| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹14.8 L+₹28,045 (1.93%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹16.6 L+₹2.1 L (14.2%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹18.0 L+₹3.4 L (23.5%)Rejected-AOC 34 35 ASHOKA ESTATE NEAR S S PUBLIC SCHOOL SEWLA SARAI AGRA 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | L5₹19.9 L+₹5.4 L (36.8%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest Bidder |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
11 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (South) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF LT OH/UG CIRCUIT AND SWITCH GEARS PANNEL BOARD, MCCBs AND OTHER CONNECTED ACCESSORIES AT ZONE-I AREA UNDER GE (S) JAIPUR
2022_MES_557753_1
GE (S)/J-46P /2022-23 8764/E8
Open Tender
Civil Works
Item Rate
210 days
Jaipur
Class E and category b(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹50,000
Yes
29 Nov 2022
15 Oct 2022
14 Nov 2022
15 Oct 2022
11 Nov 2022
29 Oct 2022
Amount
Excavation in trenches n.exc 1.5metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth complete as specified.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point complete.
M & L Sand cushioning to PVC under ground cable with Tibba sand and jently punning down to provide a required cover as specified.
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm as specified.
Dismantling of existing ACSR conductor of any size from insulators fixed on damaged / broken poles as directed by Engineer-in-Charge.
M&L for aluminium conductor steel reinforced (ACSR) straining properly on insulator and binding with aluminium tap/binding with connectors, jumpers etc.of any type and sizes complete all as specified and directed by engineer-in-charge.
Straining only of existing ACSR conductor of any size tying on existing poles properly on insulators and binding with aluminium tap/binding with connectors, jumpers etc conplete as directed by Engineer-in-Charge. (each length of conductor measured separately) Note for item No 7 & 8:- Measurement and payment shall be made by measuring horizontal distance between centre of two adjacent poles and adding 3% extra for sag, joints & jumpers etc.
Supply & fixing or laying galvanised steel tubing light grade for protection of under ground cable on poles / walls under road crossing etc of following sizes including dismantling & taking down existing pipe :-
(a) 100mm bore
(b) 80mm bore
(c) 50mm bore
M & L Earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with top edge of earth plate at a depth not less then 1.8 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron. Earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth strip on test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover including dismentling /taking out existing u/s earthing complete all as specified & directed. Note 1- Following items deemed to be included in quoted rate (a) Earth electrode (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 meter (c) Material and labour for connecting earth electrode and earthing lead as specified (d) Adequate quantity of charcoal dust and common salt as per direction (e) All labour involved including testing of earth network.(f) Excavation and earth work or drilling holes for electrode (g) P.C.C pit and C.I cover (h) Funnel with watering pipe, wire mesh and copper lugs etc as specified (j) G.I protection pipe pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover including dismentling /taking out existing u/s earthing complete all as specified & tested complete. Note 1- Following items deemed to be included in quoted rate (a) Earth electrode (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 meter (c) Material and labour for connecting earth electrode and earthing lead as specified (d) Adequate quantity of charcoal dust and common salt as per direction (e) All labour involved including testing of earth network.(f) Excavation and earth work or drilling holes for electrode (g) P.C.C pit and C.I cover (h) Funnel with watering pipe, wire mesh and copper lugs etc as specified (j) G.I protection pipe pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering. Note 2. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Trimming of tree branches upto 75 mm dia to clear the route of HT/LT over head lines (any nos of conductors) upto 3m all round from the conductor including removing the cut branches from site and depositing at places n exc 50m all as directed by Engineer-in-Charge. (Note :- 1. One span from pole to pole of distance not more than 30 metres(approx) shall be considered as one unit. 2. The frequency of trimming of tree branches shall not be less than 6 months and initial trimming to be carried out with in one month of handing over site and subsequent trimming if required to be carried out with prior written approval of GE.
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc incliuding taking down of following size :-
(a) 240 Sqmm, 3½ Core
(b) 185 Sqmm, 3½ Core
(c) 120 Sqmm, 3½ core cable
(d) 95 Sqmm, 3½ Core
(e) 70 Sqmm, 3½ Core
(f) 50 Sqmm, 3½ core cable
(g) 35 Sqmm, 3½ core cable
(h) 25 Sqmm, 3½ core cable
(j) 16 Sqmm, 4 core cable
M & L Painting (in situ) to old steel surface of Steel tubular pole 9.0 mtr long with attached accessories (cross arms, clamps, GI protection pipe etc) with one coat of aluminium paint after preparation of surfaces including painting to lower portion of poles with two coats of black & white synthetic enamel paints in straps alternatively all round the poles from the bottom of the pole for indication of poles. Height of the each strap shall be 30cm and number of straps shall be 5 Nos complete all as specified and directed by Engineer-in-Charge.
Supply and fixing cable heat shrink termenation outdoor (earthed) jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete all as specified of size:-
(a) 25 - 35 Sqmm 3½ Core
(b) 50 - 70 Sqmm 3½ Core
(c) 95 - 120 Sqmm 3½ Core
(d) 150 - 185 Sqmm 3½ Core
Supply and fixing cable heat shrink jointing kit for 1.1 KV grade cable for end termination joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete all as specified of size:-
(a) 25 - 35 Sqmm 3½ Core
(c) 50 - 70 Sqmm 3½ Core
(e) 95 - 120 Sqmm 3½ Core
(e) 150 - 185 Sqmm 3½ Core
(e) 240 - 300 Sqmm 3½ Core
M&L for fault locating machine for fault finding on requirement for LT/HT cables of any type/size complete all as specified and directed by Engr-in charge. Note :- One number of fault as located/found shall be measured as one Job/Unit for payment.
Disconnecting & taking out the existing Unserviceable MCCB from panel and Supply & fix new MCCBs 415 V, 50 Hz, 3 phase including extension terminals and connecting using suitable fasteners, modification/fabrication if any complete all as required at site complete as specified and directed of following capacity :-
(a) MCCB 63 amp, 4 pole 25 KA breaking cap of suitable frame size
(b) -ditto- but 100 amp, 4 pole 25 KA
(c) -ditto- but 125 amp, 4 pole 25 KA
(d) -ditto- but 160 amp, 4 pole 25 KA
(e) -ditto- but 200 amp, 4 pole 35/36 KA
(f) -ditto- but 250 amp, 4 pole 35/36 KA
(g) -ditto- but 320 amp, 4 pole 35/36 KA
(h) -ditto- but 400 amp, 4 pole 35/36 KA
S&F aluminium conductor cable of size 10 sq. mm, 2 core 1100 volts grade flat / round, heavy duty, PVC insulated and overall PVC sheathed as in service connections twin core cable flat / round incl taking out existing U/S service cable of any size
Surface Dressing/Cleaning of various 11 KV sub-stations free from vegetation or other neusence of any type including trimming of tree branches, bushes, creepers, etc. complete including removal of debries etc all as specified & directed. Note: 1. The frequency of surface dressing shall not be less than 2 months but total 03 times during currency of entire contract period and quoted rate to be deemed included the same for entire period.
M&L for repairing of existing LT panel of any size Doors welding, cutting, hinges, nuts, bolts etc including doors, hinges material also complete to make servicable/smooth functional all as specified and directed by Engr-in-charge.
Supply & fix LT panel out door (Kiosk type) type, weather & vermin proof MS sheet housing 3.15mm thick, powder coated over a coat of primer, double door, front & rear openable type, mounted on mild steel 40x40x6 mm angle iron frame, floor mounted type with one MCCB, 4 pole, 100 Amp, 25 KA 415 volts as incomer, copper bus bar 200 Amp of length not less than 60 cm, 4 pole duly drilled with holes for cable connections, after due approval of panel drawing including PCC pedestals of suitable size, removal of old unsv panel, making good the area complete all as specified and directed by Engr-in-charge including dismentling/replacement of existing wornout panel complete.
S & F Bus bar electrolytic grade copper 400 Amp of suitable sectional size & shape complete.
Supply & install steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified type 410 SP-31 (9 meters long) and providing with 02 coats of aluminium paint over a coat of red oxide primer complete all as directed by Engr-in-Charge including dismentling of existing damaged/broken pole with accessories complete.
M&L for raising the height of base plate from with lifting of LT existing panel to height of 450mm from ground using 40X40X6mm angle iron all including dismantling electrical connections welding, cutting, inches, nuts, bolts etc and pcc footings suitable to meet the ground requirement all as specified and directed by Engr-in- Charge.
M&L for painting of existing LT feeder pillar box one coat of of synthetic enamel paint all including preparation of surface etc all as specified and directed by Engr-in- Charge.
SHREE BHAGWATI ENTERPRISES
M/s Prakash Enterprises
M/S SHARADA ASOCIATE
M/s Radhey Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .