alternator assembly to its foundation including connection,amputation,hot and cold checkups etc.inluding alignment and testing all as specified and directed by Engineer-in-Charge. Note: Rate includes necessary transportation to workshop and back.
Supply and connect and test lead acid battery heavy duty 12 volt 150 Ahin repairs complete with initial charging complete all as specified. (Make : Exide/Amaron)
All as per Item No. 98.0 herein before but for of capacity 12 V 120 AH
Dismantling and taking down Engine of capacity 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing, any cylinder, 1500 RPM, water cooled by dismantling/strip opening of the DG set for Top overhauling by removing the cylinder heads, piston, connecting rod, cylinder liner, oil sump and injector etc including calibration of engine and reassembling of the complete engine as per the manufacturer instruction incl replacing all the gaskets and testing of efficiency of engine on completion of repair work complete all as directed. (worn out parts shall be measured and paid seperately)
Supply only cylinder head by removing worn out valves, valve guide, valve seat etc of existing make and model of 30-125 KVA DG Set or Fire pump diesel engine 35 BHP complete all as specified and directed.
Taking out crank shaft for existing make and model for 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing carefully, taking to local market for turning, polishing, metal filling if necessary and refixing of the engine including replacement of main bearings and oil seal complete all as directed.
Supply only turbo charger core assembly for 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing and model complete all as directed.
Supply only coupling flexible for 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing and model complete all as specified and directe
Supply only lub oil cooler 30 to 125 KVA DG set or Fire pump diesel engine 35 BHP of any make as existing complete all as specified and directe
Supply only alternator/dynamo 12 volt for 30-125 KVA DG Set or Fire pump diesel engine 35 BHP existing make and model complete all as specified and directed
Supply only oil seal complete of existing make and model complete all as specified and directed
Supply only Stop Solenoid for 30-125 KVA DG Set or Fire pump diesel engine 35 BHP existing make and model complete all as specified and directed
Supply only piston for 30-125 KVA DG Set or Fire pump diesel engine 35 BHP existing make and model complete all as specified and directed
Supply only piston rings for 40-160 KVA DG Set or Fire pump diesel engine 35 BHP existing make and model complete all as specified and directed
Supply only gasket for 30-125 KVA DG Set or Fire pump diesel engine 35 BHP existing make and model complete all as specified and directed
Supply only liner for 30-125 KVA DG Set or Fire pump diesel engine 35 BHP existing make and model complete all as specified and directed
Supply only Sleeves for 30-125 KVA DG Set or Fire pump diesel engine 35 BHP existing make and model complete all as specified and directed
Checking of DG Set internel connections like battery connections, solenoid adjusting and PCB contoller etc and tuning of DG Set of capacity 30KVA to 125KVA when and as required basis complete all as directed.
S&F PCB Controller as per existing make and model as per site requirement for 30-125 KVA DG set or Fire pump diesel engine 35 BHP including making connections and tuning of DG Set including taking down old unserviceable item complete all as specified and as directed by Engineer-in-charge.
S&F in repairs fuel hose pipe/lube oil hose pipe of 10mm to 25mm dia (60psi) flexible type, heavy duty as per existing length for 40 to 125KVA DG Set or Fire pump diesel engine 35 HP complete all as directed.
S&F in repairs water hose pipe/fuel hose pipe/lube oil hose pipe of 32mm to 50mm diac flexible type, heavy duty as per existing length for 30-125 DG Set or Fire pump diesel engine 35 HP complete all as directed.
M&L Cotton waste for cleaning of DG sets all as specified and as directed by Engineer-in-charge.
S&F Belt V ribbed type to drive alternator from pulley as per existing maodel and make for 30 to 125KVA DG Set or Fire pump diesel engine 35 HP complete all as specified and as directed by Engineer-in-charge.
Taking down old Silencer Exhaust pipe of any dia and length of existing make and model mouted at any height and ceaning with cleaning agents, metal filling as per site requirement for 30 to 125KVA DG sets or Fire pump diesel engine 35 BHP installed in Haddo station, refixing the same Silencer Exhaust pipe with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge.
Taking down old Silencer Exhaust pipe and S&F Silencer Exhaust pipe with wool insulation of any dia and length of existing make and model mouted at any height as per site requirement for 40 to 160 KVA DG sets installed at haddo station with necessary new nuts, bolts and washers including making good the disturbed surfaces complete all as specified and as directed by Engineer-in-charge.
S & F in replacement of manual change over switch with sheet steel enclosure of cap 250 Amp 4 pole, 415 V, fixing with wall/ panel ect as specified and directed by Engr In Charge.
S & F in replacement of switch disconnector fuse unit (open execution) with DIN fuse link of cap 250 Amp 4 pole, 415 V, fixing with wall/ panel etc or as existign location as specified and directed by Engr In Charge. Make -L&T model No SK95642 or equivalent
S & F in replacement of switch disconnector fuse unit in SS enclosure with DIN fuse link of cap 250 Amp 4 pole, 415 V, fixing with wall/ panel etc or as existign location as specified and directed by Engr In Charge. Make -L&T model No SK90489 or equivalent
S & F in replacement of MCCB 4 pole, 63 Amps, 50 Hz, 415 Volts, 25 KA Adjustable Thermal and Fixed Magnetic setting, with separator link - 1 No .
Description all as item No 126.0 above but 100 Amps, 25 KA.
Description all as item No 126.0 above but 160 Amps, 25 KA.
Description all as item No 126.0 above but 200 Amps, 36 KA.
Description all as item No 126.0 above but 250 Amps, 36 KA.
Description all as item No 126.0 above but 400 Amps, 36 KA.
S & F in replacement of SS Enclosure including MCCB 160 to 250 Amps MCCB, 4 pole, 25 KA , 415 V, IK08 and IP30 Protection and with connected fixing accessories with Wall/ panel/ pole etc as specified and directed by Engr In Charge. Make:- L & T model No CM91003OOOO or equivalent.
S & F in replacement Panel LED Phase indicator (R-Y-B) along with connected wiring not less than 1.0 sqmm copper wire all as specified and directed by Engr In Charge.
S & F in replacement of Volt meter/ Ammter digital type of size 96 x 96 mm,1 phase, class -1, 0.5 VA with connected wiring all as specified and directed by Engr In Charge.
Taking down carefully old unserviceable aluminum/ copper point wiring (light, fan, socket or power) complete, including fittings & fixtures such as switches, ceiling roses, lamp holders, pendants, regulators sockets, light fittings, junction/terminal boxes etc; removing from site and making good disturbed surfaces of walls, floors etc., to match with existing surrounding surfaces complete all as specified and as directed.
Taking down existing unserviceable main switches/ distribution boards/Fuse Units of any description alongwith MCBs/MCCBs and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
Taking down carefully old unserviceable light fittings only and removing from site complete all as specified and as directed.
Taking down existing unserviceable sub main wiring of any description and making good disturbed surfaces to match with existing surrounding finishes complete all as specified and as directed.
M&L for Point wiring complete with 1.5 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC casing and capping of suitable size (not less than 25mm) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in CI boxes/pressed steel terminal boxes 60mm deep made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for the following:-
ONE LIGHT/FAN point controlled by one, one way 5 Amps switch.
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on independent board.
ONE 5A SOCKET OUTLET point controlled by one, one way 5 Amps switch on same board.
Description same as per item Sl No 140.0 above but point wiring with two single core 4.0 Sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 3 pin 15 Amps socket out let on independent board complete all as specified and directed.
S & F for switch modular type, 6 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F for socket outlet modular type 1 way 6 Amps, 3 pin, 230 volts AC circuit complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16, universal complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F stepped type modular fan regulator, 2 modular type complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC).
S & F high speed air ventilating fan 300 mm sweep single ph, 230 volt, steel body with louvers incl all fixing arrangement complete all as specified and directed.
S & F air ventilating fan 200 mm sweep single ph, 230 volt, PVC body with louvers incl all fixing arrangement complete all as specified and directed.
S & F in replacement of Supply & fix motor starter switch of capacity 25 Amps working on 240 volts AC supply alongwith with 25 Amps mini MCB SP type 'C' 240 volts for air conditioner complete all as specified and directed.
M&L for Sub main wiring complete with four runs (1P+1N) of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm wide rigid non-metallic PVC casing and capping and its accessories (OR) 25 mm dia PVC conduit and conduit accessories fixed in concealed or on surface of wall/ ceiling/roof/ floor complete all as specified and as directed.
S & F in replacement of DB VTPN sheet metal enclosure double door IP 43 protection, door earth suitable for incoming upto MCCB 100 Amps/ 200 Amps & outgoing MCB TP / SP. Triple pole and neutral 415 V 4 Way with 200 Amp rated standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete and making good to the distrubed surface /walls all as specified and directed.
S & F in replacement of MCB DB, SPN, 8-way, double door, 240 Volts with 200 Amps rated bus bar, IP-43 protection, shrouded neutral bus bar, cement spill protector, concealed in wall and making good disturbed surfaces to match with surrounding surface complete all as specified and as directed.
S & F in replacement of MCB, TPN, "C" series, 415 volts, 63 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S & F in replacement of MCB, SPN, "C" series, 230 volts, 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S & F in replacement of MCB, SP, "C" series, 240 volts, 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
S & F in replacement of 18 watts surface mounted LED light fitting , white/yellow colour as reuired as site with slim high perfomanance surfaced mounted LED light fittings, round/square shape as required at site made from die-cast aluminium and CRCA covering, powder coated in white colour complete all as specified and directed. MAKE: CG Cat No LCDSPLN-S-18-CDL or equivalent make of Havells/ Luker/ Philips NOTE: The rate quoted deemed to include for any alterations required to existing false ceiling as per site condition for fixing light fitting
S & F in replacement of of LED slim panel lighting fixture of 18 Watt recess mounted 220V , 50Hz with finished in premium white powder coating ,environmental friendly energy efficient fitting recess mounted round/square in shape (Warm white/ white colour as per requirement of site complete) of light as required at site) complete all as specified and directed. Make - CG Cat Part No : LSCSM-18W-CDL or equivalent make in Luker/ Philips/ Havells.
Description all as item No 158.0 above but 15 watt recess mounted. Make - CG Cat Part No : LSCSM-15W-CDL or equivalent make in Luker/ Philips/ Havells.
Supplying, fixing and testing Tube light fittings aluminium housing, Diffuser slim Integrated design LED 21 watts 4 feet, IP-20 including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Philips Cat Part No : BN021C LED22S or equivalent to CG/ Havells/ Luker
Supplying, fixing and testing Tube light fittings aluminium housing, Diffuser slim Integrated design LED 10 watts 2 feet, IP-20 including all accessories and fixing arrangements for fixing the light fitting complete all as specified and directed. Make: Philips Cat Part No : BN021C LED12S or equivalent to CG/ Havells/ Luker
S & F Surface mounted general purpose square shaped luminaire with low height CRCA housing and high transmissivity diffuser of cap 40 watt of size 595 mm x595mm x 65 mm including all accessories and fixing arrangements for fixing the light fitting to any heighted indoor palces complete all as specified and directed. Make :- Luker model No- LKMSRS40 or equivalent to Havells/ CG/ Philips
S & F in replacement 30 watts LED building security light fittings, IP 65 luminaire, Pressure die cast aluminium housing powder coated graphite grey and toughened glass including necessary fixing arrangements as per site requirements all as specified and directed by Engr In Charge. Make : Luker Cart Part No: LSTE-30 or equivalent to Philips /Havells
Taking down old corroded GI bracket of 25 mm dia and supply and fixing new GI brackets of GI pipe light grade of size 25 mm dia including nuts, bolts and washers for building secufity light all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed
S&F framed work such as grills, gratings etc with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works like cooler stand conforming to Fe-290, Gde -E-165
M&L for applying two coat of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surfaces of any description over 10cm width or girth not otherwise described complete all as specified and directed
Demolition stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D2 (Using 40mm graded stone aggregate) as in path finish the top surfaces even and rough to receive top layer complete all as specified and directed
M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with ditto as per item 171.00 above
Demolition of precast cement concrete block walling built in CM or cement lime Mortar complete all as specified and as directed.
M&L precast cement concrete block masonry exc 10 cm width with solid block PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) and setting in cement mortar 1:4 all as specified
M&L providing precast cement concrete solid building blocks PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) or slabs 10cm thick (with plain or interlocking joints as directed) setting in cement mortar 1:4 in walls complete all as specified
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for 10mm thick plaster in CM 1:6 on fair face of concrete surface or brick walls finished even and smooth without using extra cement complete all as specified
M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and directed
M&L for 15mm thick plaster in CM 1:4 on fair face of brick walls or concrete surface including mixing of liquid water proofing compound @ 200ml per 50 Kg cement bag, finished the surface even and smooth without using extra cement complete all as specified. (Note: Water proofing compound shall be measured and paid separately)
M&L for preparing newly plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed
M&L for complete removal of existing treatment on plastered wall surface and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm complete all as specified and directed
M&L for applying two coats of oil bound distemper after complete removal of existing treatment complete all as specified and directed
S&F in repairs Framed work such as ornamental and intricate design Gate, grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
Supply only water proofing compound
ss enterprises (BID ID -3074524)
Roop Sons and Co (BID ID -3074558)
SKV Engineering (BID ID -3079471)
Mahajan Builder (BID ID -3077383)
ANITA VARMA ENTERPRISES (BID ID -3078307)
M/s Prem Enterprise (BID ID -3078341)
NAVJEEVAN ENTERPRISES (BID ID -3078856)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .